Loading...
08-40-015R/W 'LINE-�'� ,. �5 ' S I DQE W A L It CURB do GUTTER GV GV - - --` D4 / - - ✓ 12" DIP 1'v'ivl---�- ---- --•- / , OO rL0 F / 1rL`L PL I -�Q•�C VCR SAN - SAN MF�, RIM 12.20 SAN MH INV 5.� E, 5.85S S W 73rd I I S T. / SCALE, T'= 20' , •Y M :.. R/W LINE =�, ' .. W R/N1 LINE - a, / -�•- - ------ �. .•� � �\ GV SIGN / SMH RI 12.10 / / .. �\ j's' INV EL 60S, �� T O \O 7.50E. I I �\ q. L6, 11.60 0 1j01k� X10 M 04/ t p / \;�\ .. / o �G 5\° �� ..:::. / z III wM 4L LLJfl V. .., '..OF' X G 0 6 e, dl I I I I wM G O • �Q 1. � � oyer yo ( goo IL SITE WM SITE DATA .,.I I N I 0dj WM / GJ 0 �2 sO.. o1\1 TOTAL SITE AREA:...............31,111 S.F. 71 U y ,� IMPERV. IBL DG. AREA: ....... .29,002 S.F. s �11 1�. a ' $ O \ PER VIOUS AREA:..................2,109 S F. i d/, .; / T .. ,p , / Q SAN. LAT. �tN :N'ISA L T. a 5�1... .. � � .. /OAR PARKING METER `" TYPICAL 011 � � 11� ` ' I Z FH (P.B. 7. PG 11 } II;I I U _ 11, BOCK � ,VIII � LOT. LO � . I /Nb / MATCH EXIST. CONC.'r ASPHA.LY BARKING.SDWK./C.dtG ELEVS �.:.r �1 �1' U SAN. LA�f. 0 Y 10.5 ' .CURB �' A WM J U 0 h L I \ \ os z ( I PARKING METER , l a Ld , o� v`'i I (TYPICAL) \ m �O C� I o / � �b• n \ ,� � ,/.-,,,, I o o �� I ,�_ I ods ,� k6 \ M g.' 4! 00 c w b/ P �-y. \ \ \ �p �O\ `+," } : 4? NEW 4 STORY �b NEW SMH2, RIM EL. 9.35 w o N �, J 'Y / O� ,',F'";';`r : } OFFICE BLDG. INV. EL. 3.55S, 6.00N,E,W I �, 0 .� 'C / O r (SEE DETAIL ON DWG. C-6). I • 10 ' s A- F.F.E.11.80 FOR CONT. OF CONDENSATE WCLI o' o\� K a, i U.P. ROOF AND DECK DRAIN LINES,- \� SEE PLUMBING DWGS, TYP. b o \O SAN. LT - `7 / b. -_•„ .. , ,✓" b o� CB, G ATE 10.s \hh k D/FF. IN GRADE SHALL INV EL 8.60 I I II o NOT EXCEED 30" TVP. � \ �07'°..,.-r•,...s"^•......f', - I SMH, �IM 10.7 INV EL 4.82#7 1 6 __. 15' p 7.62 6.42SE 5k 1 F- I ASPHALT 50 W. OF 3 x 15D EXFIL. .�_ `u- ' c� �v TRENCH W/18"0 PERF. HDPE ®� c�,a �o k 5o I J 0AVEMENT �' ;�� o, tel? 0 Ox SLOPE (INV. EL. J.0) R R R o SLOPE CONC. ,SDWK/CURB 8. 0 b ^� ( < ICN CM, GRT o.2 TO MATCH EXIST ELEVS d.35 8.20 RAMP DN. F d.30 _ "!! DA' F.P.L. INV EL . ON PROPERTY LIN �. EASEMENT Ilk (•, `ti 10.2 0.80Ele, \ �. 