11-1105-012J STRUCTURAL NOTES: 0PORDINATION: -COORDINATE ALL DIMENSIONS, ELEVATIONS 4 OPENINGS WITH ARCHITECTURAL DRAWINGS. REPORT ANY DISCREPANCIES TO OUR OFFICE. -CONTRACTOR MUST VERIFY THE ACCURACY OF ALL EXISTING CONDITIONS WHICH MAY IMPACT THE AMOUNT AND SEQUENCE OF THE WORK EXISTING CONDITIONS: -EXTREME CARE MUST BE USED DURING ALL NEW EXCAVATION, FOUNDATION AND DEMOLITION WORK SO AS NOT TO UNDERMINE ANY OF THE EXISTING FOUNDATION THAT MUST REMAIN. FOUNDATIONS: -SOIL STATEMENT- VISUAL INSPECTION OF THE SITE SHOWS A SOIL OF LIMESTONE WITH SANDY POCKETS AND WITH A LAYER OF TOPSOIL. THIS LIMESTONE HAS A SAFE BEARING CAPACITY IN EXCESS OF 2000 p5F. AT THE TIME OF CONSTRUCTION A LICENSED ARCHITECT OR POFESSIONAL ENGINEER SHALL SUBMIT TO THE BUILDING OFFICIAL A LETTER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATIONS CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED. BUILDING PAD PREPARATION_ -TREES, BRUSH, ROOTS, TOPSOIL, RUBBLE, ORGANICALLY CONTAMINATED OR OTHERWISE OBJECTIONABLE MATERIALS ENCOUNTERED ARE TO BE REMOVED FROM STRUCTURAL AREAS OF THE SITE. FOR A MINIMUM DISTANCE OF FIVE FEET OUTSIDE STRUCTURE PERIPHERY. -EXISTING GROUND BENEATH STRUCTURE FOUNDATION SHALL PROOF ROLLED. AREAS EXHIBITING INSTABILITY ARE TO BE UNDERCUT AND BACKFIELD AND COMPACTED. -THE PROPOSED ENGINEERED FILL MATERIALS ARE TO BE PLACED IN LIFTS NOT EXCEEDING EIGHT (0) INCHES, LOOSE MEASURED THICKNESS IN UNCONFINED LIFTS OR 6" IN CONFINED AREAS. EACH LIFT IS TO BE COMPACTED AS FOLLOWS: I.- SLAB ON GRADE: MINIMUM OF 55% MAXIMUM DENSITY BY ASTM D1551. 2: FOOTING BEARING: MINIMUM OF 95% MAXIMUM DENSITY BY ASTM D1551. TEWITE PROTECTION: AS PER F.B.G. 105.11 BUILDING COMPONENTS AND BUILDING SURROUNDINGS ARE REQUIRED TO BE -PROTECTED FROM TERMITE DAMAGE IN ACCORDANCE WITH 1503.4.4, 1804;6.2.1, IS16.1B, 2304 OR 26033, OR REQUIRED TO HAVE CHEMICAL SOIL TREATMENT IN ACCORDANCE WITH 1816 SHALL NOT BE COVERED OR CONCEALED UNTIL THE RELEASE FROM THE BUILDING OFFICIAL HAS BEEN RECEIVED. ALL BUILDINGS SHALL HAVE PRE -CONSTRUCTION TREATMENT PROTECTION AGAINST - SUBTERRANEAN TERMITES AS PER F.B.G. 1816.1.1. