08-40-221RUN WIRING TO F/A PANEL FOR THE FOLLOWING SUPERVISION: CONTROLLER OPERATION INTO A MOTOR RUNNING CONDITION. LOSS OF LINE POWER ON LINE SIDE OF MOTOR STARTER IN ANY PHASE PHASE REVERSAL ON LINE SIDE OF MOTOR STARTER PROVIDE AN AUDIBLE VISUAL ALARM IN FIRE ALARM PANEL FOR ANY OF THE ABOVE MENTIONED CONDITIONS. ALL CONNECTIONS AND REQUIREMENTS TO BE AS PER MANUFACTURER'S WIRING DIAGRAM AND NFPA-20 (CENTRIFUGAL FIRE PUMPS). opiw ► FPL APPROVED HOUSE METER O 1 1/4"C FPL PAD MOUNTED XMER/CT'S 120/20MV,30 FIRE PUMP ROOM 4-#1 IN 2"C CONCRETE ENCASED — 3 RUNS OF V --3 RUNS OF (4#6�OOMCM) (4#400MCM) IN 4"C EACH IN 3 1/2"C EACH , 4#4/0 do 1#4(G) IN 2 1/2"C ELECTRICAL ROOM V V •V Viy 2 1 /2"EC MAIN ELECTRICAL ROOM V• ,+ V W O O* • • U u l' 4 Y f V 3P -1000A° - METER CENTER #2 (COMMERCIAL TYPE FPL APPROVED) TYPICAL #26000522 O O 120/208V, 30, IN/OUT PROVIDED WITH A 3P -1000A OF 12 TENANTS H-200 a M.C.B. (42K AIC) WITH (12) 200A EMPTY METER SOCKETS BREAKER SERVICE RATED M.C.1. _ _ FOR FUTURE TENANTS. FOR 65K AIC. M FOR 65K AIC. 12N1ANT (MAIN 2 OF 4) X9' 2 1 /2"EC 4#200MCM & 1#3(G) O O � 5 PNL HA 3? -1000A --METER NN1�MFPL 1) TYPICAL •� W V O O O O OB2O8V30IOU.PROVIDED WITHA3P-000A O12*TENANTS SECT SECT O o M.0. (42K A,C) WITH (12) 200A EMPTY METER SOCKETS #1 #2 — M.CD. FOR FUTURE TENANTS. 3 SETS OF (4#60OMCM & 1#310)) IN 4'C FIRE PIUMP RUNS OF ti W (4# 400MCM & 1#2/0(G)) 30HP, 208V, 30 (MAIN 1 OF 4)TIME � CLOCK (MAIN 3 OF 4) e;�3 IN 3 1/2"C EACH �6V I I ANY SERVICE CONDUITS 1 #4/0(G) IN 1 "C TO (2) 5/8"DIA X 1 OFT LONG TYPICAL FACTORY INSTALLED SERVICE RUNNING EXPOSED IN COPPER CLAD STEEL GND DRIVEN RODS ENTRANCE SURGE SUPPRESSOR. IF BASEMENT CEILING SPACE SPACED 6 FT APART, C.W.P. do FOUNDATION STEEL. NOT FACTORY PROVIDED CONTRACTOR FROM FPL XMER TO MAINS = SHALL PROVIDE & INSTALL. (TYPICAL) SHALL BE CONCRETE ENCASED ELECTRICAL RISER DIAGRAM N.T.S. NOTE: 1) ENGINEER ASSUMED A FAULT CURRENT OF 65K AIC. CONTRACTOR SHALL COORDINATE WITH FPL ACTUAL FAULT CURRENT. EQUIPMENT INSTALL WITHSTAND FPL'S AVAILABLE FAULT CURRENT. PRIOR TO ORDERING THE ELECTRICAL SWITCHGEAR THE CONTRACTOR SHALL OBTAIN FROM FPL A LETTER STATING THE AVAILABLE FAULT CURRENT. NO EXTRAS WILL BE ALLOWED FOR FAILURE TO DO SO. 2) ALL EQUIPMENT SHALL BE MOUNTED ABOVE FLOOD CRITERIA. 3) PROVIDE ALL EMPTY CONDUITS WITH PULL STRINGS. 4) COORDINATE HOUSE METERING REQUIREMENTS FOR DISTRIBUTION PANEL "DP" is FIRE PUMP WITH FPL. rU•• YYW V V •V Viy MAIN ELECTRICAL ROOM V• ,+ V W /•• • FIRE PUMP CONTROLLER WITH • • U u l' 4 Y f V G f • Y W FACTORY INSTALLED SERVICE #26000522 YV• VVU W 3P -1000A MAIN ENCLOSED 3P -1200A MAIN ENCLOSED RATED OVERCURENT PROTECTION. FACTORY MAIN SHALL BE RATED 4 V V � BREAKER SERVICE RATED BREAKER SERVICE RATED CUTTER FOR (65K AIC MINIMUM) FOR 65K AIC. M FOR 65K AIC. 12N1ANT (MAIN 2 OF 4) X9' n0" FEET 4#200MCM & 1#3(G) Y • SPACE DESIGNATED � 5 r • VV IN 3"C V ~ FOR FUTURE MAIN •� W V OS U 1— V V „ V V V SEE ELECT. ROOM W LAYOUT 3 SETS OF (4#60OMCM & 1#310)) IN 4'C FIRE PIUMP ti W IVVvy 30HP, 208V, 30 (MAIN 1 OF 4)TIME � CLOCK (MAIN 3 OF 4) (MAIN 4 OF 4) �6V � � V YYy Y V • V V 4PST Y DESIGNATE 24" OF MAIN V • TVSS TVSS NSS SPACE FOR FUTURE TENANT(S) V f V V V f DISTRIBUTION PANEL PNL YH• T/C a • V V MAINS do METER (TYPICAL) v' O w 4• "DP" '.