08-40-030SAW CUT JOINTS WITHIN 24 HOURS AFTER PLACING. USE 1/8 INCH THICK BLADE MAX, CUT INTO 1/3 DEPTH OF SLAB THICKNESS. SCREEN SLABS ON GRADE LEVEL, MAINTAINING SURFACE FLATNESS OF MAXIMUM 1/8 INCH IN 10 FT (3 MM/3M). SPADE AND ROD CONCRETE TO EMBED ANCHORS, FIXTURES AND OTHER INSERTS FULLY IN DENSE CONCRETE. AT BOTTOM OF WALL POURS AND OTHER HORIZONTAL CONSTRUCTION JOINTS, ROUGHEN, CLEAN AND WET CONCRETE SURFACE AGAINST WHICH NEW CONCRETE IS TO BE PLACED. APPLY 1-1/2 INCHES OF GROUT JUST BEFORE PLACING NEW CONCRETE. THE GROUT IS THE SAME MIXTURE AS THE CONCRETE BUT WITH THE COARSE AGGREGATE OMITTED. CONCRETE FINISHING: FINISH CONCRETE FLOOR SURFACES IN ACCORDANCE WITH ACI 301. STEEL TROWEL SURFACES WHICH WILL RECEIVE CARPETING, RESILIENT FLOORING, THIN SET QUARRY OR CERAMIC TILE. STEEL TROWEL SURFACES WHICH ARE SCHEDULED TO BE EXPOSED. IN AREAS WITH FLOOR DRAINS, MAINTAIN FLOOR ELEVATION AT WALLS; PITCH SURFACES UNIFORMLY TO DRAINS AT 1/8 INCH PER FOOT (10 MM PER M) NOMINAL. CURING AND PROTECTION: IMMEDIATELY AFTER PLACEMENT, PROTECT CONCRETE FROM PREMATURE DYING, EXCESSIVELY HOT OR COLD TEMPERATURES, AND MECHANICAL INJURY. MAINTAIN CONCRETE WITH MINIMAL MOISTURE LOSS AT RELATIVE CONSTANT TEMPERATURE FOR PERIOD NECESSARY FOR HYDRATION OF CEMENT AND HARDENING OF CONCRETE. CURE FLOOR SURFACES IN ACCORDANCE WITH ACI 308 SPRAYING: SPRAY WATER OVER FLOOR SLAB AREAS AND MAINTAIN WET FO R 7 DAYS. FIELD QUALITY CONTROL: FIELD INSPECTION AND TESTING WILL BE PERFORMED IN ACCORDANCE WITH ACI 301 AND UNDER PROVISIONS OF SECTION 01410. PROVIDE FREE ACCESS TO WORK AND COOPERATE WITH APPOINTED FIRM. SUBMIT PROPOSED MIX DESIGN OF EACH CLASS OF CONCRETE TO INSPECTION AND TESTING FIRM FOR REVIEW PRIOR TO COMMENCEMENT OF WORK. PERFORM TESTS OF CEMENT AND AGGREGATES TO ENSURE CONFORMANCE WITH SPECIFIED REQUIREMENT. RECORD TEMPERATURE OF CONCRETE SAMPLE FOR EACH STRENGTH TEST AND ATMOSPHERIC TEMPERATURE AT THAT TIME. EXPOSURE TO THE ELEMENTS IN EXCESS OF 7 DAYS. IT SHOULD NOT BE USED AS A TEMPORARY WORKING SURFACE WITHOUT ADEQUATE SURFACE PROTECTION. THREE CONCRETE TEST CYLINDERS WILL BE TAKEN FOR EVERY 75 OR LESS CU YARDS OF EACH CLASS OF CONCRETE PLACED. ONE ADDITIONAL TEST CYLINDER WILL BE TAKEN DURING COLD WEATHER CONCRETING, CURED ON JOB SITE UNDER SAME CONDITIONS AS CONCRETE TAKEN. ONE AIR CONTENT TEST WILL BE TAKEN FOR EACH SET OF TEST CYLINDERS TAKEN. CONCRETE SEALER SECTION 00700 CONCRETE FLOORS: AS SHOWN ON DRAWINGS IN ALL AREAS SHOWN WITH SEALED CONCRETE FLOOR PROVIDE CONCRETE SEALER WITH SODIUM SILICATE AND PENETRATING SEALER WITH MAXIMUM OF 600 GRAMS/LITER. SELECT LOWEST VOC AVAILABLE. SUBMIT PRODUCT DATA TO ARCHITECT FOR APPROVAL. MASONRY SECTION 04200 PROVIDE ALL MASONRY UNITS IN SIZES AND SHAPES AS SHOWN ON THE DRAWINGS. CMU MORTAR TO CONFORM TO ASTM C-270 TYPE M UTILIZING THE PROPORTION METHOD TO ACHIEVE 2,500 PSI STRENGTH. COLOR TO MATCH ROCK FACE BLOCK. 1. CEMENTS: REPLACE PORTLAND CEMENT WITH COAL FLY ASH, MINIMUM 30%. 