Loading...
08-40-031MANUFACTURER: 1. ENGLERT,INC.- ENGLERT SERIES 1300 ALUMINUM METAL PANEL N,O.A . ALTERNATES TO BE APPROVED BY ARCHITECT. * ALL SYSTEMS USED SHALL HAVE THE APPROVALS OF THE GOVERNING JURISDICTION AND BE ENERGY STAR RATED. WASTE MANAGEMENT A. COLLECT METAL SCRAP AND PLACE IN DESIGNATED AREA FOR RECYCLING. ROOFING (B.U.R.) SECTION 07500 TYPE OF MODIFIED BITUMINOUS SHEET ROOFING SYSTEM SPECIFIED IN THIS SECTION IS COMPRISED OF A PROTECTIVE LAYER (2 PLIES OF HOT MOPPED FIBERGLASS FELT), A MECHANICALLY FASTENED BASE SHEET, AND 2 -PLIES CONSISTING OF ELASTOMERIC ASPHALT REINFORCED WITH A FIBERGLASS MAT, THE TOP PLY BEING A MINERAL SURFACED CAP SHEET. ROOFING SYSTEM SHALL MEET THE WIND UPLIFT REQUIREMENTS OF ASCE 7-99. THE TOTAL "R -VALUE" OF 19 REQUIRED IS FOR THE ENTIRE ROOF ASSEMBLY SYSTEM. INCLUDING STRUCTURAL COMPONENTS AND AIR FILMS. CEILING AND PLENUM SPACES SHALL NOT BE USED IN CALCULATING TOTAL "R -VALUE". SUBMITTALS: .,,PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA, INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS FOR EACH TYPE OF ROOFING PRODUCT REQUIRED. 1. SUBMIT DATA SUBSTANTIATING THAT MATERIALS COMPLY WITH REQUIREMENTS. 2. SUBMIT COPIES OF MEMBRANE MANUFACTURER'S APPLICABLE FLASHING DETAIL SHEETS. FOR ASPHALT BITUMEN, PROVIDE LABEL ON EACH CONTAINER OR CERTIFICATION WITH EACH DELIVERY OF ASPHALT, INDICATING FLASH POINT (FP), FINISHED BLOWING TEMPERATURE (FBT), SOFTENING POINT (SP) AND EQUIVISCOUS TEMPERATURE (EVT). SAMPLES: SUBMIT FOR EACH ROOFING MATERIAL INCLUDING, BUT NOT LIMITED TO, ROOFING FELTS, BASE SHEET, AND MINERAL SURFACE CAP SHEET. SUBMIT WITH MANUFACTURER'S LABEL ATTACHED, AND FASTENERS APPROPRIATE FOR USE. GUARANTEE REQUIREMENTS: MANUFACTURER'S 10 YEAR N.D.L. GUARANTEE. - INSTALLERS 2 YEAR GUARANTEE NOTE: ONLY MANUFACTURER'S APPROVED APPLICATORS WILL BE ALLOWED TO PERFORM N.D.L. WORK. NO OTHER INSTALLERS WILL BE APPROVED. SUBJECT TO COMPLIANCE WITH SPECIFIED REQUIREMENTS, PROVIDE MODIFIED BITUMEN MEMBRANE ROOFING BY THE FOLLOWING: 1. TREMCO: POWERply PREMIUM FR T24 ALTRERNATIVES TO BE APPROVED BY ARCHITECT. * ALL SYSTEMS USED SHALL HAVE THE APPROVALS OF THE GOVERNING JURISDICTION AND BE ENERGY STAR RATED. SEALANT SECTION 07900 PROVIDE AND INSTALL SEALANTS COMPLYING WITH REQUIREMENTS INCLUDED HEREIN, IN ORDER TO ESTABLISH AND MAINTAIN AIRTIGHT, VERMIN PROOF, AND WATER PROOF CONTINUOUS SEALS ON A PERMANENT BASIS. 1.01 SUBMITTALS A. RATING SYSTEM DOCUMENTATION 1. PROVIDE A CUT SHEET AND/OR MATERIAL SAFETY DATA SHEET FOR EVERY SEALANT USED WITHIN THE BUILDING (NOT INCLUDING THE EXTERIOR SURFACE OF THE BUILDING), WITH VOC LEVELS HIGHLIGHTED. PART 2 - PRODUCTS 2.01 SEALANTS MATERIALS A. EXTERIOR GENERAL USE: 1. SINGLE -COMPOUND POLYURETHANE CONFORMING TO ASTM C920, TYPE S, CLASS 25, GRADE NS 2. SILICON: ONE -PART SILICON SEALANT, VOC CONTENT: MAXIMUM 15 GRAMS/LITER 3. ACRYLIC/SILICON: WATER-BASED SEALANT, VOC CONTENT: 31 GRAMS/LITER B. EXTERIOR CONCEALED JOINTS AND UNDER THRESHOLDS: ONE -PART BUTYL RUBBER CAULK CONFORMINT TO FS TT -S--001657, TYPE I C. EXTERIOR CONCEALED JOINTS BETWEEN TWO ASSEMBLED RIGID SURFACES IN COMPRESSION: POLYISOBUTYLENE SEALANT TAPE CONFORMING TO AAMA 804.1 D. EXTERIOR