Loading...
11-1105-0201900 BOX PROVIDE ADEQUATE SUPPORT FOR BOX IN CEILING OOHI= I I PLUG-IN DETECTOR BASE ,F3— DETECTOR HEAD CEILING I BOX MOUNTING IN SHEET ROCK OR PLASTER TYPE CEILINGS MUST BE INSTALLED WITH CONDUIT) (THIS DIAGRAM IS FOR REPRESENTATIVE PURPOSES ONLY, AND IS NOT AN EXACT SPECIFICATION). LOAD SUMMARY "MAIN 1 OF 1 " (120/24OV, 10) DEMAND LOAD KVA AMPS MAIN 1 OF 1 34.9 145.6 (PANEL 'A') TOTAL DEMMAND 34.9 145.6AMPS FROM INTFC BOARD( - AT FACP - NOTE: I- NOTE:3 CABLE WIRING FOR ADB-FL BASE (STYLE 4 - NOTE: 3 3WHERE O NEXT DEVICE APPLICABLE) NOTE 1: DETECTOR (SLC LOOP) TO BE INSTALLED USING TWISTED FPL WIRE NOTE 2: DO NOT LOOP WIRE UNDER TERMINALS 1 & 2. BREAK WIRE RUN TO PROVIDE SUPERVISION NOTE 3: OBSERVE POLARITY. DO NOT GROUND CONTROL WIRES OR SHIELDS. TIE SHIELDS TOGETHER AT EACH DETECTOR. NOTE 4: SET THE ROTARY DIALS ON THE REAR OF THE DETECTOR HEAD TO CORRESPOND TO THE LAST TWO DIGITS OF THE DEVICE LOOP ADDRESS. REFER TO THE FLOOR PLANS FOR THE DETECTOR DEVICE NOTE 5: RECORD THE LOOP ADDRESS & DEVICE TYPE IN THE SPACES PROVIDED ON SHORT CIRCUIT CALCULATIONS SYSTEM VOLTAGE ■ 120/240.,I0%,911 TOTAL FAULT AT TRANSFORMER HUSHING NO MOTOR CONTRIBUTION = 13p21 A.I.G. W/ MOTOR CONTRIBUTION = I33OM A.I.C. MOTOR CONTRIBUTION OF = WS AMPS UTILITY FAULT CURRENT = O A.I.C. TRANSF. FULL L. AMPS = 206 TRANSFORMER SIZE = 50 KVA IMPEDANCE = 1.60 96 FAULT AT MAIN I OF I PANEL MOP BUS BARS YV NO MOTOR CONTRIBUTION= IOA66 A.I.C. PV MOTOR CONTRIBUTION = II,Dgq A.I.C. WIRE SIZE OR BUS = 3/0 AM& LENGTH OF RUN(s) = 80 FEET NUMBER OF RUN(0) = 2 FAULT AT DEVICE PANEL 'A' SHORT CIRCUIT AT DEVICE BUS BARS NO MOTOR CONTRIBUTION ■ q,146 A.I.C. WITH MOTOR CONTRIBUTION = 10,581 A.I.G. MOTOR CONTRIBUTION IS = WS AMPS WIRE SIZE = 4/0 AWS LENGTH OF FWS) = 10 FEET NUMBER OF RUM(0) = I AREA OF WORK GROUND FLOOR ELECTRICAL SYMBOL LEGEND Cx EILING FAN WITH OR WITHOUT FIXTURE LRA-il FLOOR MOUNTED RECEPT/DATA/TELEPHONE ® LIGHTING CONTROL UNIT SINCLE POLE LIGHT SWITCH - 48" AFF (D FLOOR MOUNTED RECEPTACLE 0 SURFACE MOUNTED FLUORESCENT UGHT FIXTURE 3 THREE WAY SNATCH - 48" AFF U.N.O. ^ (�- 20AMP, 115V, SINGLE RECEPT. O 18" AFF �{, O 8" `{ D DIMMER SWITCH - 48' AFF U.N.O. 4" RECESSED DOWNLIGHTS 20AMP, 115V, DUPLEX RECEPT. O 1AFF 'T 4S or MEQUIPMENT SERVICE SWITCH TRACK LIGHTING 20AMP CIUADPLEX RECEPT. O 18" AFF 3 "' =, FCH 3S} POLES T15AAFFUSE, TY 30AA FRAME + UNDERCOUNTER FLUORESCENT LIGHTING 20AMP, TOPIOUTLET THRU WALL SWITCH DUPLEX RECEPT. 0 18* AFF ® MOTOR STARTER OR CONTACTOR OUTSIDE LIGHT ftFCI 20AMP, 115V, DUPLEX RECEPT. W/ G.F.C.1. h MOTOR OR FAN 20AMP, 115V, DUPLEX RECUT. 