2. AGGREGATES: INDUSTRIAL WASTE BY-PRODUCTS: AIR COOLED SLAG, CINDERS, OR BOTTOM ASH; GROUND WASTE GLASS AND CONCRETE; GRANULATED SLAG; AND EXPANDED SLAG. REINFORCEMENT AND SINGLE WIDTH JOINT REINFORCEMENT: LADDER TYPE; HOT DIP GALVANIZED AFTER FABRICATION COLD - DRAWN STEEL CONFORMING TO ANSI/ASTM A82, 3/16INCH (4.8 MM) DEFORMED SIDE RODS WITH 1/8 INCH (3MM) CROSS TIES, IN ACCORDANCE WITH ACI 530.1-88 ASCE. REINFORCING STEEL: ASTM A615, 60 KSI YIELD GRADE, DEFORMED BILLET BARS UNFINISHED. STRAP ANCHORS; 'Z" - TYPE BENT STEEL SHARP, 1-1/2 X 24 INCH (40 X 610 MM) SIZE X 3/16 INCH (4.8 MM) THICK, GALVANIZED TO ASTM A153 CLASS B FINISH. GALVANIZED COATING REQUIREMENTS FOR METAL ACCESSORIES: METAL ACCESSORIES EMBEDDED IN MASONRY SHALL BE COATED FOR CORROSION PROTECTION COMPLYING WITH THE REQUIREMENTS OF ACI 530. 1-88/ASCE 6-88 (3.2.1.4) AS FOLLOWS: EXTERIOR WALL; GALVANIZED COATING SHALL CONFORM TO ASTM A153 CLASS B2 (1.5 OZ/SQ.FT. (460 G/SQ M). FLASHING: MEMBRANE FLASHINGS: COMPOSITE SHEET OF 32 MIL RUBBERIZED ASPHALT COMPOUND INTEGRALLY BONDED TO CROSS LAMINATED 8 MILL POLYETHYLENE; 40 MIL (0.5 MM) TOTAL THICKNESS; PERM -A- BARRIER MANUFACTURED BY W R GRACE do CO. ACCESSORIES: PERFORMED CONTROL JOINTS: POLYVINYLCHLORIDE MATERIAL. PROVIDE WITH CORNER AND TEE ACCESSORIES, CEMENT FUSED JOINTS. JOINT FILLER: CLOSED CELL POLYETHYLENE; OVERSIZED 50 PERCENT TO JOINT WIDTH; SELF EXPANDING; 3/4 INCH (20 MM) WIDE BY MAXIMUM LENGTHS. CELLULAR WEEP VENTS: MOLDED POLYVINYLCHLORIDE GRILLES: INSECT PROOF; #D/A 1006 MANUFACTURED BY DUR-O-WAL. CLEANING SOLUTIONS: NON --ACIDIC, NOT HARMFUL TO MASONRY WORK OR ADJACENT MATERIALS. PLACING AND BONDING: LAY MASONRY IN RUNNING BOND WITH FULL HEAD AND BED JOINTS. LAY TO PROVIDE NOT LESS THAN 1/3 OF A UNIT AT CORNERS. ALL JOINTS SHALL BE UNIFORM WIDTH AND THICKNESS. TOOL EXPOSED JOINTS TO UNIFORM FACE. INTERLOCK INTERSECTIONS AND EXTERNAL CORNERS. ISOLATE MASONRY PARTITIONS FROM VERTICAL STRUCTURAL MEMBERS WITH A CONTROL JOINT. ISOLATE TOP JOINT OF MASONRY FROM HORIZONTAL FRAMING MEMBERS, SLABS OR DECKS WITH COMPRESSIBLE JOINT FILLER. INSTALL WEEP HOLES IN VENEER AT 32 INCH ON CENTER ABOVE FLASHING, SHELF ANGLES, AND AT BOTTOM OF WALLS. INSTALL HORIZONTAL JOINT REINFORCEMENT 16 INCHES ON CENTER. PLACE JOINT REINFORCEMENT CONTINUOUS IN FIRST AND SECOND JOINT BELOW TOP OF WALLS. CLEAN ALL WORK THOROUGHLY USING NON-METALLIC BRUSHES AND CLEANING SOLUTION AND RINSE WITH WATER. ALL FINISHED SURFACES TO BE UNMARRED. STRUCTURAL STEEL SECTION 05120 THIS SECTION INCLUDES FABRICATION AND ERECTION OF STRUCTURAL STEEL WORK, AS SHOWN ON DRAWINGS INCLUDING SCHEDULES, NOTES, AND DETAILS SHOWING SIZE AND LOCATION OF MEMBERS, TYPICAL CONNECTIONS, AND TYPES OF STEEL REQUIRED. SHOP DRAWINGS PREPARED UNDER SUPERVISION OF A LICENSED STRUCTURAL ENGINEER, INCLUDING COMPLETE DETAILS AND SCHEDULES FOR FABRICATION AND ASSEMBLY OF STRUCTURAL STEEL MEMBERS, PROCEDURES, AND DIAGRAMS. INCLUDE DETAILS OF CUTS, CONNECTIONS, CAMBER, HOLES, AND OTHER PERTINENT DATA. INDICATE WELDS BY STANDARD AWS SYMBOLS AND SHOW SIZE, LENGTH, AND TYPE OF EACH WELD. PROVIDE SETTING DRAWINGS, TEMPLATES, AND DIRECTIONS FOR INSTALLATION OF ANCHOR BOLTS AND OTHER ANCHORAGES TO BE INSTALLED AS WORK OF OTHER SECTIONS. PROVIDE INDEPENDENT TEST REPORTS CONDUCTED OF SHOP AND FIELD BOLTED AND WELDED CONNECTIONS. INCLUDE DATA ON TYPES OF TESTS CONDUCTED. QUALITY ASSURANCE CODES AND STANDARDS: COMPLY WITH PROVISIONS OF FOLLOWING, EXCEPT AS OTHERWISE INDICATED: AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES." "SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A 325 OR A 490 BOLTS" APPROVED BY THE RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS. AMERICAN WELDING SOCIETY (AWS) D1.1 "STRUCTURAL WELDING CODE - STEEL." ASTM A 36 "GENERAL