Loading...
08-40-098EL.60'-0" T. 0. PARAPET EL, 56'-0" ROOF +67.8' NGVD �% EL. 43'-0" FOURTH FLOOR +54.8' NGVD EL. 30'-0" THIRD FLOOR +41.8' NGVD EL. 20'-0" SECOND FLOOR +31.8' NGVD h EL. 10'-0" INTERMEDIATE FLOOR +21.8' NGVD EL, V-0" GROUND FLOOR +11.8 NGVD SHIM, BACKER ROD do — SEALANT AS REQ'D. BY INSTALLER (TYP) EXTR ALUM "F" RECEIVER FASTENER @ 16" O.C. -- CLIP ANGLE WELDED TO TUBE STEEL TUBE STEEL WITH KYNAR FINISH 2 00 SHIM, BACKER ROD do SEALANT AS REQ'D. BY INSTALLER (TYP) EXTR ALUM "F" RECEIVER FASTENER 0 16" O.C.— TUBE STEEL WITH KYNAR FINISH EQUAL ELEVATOR TOWER SCORE LINE. SEE DETAILS (TYP) LIGHT TEXTURED STUCCO W/ PAINT FINISH 12" ZIP—RIB WALL PANEL SYSTEM W/ BRUSH FINISH. PROVIDE SHOF C/S PRODUCTS MODULAR ALUMINUM BAR GRILL W/ KYNAR FINISH. PROVIDE SHOP DWGS. FOR APPROVAL CONCRETE STAIR WITH GUARDRAIL, SEE FLOOR PLAN AND STRUCTURAL DRAWINGS ELECTRICAL EQUIPMENT ON CONCRETE PAD. SEE ELECTRICAL DWGS. 01floI_it'i 'Im DETAIL 311 _ 1 1_011 DENSE BOARD, TYPICAL FLASHING AND COUNTERFLASHING CONTINUOUS DRIP EDGE CONTINUOUS GUTTER STRAP INSTALLED ACCORDING TO MANUFACTURER'S SPECS. ALUMINUM GUTTER UC -02 PANEL BATTEN ® 23 J" O.C., TYPICAL METAL PANEL CLIP, TYPICAL ALUMINUM TUBE PURLIN FRAMING, TYPICAL, SEE CEILING PLAN FOR LAYOUT V-10 5/8" 6'-4" 1'-10 5/8" STAIR TOWER BEYOND OVER SIDEWALK TUBE STEEL DIAGONAL BRACE WELDED TO HORIZONTAL STEEL TUBE STEEL CABLE AND TURBUCKLE CROSS BRACING, SEE CEILING PLAN FOR LAYOUT TRANSLUCENT PENTAGLASS 16MM LIGHTWALL SYSTEM (NOA# 051207.1) BY CPI INTERNATIONAL IN ALUMINUM FRAMING, TYPICAL. CONTRACTOR TO PROVIDE SHOP DRAWING PRIOR TO FABRICATION FOR APPROVAL ELEVATION EQUAL DETAIL 4 A-202 311 = 11_(11 10'-0" SOUTH ELEVATION 3/32.1 _ 1 1_0.1 STEEL PLATE EMBEDDED IN CONCRETE WITH 'J' ANCHORS, 4 EACH STEEL CABLE AND TURBUCKLE CROSS BRACING WELDED TO STEEL PLATE STUCCO WITH PAINT FINISH OVER ENTIRE ASSEMBLY DETAIL 311 = 1 1_011 ARCHITECTURE INTERIOR DESIGN PLANNINC SEAL. a ;.t MONEY J. MATEU ' AR 0008220 JMM CONSULTING ENGINEERS, LLC M.E.P. 12651 S DIXIE HIGHWAY, SUITE 209 MIAMI, FLORIDA 33156 M.A. SUARE7 CONSULTING ENGINEERS STRUCTURAL ENGINEERING 4869 SW 75TH AVENUE MIAMI, FLORIDA 33155 PISTORINO & ALAM CONSULTING ENG. INC. CIVIL ENGINEERING 7171 SW 62ND AVENUE, 4TH FLOOR MIAMI, FLORIDA 33143 OXFORD UNIVERSAL 4311 PONCE DE LEON BLVD. CORAL GA6LES, FLORIDA 33146 5966 SOUTH DIXIE BUILDING 5966 & 5970 SOUTH DIXIE HIGHWAY MIAMI, FLORIDA 33133 MATE11 ARCHITECTURE INC THIS DRAWING IS THE PROPERTY OF MATED ARCHITECTURE INC. UNLESS OTHE'RWSE FRONDED FOR 6Y CONTRACT THE CONTENTS OF THIS DRAWING ARE CONFIDENTIAL AND SHALL NOT DE TRANSMITTED TO ANY PARTY EXCEPT AS AUTHORIZED RY THE: ARCHITECT/ENGINEERS OF RECORD PHASE PERMIT DRAWINGS FILE NAME: M:\0605\CD\SHEET\ARCH\A-202.DWCi PROJECT NO- MA0605 DRAWN NY' RAG GHECKED RY: RJM ISSUE; DATE: DECEMBER 10, 2007 REVISIONS #1 01-17-08 FIRE REVISIONS SHEET TITLE ELEVATIONS SHEET, OF: A-202 -