Loading...
08-40-183BEAM SCHEDULE MARK ELEV. SIZE BOTT: OVER 18" TOP CONT. "C" BARS "E" BARS STIRRUPS REMARKS B x D No. SIZE No. SIZE No. SIZE No. SIZE SIZE SPACING EACH END B-1 T.O,S 8"x16" 2 #6 2 #5 � r V V Z V VV #3 @ 6" O.C. G 1 1 B-1 +201-011 8"x24" 2 #7 2 #5 U7 Uj LL Q Z #3 @ 10" O,C, OU 1 B-2 +201-011 8"x24" 2 #8 2 #5 #3 @ 8" O.C. 1 B-3 +201-011 8"x24" 2 #7 2 #7 #3 @ 10" O C. 1 B-4 +201-011 8"x24" 2 #7 2 #7 #3 @ 10" O.C. 1 B 5 +201-011 8"x24" 2 #7 2 #7 #3 @ 10" O.C. 1 B-6 + 20'-0" 8"x24" 2 #7 2 #7 #3 @ 10" O.C. 2B-1 81lx24" 2 #8 2 #8 #3 @ 8" O.C. 2B-2 8"x24" 2 #8 2 #8 #3 @ 8" O.C. 213-3 8"x24" 2 #8 2 #8 #3 @ 8" O.C. 28-4 8"x24" 2 #8 2 #8 #3 @ 8" O.C. 2B-5 8"x24" 2 #8 2 #8 #3 @ 8" O.C. 213-6 8"x24" 2 #8 2 #8 #3 @ 8" O.C. 213-7 8"x24" 2 #8 2 #8 #3 @ 8" O.C. 2B-8 8"x24" 2 #8 2 #8 #3 @ 8" O.C. 2B-9 8°x24" 2 #8 2 #8 #3 @ 8" O.C. 2B-10 8"x24" 2 #8 2 #8 #3 @ 8" O.C. 2B-11 8"x24" 2 #8 2 #$ #3 @ a" O.C. 2B-12 8"x24" 2 #8 2 #8 1 #3 @ 8" O.C. 213-13 81'x24" 2 #8 2 #8 #3 @ 8" O.C. 213-14 213-15 + 23-6" 8"x24" 8"x46" 2 2 #8 #8 2 2 #8 #8 #3 #3 @ 8" O.C. @ 8" O.C. 213-16 T,O.S. 8" X 16"#3 2 #7 2 #5 @ 6" O.C. 3B-1 + 30'-0" 12" X 24" 3 #8 3 #8 #3 16 @ 5" BAL 10" 3B-2 + 30' 0" 12" X 24" 3 #8 3 #8 #3 16 @ 5" BAL 10" 3B-3 +30'-0" 12" X 24" 3 #8 3 #8 #3 16 @ 5" BAL 10" 313-4 + 30'-0" 12" X 24" 3 #8 3 #8 #3 16 @ 5" BAL 10" 5 + #3 16@5"BAL 10" + 0 #3 16 @ 5" BAL 10" 313-7 +301-0" 12" X 24" 3 #8 3 #$ #3 16 @ 5" BAL 10" 3B-8 +301-011 8" X 24" 2 #6 2 #6 #3 @ 8" O.C. 413-1 + 43-0" 8" X 24" 2 #6 2 #6 #3 @ 8" O.C. RB -1 +601-0" 24"x72" 3 #7 5 #9 #4 16 @ 5" BAL 10" TYPE II RB -2 + 60'-0" 24"x72" 3 #7 3 #9 #3 @ 8" O.C. RB -3 + 60'-0" 8"x72" 2 #6 2 #8 #3 @ 8" O.C. RB -4 + 60'-0" 6"x58" 2 #7 2 #7 #3 @ 8" O.C. RB -5 + 56'-0" 16"x32" 4 #7 4 #7 #3 @ 6" O.C. RB -6 + 60'-0" 16"x54" 2 #7 4 #8 #4 16 @ 5" BAL 10" TYPE II RB -7 + 56'-0" 24"x32" 3 #6 3 #6 #3 @ 10" O.C- RB-7 CANT. + 56'-0" 24"x32" 3 #6 3 #6 #4 @ 3" O.C. RB -8 + 56'-0" 8"x24"2 #6 2 #6 #3 @ 8" O.C. TB VARIES 8"x12" 2 #5 2 #5 #3 @ 12" O C. TB -1 VARIES 8"x20"2 #5 2 #5 #3 @ 12" O.C. TB -2 + 10'-0" 1211x24" 2t#6 2 #3 @ 6" O.C. ADD 2 #6 EA. VERT. FACE TB -3 8"x24" 2 2 L#6 #3 @ 12" O.C. INTERMEDIATE BEAM REINF: BEAM DEPTH BEAMS 8" WIDE BEAMS 9" TO 14" BEAMS 15" TO 18" OVER 18" UP TO 24" NONE NONE NONE NONE 25" TO 36" 2 #3 EA. FACE 2 #4 FA. FACE 2 #5 EA. FACE 2 #6 EA. FACE 37" TO 54" 2 #4 EA. FACE 2 #5 EA, FACE 3 #5 FA. FACE 3 #6 EA. FACE 55" & OVER #4 @20" EA. FACE 1 #5 @18" EA. FACE #5 @14" EA. FACE #6 @14" EA. FACE IE TYPE I TYPE II TYPE III n TYPE IV TYPE V TYPE VI TYPE VII STIRRUP TYPES Tnm C7CC1 /CCC 01 AKR CONC. SLAB (SEE PLAN) VARIES (SEE PLAN) TOP REINF. STL (SEE PLAN FOR SIZE & SPACING) P. C. J. (SEE PLAN) PRECAST SOFFIT Z = z oa w L N 4' MIN. P. C. J.