08-40-0493
2 i /
\
5
5 &;L2 FDOOR
SS CAPACITY EGRESS CAPACITY
INTO STAIR STAIR WIDTH
4 \ 01 TABLE7.3.3.1) (NFRA 101 0 TABLE 7.3.3.1)
WIDTH OF DOOR/.2 WIDTH F STAIR/.3
<\ \\ \ OCCUPANT`
CAPACITY OCCUP NT CAPACITY
\ \\ \ EACH DOOR EACH STAIR
320 OCCUPANTS
/ \ / MAX. EA H FLOOR
/ \\ B
t V• 4
• Y V
G
G
r .. + V ..
S WIpTH
MIN STAIR WIDTH
MIN CORRIDOR /
MAX. EXIT ACCESS TRAVEL
MAX. COMMON
V•G
V M
V
V V
Y
•
i V
(
Y
M
V Y
V 4
Y
V
Y
VVu
�uV V
V
V
GYYY
(FIBC 2004 -TABLE -1015.1)
(FIC 20041013.3.1,
(FIC 2004 -TABLE -1016.3.2)
•uV
V
Y
VV
4 V
V
Y r Y •
LIFE SAFETY SYMBOLS YY `
V V V V V V V v
Y G
X■ MEANS OF EGRESS — PA*"HV uOF TRWEL
—<—; V•Y V • V.r V.. V V
-�-�-� 1 HOUR FIRE RATED WALL/PARTITION
Mm�mm�- 2 HOUR FIRE RATED WALL/PARTITION
FIRE EXTINGUISHER
NOTE: SURFACE MTD. AT CMU/CONC.
SEMI—RECESSED AT PARTITIONS
OCCUPANCY USE
BASEMENT
OCCUPANCY LOAD
EGRESS WIDTH
EGRE
S WIpTH
MIN STAIR WIDTH
MIN CORRIDOR /
MAX. EXIT ACCESS TRAVEL
MAX. COMMON
MAX. DEAD END
PARKING FLOOR
(FIC 2004-TAILE 1004.1.2)
LEVEL
STAIR
c n
(FBC 2004 -TABLE 1009.1)
AISLE WIDTH
DISTANCE
PATH OF TRAVEL
CORRIDOR
AREA
(FIC 2004 -TABLE 1005.1)
(FBC 20
4 -TABLE 1005.1)
(FIC 2004 -TABLE 1016.2)
(FIBC 2004 -TABLE -1015.1)
(FIC 20041013.3.1,
(FIC 2004 -TABLE -1016.3.2)
.2 IN PER PERSON
.3 IN PER
PERSON)
1013.3.5, 1026, 1030)
"I" BUSINESS
27,190 / 200 =
1 / 200 PARKING
23 IN REQUIRED
41 IN
REQUIRED
44 IN REQUIRED
N/A
300 FT SPRINKLERED GROUP
100 FT SPRINKLERED
50 FT
(FDC 2004—SECTION
136 OCCUPANTS
66 IN PROVIDED
96 IN
PROVIDED
48 IN PROVIDED
"1"
304 & 1026)
250 FT SPRINKLERED GROUP
"M" MERCANTILE
(FIC 2004 --SECTION
309 is 1030)
\\/ \♦ NOTES:
FAIR 1 3 \\ ENTIRE BUILDING SHALL BE EQUIPPED WITH A FULLY AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION
903.3.1.1 OF THE FBC 2004
PROVIDE ACTILE FLOOR f \\ \, C
NUMBER SIGNAGE AT INCIDENTAL USE PARKING GARAGE SEPARATION OF 1 HOUR FIRE RATING WITH AUTOMATIC SPRINKLER SYSTEM, 2004
/ \\
+5 FBC TABLE 302.1.1 —0 AFF TO COMPLY \
WITH 2004 FBC \\ PROVIDE CERTIFIED 2A-10BC FIRE EXTINGUISHERS WITH A MAXIMUM TRAVEL DISTA CE OF 75'; SEE LIFE SAFETY
1009.5.3, 1019.1.7 AN \ \
ICC/ANSI Al7.1 PLANS FOR LOCATIONS. TOP OF ESTINGUISHERS TO BE 48" A.F.F. MAXIMUM. PROVIDE SEMI—RECESSED CABINETS
\\ WITH 4" MAXIMUM PROJECTION FROM WALL TYPICAL
\\ \\ FOR FIRE ALARM AND EMERGENCY LIGHTING, REFER TO ELECTRICAL AND FIRE ALARM ENGINEERING DRAWINGS
\\\ \\\ \ CONSTRUCTION TYPE II B, 2004 FBC TABLE 601
\\ PARKIN \\
\ \ F G H I J K K.8 L
\
— \ — — - --� — — —_ - .r.� �...� . �.. 10
\ I\ I I I I
2 HO S PARATION
\ \
TY P II B
♦ \\\ \ / \ �\\ NSTRUC ON, 2004 3
FBC TABLEI 602 I I I I I
\ / DOWN --------- PRO DE TACTILE LOOP
---- —---------
--- NU BER SIG AGE— T__----____..._...�....._ I
\\ / —MOTORCYC PARKING, — — — —
-- — + '--0" AFF TO (O PLY
/ ♦ \\ ITH 2004 BC
TYPICAL
\ / I I I I 1009.5.3, 1 C 19.1.7 A D I I I
♦ \\ 5 ICC/ANSI Al 17.1 I
\
3.2
I
2 HOUR SEPARATION \ /
TYPE II B \
CONSTRUCTION, 2004 \\ \
FBC TABLE 602 /
1 HOUR SEPARATION \
TYPE II B \\ \
kq
CONSTRUCTION, 2004 \ \
FBC TABLE 602
TRAVEL DISTANCE
\
\\ 5
\
\
D E
T
F \
PROVIDE OCCUPANCY
AND EXITING SIGNAGE
AS REQUIRED BY FIRE — ---- ----
OFFICIAL, TYPICAL _
Y
71 I I ��'i" I I ��"`" I I III I II' \ k�:`a ��I
I I — � IIII it I — `�✓
PARKING
200
I
I
I
I I 4 I I I I I
I
190' TRAVEL DISTANCE
I
I
I
- - - - ----- ----- ----- ----- ----- ----- ----- ---------------- --------------L_JI
�lmu
"� '
SECOND LEVEL LIFE SAFETY PLAN.