1 MATCH EXIST. ASPHALT DN. 7.75 R/W LINE 7.56 7.Ci4 6.04 8.12 �, 9.0 - R/W LINE y`L obo 1 I R/W LINE ELEVS ON PROPERTY LINE • P ;... bI`6 d�O I� 8.79 9.65 �Ok GRATE 10.40 i CB, GRATE 9.80 10� iv- ( �� INV EL 6.71 -15" VCP SAN -- rte- - --- '�� 15" VCR SAN-- - T -'b� --�' + ' � r-- I 1^ / - "� SAN MH RIM 10.7��15" VCR SAN - MATCH EXISTING ;;;.50.5 � SAN MH, RIM 7.38 1 7 4 � a � N a I-- o -- -- �,,�� � - _,-- INv FI -3 82W -----_PJCM_T FJ'�,-TYP ____ b .� N � ..�. INV EL 400N, .S�TRET �0 X g0 S� I 60 k -3.77E, - __. - 3.45W ----- 3.78S 5 '1 N __--_-._. 3,50E b' b' _ I u� �� . p b`L ._ b5 ¢ OF 50' R/W �0? 0� ��� 100 1� L b' I (� -24" S� -- -- - SMH, RIM 11.10 SMH, 9.72 (_5 o INV EL 5.85N, o. ��--�,•�-'" �, -3t�RrEai- ��_ ' RIM I ! o "' INV L 512N, b�-- 5 h----•�b� . -� �� �„ � �O � � b� I � � � 1 � � �.r ----- ._._. �• `''�?��:',1 �--k-h °'' �.47�, 3.42E � �• ��'� 4" WM - I %F 40 OF 3 N!!�xLl�l6 Q EXFIL. �, . SIGN �,ap . DROR CURB 5 ''' °SIG WM C GRATE 9.36 , .: CB GRATE 10.50.. rt ., R/W LINE" k SIGN b5 / rn / TRENCH W/fry"0 PERF. HDPE - X I % bo e I - b6, o ^. � +,sl EL 4.86 o �INV EL 7.35 o Ox SLOPE (INV. EL. 3.0) o NM 8. 16"0 H P T CONHOPE 0 CORE DRILL EXIST. STORM M.H. k / b 35' OF 5'W. x 15'D' EXFIL. NV�ELI3. 1S, 24"0 PERF. HDPE W/ TRENCH W124 "� PERF. HDPE 3.25W -I: SIGN 24x 1 d HDPE TEE, TVP. CONN. NEW 24"0 HDPE PIPE AT INV. NOTE ,� / / 3'7pE' -, 15 sD -1-.► I y. EL. 3.00 (POLLUTION BAFFLE REQUIRED) NEW WATER k SEWER LINES / h I Cy OX SLOPE (INV. EL. 3.0) o � � SHOWN FOR REFERENCE ONLY. CB1 JUNCTION BOX W INVERTED BAFFLE INV Too 70 s Ce, RATE 6.90 NEW SMH1, RIM EL. 7.35 ho / / 0 m I INV 3.20 INV. EL. 3.00&,W,S, 3.25N 148 OF 5W, x 15V EXFIL. SEE DWG. C-4 W/USF 5105 VALLEY GUTTER INLET FRAME do J h �I g R II (SEE DETAIL ON DWG. C-6). TRENCH W/24 "0 PERF. HDPE 6146 GRATE. GRATE EL. 7.40, INV. EL. 3.00 EW,� � La.l �.� N 3.25S FOR TRENCH, INV. EL. 4.50 E, W FOR w � CONN, t4'-18" O HDPE PIPE TO EXIST. OZ SLOPE (INV EL. 3.0) BLDG. SERVICES (SEE DWG. C-6 FOR DETAILS). o SLAB -COVERED TRENCH. RECONSTRUCT RECONSTRUCT EXIST. SAN. LAT. AS NECESSARY UNDER DRAIN PIPE TO � � TRENCH WALL AS NECESSARY. MAINTAIN MIN. 12„ VERT. SEPAR., TYP. ^b / / (/ o `V b Poe ( u . . Y DRAINA GE• NOTES Y YmF Y 4 V Y 1. ALL DRAINAGE CONSTRUCTION SHALL CONFORM TO THE REQUIREMEN7rw OF THE CITY OF SOUTH MIAMI, THE DEPARTMENT OF ENVIRONMENTAL RESOURCES MANAGEMENT (DERM) AND THE FLORIDA BUILDING CODE, LA TEST E01 770N. V V C, 2. EXISTING UTILITIES ARE PLOTTED FROM THE BEST AVAILABLE sourcES, HOWEVER, NEITHER THE ENGINEER NOR THE OWNER GUARANTEE Tt_ILS.