11-1105-016J
NEW AZC EQUIPMENT SCHEDULE
UNIT NUMBER
AC-1
I
AREA SERVED
SEE DWG
TOTAL SUPPLY AIR CFM
800
a
OUTSIDE AIR CFM
-
U`
EXTERNAL STATIC PRESS. H2O
.5
FAN MOTOR HP FLA
.5 4.3
ELEC. CHAR. V N
208-1-60
COOL COIL CAP. BTU HR
26.6
TOTAL SENS. HEAT BTU HR
19.9
6
ENT. AIR TEMP. F DB F WB
80.0 67.0
MODEL NUMBER
-
UNIT MANUFACTURER
CARRIER
MODEL NUMBER
FE5ANB004
WEIGHT LBS.
150
REMARKS: REF. PIPING RS RL
1 1 8--3 8-
UNIT NUMBER
CU-1
LOCATION
SEE PLAN
AMBIENT TEMP. F
95
REFRIGERANT R
R-410
COMPRESSOR FLA LRA
10.3-52.0
COMP./COND. FAN FLA HP
1 5-1.1
z
ELEC. CHAR. V N
208 1 60
Un
Z
MANUFACTURER
CARRIER
z
MODEL NUMBER
24ANA124AO03
v
WEIGHT LBS.
330
REMARKS SEER NOTES
21.0
MCA
18.1
MOCP
35
UNIT MTD. ELEC. HEAT CAP.
5.0
z
STEPS OF ELEC. HEAT NO.
1
ELEC. CHAR. V f-
208 1 60
=
MODEL NUMBER
-
NOTE:
1. CONTRACTOR TO PROVIDE AN AUTOMATIC SHUT OFF SWITCH IN CONDENSATE PAN.
SWITCH TO SHUT OFF CONDENSING UNIT AND AIR HANDLER AT TIME OF ACTIVATION.
VENTILATION FAN SCHEDULE
UNIT DESIGNATION
EF-1
AREA SERVED
BATHROOMS
OPERATING WEIGHT LBS.
15
LOCATION
CEILING
FAN TYPE
CENT.
TOTAL AIR CFM
75
DRIVE TYPE
DIRECT
FAN WHEEL TYPE
F.C.
FAN TIP SPEED RPM MAX
-
FAN SPEED,RPM
1500
TOTAL STATIC PRESSURE,IN. OF H2O
.125
Z
FAN MOTOR HP NON OVERLOAD
.009
if
FAN MOTOR STARTER TYPE
-
STARTER FURNISHED BY
-
ELECTRICAL SERVICE AVAILABLE
120 1 60
DESIGN MANUFACTURER
COOK
MODEL NUMBER
GC-140
SERVICE SWITCH
NO
SMOKE DETECTORS
NO
W
FIRE DAMPER
NO
o
CONSTRUCTION
ALUMINUM
MUL71BLADE BACKDRAFT DAMPER
YES
8
BIRDSCREEN
NO
SOLID STATE SPEED CONTROL
NO
10 MIN. TIME OFF RELAY CONTROL
NO
FACTORY FABRICATED CURB
INU
SONES
12.5
NOTE
I 1
NOTE: 1. INTERLOCK WITH LIGHT SWITCH
2. PROVIDE DEDICATED SWITCH
COOLING LOAD SUMMARY
UNIT NO.
[SO. FT.]
AC-1
FLOOR AREA
[SO. FT.]
779
OUTSIDE DRY BULB
IT]
91
OUTDOOR WET BULB
[F]
78
RELATIVE HUMIDITY
[X]
50
INDOOR DRY BULB
[T]
75
GRAINS OF WATER
[DIFF]
1.73
TOTAL COOLING / O.A.
[BTU/HR]
26.0
TOTAL SENSIBLE GAIN
[BTU/HR]
19.0
TOTAL LATENT GAIN
[BTU/HR]
7.0
TOTAL HEATING / O.A.