(SEE PLAN) BRIG. TYP. JOIST NON-BEARING DETAIL N. T. S. TYP . CONC. BEAM - BEAM TOP STEEL N. T. S. TR NC. JOIST NON-BEARING DETAIL TYPICAL SOFFIT BEAM TO COLUMN DETAIL SCALE: 3/4'= V-0' L1 /3 1 3/4" CLEAR TYP. 3'-6" MIN, 70 N INTERMEDIATE BEAM REINFORCING (SEE SCHEDULE) EA 8" CONIC. BLOCK WALL T.O. BEAM (SEE PLAN) CONC. BEAM (SEE PLAN & SCH'L FOR SIZE & REINF.) TYP. CONC. JOIST END BEARING DETAIL N. T. . INTERMEDIATE BEAM REINFORCING (SEE SCHEDULE) CONC. BEAM - VVV VVV L V L V V V t u u U 6 UCS• u'•u V V u u VVy YV V 6 V V V V V ch (� W V V V �WU G u V V• u V U " U)Z v u U uVV u � r V V Z V VV ....� VVVV V VVCVU• G 1 CONC. COL. Q J (SEE SCHEDULE) TYPICAL SOFFIT BEAM TO COL. END CONDITIOf SCALE: 3/4'= 1'-0" "C' BARS (TOP OVER EACH SUPPORT) WHERE BARS DIFFER IN TWO f ,, ADJACENT SPANS AT A COMMON SUPPORT, THE. LARGER BARS PROVIDE 24 BAR DIA. MIN. SCHEDULED SHALL BE USED. OR TERMINATE ENDS IN STANDARD 90 HOOK OR SEMI- TOP CONT. (CONTINUOUS TOP BARS) LAP IN MIDDLE CIRCULAR HOOK. 1/3 OF SPANS WHERE REQUIRED. 2" CL 0,30 L 030 L 0.30 L 0.30 L . 0.25 L v lo N "E" BARS a -q• " . d * . 36 DIA * Q X . . . A . LAP . • • -. • 4 V . •q *A - • • A MIN. U MIN, 6 n 6.j A. MI N MIN, 6.a 6' MIN. 6 Z� A . STIRRUP SPACING AS . f A ALL REINF, STEEL IN SAME SCHEDULED. LAYER UNLESS OTHERWISE NOTED. FIRST STIRRUP SPACED FROM FACE OF SUPPORT L1 L2 L3 NOTES; 1. "L" INDICATES THE LARGER OF ADJACENT SPANS 2. WHERE BOTTOM BARS ARE INDICATED AS CONTINUOUS 5, WHEN NECESSARY, LAP BOTTOM BARS OVER SUPPORTS AND TOP BARS AT MIDSPAN WITH ADJACENT SPANS, SPLICES, WHERE NEEDED, SHALL AS SHOWN BE MADE IN THE END 1/3 OF SPAN WITH 24 DIA. LAP, 6, TOP BARS SHALL BE CONTINUOUS, IF REQUIRED, SPLICE WITH 36 BAR DIAMETER SPLICE 3. PLACE MAXIMUM OF 2 BARS PER LAYER ON 8" -WIDE BEAMS. AT INTERIOR SPANS OTHER THAN FIRST AND LAST. LOCATE SPLICE AT MIDSPAN. 