REQUIREMENTS FOR DELIVERY OF ROLLED STEEL PLATES, SHEET PILING AND BARS FOR STRUCTURAL USE." QUALIFICATIONS FOR WELDING WORK: QUALIFY WELDING PROCEDURES AND WELDING OPERATIORS IN ACCORDANCE WITH AWS "QUALIFICATION" REQUIREMENTS. STORE MATERIALS TO PERMIT EASY ACCESS FOR INSPECTION AND IDENTIFICATION. KEEP STEEL MEMBERS OFF GROUND BY USING PALLETS, PLATFORMS, OR OTHER SUPPORTS. PROTECT STEEL MEMBERS AND PACKAGED MATERIALS FROM EROSION AND DETERIORATION. IF BOLTS AND NUTS BECOME DRY OR RUSTY, CLEAN AND RELUBRICATE BEFORE USE.. METAL SURFACES, GENERAL: FOR FABRICATION OF WORK THAT WILL BE EXPOSED, USE ONLY MATERIALS THAT ARE SMOOTH AND FREE OF SURFACE BLEMISHES INCLUDING PITTING, RUST AND SCALE SEAM MARKS, ROLLER, ROLLED TRADE NAMES, AND ROUGHNESS. REMOVE SUCH BLEMISHES BY GRINDING, PRIOR TO CLEANING, TREATING, AND APPLYING SURFACE FINISHES. HEADED STUD -TYPE SHEAR CONNECTORS: ASTM A 108, GRADE 1015 OR 1020, COLD- FINISHED CARBON STEEL WITH DIMENSIONS COMPLYING WITH AISC SPECIFICATIONS. ACHOR BOLTS: ASTM A 307, NONHEADED TYPE UNLESS OTHERWISE INDICATED. HIGH -STRENGTH THREADED FASTENERS: HEAVY HEXAGON STRUCTURAL BOLTS, HEAVY HEXAGON NUTS, AND HARDENED WASHERS COMPLYING W/ ASTM A 325. ELECTRODES FOR WELDING: COMPLY WITH AWS CODE, E70XX STRUCTURAL STEEL PRIMER PAINT: FABRICATOR'S STANDARD RUST -INHIBITING PRIMER. CEMENT GROUT: PORTLAND CEMENT )ASTM C 150, TYPE i OR TYPE iii) AND CLEAN, UNIFORMLY GRADED, NATURAL SAND (ASTM C 404, SIZE NO. 2). MIX AT A RATIO OF 1.0 PART CEMENT TO 3.0 PARTS SAND, BY VOLUME, WITH MINIMUM WATER REQUIRED FOR PLACEMENT AND HYDRATION. WELDED CONSTRUCTION: COMPLY WITH AWS CODE FOR PROCEDURES, APPEARANCE AND QUALITY OF WELDS, AND METHODS USED IN CORRECTING WELDING WORK. GAS CUTTING: DO NOT USE GAS CUTTING TORCHES IN FIELD FOR CORRECTING FABRICATION ERRORS IN PRIMARY STRUCTURAL FRAMING. CUTTING WILL BE PERMITED ONLY ON SECONDARY MEMBERS THAT ARE NOT UNDER STRESS, AS ACCEPTABLE TO ARCHITECT. FINISH GAS -CUT SECTIONS EQUAL TO A SHEARED APPEARANCE WHEN PERMITTED. TOUCH-UP PAINTING: IMMEDIATELY AFTER ERECTION, CLEAN FIELD WELDS, BOLTED CONNECTIONS, AND ABRADED AREAS OF SHOP PAINT. APPLY PAINT TO EXPOSED AREAS USING SAME MATERIAL AS USED FOR SHOP PAINTING. METAL FRAMING SECTION 05400 MATERIALS ALL STUD FRAMING MEMBERS SHALL BE OF THE TYPE, SIZE AND GAGE AS SHOWN ON THE PLANS AND SPECIFIED HEREIN. ALL FRAMING COMPONENTS SHALL BE CUT SQUARELY FOR ATTACHMENT TO PERPENDICULAR MEMBERS, OR AS REQUIRED FOR AN ANGULAR FIT AGAINST ABUTTING MEMBERS. MEMBERS SHALL BE HELD POSITIVELY IN PLACE UNTIL PROPERLY FASTENED. INSTALLATION TRACKS SHALL BE SECURELY ANCHORED TO THE SUPPORTING STRUCTURES AS SHOWN. FLOOR TRACKS SHALL RECEIVE CONTINUOUS SILICON SEALANT EACH SIDE OF THE TRACK BEFORE INSTALLATION OF WALL SHEATHING/FINISH MATERIAL. AT TRACK BUTT JOINTS, ABUTTING PIECES OF TACK SHALL BE SECURELY ANCHORED TO A COMMON STRUCTURAL ELEMENT, OR THEY SHALL BE BUTT WELDED OR SPLICED TOGETHER. STUDS SHALL BE PLUMBED, ALIGNED AND SECURELY ATTACHED TO THE FLANGES OR WEBS OF BOTH UPPER AND LOWER TRACKS. STUDS SHALL BE INSTALLED AT 16" ON CENTER UNLESS OTHERWISE NOTED ON THE PLANS. WALL STUD BRIDGING SHALL BE ATTACHED IN A MANNER TO PREVENT STUD ROTATION. BRIDGING ROWS SHALL BE SPACED ACCORDING TO THE FOLLOWING SCHEDULE. WALLS UP TO 10'-0" HEIGHT: BRIDGING AT MID- HEIGHT WALLS EXCEEDING 10'-0" HEIGHT: BRIDGING ROWS SPACED NOT