8" ABOVE COUNTER ® ACSINGLE STATION SMOKE DETECTOR -W MIN. A AL 120Y AC /BATTERY BAdNP. UDCATE 3'-0• MN. AWAY WET LOCATION CANOPY SURFACE MOUNTED FIXTURE FROM OY DIFFUSER. ��' 1070Ci AND vP (� SPECIAL RECEPTACLE 36" 240 VAC AFF U.N.O. 0 RECESSED SHOWER LIGHT FIXTURE a TELEPHONE JUNCTION BOX O 18" AFF MONOXDEEUUSE TYP� URERS BRK ELECTRONICS DATA OUTLET BOX O 18" AFF CATOM12M 120VAC/bC VITH BATTERY BACK UP. VANITY LIGHT FIXTURE T.V. CABLE OR ANTENNA OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPTER 0 o SUS INDERECT DECORATIVE FWORESCENT FIRE ALARM SPEAKER/STROBE WITH FLASHER FIXTURE W P WEATHER PROOF COMBINATION TELEPHONE/DATA JACK FLOOD LIGHTS e EF EXHAUST FAN Q SPEAKER DUAL INTERCOM/BACKGROUND MUSIC SF SUPPLY FAN V.FL ELECTRIC WATER HEATER I/ KI INTERCOM/AMPLIFIER RECIEVER MASTER UNIT I� C,U, CONDENSING UNIT O REMOTE INTERCOM OJ JUNCTION BOX AHU AIR HANDLING UNIT M DOOR BELL BUTTON r� CONDUIT ® SECURITY ALARM DEVICE U.N.D. UNLESS OTHERWISE NOTED BRANCH CIRCUIT HOMERUN. LONG HASHMARK DOOR BELL RECIEVER A.F.F. ABOVE FINISHED FLOOR W/FLAG DENOTES GROUND WIRE, LONG HASHMARK OR W/O FLAG DENOTES NEUTRAL WIRE, SHORT ® SECURITY ALARM KEY PAD A.G. ABOVE GRADE HASHMARK DENOTES PHASE WIRE. ELECTRICAL PANEL. - SURFACE MOUNTED ID LIGHT CALL SMITCH * NOT ALL SYMBOLS SHOWN HERE MAY APPLY FOR THIS PROJECT -'�-- INSIDE UTILITY RMs— r-- --- 1 I j EXISTING) j 1 RELOCATED I 1 LOAD CENTER I 'A' 1 225A I I MLO I 1 20/24OV,1 I I j1O,OOOAICj I — — — — — — — J ITEMS SHOWN WITH DASHED LINES ARE EXISTING NOT TO BE WORKED ON. ITEMS SHOWN WITH SOLID LINES ARE EXISTING TO BE WORKED ON FOR THIS PROJECT. EXTERIOR OUTSIDE WALL r3 2 (EXISTING) s :MAIN 1 OF 1 i r-- (EASTING) i EBREAKERI 2�0©©A MCB I I( I I I MEQL�112D ;120) - '10 KAIC I G 11 PH _; RISER DIAGRAM KEY NOTES: OEXISTING FEEDER CONDUCTORS AND CONDUIT FROM F.P.L. (3-3/0 IN ANM EXISTING 2' C.) TO REMAIN. O EXISTING 3-3/0 IN AN EXISTING 2"C. OEXISTING 3-3/0 & 1 #8 CU GRND IN AN EXISTING 20C 1 (EXISTING) FPL PAD MOUNTED 1 z-------------------.-------- (EXISTING) #6CU IN 3/4"C. CLAD GROUNDING. TO COLD WATER PIPE n- -------�Q & FOUNDATION STEEL. (EXISTING) _5/8"x1O' COPPER CLAD IF GROUNDING BARS. 6'-0" (MIN) EXISTING ELECTRICAL RISER DIAGRAM-120/240VAC,1+, 3W N.TA LO LOAD ,� 0/24OV. LOAD CENTER ' A * 10K .C. 10K P:.LC.- SERVICE (EXISTING) LOAD CENTER 3148 CKT. NO. BKR. CON N4RE. LOAD A/C-1 W/5.OW HEATER 1,3 30-2 10-3/4" a2II3 1 CU-1 2,4 25-2 10-3/4" -3475 EXISTING A/C-2 W/5.OW HEATER 5,7 30-2 10-3/4" 5203 i EXISTING CU-2 6„8 25-2 10-3/4" 3475 1 EXISTING A/C-3 W/5.OW HEATER 9,11 30-2 10-3/4" 5203 1 EXISTING CU-3 10,12 25-2 10-3/4" 3475 i E WH -1 13,15 25-2 10-3/4" 4500 MASTER BEDROOM US & REQ 14,16,17 20-1(EA.) 12-1/2" 9444 4 s MASTER BATHROOM UGHTS 17 20-1 12-1 /2" - 0 MASTER BATHROOM GFI REQ 18 20-1 12-1 /2" - Q OUTSOE COVE ED AREA UGHTS 19 20-1(EA.) 12-1 /2" 1400 WIM AM GAM GR RECEPT. 