08-40-0502
5
• Y y y
rru •
• Y u
• Y V
i i y y V Y• Y
• V Y
U V Y y i
• U Y
LIFE SAFETY SYMBOLS
i Y i i V
XI—X11 Y
MEANS OF EGRESS — PATH OF TRAVEL-
-
1 HOUR FIRE RATED WALL/PARTITION
4 \
\ A 2 HOUR FIRE RATED WALL/PARTITION
i�Arr+llrlrrr�rrr�
F.E.
FIRE EXTINGUISHER
NOTE: SURFACE MTD. AT CMU/CONC.
\\ SEMI RECESSED AT PARTITIONS
3 �� / \\ B
OCCUPANCY USE
BASEMENT
OCCUPANCY LOAD
EGRESS WIDTH
EGRESS WIDTH
MIN STAIR WIDTH
MIN CORRIDOR/
MAX. EXIT ACCESS TRAVEL
MAX. COMMON
MAX. DEAD END
PARKING FLOOR
(FIC 2004 -TABLE 1004.1.2)
LEVEL
STAIR
(FISC 2004 -TABLE 1009.1)
AISLE WIDTH
DISTANCE
PATH OF TRAVEL
CORRIDOR
AREA
(FISC 2004 -TABLE 1005.1)
(FIC 2004 -TABLE 1005.1)
(FISC 2004 -TABLE 1016..2)
(FISC 2004 -TABLE -1015.1)
(FISC 20041013.3.1,
(FISC 2004 -TABLE -1016.3.2)
.2 IN PER PERSON
.3 IN PER PERSON)
1013.3.5, 1026, 1030)
"I" BUSINESS
27,190 / 200 =
1 / 200 PARKING
28 IN REQUIRED
41 IN ,REQUIRED
44 IN REQUIRED
N/A
300 FT SPRINKLERED GROUP
100 FT SPRINKLERED
50 FT
(FIC 2004—SECTION
136 OCCUPANTS
66 IN PROVIDED
96 IN PROVIDED
48 IN PROVIDED
"I"
304 is 1026)
250 FT SPRINKLERED GROUP
"M" MERCANTILE
•„
M
(FIC 2004—SECTION
399 Sc 1030)
\ NOTES:
T AIOR1 13 \\\\ ENTIRE BUILDING SHALL BE EQUIPPED WITH A FULLY AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION
i \
\ 903.3.1.1 OF THE FBC 2004
PROVIDE YACTILE FLOOR %� \ C
\
NUMBER SIGNAGE AT / \ INCIDENTAL USE PARKING GARAGE SEPARATION OF 1 HOUR FIRE RATING WITH AUTOMATIC SPRINKLER SYSTEM, 2004
\\ \ �� +5 FBC TABLE 302.1.1 —0" AFF TO COMPLY \
WITH 2004 FBC \\ PROVIDE CERTIFIED 2A -108C FIRE EXTINGUISHERS WITH A MAXIMUM TRAVEL DISTA CE OF 75'; SEE LIFE SAFETY
\ i 1009.5.3, 1019.1.7 AN \ PLANS FOR LOCATIONS. TOP OF "
^\ �� ICC/ANSI A117.1 � \ � ESTINGUISHERS TO BE 48 A.F.F. MAXIMUM. PRO IDE SEMI—RECESSED CABINETS
WITH 4" MAXIMUM PROJECTION FROM WALL TYPICAL
FOR FIRE ALARM AND EMERGENCY LIGHTING, REFER TO ELECTRICAL AND FIRE ALARM ENGINEERING DRAWINGS
\\ \\ \ CONSTRUCTION TYPE II B, 2004 FBC TABLE 601
\\ / PARKIN
\ 200 / \\
\ \ F G H I J K K.8 L
\
\ I I
\ \ \
2 HO SE PARATION
TY P II B
\ , \ NSTRUC ON, 2004
FBC TABLEI 602 I I I � I I
PRO DE TACTILE LOOP
--- -------------
/ \ i + —0" AFF TO CO PLY
ITH 2004 BC
\ I I I 1 1009.5.3, 1 C 19.1.7 A D I I
♦ \\ / ICC/ANSI Al 7.1 j
I
2 HOUR SEPARATION \
TYPE II B \
CONSTRUCTION, 2004
FBC TABLE 602 \
i
1 HOUR SEPARATION
TYPE II B \ \
CONSTRUCTION, 2004 \ \
FBC TABLE 602
\
\
\
\
PROVIDE OCCUPANCY
AND EXITING SIGNAGE
AS REQUIRED BY FIRE
OFFICIAL, TYPICAL
\ 3.2 — -'
\ o
I
.3.�
131' TRAVEL DISTANCE PARKING
200
I I I I I
7
E I I 4 I I I
190' TRAVEL DISTANCE
Ie—
—1 I
I
I
I
I I
I
I
I
I �
jN� SECOND LEVEL LIFE SAFETY PLAN
�-' 3/32.1 _ 1 1_0„
V VVVUV VYV
Y• Y u • V i
,826000522
4 ••Y y y IY]
t �
O �
� U
• • � W
V V • U V ,�,. ~
• V y- S
VYV VW �
a =
F- F. -
W r
• V V V V ��
N v u t •�+
L Y ,- ucz
V Y V 11
V U u • U114 U U
W
� u
AC4 m
� N
C N
� LL
h- •
v
An M
A M
o N
o
W uj
t uj
U jr
M IL
S t
M
fig,
�I t
L1J
1-
II
ARCHITECTURE `INTER1q 1E91N. "PNIN6' r
SEAL:
44
1 to 4, i# .,
M1 �" or. It }
k. Cs ~ i s
RONEY J. MATEU
AR 0008220
JMM CONSULTING ENGINEERS, LLC
M.E.P.
12651 S DIXIE HIGHWAY, SUITE 209
MIAMI, FLORIDA 33156
I
M.A. SUAREZ CONSULTING ENGINEERS
STRUCTURAL ENGINEERING
4869 SW 75TH AVENUE
MIAMI, FLORIDA 33155
PISTORINO & ALAM CONSULTING ENG. INC.
CIVIL ENGINEERING
7171 SW 62ND AVENUE, 4TH FLOOR
MIAMI, FLORIDA 33143
OXFORD UNIVERSAL
4311 PONCE DE LEON BLVD,
CORAL GABLES, FLORIDA 33146
5966 SOUTH
DIXIE BUILDING
5966 & 5970
SOUTH DIXIE HIGHWAY
MIAMI, FLORIDA 33133
MATEU ARCHITECTURE INC.
THIS DRAWING IS THE PROPERTY OF MATEU
ARCHITECTURE INC. UNLESS OTHERWISE PROVIDED
FOR BY CONTRACT. THE CONTENTS OF THIS
DRAWING ARE CONFIDENTIAL AND SHALL NOT
BE TRANSMITTED TO ANY PARTY EXCEPT AS
AUTHORIZED BY THE ARCHITECT/ ENGINEERS OF
RECORD.
PHASE
PERMIT DRAWINGS
FILE NAME:
M:\0605\CD\SH EENRCH\A-LSO4.DWG
PROJECT NO:
MA0605
DRAWN BY:
RAG
CHECKED BY:
RJM
ISSUE DATE:
DECEMBER 10, 2007
REVISIONS
#3 04-30-08 BLDG COMMENTS
#4 06-04-08 FIRE REVISIONS
SHEET TITLE
SECOND LEVEL
LIFE SAFETY PLAN
SHEET: OF
A-LSO4