TO EXCEED 5'-0" 0. C. METAL FABRICATIONS SECTION 05500 MATERIALS: LIMIT MATERIALS THAT WILL BE EXPOSED TO VIEW TO THOSE WHICH ARE FREE FROM SURFACE BLEMISHED, PITTING, ROLLED TRADE NAMES, AND ROUGHNESS. PROVIDE STEEL PLATE, SHAPES AND BARS MEETING ASTM A36, STEEL PIPE MEETING ASTM A53 -GRADE A SCHEDULE 40, AND STEEL TUBE MEETING ASTM A500. PROVIDE BENT OTHERWISE CUSTOM FABRICATED BOLTS, PLATES, ANCHORS, HANGERS, DOWELS AND OTHER MISCELLANEOUS STEEL AND IRON SHAPES AS REQUIRED FOR FRAMING, SUPPORTING OR ANCHORING. FABRICATION AND INSTALLATION SHALL CONFORM TO THE LATEST AISC SPECIFICATIONS. FORM WORK TRUE TO LINE AND LEVEL WITH ACCURATE ANGELS AND SURFACES. EASE EXPOSED EDGES TO A RADIUS OF APPROX. 14" UNLESS OTHERWISE SHOWN. WELD CORNERS AND SEAMS CONTINUOUSLY, COPING CONNECTIONS, UNLESS OTHERWISE INDICATED. GRIND EXPOSED WELDS SMOOTH AND FLUSH TO MATCH AND BLEND WITH ADJOINING SURFACES. PRIME WITH RED OXIDE PRIMER AND TOUCH-UP AT SITE. INSTALLATION: INSTALL ITEMS PLUMB AND LEVEL, ACCURATELY FITTED, FREE FROM DISTORTION OR DEFECTS. ALLOW FOR ERECTION LOADS, AND FOR SUFFICIENT TEMPORARY BRACING TO MAINTAIN TRUE ALIGNMENT UNTIL COMPLETION OF ERECTION AND INSTALLATION OF PERMANENT ATTACHMENTS. FIELD WELD COMPONENTS INDICATED ON DRAWINGS. PERFORM FIELD WELDING IN ACCORDANCE WITH AWS D1.1 OBTAIN ARCHITECT/ENGINEER APPROVAL PRIOR TO SITE CUTTING OR MAKING ADJUSTMENTS NOT SCHEDULED. AFTER ERECTION PRIME WELDS, ABRASIONS, AND SURFACES NOT SHOP PRIMED, EXCEPT SURFACES TO BE IN CONTACT WITH CONCRETE. WOOD TREATMENT SECTION 06070 1.01 SUBMITTALS: A. PROVIDE DATA: SUBMIT PRODUCT DATA ON WOOD PRESERVATIVE MATERIALS, INCLUDING APPLICATION INSTRUCTIONS. 1.02 CODES AND STANDARDS A. OBTAIN APPROVALS FROM BUILDING OFFICIAL FOR ALTERNATIVE WOOD PRESERVATIVE TREATMENT. 1.03 ENVIRONMENTAL QUALITY ASSURANCE A. PRESERVATIVE SHALL BE ADEQUATELY FIXED IN THE WOOD. REJECT LUMBER WITH SURFACE RESIDUES OF WHITE SALTS. WOOD THAT IS KILN -DRIED AFTER TREATMENT AND/OR PREFINISHED WITH A SEALER IS PREFERABLE. PRODUCTS 2.01 PEST AND ROT CONTROL A. NEW CONSTRUCTION 1. SODIUM SILICATE WOOD MINERALIZATION PROCESS (AVAILABLE FOR INTERIOR, EXTERIOR USE, AND GROUND CONTACT.) 2. BORON -BASED PRESERVATIVE: LIMITED TO ABOVE -GROUND USE. ROUGH CARPENTRY SECTION 06100 PROVIDE AND INSTALL BLOCKING, BACKING, PLYWOOD, SHEATHING, FURRING AND MISCELLANEOUS LIGHT FRAMING REQUIRED FOR COMPLETION OF THE WORK, WHICH IS GENERALLY NOT EXPOSED; WHERE NOTED ON THE DRAWINGS, AND AS SPECIFIC HEREIN. PLYWOOD BLOCKING IN PARTITIONS do MOUNTING PANELS FOR MOUNTING EQUIPMENT. PROVIDE PLYWOOD APA C -D PLUGGED INT WITH EXTERIOR GLUE WITH LOW VOCs. MISC. WOOD FRAMING & BLOCKING: CONSTRUCTION GRADE #2 OR BETTER DOUGLAS FIR OR EQUAL, S4S, FIRE -RETARDANT TREATED UNLESS OTHERWISE INDICATED. MICRO -LAM LUMBER: BEAMS AND HEADERS AS SCHEDULED. SEE DRAWING FOR DESIGN STRESSES. FIRE -RETARDANT TREATED WOOD PROVIDE FIRE -LABELED WOOD WITH MINIMUM FLAME SPREAD RATING OF 25 (UL FR -S), AT THE FOLLOWING LOCATIONS: (1) BLOCKING CONCEALED WITHIN METAL FRAMED DRYWALL PARTITIONS IN NON-COMBUSTIBLE CONSTRUCTION; (2) FRAMING do BLOCKING LOCATED ABOVE FINISHED CEILINGS; AND (3) BLOCKING WITHIN FIRE -RATED WALLS. PRESERVATIVE TREATMENT: PROVIDE PRESERVATIVE TREATED WOOD WHERE INDICATED IN THE DRAWINGS AND AS FOLLOWS: WOOD CANTS, NAILERS, CURBS, BLOCKING, STRIPPING AND SIMILAR MEMBERS IN CONNECTION