3/3211 _ 11-011
ARCHITECTURE INTERIOR DESIGN PLANNING
SEAL' "
V:a
d;`'
RONEYJ:'MATU
AR 0001' 29 ^
JMM CONSULTING ENGINEERS, LLC
M.E.P.
12651 S DIXIE HIGHWAY, SUITE 209
MIAMI, FLORIDA 33156
i
M.A. SUAREZ CONSULTING ENGINEERS
STRUCTURAL ENGINEERING
4869 SW 75TH AVENUE
MIAMI, FLORIDA 33155
I
PISTORINO & ALAM CONSULTING ENG. INC.
CIVIL ENGINEERING
7171 SW 62ND AVENUE, 4TH FLOOR
MIAMI, FLORIDA 33143
OXFORD UNIVERSAL
4311 PONCE DE LEON BLVD.
CORAL GABLES, FLORIDA 33146
5966 SOUTH
DIXIE BUILDING
5966 & 5970
SOUTH DIXIE HIGHWAY
MIAMI, FLORIDA 33133
MATEU ARCHITECTURE INC.
THIS DRAWING IS THE PROPERTY OF MATEU
ARCHITECTURE INC. UNLESS OTHERWISE PROVIDED
FOR BY CONTRACT. THE CONTENTS OF THIS
DRAWING ARE CONFIDENTIAL AND SHALL NOT
BE TRANSMITTED TO ANY PARTY EXCEPT AS
AUTHORIZED BY THE ARCHITECT/ ENGINEERS OF
RECORD.
PHASE
PERMIT DRAWINGS
FILE NAME
PROJECT NO:
MA0605
DRAWN BY:
RAG
CHECKED BY:
RJM
ISSUE DATE:
DECEMBER 10, 2007
REVISIONS
#3 04-30-08 BLDG COMMENTS
#4 06-04-08 FIRE REVISIONS
#5 07-11-08 FIRE REVISIONS
SHEET TITLE
SECOND LEVEL
LIFE SAFETY PLAN
SHEET: OF
A-LSO4
c n
F
SECOND LEVEL LIFE SAFETY PLAN.
3/3211 _ 11-011
ARCHITECTURE INTERIOR DESIGN PLANNING
SEAL' "
V:a
d;`'
RONEYJ:'MATU
AR 0001' 29 ^
JMM CONSULTING ENGINEERS, LLC
M.E.P.
12651 S DIXIE HIGHWAY, SUITE 209
MIAMI, FLORIDA 33156
i
M.A. SUAREZ CONSULTING ENGINEERS
STRUCTURAL ENGINEERING
4869 SW 75TH AVENUE
MIAMI, FLORIDA 33155
I
PISTORINO & ALAM CONSULTING ENG. INC.
CIVIL ENGINEERING
7171 SW 62ND AVENUE, 4TH FLOOR
MIAMI, FLORIDA 33143
OXFORD UNIVERSAL
4311 PONCE DE LEON BLVD.
CORAL GABLES, FLORIDA 33146
5966 SOUTH
DIXIE BUILDING
5966 & 5970
SOUTH DIXIE HIGHWAY
MIAMI, FLORIDA 33133
MATEU ARCHITECTURE INC.
THIS DRAWING IS THE PROPERTY OF MATEU
ARCHITECTURE INC. UNLESS OTHERWISE PROVIDED
FOR BY CONTRACT. THE CONTENTS OF THIS
DRAWING ARE CONFIDENTIAL AND SHALL NOT
BE TRANSMITTED TO ANY PARTY EXCEPT AS
AUTHORIZED BY THE ARCHITECT/ ENGINEERS OF
RECORD.
PHASE
PERMIT DRAWINGS
FILE NAME
PROJECT NO:
MA0605
DRAWN BY:
RAG
CHECKED BY:
RJM
ISSUE DATE:
DECEMBER 10, 2007
REVISIONS
#3 04-30-08 BLDG COMMENTS
#4 06-04-08 FIRE REVISIONS
#5 07-11-08 FIRE REVISIONS
SHEET TITLE
SECOND LEVEL
LIFE SAFETY PLAN
SHEET: OF
A-LSO4