7. BOTTOM REINFORCEMENT SHALL BE TERMINATED WITH ACI STANDARD HOOK 4. ALL BEAMS ARE CAST -IN-PLACE BEAMS, UNLESS OTHERWISE NOTED IN SCHEDULE FOR ALL PERIMETER BEAMS TYPICAL BEAM REINF. PLACING DIAGRAM N.T.S. GREATER OF � F_ GREATER OF 0.3/L1 OR 03/L2 w 0.3/L2 OR 0.3/L3 L4 OR L3/3 10_3'-6" MIN. 3'-6" MIN. U p &-6" MIN. 3'-6" MIN. WHICHEVER IS GREATER CV � "C" BARS a "C" BARS 3'-6" MIN 1' �2" STIRRUP STIRRUP "F" BARS U"G" BARS SPACING EXT. STRANDS 2" 1" DEEP KEYSPACING G" BARS 6" O.C. MAX. 6" O.C. MAX. CLOSED TIES � " BY MANUF SOFFIT P/C SOFFIT BEAM L1 L2 L3 CONC. COLUMN CONC, COLUMN CONC. COLUMN TYPICAL SOFFIT BEAM BAR PLACING DIAGRAM SCALE: N. T. S. NOTES: 1, PLACE A MINIMUM OF 2 BARS THROUGH CLOSED SHEAR REINF, 3. SPLICE "I" BARS AT SUPPORTS W/30 BAR DIAMETER LAP SPLICES. 2, SPLICE TOP BARS AT MID SPAN W/ 30 BAR DIAMETER LAP SPLICES, 4. PLACE "C" AND "G" BARS OVER RIGHT-HAND SUPPORT, UNLESS NOTED IN REMARKS. CONT "I" BARS "D" BARS R GI BARS L4 (CANTILEVER) - CONC. COLUMN 1 3/4" CLEAR IJ U UUUUu V V 6 v u • t • #26000522 o r V J U u CD w Y 17 U U lr ,aQ r F r u u = V •- U 4 V n w iui V UC3 V �� L w r � T N = M �/] M o � M C a r r" LL � a U � m o M N w C r r ` w c � C U o t U r z LU I ARCHITECTURE INTERIOR'bESIGN PLANNING SEAL MARIO A, SUAREZ� F.E, 25414 OXFORD UNIVERSAL 4311 PONCE DE LEON BLVD. CORAL GAILES, FLORIDA 33146 5966 SOUTH DIXIE BUILDING 5966 & 5970 SOUTH DIXIE HIGHWAY MIAMI, FLORIDA 33133 MATEU ARCHITECTURE INC. THIS DRAWING IS THE PROPERTY OF MATEU ARCHITECTURE INC UNLESS OTHERWISE PROVIDED FOR BY CONTRACT, THE CONTENTS OF THIS DRAWING ARE CONFIDENTIAL AND SHALL NOT BE TRANSMITTED TO ANY PARTY EXCEPT AS AJTHORI7FD BY THE ARCHITECT/ENGINEERS OF RECORD. PHASE PERMIT DRAWINGS FILE NAME: PROJECT NO: MA0605 DRAWN BY: M.A.S. CHECKED &Y; ISSUE DATE. DECEMBER 10, 2007 REVISIONS SHEET TITLE BEAM AND SOFFIT SCHEDULES & DETAILS SHEET: OF: S-303 19 U C A Ui A o LU w H [n cn C� 0 ch (� W °'L t Z Z U)Z U .tS W::' � r Z LLI < ....� W VJ Q J �� Z)AO U7 Uj LL Q Z U OU w-5 OXFORD UNIVERSAL 4311 PONCE DE LEON BLVD. CORAL GAILES, FLORIDA 33146 5966 SOUTH DIXIE BUILDING 5966 & 5970 SOUTH DIXIE HIGHWAY MIAMI, FLORIDA 33133 MATEU ARCHITECTURE INC. THIS DRAWING IS THE PROPERTY OF MATEU ARCHITECTURE INC UNLESS OTHERWISE PROVIDED FOR BY CONTRACT, THE CONTENTS OF THIS DRAWING ARE CONFIDENTIAL AND SHALL NOT BE TRANSMITTED TO ANY PARTY EXCEPT AS AJTHORI7FD BY THE ARCHITECT/ENGINEERS OF RECORD. PHASE PERMIT DRAWINGS FILE NAME: PROJECT NO: MA0605 DRAWN BY: M.A.S. CHECKED &Y; ISSUE DATE. DECEMBER 10, 2007 REVISIONS SHEET TITLE BEAM AND SOFFIT SCHEDULES & DETAILS SHEET: OF: S-303 19