WITH ROOFING; AND WOOD WILLS SLEEPERS, BLOCKING, STRIPPING AND SIMILAR CONCEALED MEMBERS IN CONTACT WITH MASONRY OR CONCRETE. PRESERVATIVE TREATMENT SHALL BE WATER BORNE MATERIAL COMPLYING WITH AWPB LP --2, KILN -DRIED TO 19% MAXIMUM MOISTURE CONTENT FOR LUMBER AND 15% FOR PLYWOOD. INSTALLATION: SET ROUGH CARPENTRY ACCURATELY TO REQUIRED LEVELS AND LINES, WITH MEMBERS PLUMB AND TRUE AND ACCURATELY CUT AND FITTED. SECURELY ATTACH WORK TO SUBSTRATE. SHEATHING: PLACE ROOF AND WALL SHEATHING WITH END JOINTS, STAGGERED. SECURE SHEETS OVER FIRM BEARING. MAINTAIN MINIMUM 1/16 INCH AND MAXIMUM 1/8 INCH SPACING BETWEEN JOINTS OF SHEETS ON WALLS. PLACE PERPENDICULAR TO FRAMING MEMBERS. 1.01 SUBMITTALS A. SUBMIT PRODUCT DATA ON WOOD PRESERVATIVE MATERIALS, INCLUDING APPLICATION INSTRUCTIONS. B. SUBMIT INVOICES SHOWING THE VENDOR'S FOREST STEWARDSHIP COUNCIL CHAIN -OF -CUSTODY CERTIFICATE NUMBER AND IDENTIFYING FSC -CERTIFIED PRODUCTS ON AN ITEM -BY -ITEM BASIS AS DOCUMENTATION THAT AN FSC -ACCREDITED ORGANIZATION HAS CERTIFIED THAT THE WOOD OR WOOD PRODUCTS ARE FROM A WELL-MANAGED FOREST. 1.02 DELIVERY, STORAGE, AND HANDLING A. PROTECT FRAMING LUMBER, SHEATHING, AND ENGINEERED WOOD PRODUCTS FROM EXCESSIVE HUMIDITY AND MOISTURE. STORE WOOD I -BEAMS, FLINCH BEAMS, AND JOIST ON EDGE. PRODUCTS 2.01 MATERIALS A. CERTIFIED DIMENSIONAL LUMBER: FSC -CERTIFIED, SUBJECT TO APPROVAL BY STRUCTURAL ENGINEER. B. ENGINEERED WOOD PRODUCTS: 1. WOOD I -BEAMS: JOISTS, RAFTERS; TO BE FSC -CERTIFIED, SUBJECT TO APPROVAL BY STRUCTURAL ENGINEER. 2. WOOD TRUSSES: TO BE CONSTRUCTED OF FSC -CERTIFIED LUMBER, SUBJECT TO APPROVAL BY STRUCTURAL ENGINEER. D. SHEET MATERIALS: 1. ORIENTED -STRAND BOARD (OSB): FSC -CERTIFIED 2. PLYWOOD: FSC -CERTIFIED 3. STRUCTURAL FIBERBOARD: MANUF. FROM 100% POST -CONSUMER NEWSPRINT 4. MEDIUM DENSITY FIBERBOARD: FORMALDEHYDE -FREE, MANUFACTURED WITH PMDI BINDERS 5. PARTICLE BOARD: a. STRAW -BASED PARTICLEBOARD: MANUFACTURED WITH PMDI BINDERS b. FSC -CERTIFIED PARTICLE BOARD 6. STRUCTURAL INSULATED PANELS (SIPS): OSB SKIN BONDED TO EXPANDED POLYSTYRENE OR AGFIBER CORE 7. RADIANT BARRIER SHEET MATERIAL: FOIL FACED PLYWOOD, OSB, OR RECYCLED PAPER. E. ROT AND INSECT -RESISTANT WOOD: 1. UNTREATED, NATURALLY ROT -RESISTANT, HEART WOOD -INCLUDING, BUT NOT LIMITED TO, REDWOOD, WESTERN RED CEDAR, BALD CYPRESS, LONGLEAF YELLOW PINE, ELM, BLOCK LOCUST, AMERICAN CHESTNUT, AND ANGICO-FROM ONE OF THE FOLLOWING SOURCES: a. FSC -CERTIFIED b. SALVAGED 2. PRESSURE -TREATED WOOD FSC -CERTIFIED: MINIMIZE CUTTING, AVOID BREATHING SAWDUST. a. ACQ-AMMONIACAL COPPER QUARTERNARY COMPOUND: PRESSURE -INJECTED WOOD THAT DOES NOT USE ARSENIC OR CHROMIUM 1. ABOVE -GROUND: 0.25 LBS. RETENTION/CU. FT. 2. GROUND CONTACT: 0.40 LBS. RETENTION/CU, FT. 3. WOOD FOUNDATIONS: 0.60 LBS. RETENTION/CU. FT. 4. PILINGS: 0.80 TO 1.0 LBS. RETENTION/CU. FT. b. BORATE: FRAMING LUMBER AND PLYWOOD PRESSURE TREATED WITH SODIUM BORATE AND OSB SHEATHING PRODUCTS WITH INTEGRAL ZINC BORATE RECENTLY INTRODUCED; APPROPRIATE FOR INTERIOR APPLICATIONS -DO NOT USE WHERE EXPOSED WEATHER OR GROUND CONTACT. c. SODIUM SILICATE WOOD MINERALIZATION PROCESS: FRAMING LUMBER AND PLYWOOD PRESSURE -AND HEAT-TREATED WITH SODIUM SILICATE RECENTLY INTRODUCED; APPROPRIATE FOR INTERIOR AND EXTERIOR APPLICATIONS, INCLUDING GROUND CONTACT; NOT YET LISTED WITH THE ICC. 2.02 RELATED MATERIALS A. FASTENERS: USE HIGHEST RECYCLED -CONTENT STEEL AVAILABLE, FOR ACQ OR COPPER AZOLE; USE ONLY STAINLESS STEEL OR HOT -DIP GALVANIZED FASTENERS. B. CONSTRUCTION ADHESIVES: WATER BASED, MAXIMUM VOCs: 15 GRAMS/LITER C. BUILDING FELT: MINIMUM 30% RECYCLED FIBER CONTENT D. SILL SEALER: FOAM SEALER TO MATCH WIDTH OF SILL PLATE PART 3 EXECUTION 3.01 INSTALLATION A. PROTECT FRAMING, JOIST AND SHEATHING FROM MOISTURE DURING DELIVERY, INSTALLATION, AND USE. B. USE ADVANCED -FRAMING TECHNIQUES DEVELOPED BY THE NATIONAL ASSOCIATION OF HOME BUILDERS RESEARCH CENTER. COMPLY WITH STRUCTURAL LOADING REQUIREMENTS OF UBC AND STRUCTURAL ENGINEER. WASTE MANAGEMENT: A. SEPARATE WOOD WASTE IN ACCORDANCE WITH THE WASTE MANAGEMENT PLAN. B. SEPARATE THE FOLLOWING CATEGORIES FOR SALVAGE OR REUSE ON SITE: 1. SHEET MATERIALS LARGER THAN 2 SQ. FT. 2. FRAMING MEMBERS LARGER THAN 16" 3. MULTIPLE OFFCUTS OF ANY SIZE LARGER THAN 12" C. SET ASIDE DAMAGED WOOD FOR ACCEPTABLE ALTERNATIVE USES; FOR EXAMPLE, USE AS BRACING, BLOCKING, CRIPPLES, OR TIES. D. DO NOT BURN LUMBER THAT IS LESS THAN A YEAR OLD. E. SEPERATE THE FOLLOWING CATEGORIES FOR DISPOSAL AND PLACE IN DESIGNATED AREAS FOR HAZARDOUS MATERIAL: 1. TREATED, STAINED, PAINTED, OR CONTAMINATED WOOD F. SEQUENCE WORK TO MINIMIZE USE OF TEMPORARY HVAC TO DRY OUT BUILDING AND CONTROL HUMIDITY. FINISH CARPENTRY SECTION 06200 PROVIDE MISCELLANEOUS FINISH CARPENTRY ITEMS AS SHOWN ON THE DRAWINGS. INSTALLATION: INSTALL WORK PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. SHIM AS REQUIRED USING CONCEALED SHIMS. SCRIBE AND CUT TO FIT ADJOINING WORK. INSTALL WITH MINIMUM NUMBER OF JOINTS POSSIBLE, USING FULL-LENGTH PIECES TO THE GREATEST EXTENT POSSIBLE. COPE AT RETURNS, MITER AT CORNERS, AND USE SCARF JOINTS FOR END-TO-END JOINTS TO PROVIDE TIGHT FITTING JOINTS WITH FULL SURFACE CONTACT THROUGHOUT LENGTH OF JOINT. ANCHOR TO BLOCKING OR DIRECTLY TO SUBSTRATE WITH COUNTERSUNK, CONCEALED FASTENERS AND BLIND NAILING WHERE POSSIBLE. ANCHOR COUNTERTOPS SECURELY TO SUPPORT SYSTEMS AS INDICATED. AT DRYWALL PARTITIONS, WHERE BLOCKING DOES NOT EXIT, USE ADHESIVE AND PRE -DRILLED COUNTERSUNK TRIM -HEAD SHEET -METAL SCREWS TO ATTACH FINISH CARPENTRY TO METAL STUDS. FILL RECESS TO MATCH SURFACE COLOR OF WOOD. 1.02 INDOOR AIR QUALITY A. SOME ENGINEERED WOOD PRODUCTS MADE WITH INTERIOR GLUES CONTAIN UREA -FORMALDEHYDE. DO NOT USE WOOD PRODUCTS CONTAINING UREA -FORMALDEHYDE BINDERS. OR SEAL ALL SURFACES. B. MACHINING PLASTIC PRODUCTS PRODUCES HAZARDOUS DUST. PROTECT SURROUNDING AREAS FROM DUST. WEAR APPROPRIATE PROTECTION. PART 2 PRODUCTS 2.01 INTERIOR MILLWORK A. BASE, CASING, TRIM INTERIOR RAIL AND WALL CAPS, AND MISCELLANEOUS MILLWORK: 1. MATERIALS SUITABLE FOR CLEAR FINISH: a. FSC -CERTIFIED, SOLID DIMENSIONAL LUMBER b. SALVAGED, REMILLED LUMBER B. PANELING 1. PLYWOOD: a. FSC -CERTIFIED PLYWOOD b. FSC -CERTIFIED FACE VENEERS OVER FORMALDEHYDE -FREE MDF CORE C. VENEER PANELS: 1. SUBSTRATE a. FORMALDEHYDE -FREE MDF b. STRAWBOARD: PARTICLEBOARD MADE FROM STRAW WITH PMDI BINDERS 2. VENEERS. FSC -CERTIFIED 2.02 EXTERIOR MILLWORK A. FASCIA, TRIM, SIDING, FENCING, LATTICE, AND MISCELLANEOUS MILLWORK: 1. DIMENSIONAL LUMBER: a. ROT -RESISTANT SPECIES SUCH AS CEDAR OR CYPRESS LOCALLY AVAILABLE, ROT -RESISTANT SPECIES, FSC -CERTIFIED CUSTOM CASEWORK SECTION 06400 PROVIDE SHOP -FABRICATED WOOD CASEWORK, FURNITURE ITEMS, AND MISCELLANEOUS