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES". coRET -COMPRESSIVE STRENGTH AT 28 DAYS: SLAB ON FILL: 3000 PSI ALL OTHER POURED -IN -PLACE CONCRETE: 3000 PSI GROUT: 3000 PSI -TEST: A MIN. OF 5 CONCRETE SPECIMENS SHALL BE TAKEN FROM EACH 5O CU. YD. OR PORTION THEREOF SPECIMENS SHALL BE TESTED ACCORDING TO A.S.TM. C-3S, ONE AT 3, ONE AT 1, AND 3 AT 28 DAYS. -COVER: CONCRETE DEPOSITED AGAINST THE GROUND: 3" FORMED CONCRETE IN CONTACT WITH THE GROUND: —2" BEAMS AND COLUMNS: 1-1/2" INTERIOR SLABS: 3/4" EXTERIOR SLABS• SLAB ON FILL: (PLACED ACCORDING TO ACI 302) -JOINTS: ISOLATION JOINTS MUST BE USED AT JUNCTIONS WITH WALLS AND COLUMNS, USE 1/2" THICK PREMOLDED JOINTS FULL DEPTH OF SLAB. CONTROL JOINTS PLACED AT CENTERLINE OF COLUMN LINES PROVIDE INTERMEDIATE JOINTS IF COLUMN SPACING IS GREATER THAN 30'. IN SIDEWALKS PROVIDE TOOLED JOINTS SPACED AT INTERVALS EQUAL TO THE WIDTH OF THE SLAB. 4" 4 5" SLABS I" DEEP TOOLED JOINTS MUST BE SAWED BEFORE 24 HOURS AFTER CONCRETING. CONSTRUCTION JOINTS MUST BE PLACED IN THE SLAB WHERE BUILDING EXPANSION JOINTS ARE SHOWN AND WHERE CONTROL JOINTS ARE SHOWN. j WHEN CONCRETING AND OPERATING ARE CONCLUDED FOR THE DAY, CONSTRUCTION JOINTS SHALL j BE FORMED WITH BURKE KEYED KOLD METAL JOINT FORM OR APPROVED EQUAL. -VAPOR BARRIERS: a WATERPROOF MEMBRANES (OVERLAPPED b" AT JOINTS) WITH A PEIRMEANCE OF LESS THAN 03% E- PERMS IN ACCORDANCE WITH A.S.TM. E-W SHALL BE PROVIDED UNDER INTERIOR SLAB. WHERE NO VAPOR BARRIER IS USED THE SUBGRADE MUST BE DAMPENED WITH WATER IN ADVANCE OF . y CONCRETING. NO FREE WATER STANDING ON THE SUBGRADE NOR ANY MUDDY OR SOFT SPOT IS PERMITTED. -ANY STRUCTURAL MEMBER PENETRATING SLAB ON FILL IS TO BE 1/2" PRE -MOLDED JOINT FILLER COMPLYING WITH A.S.TM. D-1152, TYPE I. -FINISHING: NO PREMATURE FINISHING SHALL BE ALLOWED. IMMEDIATELY FOLLOWING FLOATING TROWELING bWITH STEEL TROWELS SHOULD BE COMMENCED IF REQUIRED GROOMING SHALL BE AFTER THE ,. STEEL TROWELING OPERATION. a -SLAB FINISHES: (UNLESS OTHERWISE NOTED BY THE ARCHITECT) p" BUILDING: STEEL TROWELED OUTSIDE SLAB: GROOMED co FREIrFORGING STEEL: x -REINFORCING BARS CONFORMING TO A.S.TM. A-615 GRADE 60, INCLUDING COLUMN AND BEAM TIES. o-WELDED FIRE FABRIC CONFORMING TO A.S.TM. A-155 AND SUPPORTED ON SLAB BOLSTERS r, SPACED AT Y-O" O/C. -' -FABRICATION AND DETAILING ACCORDING TO A.C.I -315. -ALL ACCESSORIES TO HAVE UPTURNED LEGS AND PLASTIC DIPPED AFTER FABRICATION. cue 5TgLc_m9& STEEL - -ALL �._ m -ALL STRUCTURAL STEEL PLATES SHALL CONFORM TO A.S.TM. A-36. -ALL STRUCTURAL STEEL WELDING SHALL BE PERFORMED WITH A.W.S. D.I.I. a -ALL ANCHOR BOLTS SHALL CONFORM TO A.S.T.M. A-301. w -ALL BOLTS SHALL CONFORM TO A.S.TM. A-325. �. -ALL SQUARE/RECTANGULAR COLUMNS SHALL CONFORM TO A.S.TM. A-500, GRADE C (Fy = 4(o KSI). -PROVIDE ONE SHOP COAT OF RUST INHIBITING PAINT MIN. 3 ML. DRY