[BTU/HR]
10.3
GENERAL SPECIFICATIONS
1. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED AND COMPLETED IN
FIRST CLASS WORKMANLIKE MANNER, ANY MATERIALS INSTALLED, WHICH
SHALL NOT PRESENT AN ORDERLY AND REASONABLY NEAT OR
WORKMANLIKE APPEARANCE, SHALL BE REMOVED AND REPLACED WHEN SO
DIRECTED BY THE ARCHITECT/ENGINEER AT THE CONTRACTOR'S EXPENCE.
i
2. NEW DUCTWORK SHOWN IS SCHEMATIC. PLAN ROUTING OF DUCTWORK AND
COORDINATE LOCATION OF DUCTS AFTER INSPECTION OF EXISTING
CONDITIONS AND BEFORE FABRICATION, SLIGHT VARIATION OF ROUTING
AND/OR CONSTRUCTION SHOULD BE ANTICIPATED AND IS EXPRESSLY
INCLUDED AS PART OF THE WORK WHENEVER REQUIRED, AT NO
ADDITIONAL COST TO OWNER. IGNORANCE ON THE PART OF THE
CONTRACTOR WILL IN NO WAY EXCUSE HIM OR SHE FROM THE
OBLIGATIONS AND RESPONSIBILITIES OF THIS CONTRACT,
3. ANY CONFLICTS OR DISCREPANCIES ON THESE DRAWINGS SHALL BE
CALLED TO THE ATTENTION OF THE ARCHITECT/ENGINEER DURING THE
BIDDING PERIOD FOR RESOLUTION, OTHERWISE, ALL SUCH CONFLICTS OR
DISCREPANCIES SHALL BE RESOLVED AT THE CONTRACTOR'S EXPENSE.
4. ALL CONTROL WIRING SHALL BE PROVIDED BY THE CONTRACTOR.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION WITH
ALL OTHER TRADES FOR CLEARANCES AND USE OF AVAILABLE SPACE.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING
FOR ALL PERMITS, FEES, INSPECTIONS AND TEST,
7. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT
AND SERVICES NECESSARY FOR THE INSTALLATION OF A COMPLETE
MECHANICAL SYSTEM, READY FOR CONTINUOUS AND SATISFACTORY
OPERATION BY THE OWNER,
8. THE ENTIRE INSTALLATION SHALL COMPLY WITH ALL APPLICABLE NATIONAL,
STATE AND LOCAL CODES, INCLUDING ALL LOCAL RULES AND ORDINANCES.
9. PROVIDE MANUAL DAMPERS WHERE SHOWN ON THE DRAWINGS. DAMPERS
SHALL BE MANUFACTURED ACCORDING TO SMACNA 'HVAC DUCT
CONSTRUCTION STANDARDS METAL AND FLEXIBLE' FIRST EDITION AND
SHALL HAVE LOCKING QUADRANT WITH WING NUT,
10, DUCTWORK MATERIAL
SUPPLY AIR DUCTWORK SHALL BE CONSTRUCTED OF
FIVE POUNDS DENSITY 1-1/2- THICK GLASSFIBER
DESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCE
WITH SMACNKS LOW PRESURE DUCT MANUAL. ALL
DUCT JOINTS SHALL BE SEALED AND TAPED.
11. ALL EXHAUST DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEET
METAL, INSTALLED IN ACCORDANCE WITH SMACNA 'HVAC DUCT
CONSTRUCTION STANDARDS METAL AND FLEXIBLE, FIRST EDITION.
12. FLEXIBLE DUCTS SHALL BE UL LISTED CLASS 1 AIR DUCT, THERMAFLEX
TYPE M-KE OR EQUAL, DUCTS SHALL BE INSTALLED IN ACCORDANCE
j WITH SMACNA 'HAVC DUCT CONSTRUCTIONSTANDARDS METAL AND
FLEXIBLE' FIRST EDITION.