ITEMS AS INDICATED IN THE DRAWINGS. QUALITY ASSURANCE: COMPLY WITH AWI "QUALITY STANDARDS" SECTION 400 FOR "CUSTOM" GRADE. SUBMIT SHOP DRAWINGS TO SHOW LOCATION OF EACH ITEM, DIMENSIONED PLANS AND ELEVATIONS, LARGE SCALE DETAILS, ATTACHMENTS DEVICES AND OTHER COMPONENTS. THE ARCHITECT'S REVIEW OF SUCH DRAWINGS WILL BE FOR DESIGN CONFORMANCE ONLY. VERIFY FIELD MEASUREMENTS AND PROVIDE DIMENSIONS FOR SHOP DRAWINGS BEFORE FABRICATION. CASEWORK MATERIALS: SHALL BE AS SHOWN ON THE MILLWORK DRAWINGS. GENERAL FABRICATION & ASSEMBLY: SHOP FABRICATE CASEWORK TO DIMENSIONS, PROFILES, AND DETAILS INDICATED ON SHOP DRAWINGS. WHERE NECESSARY FOR FITTING AT SITE, PROVIDE AMPLE ALLOWANCE FOR SCRUBBING, TRIMMING, AND FITTING. COMPLETE FABRICATION, FINISHING, HARDWARE APPLICATION AND OTHER WORK BEFORE SHIPMENT TO PROJECT SITE TO MAXIMUM EXTENT POSSIBLE. SHOP ASSEMBLY: COMPLETELY ASSEMBLE COUNTERFRONT, CABINETS, COUNTERTOPS, POSTS, AND GLAZING IN SHOP PRIOR TO SHIPMENT TO PROJECT SITE. MAKE INDIVIDUAL ITEMS IN SEQUENCE WITH REMOVABLE MATERIALS TO FACILITATE FIELD ASSEMBLY. FIELD INSTALLATION: INSTALL CASEWORK PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. SHIM AS REQUIRED USING CONCEALED SHIMS. INSTALL TO A TOLERANCE OF 1/8" IN 8'-0" FOR PLUMB AND LEVEL AND WITH NO VARIATIONS IN FLUSHNESS OF ADJOINING SURFACES. SCRIBE AND CUT TO FIT ADJOINING WORK. ANCHOR TO BLOCKING OR DIRECTLY TO SUBSTRATES WITH DISTORTION SO THAT CABINET DOORS FIT OPENINGS PROPERLY AND ARE ACCURATELY ALIGNED. ADJUST HARDWARE TO CENTER DOORS IN OPENINGS AND TO PROVIDE FREE OPERATION. ANCHOR COUNTERTOPS SECURELY TO BASE UNITS AND OTHER SUPPORT SYSTEMS AS INDICATED. ADJUST AND CLEAN: REPAIR DAMAGED AND DEFECTIVE CASEWORK WHERE POSSIBLE TO ELIMINATE DEFECTS, WHERE NOT POSSIBLE TO REPAIR, REPLACE CASEWORK. CLEAN, LUBRICATE AND ADJUST HARDWARE FOR SMOOTH OPERATION. A. CARCASSES AND SUBSTRATES: 1. MEDIUM -DENSITY FIBERBOARD: FORMALDEHYDE -FREE 2. FSC -CERTIFIED PLYWOOD 3. SOLID DIMENSIONAL LUMBER: FSC -CERTIFIED 4. AG -FIBER BOARD: FORMALDEHYDE -FREE B. FACE FRAMES, DOORS, DRAWERS: 1. SOLID DIMENSIONAL LUMBER: FSC -CERTIFIED OR SALVAGED 2. VENEERS: WOOD: FSC -CERTIFIED MISCELLANEOUS MATERIALS A. ADHESIVES: 1. INTERIOR WOODWORK AND MILLWORK: LOW-VOC, FS MMM -A -125C, TYPE II, WATER -AND MOLD RESISTANT. USE ASTM D3110, DRY -USE TYPE FOR LAMINATED AND FINGER -JOINTED MEMBERS, CERTIFIED IN ACCORDANCE WITH ASTM C557 AND COMPLYING WITH REQUIRED VOC REGULATIONS. a. WATER-BASED CONTACT CEMENT b. WATER-BASED CONSTRUCTION ADHESIVES 2. EXTERIOR MILLWORK: ANSI/HPMA HP1983, TYPE I, AIR -CURE WATERPROOF TYPE. USE ASTM D3110, WET -USE TYPE FOR LAMINATED AND FINGER -JOINTED MEMBERS. WASTE MANAGEMENT A. SEPARATE WOOD WASTE IN ACCORDANCE WITH THE WASTE MANAGEMENT PLAN. B. SEPARATE THE FOLLOWING CATEGORIES FOR SALVAGE OR REUSE ON SITE: 1. SHEET MATERIALS LARGER THAN 2 SF 2. SOLID WOOD: a. TRIM LONGER THAN 16" b. MULTIPLE OFFCUTS OF ANY SIZE LARGER THAN 12" C. RECYCLE THE FOLLOWING CATEGORIES: 1. CLEAN, UNPAINTED ENGINEERED WOOD PRODUCTS 2. CLEAN, UNPAINTED DIMENSIONAL LUMBER D. SEPARATE THE FOLLOWING CATEGORIES FOR DISPOSAL AND PLACE IN DESIGNATED AREAS FOR HAZARDOUS MATERIALS: 1. TREATED, STAINED, PAINTED, OR CONTAMINATED WOOD. BUILDING INSULATION SECTION 07200 PROVIDE AND INSTALL RIGID BOARD WALL INSULATION WITH VAPOR BARRIER, WHERE INDICATED ON THE DRAWINGS AND AS SPECIFIED