AND INTERIOR HORIZONTAL JOINTS SUBJECT TO PEDESTRIAN TRAFFIC: 1. TWO-PART POLYURETHANE CONFORMING TO ASTM C920, CLASS 25, TYPE M; SELF -LEVELING, ZERO-VOC 2. ONE -PART POLYURETHANE, VOC CONTENT: MAXIMUM 45 GRAMES/LITER E. INTERIOR NON -WET AREAS: ONE -COMPONENT ACRYLIC LATEX WATER-BASED SEALANT CONFORMING TO ASTM C834, VOC CONTENT: MAXIMUM 42 GRAMS/LITER F. INTERIOR WET AREAS: ONE PART, MILDEW -RESISTANT SILICONE RUBBER CONFORMING TO ASTM C920, TYPE S, CLASS 25, GRADE NS INSTALLATION: CLEAN JOINT SURFACES IMMEDIATELY BEFORE INSTALLATION. PRIME OR SEAL JOINT SURFACES AS RECOMMENDED BY MANUFACTURER. COMPLY WITH MANUFACTURER'S INSTRUCTIONS. FILL SEALANT ROBBET TO A SLIGHTLY CONCAVE SURFACE, SLIGHTLY BELOW ADJOINING SURFACES. WHERE HORIZONTAL JOINTS ARE BETWEEN A HORIZONTAL SURFACE AND VERTICAL SURFACE, FILL JOINT TO FORM A MINIMUM 1/4" RADIUS CONVEX COVE, SO THAT JOINT WILL NOT TRAP MOISTURE AND DIRT. CLEAN ADJOINING SURFACES BY WHATEVER MEANS MAY BE NECESSARY TO ELIMINATE EVIDENCE OF SPILLAGE. SEALANT AT BASE OF WATER-RESISTANT GYPSUM BOARD: PROVIDE 1/2" HIGH CONTINUOUS BEAD OF SILICONE SEALANT BETWEEN WATER-RESISTANT GYPSUM BOARD PANELS AND CONCRETE FLOORS, PRIOR TO INSTALLATION OF FLOOR AND WALL FINISHES. SEALANTS: ACRYLIC EMULSION LATEX (TYPE C): ASTM C834, SINGLE COMPONENT; COLOR AS SELECTED; AC -20 MANUFACTURED BY PEORA. BUTYL SEALANT (TYPE E): FS TT -S-1657, TYPE 1; SINGLE COMPONENT, SOLVENT RELEASE, NON -SKINNING, NON -SAGGING, BLACK COLOR; BC -158 MANUFACTURED BY PECORA. POLYURETHANE SEALANT (TYPE G): ASTM C920, TYPE S. GRADE NS, CLASS 25; SINGLE COMPONENT, CHEMICAL CURING, NON -STAINING, NON- BLEEDING, CAPABLE OF CONTINUOUS WATER IMMERSION, NON -SAGGING TYPE; COLOR AS SELECTED; SIFAFLEX 1- A MANUFACTURED BY SIKO CORP. 1. ELONGATION CAPABILITY - 25 PERCENT 2. SERVICE TEMPERATURE RANGE - 40 TO 165 DEGREES F (-40 TO 74 DEGREES C) 3. SHARE A HARDNESS RANGE - 35 TO 45 POLYURETHANE SEALANT (TYPE H): ASTM C920, TYPE M, GRADE NS, CLASS 25; MULTI - COMPONENT, CHEMICAL CURING, NON -STAINING, NON- BLEEDING, CAPABLE OF CONTINUOUS WATER IMMERSION, NON -SAGGING TYPES COLOR AS SELECTED; SIKAFLEX - 2C MANUFACTURED BY SIKA CORP. 1. ELONGATION CAPABILITY - 25 PERCENT 2. SERVICE TEMPERATURE RANGE - 40 TO 165 DEGREES F (-40 TO 74 DEGREES C). 3. SHARE A HARDNESS RANGE - 20 TO 30 SILICONE SEALANT (TYPE 1): ASTM C920, TYPE S, NS, CLASS 25, FDA APPROVED; SINGLE COMPONENT, SOLVENT CURING, NON -SAGGING, NON- STAINING, NON-BLEEDING COLOR AS SELECTED; CONSTRUCTION 1201 MANUFACTURED BY GE SILICONES. 1. ELONGATION CAPABILITY - 25 PERCENT 2. SERVICE TEMPERATURE RANGE - 80 TO 400 DEGREES F (-62 TO 204 DEGREES C). 3. SHARE A HARDNESS RANGE - 30 SILICONE SEALANT (TYPE J): ASTM C920, TYPE S, NS, CLASS 25, SINGLE COMPONENT, FUNGUS RESISTANT, CHEMICAL CURING, NON -SAGGING, NON --"STAINING, NON-BLEEDING TRANSLUCENT WHITE CENTER; SANITARY 1700 MANUFACTURED BY GE SILICONES. 1. ELONGATION CAPABILITY - 25 PERCENT 2. SERVICE TEMPERATURE RANGE - 80 TO 400 DEGREES F (-62 TO 204 DEGREES C). 