�' ` Y ACCURACY. ANY ADD177ONAL COSTS DUE TO CONFLICTS BETWEEN PROPOSED IMPROVEMENTS AND EXISTING UTILITIES SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. J. CONTRACTOR SHALL EXERCISE ALL CARE AND CAU77ON IN PROTECTING ALL U77LI77ES DURING COMPLETION OF THIS WORK. IN THE EVENT OF DAMAGE, THE CONTRACTOR SHALL IMMEDIATELY N077FY THE APPROPRIATE U77LI TY COMPANY. ANY AND ALL COSTS INCURRED DUE TO DAMAGE SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. ALL ELEVA 77ONS REFER TO N. G. V D. (1929). 5. CONTRACTOR SHALL PROVIDE HIS OWN LINE k GRADE FROM HORIZONTAL AND VER77CAL CONTROL SET BY THE OWNER. CONTRACTOR SHALL ALSO PROVIDE "AS BUILT" GRADES CER70ED BY A REGISTERED LAND SURVEYOR. 6. EXFIL TRA 77ON TRENCHES, CATCH BASINS AND MANHOLES SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY OF SOUTH MIAMI STD. DETAILS. Z DRAINAGE DESIGN IS DONE IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE USING THE BEST INFORMA77ON AVAILABLE. 8. MINIMUM SLOPE OF PIPES FROM ROOF k CONDENSATE DRAINS SHALL BE 14" PER LINEAR FOOT UNLESS OTHERWISE SHOWN, MATERIAL FOR THESE PIPES SHALL BE PVC. 9. DADE COUNTY FLOOD CR17ERIA = 6.50 NGVD. 10. THE SUBJECT PROPERTY APPEARS TO LIE W/7HIN FLOOD ZONE `AE" BASE FLOOD EL.: 10.00 AS DEFINED BY THE UNITED STATES DEPARTMENT OF HOMELAND SECURITY, FEDERAL EMERGENCY MANAGEMENT AGENCY FLOOD INSURANCE RATE MAP NUMBER 120658, PANEL NUMBER 0276J, DATED MARCH 2, 1994. 11. ALL STORM RUNOFF GENERATED BY THE DESIGN STORM EVENT SHALL BE CONTAINED ON SITE: PERIMETER GRADING SHALL NOT PERMIT RUNOFF ONTO ADJACENT PROPERTY. 12. CONTRACTOR SHALL CONDUCT TELEVISED INSPECTION OF ALL STORM DRAIN LINES PRIOR TO AND AFTER CONSTRUCTION. FLOOD LEGEND Commercial, Industrial FoLlo.• 09-4036-0290-090, 100 do 120 ADDRESS: 5900 S. DIXIE HWY, MIAMI, FL 33143 LOTS: 8-10 BLOCK: 2 PLAT BOOK. • 7 PA GE. 11 suBDIt4siON THE SOLOVOFF SUBDIWSION MEETS k BOUND: CROWN OF ROAD ELEV.: 11.40 FT. NGVD. CROWN OF ROAD ELEVA77ON WAS TAKEN FROM A CER77FIED SURVEY PREPARED BY MANUEL FELIPE PLS LIC 1• 4146 SURWWRs NAME DRAINAGE PLANS SHALL