• N � try �( 2 RUNS OF (4#600MCM) TVSS 3P -800A SECT 1 SECT #2 24 T , 24" 4" ,1 24" * 24 IN 4"C EACH (MAIN M.C.B. 1 OF 4) _ I I I 12 AFF" I (TYP) r � 2 3 1/2'1 Ec— _ 4/0(G) O S M SPARE TYPICAL I I ANY SERVICE CONDUITS 1 #4/0(G) IN 1 "C TO (2) 5/8"DIA X 1 OFT LONG TYPICAL FACTORY INSTALLED SERVICE RUNNING EXPOSED IN COPPER CLAD STEEL GND DRIVEN RODS ENTRANCE SURGE SUPPRESSOR. IF BASEMENT CEILING SPACE SPACED 6 FT APART, C.W.P. do FOUNDATION STEEL. NOT FACTORY PROVIDED CONTRACTOR FROM FPL XMER TO MAINS = SHALL PROVIDE & INSTALL. (TYPICAL) SHALL BE CONCRETE ENCASED ELECTRICAL RISER DIAGRAM N.T.S. NOTE: 1) ENGINEER ASSUMED A FAULT CURRENT OF 65K AIC. CONTRACTOR SHALL COORDINATE WITH FPL ACTUAL FAULT CURRENT. EQUIPMENT INSTALL WITHSTAND FPL'S AVAILABLE FAULT CURRENT. PRIOR TO ORDERING THE ELECTRICAL SWITCHGEAR THE CONTRACTOR SHALL OBTAIN FROM FPL A LETTER STATING THE AVAILABLE FAULT CURRENT. NO EXTRAS WILL BE ALLOWED FOR FAILURE TO DO SO. 2) ALL EQUIPMENT SHALL BE MOUNTED ABOVE FLOOD CRITERIA. 3) PROVIDE ALL EMPTY CONDUITS WITH PULL STRINGS. 4) COORDINATE HOUSE METERING REQUIREMENTS FOR DISTRIBUTION PANEL "DP" is FIRE PUMP WITH FPL. rU•• YYW V V •V Viy f Y i V V• ,+ V W /•• • • • U u l' 4 Y f V G f • Y W V Y u u Y #26000522 YV• VVU W Y V VVl 4 V V � M K S Y • � 5 r • VV V V ~ V V y V •� W V OS U 1— V V „ V V V W ti W IVVvy VY• � V y �6V � � V YYy Y V • V V •� Y 4 W • V • C7 V I•• V V Y• i• V f V V V f C • V V y W v' O w 4• '.• N � try M M w O r � O S M W v W 6 O � U C D � o M .-- M ROOF o y C W Q t O ti w � U fc W O W � � C U O t U t Z 4TH FL ARCHITECTURE INTERIOR DESIGN PLANNING SEAL 3RD FL 2ND FL INTERMEDIATE -0" AFF TENANT TENANT TENANT #103 #107 #108 2 1/2" EC 4" EC (2) 3 1/2"C GND FL BASEMENT CITY OF SOUTH H tAIANI 8UILDIE4G DEFT. ELECI'RICAL SECTIOM APPROVED BY:��^ DATE: 1�. r RONEY J. MATEU AR 0008220 JMM CONSULTING ENGINEERS, LLG M.E.P. 12651 S DIXIE HIGHWAY, SUITE 209 MIAMI, FLORIDA 33156 M.A. SUAREZ CONSULTING ENGINEERS STRUCTURAL ENGINEERING 4869 SW 75TH AVENUE MIAMI, FLORIDA 33155 PISTORINO & ALAM CONSULTING ENG. INC. CIVIL ENGINEERING ! 7171 SW 62ND AVENUE, 4TH FLOOR MIAMI, FLORIDA 33143 OXFORD UNIVERSAL 4311 PONCE DE LEON BLVD. CORAL GABLES, FLORIDA 33146 5966 SOUTH DIXIE BUILDING 5966 & 5970 SOUTH DIXIE HIGHWAY MIAMI, FLORIDA 33133 AncniitUiUntiNU UNLr bUintnrvutrnunUtU FOR BY CONTRACT THE CONTENTS OF THIS DRAWING ARE CONFIDENTIAL AND SHALL NOT BE TRANSMITTED TO ANY PARTY EXCEPT AS AUTHORIZED BY THE ARCHITECT/ENGINEERS OF RECORD PHASE PERMIT DRAWINGS FILE NAME: E-201.DWG FROJ ECT NO- MA0605 DRAWN BY: JMM CHECKED BY: JMM ISSUE DATE: DECEMBER 10, 2007 REVISIONS SHEET TITLE ELECTRICAL RISER DIAGRAM SHEET: OE: E-201 19