3. SHARE A HARDNESS RANGE - 31 ACCESSORIES: PRIMER: NON -STAINING TYPE, RECOMMENDED BY SEALANT MANUFACTURER TO SUIT APPLICATION. JOINT CLEANER: NON ---CORROSIVE AND NON -STAINING TYPE, RECOMMENDED BY SEALANT MANUFACTURER; COMPATIBLE WITH JOINT FORMING MATERIALS. JOINT BACKING; ASTM D1056; ROUND, CLOSED CELL POLYETHLENE FOAM ROD; OVERSIZED 30 TO 50 PERCENT LARGER THAN JOINT WIDTH, GREEN ROD MANUFACTURER TO SUIT APPLICATION. WOOD DOORS SECTION 08210 PROVIDE AND INSTALL WOOD DOORS WHERE NOTED ON THE DRAWINGS, AS SPECIFIED HEREIN AND IN COMPLIANCE WITH APPLICABLE REQUIREMENTS OF NWWDA INDUSTRY STANDARD I.S. 1-A AND AWI "ARCHITECTURAL WOODWORK QUALITY STANDARDS". SOLID -CORE FLUSH WOOD DOORS: AWI SECTION 1300, CUSTOM GRADE, CONSTRUCTION MEETING AWI SPEC STANDARD #FPC -3: SOLID CORE WITH VENEER OF WHITE OAK SPECIES, RIFT CUT, FOR STAIN FINISH. PART 1 - GENERAL 1.01 SUBMITTALS A. RATING SYSTEM DOCUMENTATION 1. SUBMIT INVOICES SHOWING THE VENDOR'S FOREST STEWARDSHIP COUNCIL CHAIN -OF -CUSTODY CERTIFICATE NUMBER AND IDENTIFYING FSC -CERTIFIED PRODUCTS ON AN ITEM -BY -ITEM BASIS, AS DOCUMENTATION THAT AN FSC -ACCREDITED ORGANIZATION HAS CERTIFIED THAT THE WOOD OR WOOD PRODUCTS ARE FROM A WELL-MANAGED FOREST. 1.02 INDOOR AIR QUALITY A. DO NOT USE WOOD PRODUCTS CONTAINING UREA -FORMALDEHYDE BINDERS, OR SEAL ALL SURFACES. PART 2 - PRODUCTS 2.01 MATERIALS A. WOOD: 1. VENEER: FSC -CERTIFIED WOOD 2. CORE: a. FORMALDEHYDE -FREE, MEDIUM -DENSITY FIBERBOARD b. FSC -CERTIFIED, SOLID OR LAMINATED WOOD c. AGFIBER 3. FINISH: FACTORY -APPLIED FINISH PART 3 - EXECUTION 3.01 WASTE MANAGEMENT A. SEPARATE CORRUGATED CARDBOARD PACKING IN ACCORDANCE WITH THE WASTE MANAGEMENT PLAN AND PLACE IN DESIGNATED AREAS FOR RECYCLING. INSTALL DOORS TO COMPLY WITH NWMA I.S. I, SWI QUALITY STANDARDS AND MANUFACTURER'S INSTRUCTIONS. FIT DOORS TO FRAMES WITH UNIFORM CLEARANCES AND BEVELS. MACHINE DOORS FOR HARDWARE IN FIELD. SEAL CUT SURFACES OF DOOR EDGES AFTER FITTING AND MACHINING. REFINISH OR REPLACE DOORS DAMAGED DURING INSTALLATION AT THE CONTRACTORS EXPENSE. ALL EXTERIOR DOORS MUST HAVE AN APPROVED NOTICE OF ACCEPTANCE AS PER GOVERNING JURISDICTION. REFER TO BUILDING ELEVATIONS FOR WIND PRESSURE DESIGN LOADS. OVERHEAD ROLLING STEEL DOORS SECTION 08330 THE WORK INCLUDES OVERHEAD ROLLING STEEL DOORS INCLUDING NECESSARY ACCESSORIES SPECIFIED IN THIS SECTION. SHOP DRAWINGS do SUBMITTALS: SUBMIT PROPERLY IDENTIFIED MANUFACTURER'S LITERATURE INCLUDING MATERIALS SPECIFICATIONS, INSTALLATION DETAILS AND OTHER DATA BEFORE COMMENCING WORK INCLUDING A NOTICE OF ACCEPTANCE OF THE GOVERNING JURISDICTION. FABRICATION: WIND RESISTANCE - RESIST WIND PRESSURE OF 146 M.P.H. GALVANIZING - HOT -DIP PROCESS PURE ZINC COATING IN ACCORDANCE WITH ASTM STANDARDS. OPERATION - ELECTRICAL OPERATION. LOCKING - PROVIDE MEANS OF PADLOCKING. FINISH: SHOP CLEAN AND PRIME FERROUS METAL SURFACES EXPOSED AND CONCEALED, EXCEPT FAYING AND LUBRICATED SURFACES USING MANUFACTURER'S STANDARD RUST INHIBITIVE PRIMER. FIELD PAINT TO REQUIREMENTS ON DRAWINGS. COLOR SELECTED BY ARCHITECTS INSTALLATION: INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND WITH ACCEPTED SHOP DRAWINGS. INSTALL ACCURATELY, WITHOUT WARPAGE, TRUE TO LINE, PLUMB AND LEVEL. FINISH HARDWARE SECTION 08700 PROVIDE AND INSTALL FINISH HARDWARE THROUGHTOUT THE WORK AS NEEDED FOR A COMPLETE INSTALLATION AND AS INDICATED ON DRAWINGS. BLOCKING: COORDINATE WITH OTHER SECTIONS TO PROVIDE SOLID WOOD BLOCKING AT ALL LOCATIONS WHERE DOOR STOPS ARE TO BE MOUNTED TO DRYWALL PARTITIONS. FIRE -RATED OPENINGS: COMPLY WITH NFPA STANDARD NO. 80 AND LOCAL CODES FOR HARDWARE IN FIRE -RATED ASSEMBLIES. PROVIDE ONLY HARDWARE WHICH HAS BEEN TESTED AND LISTED BY UL OR FM IN COMPLIANCE WITH REQUIREMENTS OF DOOR AND DOOR FRAME LABELS. FASTENERS: PROVIDE NECESSARY SCREWS, BOLTS AND OTHER FASTENERS OF SUITABLE SIZE AND TYPE TO ANCHOR HARDWARE IN POSITION FOR LONG LIFE UNDER HARD USE. PROVIDE CONCEALED FASTENERS FOR HARDWARE UNITS WHICH ARE EXPOSED WHEN DOOR IS CLOSED. THRESHOLD SEAL: PROVIDE BUTYL RUBBER SEALANT MEETING FS TT -S- 001657 FOR INSTALLATION OF THRESHOLDS, AS MANUFACTURED BY PECORA, SONOBORN, OR TREMCO. INSTALL HARDWARE ITEMS AT HEIGHTS RECOMMENDED BY THE DOOR AND HARDWARE INSTITUTE, EXCEPT AS SPECIFICALY REQUIRED TO COMPLY WITH LOCAL CODES. INSTALL HARDWARE IN COMPLIANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. SET UNITS LEVEL, PLUMB AND TRUE. ADJUST AND CHECK OPERATION OF EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY. HARDWARE SCHEDULE: AS INDICATED ON THE DRAWINGS. MOUNTING HEIGHTS FOR HARDWARE FROM FINISHED FLOOR TO CENTER LINE OF HARDWARE ITEM: LOCKSETS: 38 INCH PUSH/PULLS: 42 INCH DEAD LOCKS: 48 INCH EXIT DEVICES: 38 INCH ACCEPTABLE MANUFACTURERS A. TO THE GREATEST EXTENT POSSIBLE, OBTAIN EACH KIND OF HARDWARE FROM ONLY ONE MANUFACTURER. B. IF MATERIAL MANUFACTURED BY OTHER THAN THAT SPECIFIED OR LISTED HEREWITH AS AN EQUAL, IS TO BE BID UPON, PERMISSION MUST BE REQUESTED FROM THE ARCHITECT SEVEN (7) DAYS PRIOR TO BIDDING. IF SUBSTITUTION IS ALLOWED, IT WILL BE SO NOTED BY ADDENDUM. FINISH HARDWARE SECTION 08710 WORK INCLUDED- THE WORK IN THIS SECTION SHALL INCLUDE FURNISHING OF ALL ITEMS OF FINISH HARDWARE AS HEREINAFTER SPECIFIED OR OBVIOUSLY NECESSARY TO COMPLETE THE BUILDING, EXCEPT THOSE ITEMS THAT ARE SPECIFICALLY EXCLUDED FROM THIS SECTION OF THE SPECIFICATION. RELATED WORK SPECIFIED ELSEWHERE- HOLLOW METAL DOORS AND FRAMES, ALUMINUM DOORS AND FRAMES, WOOD DOORS AND FRAMES FURNISH LABOR AND MATERIAL TO COMPLETE HARDWARE WORK INDICATED, AS SPECIFIED HEREIN, OR AS MAY BE REQUIRED BY ACTUAL CONDITIONS AT BUILDING. INCLUDE ALL NECESSARY SCREWS, BOLTS, EXPANSION SHIELDS, OTHER DEVICES, IF NECESSARY, AS REQUIRED FOR PROPER HARDWARE APPLICATION. THE HARDWARE SUPPLIER SHALL ASSUME ALL RESPONSIBILITY FOR CORRECT QUANTITIES. ALL HARDWARE SHALL MEET THE REQUIREMENTS OF FEDERAL, STATE AND LOCAL CODES HAVING JURISDICTION OVER THIS PROJECT, NOTWITHSTANDING ANY REAL OR APPARENT CONFLICT THEREWITH IN THESE SPECIFICATIONS. FASTENERS - HARDWARE AS FURNISHED SHALL CONFORM TO PUBLISHED TEMPLATES GENERALLY PREPARED FOR MACHINE SCREW INSTALLATION. FURNISH EACH ITEM COMPLETE WITH ALL SCREWS REQUIRED FOR INSTALLATION. TYPICALLY, ALL EXPOSED SCREWS INSTALLATION. INSOFAR AS PRACTICAL, FURNISHED CONCEALED TYPE FASTENERS FOR HARDWARE UNITS THAT HAVE EXPOSED SCREWS SHALL BE FURNISHED WITH PHILLIPS FLAT HEAD SCREWS, FINISHED TO MATCH ADJACENT HARDWARE. DOOR CLOSERS AND EXIT DEVICES TO BE INSTALLED WITH CLOSED HEAD THROUGH BOLTS (HEX BOLTS). QUALITY ASSURANCE A. THE SUPPLIER TO BE A