BE ATTACHED (If >2 ACRES /MNERHDUS PLANS SHALL RE SIAM/ED WTH FHER DERM/14A1£R CONTROL SEC7701V APPROVAL). DERM/WC - SURFACE WATER MANAGEMENT STORY WAI TER PERMIT (COPY ATTACHED) NIA - SWFMD - ENVIRONMENTAL RESOURCES PERMIT (COPY ATTACHED) WA TOTAL IMPERVIOUS AREA: 0.72 OC. UNDERGROUND PARKING &0 (aRCLE ONE) V ms$ nooDPRoonm PLANS AND CERAf7CA1E SNALL BE ATTACHED BASEMEN T• YES / NO (aRa.E ow) HA VE THIS SI TE OR OTHER POR77ONS OF THIS PROPERTY BEEN GRANTED A CL OMR OR FINAL LOMR ¥.• pmaE avE)YES LOMR� NO LEGEND b 5 Lowest Floor Elev. (including basement/ sunken area. Adjacent grade elevation. (next to the wall of the structure). Catch Basin Elevation. PROPOSED FT. NGVD FT. NGVD FT. NGVD C81 -- 9.00 7.45 O NEW CATCH BASIN NEW EXFIL 7RA 77ON TRENCH LEGEND b 5 EXIS77NG SPOT ELEVA TION 10115 NEW SPOT ELEVA77ON DRAINAGE FLOW ARROW C81 CATCH BASIN NUMBER SMH1 STORM MANHOLE NUMBER O NEW CATCH BASIN NEW EXFIL 7RA 77ON TRENCH HDPE HIGH DENSITY POL YETHYLENE PIPE DIP DUC77LE IRON PIPE R.D. ROOF DRAIN C.D. CONDENSATE DRAIN S.D, STORM DRAIN M CALL 48 HOURS BEFORE YOU DIG IN FLORIDA IT'S THE LAWL. - 1-800-432-4770 SUNSHINE STATE ONE CALL OF FLORIDA, INC. ARCHITECTURE INTERIOR DESIGN PLANNING SEAL: MONEY J. MATEU AR 0008220 JMM CONSULTING ENGINEERS, LLC M.E.P. 126651 S DIXIE HIGHWAY, SUITE 209 MIAMI, FLORIDA 33156 M.A. SUAREZ CONSULTING ENGINEERS STRUCTURAL ENGINEERING 4869 SW 75TH AVENUE MIAMI, FLORIDA 33155 PISTORINO & ALAM CONSULTING ENG. INC. CIVIL ENGINEERING 7171 SW 62ND AVENUE, 4TH FLOOR MIAMI, FLORIDA 33143 FL. REG. No.: EI -004397 MANUEL D. GARCIA FL. P.E. No.: 47639 OXFORD UNIVERSAL 4311 PONCE DE LEON BLVD. CORAL GAILES, FLORIDA 33146 6966 SOUTH,: ­' DIXIE BUILDING •• 5966&5970 •, r ' , ....,. SOUTH DIXIE HIGHWAY`' MIAMI, FLORIDA 33133 MATEU ARCHITECTURE INC. THIS DRAWING IS THE PROPERTY OF MATEU ARCHITECTURE INC. UNLESS OTHERWISE PROVIDED FOR BY CONTRACT. THE CONTENTS OF THIS DRAWING ARE CONFIDENTIAL AND SHALL NOT BE TRANSMITTED TO ANY PARTY EXCEPT AS AUTHORIZED NY THE ARCHITECT/ ENGINEERS OF RECORD. PHASE PERMIT DRAWINGS FILE NAME: PROJECT NO: MA0605 DRAWN BY: CHECKED BY: ISSUE DATE: REVISIONS 3� BLDG. DET. COMMENT. Q FIRE DEPT. COMMENTS 06-11-08 SHEET TITLE GRADING AND DRAINAGE SITE PLAN SHEET:rr�� OF: C -J