20 20-1 12-1 /2" 1080 HALLWAY r!c UTNJTY RM UGHTS 21 20-1 12-1 /2" - Q UTILITY RM OUTLETS 22 20-1 12-1 /2" - Q WASHING MACHINE 23 20-1 12-1 /2" 1500 DRYER 24,26 30-2 10-3/4" 4000 BEDROOM LTS & REC. 25,26,27 20-1(EA.) 12-1/2" - 4 3 BATHROOM LIGHTS 28,30 20-1(EA.) 12-1/2" O BATHROOM GFI REC. 29 20-1 - I Nl16,, STINIO NO Ia W UM 33 20-1 12-1 /2" - Q DINNING, CHANDELIER 34 20-1 12-1 /2" - Q LIVING RM RECEPT. 35 20-1 12-1/2" - Q REFRIGERATOR 11 20-1 12-1/2" 1200 2 U.C. WINE COOLER 13 20-1 12-1/2" 600 d RANGE/OVEN 14,16 40-2 8-3/4" 8000 HOOD EXHAUST 15 20-1 12-1/2" 500 DISHWASHER 17 20-1 12-1/2" 800 MICROWAVE 19 20-1 12-1 /2" 600 MOiEN SMALL APPLIANCES 21,22 20-1(EA.) 12-1/2" 3000QQ SPACE 39,41 - - - TOTAL CONNECTED LOAD (KVA) 52.3 TOTAL LESS A/C (52.3-15.6=36.7) 36.7 1st 10KVA 0 100% 10 REMAINDER 0 35% 26.7x35%--9.34) 9.34 A/C LOAD 4 100% (AC-1 + AC-2 +AC-3 =15.6) 15.6 NET DEMAND 34.9 DEMAND AMPS Q 240V 14 145.6 SERVICE BREAKER 200 FEEDER I REFER TD ELECTRICAL RISER DIAGRAM THIS SHEET FOR SIZES PANEL SCHEDULE NOTES REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND CHARACTERISTICS OF HVAC EQUIPMENT. PROVIDE HVAC RATED CIRCUIT BREAKER. HEATING & COOLING ARE NON -CONCURRENT LOADS. HIGHEST VALUE USED FOR KVA CALCULATIONS AS PER N.E.C. ARTICLE 220.82 (C)(2), 2005 EDITION. �2 ELECTRICAL CONTRACTOR SHALL VERIFY ALL KITCHEN EQUIPT. REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH -IN. �3 ALL SMALL APPLIANCE RECEPTACLES IN KITCHEN SHALL BE GFCI PROTECTED IN ACCORDANCE WITH NEC 210-8. (4 THIS IS PART OF GENERAL LIGHTING LOAD AS SET FORTH IN NEC 220-3(b). �5 PROVIDE ARC -FAULT CIRCUIT INTERRUPTER PROTECTION AS PER NEC 2008 ART 210.12(B) O6 GFCI PROTECTED CIRCUIT BREAKER O7 LIGHTING ON PHOTOCELL U z C-4" o q 5V v �w LLI U cQi a a y s}qH 2 H z w 0 w Q z z O C0 w w Fine Line Engineering Inc. Electrical,1, Plumbing% Fire Protect i o?tst ti Administr¢tioA 5975 W. Sun& vd, ui e*�ib Stynrise, FI. 33313 Voice: '95g:5g4- 6tf'Ikuc 95`4.S�A-3393 r7°ygftWir4r..W° aCA NO J�5 3 0 . «° RPk FREUO0 P.E ' H neG;*0 w M . NO. 32578 sYA ortm w W A. E 0___ . F.r k v/ M M LLJ "' U J Z Q W � 0 = U) 0 Uj (0� W � W J 3: 17 c6 00 Ito M 0 T 0 12 2 ZO NSA �y NF to O W H O a} V yFS. ti Z0 a- Q Z W ^ F ZD 2 m V W 129 aW ODE= Q6013wwww c�i d'ji LU W Z Q z r m ai °d zMR 0 o w 2i 1.= �z� � r, LL p Q W m zt7Q �w Q s CO LL 0S2CLU)O E2.0