DIRECTLY FRANCHISED DISTRIBUTOR OF THE PRODUCTS TO BE FURNISHED AND HAVE IN THEIR EMPLOY AN AHC (ARCHITECTURAL HARDWARE CONSULTANT). THIS PERSON IS TO BE AVAILABLE FOR CONSULTATION TO THE ARCHITECT, OWNER AND THE GENERAL CONTRACTOR AT REASONABLE TIMES DURING THE COURSE OF WORK. B. THE FINISH HARDWARE SUPPLIER SHALL PREPARE AND SUBMIT TO THE ARCHITECT SIX (6) COPIES OF A COMPLETE SCHEDULE IDENTIFYING EACH DOOR AND EACH SET NUMBER, FOLLOWING THE NUMBERING SYSTEM AND NOT CREATING ANY SEPARATE SYSTEM HIMSELF. HE SHALL SUBMIT THE SCHEDULE FOR REVIEW, MAKE CORRECTIONS AS DIRECTED AND RESUBMIT THE CORRECTED SCHEDULE FOR FINAL APPROVAL. APPROVAL OF SCHEDULE WILL NOT RELIEVE CONTRACTOR OF THE RESPONSIBILITY FOR FURNISHING ALL NECESSARY HARDWARE, INCLUDING THE RESPONSIBILITY FOR FURNISHING CORRECT QUANTITIES. C. NO MANUFACTURING ORDERS SHALL BE PLACED UNTIL DETAILED SCHEDULE HAS BEEN SUBMITTED TO THE ARCHITECT AND WRITTEN APPROVAL RECEIVED. D. AFTER HARDWARE SCHEDULE HAS BEEN APPROVED, FURNISH TEMPLATES REQUIRED BY MANUFACTURING CONTRACTORS FOR MAKING PROPER PROVISIONS IN THEIR WORK FOR ACCURATE FITTING, FINISHING HARDWARE SETTING. FURNISH TEMPLATES IN AMPLE TIME TO FACILITATE PROGRESS OF WORK. E. HARDWARE SUPPLIER SHALL HAVE AN OFFICE AND WAREHOUSE FACILITIES TO ACCOMMODATE THE MATERIALS USED ON THIS PROJECT. THE SUPPLIER MUST BE AN AUTHORIZED DISTRIBUTOR OF THE PRODUCTS SPECIFIED. F. THE HARDWARE MANUFACTURES ARE TO SUPPLY BOTH A PRE -INSTALLATION CLASS AS WELL AS A POST -INSTALLATION WALK-THRU. THIS IS TO INSURE PROPER INSTALLATION AND PROVIDE FOR ANY ADJUSTMENTS OR REPLACEMENTS OF HARDWARE AS REQUIRED. DELIVERY, STORAGE, AND HANDLING WRAP, PROTECT FINISHING HARDWARE ITEMS FOR SHIPMENT. DELIVER TO MANUFACTURING CONTRACTORS HARDWARE ITEMS REQUIRED BY THEM FOR THEIR APPLICATION; DELIVER BALANCE OF HARDWARE TO JOB; STORE IN DESIGNATED LOCATION. EACH ITEM SHALL BE CLEARLY MARKED WITH ITS INTENDED LOCATION. WARRANTY- THE MATERIAL FURNISHED SHALL BE WARRANTED FOR ONE YEAR AFTER INSTALLATION OR LONGER AS THE INDIVIDUAL MANUFACTURER'S WARRANTY PERMITS. OVERHEAD DOOR CLOSERS SHALL BE WARRANTED IN WRITING BY THE MANUFACTURER AGAINST FAILURE DUE TO DEFECTIVE MATERIALS AND WORKMANSHIP FOR A PERIOD OF TEN (10) YEARS COMMENCING ON THE DATE OF FINAL COMPLETION AND ACCEPTANCE, AND IN THE EVENT OF FAILURE, THE MANUFACTURE IS TO PROMPTLY REPAIR OR REPLACE THE DEFECTIVE WITH NO ADDITIONAL COST TO THE OWNER. 2.05 LOCKS, LATCHES AND BOLTS A. LOCKS SHALL MEET THESE CERTIFICATIONS: 1.CYLINDRICAL LOCKS -PROVIDE SEVEN YEAR WARRANTY. 2.06 DOOR STOPS: DOORSTOPS SHALL BE FURNISHED FOR ALL DOORS TO PREVENT DAMAGE TO DOORS OR HARDWARE FROM STRIKING ADJACENT WALLS OR FIXTURES. 2.07 THRESHOLDS AND WEATHERSTRIP: PROVIDE THRESHOLDS FOR ALL EXTERIOR SWING DOORS AND WEATHERSTRIP ALL DOORS TO PROHIBIT AIR INFILTRATION AND MOISTURE FROM ENTERING THROUGH EDGES OF DOORS AND FRAMES. PART III - EXECUTION 3.01 INSTALLATION: ALL HARDWARE SHALL BE APPLIED AND INSTALLED IN ACCORDANCE WITH THE FINISH HARDWARE SCHEDULE. CARE SHALL BE EXERCISED NOT TO MAR OR DAMAGE ADJACENT WORK. CONTRACTOR TO PROVIDE A SECURE LOCK-UP FOR HARDWARE DELIVERED TO THE PROJECT BUT NOT YET INSTALLED. CONTROL THE HANDLING AND INSTALLATION OF HARDWARE ITEMS THAT ARE NOT IMMEDIATELY REPLACEABLE, SO THAT THE COMPLETION OF THE WORK WILL NOT BE DELAYED BY HARDWARE LOSSES BOTH BEFORE AND AFTER INSTALLATION. NO HARDWARE IS TO BE INSTALLED UNTIL THE HARDWARE MANUFACTURES HAVE PROVIDED A PRE -INSTALLATION CLASS. THIS IS TO INSURE PROPER INSTALLATION OF THE SPECIFIED PRODUCTS. 