13. DUCTWORK DIMENSIONS INDICATED, ARE INSIDE CLEAR AIR PASSAGE.
ALL EQUIPMENT AND MATERIAL SHALL BE"'WARRENTIED FOR ONE YEAR
AFTER DATE OF ACCEPTANCE BY THE OWNER,
14. AIR DISTRIBUTION DEVICES SHALL BE OF ALL ALUMINUM CONSTRUCTION
WITH TYPE #25 FINISH. ALL DIFFUSERS,'' REGISTERS AND GRILLS SHALL
HAVE OPPOSED BLADE DAMPERS IN THROAT OR NECK, MANUFACTURER
SHALL BE METALAIR OR PRE -APPROVED EQUAL,
15. THE INSIDE OF ALL VISIBLE DIFFUSERS SHALL BE PAINTED BLACK.
16. A/C/ CONTRACTOR TO INCLUDE 1 YEAR MAINTENANCE OF THE SYSTEM.
A/C SYMBOL LEGEND
m
DOUBLE LINE
SINGLE LINE
20 x 12
DUCT (1ST. DIMENSION, SIDE SHOWN;
q n ry
2ND. DIMENSION, SIDE NOT SHOWN)
ry
ACOUSTICAL LINING
-- -
(DUCT DIMENSIONS FOR NET FREE AREA)
DIRECTION OF FLOW
-"
®
DUCT SECTION
UP OR DOWN (SUPPLY)
DUCT SECTION
UP OR DOWN (EXHAUST OR RETURN)
INCLINE OR PROP
R .-
DIRECTION FLDOWARROW
E0TRANSITIONS � i-
S STANDARD BRANCH FOR SUPPLY & RETURN --/
(NO SPLITER)41
SPLITTER DAMPER
VD
VOLUME DAMPER 1
(MANUAL OPERATION) L
AUTOMATIC DAMPERS 1
MOTOR OPERATED)
SEC 3 MOD. MOD.
AD AP -�, ACCESS DOOR (AD)) AD AP
ACCESS PANEL (AP)
vrAD �■-
FIRE DAMPER
AP IN VERTICAL DUCT / IN HORIZONTAL DUCT
SMOKE DAMPER & RADIANT DAMPER
AD
DYNAMIC
MOTORIZED DAMPER
BACK DRAFT DAMPER F- BDD
CEILING DIFFUSER, SQUARE
E 3 CEILING DIFFUSER, RECTANGULAR
CEILING DIFFUSER, ROUND
0 SMOKE DETECTOR, DUCT MOUNTED A
EXHAUST FAN, CEILING MOUNTED
E-----I RETURN AIR GRILLE, CEILING MOUNTED
( } THERMOSTAT
HUMIDISTAT (H )
00O2 CENSOR (C )
OEF-X CENTRIFUGAL EXHAUST FAN EF-X
ROOF MOUNTED
NOTE : THESE ARE STANDARD SYMBOLS AND MAY NOT ALL APPEAR ON PROJECT DRAWINGS
AIR DISTRIBUTION SCHEDULE
SYM
USE
TYPE
ACCESSORIES
NECK SIZE CFM
MFR &MODEL NO
tOx4 0-100
Q
SUPPLY
GRILLE
O.B.D.
1Ox6 101-200
METAL AIRE
12x8 201-300
H4002-1
16x8 301-450
12x6 0-100
O
RETURN
GRILLE
_
16x6 101-200
METAL AIRE
20x8 201-400
H4002R-1
2802 401-1200
30x12 1201-1400
Oc
RETURN
GRILLE
-
18x18 0-800
METAL HIRE
22x22 801-1200
RH-1
NOTE: CONTRACTOR TO PROVIDE ROUND TO SQUARE NECK TRANSITON.
.�,
w s 'o
µ_
0n
R�
w
z
0
C�
n
ry �nry
®CL
C)
R
w
G7
Fine Line Engineering Inc.
Electrical, Mechanical,' Plumbing
Fire Protect' nru�ihpn Administration
5975 W. S s"%Blvd..Sjnt sunrise, Ft. 33313
Voice: 454 5g� 3 6 !� . 9Sgg 9 4-3343
kiecEin� Ineeis,cem
N O 2, 9;
673 �.
Al
•`. ;p�i�q�p 4, 32578
co
Z
w
O
w
Q
M
UJI
Z�
Q
WC) _�
O 0
E" t W
Q
J W
5-3 � V
Q
w
W
D ~
LO
0
CD
e-
o
o
w
C
r O li
ZU3
o44Qa0
z
LU w m
¢ Q m w
~O
0
OUcoa
CD q w
co o U
i
W M1.0
V/
< i