HEREIN. GLASS FIBER BLANKET BATT INSULATION: GLASS FIBERS FORMED WITH BINDERS INTO RESILIENT FLEXIBLE BLANKETS OR SEMI-RIGID BUTTS; ASTM C665 TYPES 1,11, OR 111, UNFACED OR FACED UNITS AS INDICATED, DENSITIES OF NOT LESS THAN 0.5 LB. PER CU. FT., K- VALUE OF 0.27; MANUFACTURER'S STANDARD LENGTHS AND WIDTHS AS REQUIRED TO COORDINATE WITH SPACES TO BE INSULATED. POLYETHYLENE VAPOR BARRIER: 6 -MIL POLYETHYLENE FILM INSTALL INSULATION IN FULL THICKNESS AS SHOWN OVER ENTIRE AREA TO BE INSULATED. CUT AND FIT TIGHTLY AROUND OBSTRUCTIONS, AND FILL VOIDS WITH INSULATION. REMOVE PROJECTIONS WHICH INTERFERE WITH PLACEMENT. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. MATERIALS A. THERMAL BATT INSULATION 1. FORMALDEHYDE -FREE FIBERGLASS BATTS: MADE WITH LOWER TOXICITY ACRYLIC RESIN. 2. STANDARD GLASS FIBER: MINIMUM 15% POST -CONSUMER RECYCLED CONTENT, MINIMUM 30% TOTAL RECYCLED CONTENT 3. FACING: a. FOIL: PROVIDE RADIANT BARRIER PROTECTION FROM GLASS FIBERS b. KRAFT PAPER c. ENCAPSULATED: PROVIDES PROTECTION FROM GLASS FIBERS d. UNFACED: USE FOR SOUND INSULATION OR WHEN A SEPARATE VAPOR RETARDER IS USED. B. RIGID BOARD INSULATION 1. CELLULAR GLASS FOAM: INERT, NONTOXIC, SUITABLE FOR USE BELOW GRADE. 2.EXPANDED POLYSTYRENE: RECYCLED CONTENT MINIMUM 20% 3.EXTRUDED POLYSTYRENE: 5% RECYCLED CONTENT METAL ROOF PANELS SECTION 07500 PART 1 - GENERAL 1.01 QUALITY ASSURANCE A. MINIMUM 20 -YR PRODUCT WARRANTY FOR FINISH. 1.02 SUBMITTALS B. SUBMIT DOCUMENTATION THAT PRODUCTS MEET ENERGY STAR COOL ROOF REQUIREMENTS AND HAVE A EMISSIVITY OF NO LESS THAN 0.9. PART 2 - PRODUCTS 2.01 MATERIALS A. ALUMINUM PANEL: MINIMUM 75% RECYCLED CONTENT 1. ARCHITECTURAL GRADE: 0.040" TO 0.125" 2. STRUCTURAL GRADE: 0.040" TO 0.125" 3. FINISH: MANUFACTURES RECOMMENDATION B. FELT UNDERLAYMENT: MINIMUM 30% RECYCLED FIBER CONTENT C. FLASHING: SAME MATERIAL AS ROOFING OR MATERIAL COMPATIBLE WITH ROOFING; AVOID NONCOMPATIBLE OR DISSIMILAR METALS DUE TO RISK OF GALVANIC CORROSION. •V V y V Y V• V V V .. y V V V 4 v y 4 4 V V V V ••! 4• v 4 V W V v V V 4 •' ! y � 4 V VV4•V !!«y v«• v 4 • . #26000522 • V V V 4 v to 4 y V V ! • V VV � V V Y • • V V V « V V V V « V 4 V V y « � ` ` V V V V • V V V 4•• •• V V V• U V v 0 V • ••!• vu 4 • V u ! • ; 4 y y V • p V 4 iY fitV V • 4 V V 4 4 y V V V V V V ! yv V 4 n .r r 4 S U t� M T �A Y. n F_ F- t S .f� W F In ry m Q R m w U m S., N .n ti 6 U ,t � n U O U Lu ARCHITECTURE INTERIOR DESIGN PLANNING RONEY J. MATEU AR 0008220 JMM CONSULTING ENGINEERS, LLC M.E.P. 12651 S DIXIE HIGHWAY, SUITE 209 MIAMI, FLORIDA 33156 M.A. SUAREZ CONSULTING ENGINEERS STRUCTURAL ENGINEERING 4569 SW 75TH AVENUE MIAMI, FLORIDA 33155 FISTORINO & ALAM CONSULTING ENG. INC. CIVIL ENGINEERING 7171 SW 62ND AVLNUL, 41H FLOOR MIAMI, FLORIDA 33143 OXFORD UNIVERSAL 4311 PONCE DE LEON BLVD. CORAL GABLES, FLORIDA 33146 5966 SOUTH DIXIE BUILDING 5966 & 5970 SOUTH DIXIE HIGHWAY MIAMI, FLORIDA 33133 MATED ARCHITFCTORE INC THIS DRAWING IS THE PROPERTY OF MATEU ARCHITECTURE INC UNLESS OTHERWISE PROVIDED FOR MY CONTRACT THE CONTENTS OF THIS DRAWING ARE CONFIDENTIAL AND SHALL NOT OFTRANSMITTED TO ANY PARTY EXCEPT AS AUTHORIZED OY THE ARCHITECT/ETVGINEERS OF RECORD PHASE PERMIT DRAWINGS FILE NAME: IM:\0605\C'D\SH E ET\GINRL\G-004.DWG PROJECT NO MA0605 DRAWN RY: RAG CHECKED RY RJM ISSUE DATE: DECEM4ER 10, 2007 REVISIONS SHEET TITLE SPECIFICATIONS SHEET: OF G-004 6