3.02 ADJUSTING AND CLEANING: CONTRACTOR SHALL ADJUST ALL HARDWARE IN STRICT COMPLIANCE WITH MANUFACTURER'S INSTRUCTIONS. PRIOR TO TURNING PROJECT TO OWNER, CONTRACTOR SHALL CLEAN AND MAKE ANY FINAL ADJUSTMENTS TO THE FINISH HARDWARE. 3.03 PROTECTION: CONTRACTOR SHALL PROTECT THE HARDWARE, AS IT IS STORED ON CONSTRUCTION SITE IN A COVERED AND DRY PLACE. CONTRACTOR SHALL PROTECT EXPOSED HARDWARE INSTALLED ON DOORS DURING THE CONSTRUCTION PHASE. 3.04 HARDWARE SCHEDULE: THE FOLLOWING SCHEDULE IS FURNISHED FOR WHATEVER ASSISTANCE IT MAY AFFORD THE CONTRACTOR; DO NOT CONSIDER IT AS ENTIRELY INCLUSIVE. SHOULD ANY PARTICULAR DOOR OR ITEM BE OMITTED IN ANY SCHEDULED HARDWARE GROUP, PROVIDE DOOR OR ITEM WITH HARDWARE SAME AS REQUIRED FOR SIMILAR PURPOSES. QUANTITIES LISTED ARE FOR EACH PAIR OF DOORS OR FOR EACH SINGLE DOOR. GLASS AND GLAZING SECTION 08800 WORK INCLUDED: PROVIDE AND INSTALL GLASS AND GLAZING AS SHOWN ON THE DRAWINGS, AS SPECIFIED HEREIN, AND AS NEEDED TO MEET THE REQUIREMENTS OF THE CONSTRUCTION. GLAZING STANDARDS: COMPLY WITH RECOMMENDATIONS OF FLAT GLASS MARKETING ASSOCIATION (FGMA) "GLAZING MANUAL" AND "SEALANT MANUAL" AND SIGMA EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE INDICATED. REFER TO THOSE PUBLICATIONS FOR DEFINITIONS OF GLASS AND GLAZING TERMS NOT OTHERWISE DEFINED IN THIS SECTION OR OTHER REFERENCED STANDARDS. SAFETY GLAZING STANDARDS: WHERE SAFETY GLASS IS INDICATED OR REQUIRED BY AUTHORITIES HAVING JURISDICTION PROVIDE TYPE OF PRODUCTS INDICATED WHICH COMPLY WITH ANSI Z97.1 AND TESTING REQUIREMENTS OF 16 CFR PART 1201 FOR CATEGORY 11 MATERIALS. FLOAT GLASS: TYPE FG -A 1/4 INCH THICK MINIMUM, CLEAR UNLESS OTHERWISE INDICATED. TEMPERED GLASS: PROVIDE CLEAR PRIME GLASS 1/4 INCH THICK MINIMUM, WHICH HAS BEEN TREATED TO STRENGTHEN GLASS IN BENDING TO NOT LESS THEN 4.5 TIMES ANNEALED STRENGTH, CONFORMING TO ANSI Z97.1 AND CPSG 16 CFR 1201. CLEAN GLAZING CHANNEL AND OTHER FRAMING MEMBERS TO RECEIVE GLASS, IMMEDIATELY BEFORE GLAZING. REMOVE COATINGS WHICH ARE NOT FIRMLY BONDED TO SUBSTRATE. REMOVE LACQUER FROM METAL SURFACES WHERE ELASTOMERIC SEALANTS ARE USED. COMPLY WITH FGMA "GLAZING MANUAL" AND MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. USE MANUFACTURER'S RECOMMENDED SPACERS, BLOCKS, PRIMERS, SEALERS, GASKETS ND ACCESSORIES. INSTALL GLASS WITH UNIFORMITY OF PATTERN, DRAW, BOW AND ROLLER MARKS. INSTALL SEALANTS TO PROVIDE COMPLETE WETTING AND BOND AND TO CREATE A SUBSTANTIAL WASH AWAY FROM GLASS. INSTALL PRESSURIZED TAPES AND GASKETS TO PROTRUDE SLIGHTLY OUT OF CHANNEL, SO AS TO ELIMINATE DIRT AND MOISTURE POCKETS. REMOVE AND REPLACE DAMAGED GLASS AND GLAZING. WASH AND POLISH GLASS ON BOTH FACES NOT MORE THAN 4 DAYS SCHEDULED FOR INSPECTIONS INTENDED TO ESTABLISH DATE OF SUBSTANTIAL COMPLETION. COMPLY WITH GLASS MANUFACTURER'S RECOMMENDATIONS FOR CLEANING. ALL EXTERIOR WINDOWS AND GLAZING MUST HAVE A NOTICE OF ACCEPTANCE AS PER THE GOVERNING JURISDICTION. REFER TO BUILDING ELEVATIONS FOR WIND PRESSURE CALCULATIONS. GYPSUM DRYWALL SECTION 09250 PROVIDE AND INSTALL SCREW-TYPE METAL SUPPORT SYSTEM, GYPSUM WALLBOARD, AND DRYWALL FINISHING OF PARTITIONS, FURRING, CEILING AND SOFFIT DROPS WHERE SHOWN OR NOTED ON THE DRAWINGS AND AS SPECIFIED HEREIN. METAL FURRING: ASTM A525, G90, 26 GAGE MINIMUM, 1 1/2" DEPTH UNLESS NOTED OTHERWISE, SCREW-TYPE ZEE -SHAPED FURRING MEMBERS DESIGNED FOR MECHANICAL ATTACHMENT OF INSULATION BOARDS TO MONOLITHIC CONCRETE AND MASONRY WALLS. GYPSUM WALLBOARD: ASTM C36, TYPE X TAPERED EDGE, 5/8" THICKNESS UNLESS OTHERWISE INDICATED, IN MAXIMUM LENGTHS AVAILABLE TO MINIMIZE JOINTS. GYPSUM BACKING BOARD MAY BE UTILIZED FOR MULTI- LAYER APPLICATIONS. (REFER TO WALL TYPES FOR LOCATIONS) MOISTURE -RESISTANT GYPSUM WALLBOARD: 5/8" THICK SQUARE CUT ENDS, TAPED EDGES. TRIM ACCESSORIES: ASTM C475, PAPER REINFORCING JOINT TAPE, WITH READY MIXED VINYL --TYPE JOINT COMPOUND, MULTI-PURPOSE GRADE. COMPLY WITH "GYPSUM CONSTRUCTION HANDBOOK" BY UNITED STATES GYPSUM CO. GYPSUM ASSOCIATION GA -216 "RECOMMENDED SPECIFICATIONS FOR APPLICATION AND FINISHING OF GYPSUM BOARD" AND ASTM C754 "INSTALLATION OF FRAMING MEMBERS TO RECEIVE SCREW ATTACHED GYPSUM WALLBOARD, BACKING BOARD, OR WATER RESISTANT BACKING BOARD" FOR ALL INSTALLATION WORK. INSTALL GYPSUM BOARD VERTICALLY TO AVOID END -BUT JOINTS WHERE POSSIBLE., IF NECESSARY, LOCATE END BUTT JOINTS AS FAR FROM CENTER OF WALLS AND CEILINGS AS POSSIBLE, AND STAGGER NOT LESS THAN 1'-O". DO NOT INSTALL IMPERFECT, DAMAGED OR DAMP BOARDS. DO NOT FORCE IN PLACE. LOCATE JOINTS OVER SUPPORTS, WITH LIKE -EDGES (TAPERED OR CUT) ABUTTING. FORM CONTROL JOINTS WITH SPACE BETWEEN EDGES OF BOARDS, PREPARED TO RECEIVE TRIM ACCESSORIES. BASE OF MOISTURE RESISTANT GYPSUM BOARD: PROVIDE 1/2" GAP BETWEEN BOTTOM OF WATER RESISTANT GYPSUM BOARD AND FLOOR SURFACE FOR INSTALLATION OF CONTINUOUS SILICONE SEALANT. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS OF DRYWALL WORK. INSTALL EDGE TRIM AT ALL EDGES WHERE GYPSUM BOARD IS EXPOSED OR SEMI -EXPOSED. INSTALL CONTROL JOINTS ABOVE ALL DOOR JAMBS, AND AS INDICATED ON THE DRAWINGS. APPLY JOINT TREATMENT AT ALL JOINTS (BOTH DIRECTIONS), METAL TRIM FLANGES, PENETRATIONS, FASTENERS HEADS, SURFACE DEFECTS AND ELSEWHRE AS REQUIRED TO PREPARE WORK FOR FINAL FINISH. APPLY JOINT COMPOUND IN THREE (3) COATS AND SAND SMOOTH BETWEEN LAST TWO (2) COATS AND AFTER LAST COAT. INSTALL ACOUSTICAL INSULATION IN PARTITIONS INDICATED ON DRAWINGS TO ACHIEVE STC RATINGS NOTED. INSTALL ACOUSTICAL INSULATION IN PARTITIONS TIGHT WITHIN SPACES, AROUND CUT OPENINGS, BEHIND AROUND AND TIGHT TO PENETRATION ITEMS INSTALL ACOUSTICAL SEALANT IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. STONE FLOORING SECTION 09831 MATERIALS: SEE FINISH LEGEND FOR FLOOR BASE AND WALL MATERIALS. COMPLY WITH MANUFACTURE'S INSTRUCTIONS FOR MIXING AND INSTALLATION OF MATERIALS. EXTEND STONE WORK INTO RECESSES AND UNDER OR BEHIND EQUIPMENT AND FIXTURES, TO FORM A COMPLETE COVERING WITHOUT INTERRUPTIONS, EXCEPT AS OTHERWISE SHOWN. TERMINATE WORK NEATLY AT OBSTRUCTIONS, EDGES AND CORNERS WITHOUT DISRUPTING PATTERN OR JOINT ALIGNMENTS. ACCURATELY FORM INTERSECTIONS AND RETURNS. PERFORM CUTTING AND DRILLING OF TILE WITHOUT MARRING VISIBLE SURFACES. CAREFULLY GRIND CUT EDGES OF STONE ABUTTING TRIM, FINISH OR BUILT-IN ITEMS FOR STRAIGHT ALIGNED JOINTS. FIT STONE CLOSELY TO ELECTRICAL OUTLETS, PIPING, FIXTURES AND OTHER PENETRATIONS SO THAT PLATES, COLORS, OR COVERS OVERLAP TILE. JOINTING PATTERN: UNLESS OTHERWISE SHOWN, LAY STONE IN GRID PATTERN. ALIGN JOINTS WHEN ADJOINING TILES ON FLOOR, BASE, WALLS AND TRIM ARE SAME SIZE. LAYOUT TILE WORK AND CENTER TILE FIELDS IN BOTH DIRECTIONS IN EACH SPACE OR ON EACH WALL AREA. ADJUST TO MINIMIZE TILE CUTTING, PROVIDE UNIFORM JOINT WIDTHS, UNLESS OTHERWISE SHOWN. CLEANING: UPON COMPLETION OF PLACEMENT AND GROUTING, CLEAN ALL STONE TILE SURFACES SO THEY ARE FREE OF FOREIGN MATTER. UNGLAZED TILE MAY BE CLEANED WITH ACID SOLUTIONS ONLY WHEN PERMITTED BY TILE AND GROUT MANUFACTURER'S, PRINTED INSTRUCTIONS, BUT NOT SOONER THEN 14 DAYS AFTER INSTALLATION. PROTECT METAL SURFACES, CAST IRON AND VITREOUS PLUMBING FIXTURES FROM EFFECTS OF ACID CLEANING. FLUSH SURFACE WITH CLEAN WATER BEFORE AND AFTER CLEANING. FINISHED STONE TILE WORK: LEAVE FINISHED INSTALLATION CLEAN AND FREE OF CRACKED, CHIPPED, BROKEN UNBONDED, OR OTHERWISE DEFECTIVE TILE WORK. PROTECTION: WHEN RECOMMENDED BY STONE TILE MANUFACTURER, APPLY A PROTECTIVE COAT OF NEUTRAL PROTECTIVE CLEANER TO COMPLETED TILE WALLS AND FLOORS. PROTECT INSTALLED TILE WORK FROM OTHER HEAVY COVERING DURING CONSTRUCTION PERIOD TO PREVENT DAMAGE AND WEAR. PROHIBIT FOOT AND WHEEL TRAFFIC FROM USING STONE TILED FLOORS FOR AT LEAST THREE (3) DAYS AFTER GROUTING IS COMPLETED. BEFORE FINAL INSPECTION REMOVE PROTECTIVE COVERINGS AND RINSE NEUTRAL CLEANER FROM STONE TILE SURFACES. CONTRACTOR TO SUBMIT STONE TILE SAMPLE FOR ARCHITECT'S APPROVAL. « V V V V V r ♦ u r Y ♦ 4 • y V L 4 V { « « • • • • Y Y U U V V Y • ii •may . V V• 4 V V O V f V V V �•• y v Y• y Y Y • f V Y 4 V Y V y ♦ V V U V V V V U V V V Y U V V Y V f• f V V Y JV4 V JV V + • V V V� V V V V ". Y •i•f ,� X' • V V Y • * V V V 4 V V L V • V V V V i Y• ♦ V v V V V V V o f y Y �� V X1`20000522 ARCHITECTURE INTERIORDESIGN PLANNING SEAL' 71 Ilgt RONEY J. MATEU � AR 0008220 JMM CONSULTING ENGINEERS, LLC M.E.P. 12651 S DIXIE HIGHWAY, SUITE 209 MIAMI, FLORIDA 33156 M.A. SUAREZ CONSULTING ENGINEERS STRUCTURAL ENGINEERING 4869 SW 75TH AVENUE MIAMI, FLORIDA 33155 RISTORINO A ALAM CONSULTING ENG. INC. CIVIL ENGINEERING 7171 SW 62ND AVENUE, 4TH FLOOR MIAMI, FLORIDA 33143 OXFOR UNIVERSAL 4311 PONCE DE LEON BLVD. CORAL GABLES, FLORIDA 33146 5966 SOUTH DIXIE BUILDING 5966 &15970 SOUTH DIXIE HIGHWAY MIAMI, FLORIDA 33133 MATFU (ARCHITECTURE INC. THIS DRAWING IS THE PROPERTY OF MATEU AHCHITECTUHE INC. UNLESS OTHERWISE PROVIDED FOR NY CONTRACT THE CONTENTS OF THIS DRAWING ARE CONFIDENTIAL AND SHALL NOT GF', TRANSMITTED TO ANY PARTY EXCEPT AS AUTHORIZED WY THE ARCHITECT/ENGINEERS OF RECORD. PHASE PERMIT DRAWINGS FILE NAME: M:\0605\CD\SH EET\GINRL\G-005.DWG - - l PROJECT N0. MA0605 DRAWN NY' RAG CHECKED NY: RJM ISSUE DATE. DECEMBER 10, 2007 REVISIONS SHEET TITLE SPECIFICATIONS sIIEEr: i oF: G-105 6