FILM THICKNESS. -FABRICATIONS AND ERECTIONS SHALL BE DONE IN ACCORDANCE WITH THE LATEST A.I.S.C. SPECIFICATIONS. a, WELDM: �pl -ALL WELDING SHALL BE PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH BY j A.W.S. BY CERTIFIED WELDERS. ci -CONTRACTORS TO USE E-10 SERIES LOW HYDROGEN ELECTRODES. IISE& -ALL JOISTS AND RAFTERS SHALL HAVE A MIN. STRESS GRADE OF Fb = 1200 PSI, E=1,100pJ00 PSI (SOUTHERN YELLOW PINE). -TRUSS MANUFACTURER TO SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR APPROVAL INDICATING ALL REACTIONS TO THE SUPPORTING STRUCTURE. MASONRY WALLS: -BEARING MASONRY SHOWN THUS �� IN PLAN SHALL BE ERECTED PRIOR TO THE ^� STRUCTURE ABOVE HAS BEEN POURED. -NON-BEARING MASONRY SHOWN THUS IN PLAN SHALL BE ERECTED AFTER THE STRUCTURE ABOVE HAS BEEN POURED. N -MORTAR CONFORMING TO A.S.TM. C-210 TYPE 11" (2500 PSI). 0 -PROVIDE 9 GAGE LADDER TYPE HORIZONTAL REINFORCEMENT AT 16" O/C (FOR REINFORCED cn WALLS). -PROVIDE S GAGE TRUSS TYPE HORIZONTAL REINFORCEMENT AT 16" O/C (FOR NON -REINFORCED WALLS) z -WHENEVER ANCHOR BOLTS ARE TO BE SET IN MASONRY. TWO CELLS AT THE SETTING LOCATION «- SHALL BE FILLED WITH CONCRETE. -GROUT FOR MASONRY UNITS SHALL CONFORM TO ASTM C416 -PRISM STRENGTH OF MASONRY UNITS SHALL BE A MINIMUM OF f'm = 1500 PSI. (f'c = 1500 PSI) w z -MAXIMUM POUR LIFTS FOR MASONRY UNITS AND GROUT POUR HEIGHTS SHALL BE 4'-0". z -GROUT FOR FILLED CELLS SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 3000 PSI WITH A SLUMP OF 9" TO 11". w -CONCRETE BLOCKS SHALL BE C-130 TYPE, PLACED IN A RUNNING BOND PATTERN. z a co 0 a° DESIGN CRITERIA: (SUPERIMPOSED LOADS) -LIVE LOAD: 30 PSF (ROOF) -WIND LOAD: PER A.5.C.E.1-05 CATEGORY: ]I EXPOSURE - "C" IMPORTANCE: 1.00 WIND VELOCITY: 146 MPH MEAN ROOF HEIGHT: 0-011 GGPI: 0.15 (ENCLOSED) 055 (PARTIALY ENCLOSED) OMEIR ARCHITECT, AND CONTRACTOR NOTEd��iTCAN�����• -CHECK FOR SHOP DRAWINGS AND INSPECTIONS OF REINFORCEMENT IN THE FIELD IS REQUIRED IF THIS OFFICE IS TO BE HELD RESPONSIBLE FOR THE STRUCTURAL ADEQUACY OF THE CONSTRUCTED BUILDING. sHmM RE -SING AND TEMPORARY BRACING: -ALL SHORING, RE -SHORING AND TEMPORARY BRACING REQUIRED IN THIS PROJECT IS TO BE DESIGNED BY FLORIDA PROFESSIONAL ENGINEER WHO SPECIALIZES IN FORM WORK/TEMPORARY BRACING DESIGN. AND WHO HAS BEEN HIRED BY THE GENERAL CONTRACTOR THE GENERAL CONTRACTOR IS THE ULTIMATE RESPONSIBLE PARTY FOR SHORING, RE -SHORING, AND TEMPORARY BRACING REQUIRED ON THIS PROJECT AND MUST SATISFY HIMSELF WITH THE ADEQUACY OF THE INSTALLATION OF THESE ITEMS AT ALL TIMES. sA m OSHA AND LABOR LAWS. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, TEMPORARY BRACING, ETC. THAT MAY BE NECCESARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER COMPLETION OF THE PROJECT. -THE STRUCTURAL ENGINEER OF RECORD DOES NOT POSSES, NOR PRESUMES TO POSSES ANY KNOWLEDGE OR EXPERTISE IN MATTERS TO JOB SITE EMPLOYEE SAFETY, OSHA OR LABOR LAW REQUIREMENTS FOR A CONSTRUCTION PROJECT. SAFETY AND COMPLIANCE WITH OSHA AND LABOR LAWS ARE THE ABSOLUTE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THOSE CONSULTANTS HE HIRES TO ADDRESS THESE MATTERS. THE STRUCTURAL ENGINEER OF RECORD SPECIALIZES IN STRUCTURAL DESIGN ONLY, AND THE BOARD OF PROFESSIONAL REGULATION FORBIDS HIM FROM ASSUMING RESPONSIBILITY OUTSIDE HIS AREA OF EXPERTISE AwFL ICIABLE CODES - IN MY PROFESSIONAL JUDGEMENT AND THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE FLORIDA BUILDING CODE. -ALTHOUGH THE ENGINEER OF RECORD HAS STRIVED TO MEET ALL APPLICABLE CODES AND LOCAL ORDINANCE REQUIREMENTS, THE CONTRACTOR IS STILL RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND ORDINANCES IN THE EVENT OF CONFLICT OR OVERSIGHT IN THESE DRAWINGS. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER OF ANY CONFLICT OR DISCREPANCY ENCOUNTERED SO THAT APPROPRIATE REMEDIES MAY BE UNDERTAKEN. -THE APPLICABLE CODES ARE- FLORIDA BUILDING CODE, LATEST EDITION.12001 W/2009 SUPPLEMENTS) A.C.1. 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. A.C.I. 530 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. (2008 EDITION) NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. (2005 EDITION) A.I.S.C. MANUAL, 13th EDITION. SHOP DRAWING SUBh1ITTALB: -SUBMIT FIVE PRINTS OF ALL SHOP DRAWINGS LISTED BELOW. IF SIGNED AND SEALED SHOP DRAWINGS ARE REQUIRED, THEN SUBMIT TWO ADDITIONAL SIGNED AND SEALED PRINTS FOR APPROVAL. -SHOP DRAWINGS: REINFORCING STEEL. STRUCTURAL STEEL. CONCRETE MIX DESIGN. STANDARD HOOK - ROOF OR COLUMN TERMINATION PT. DOUBLE TIES (3" G.G.) III —3 TIES 103" _ �; OF COLUMN AND FOOTING (U.ON. IN PLAN) JOINT J-2 CONCRETE SLAB, SEE PLAN FOR THICKNESS EL. SEE PLAN AND REINFORCING VAPOR BARRIER qL SEE SPECS. J WELL COMPACTED Q FILL p EL. SEE PLAN F- U DOWELS SAME SIZE 4 : NUMBER AS VERT. REINF. (SET TO CLEAR BARS L STANDARD ABOVE) GLR. HOOK FOR FOOTING SIZE AND REINFORCING, SEE SCHEDULE 1.- USE 03 TIES FOR 010 VERTICAL REINFORCING OR SMALLER 2.- TIE SPACING SHALL BE: A - LEAST DIMENSION OF COLUMN B - 16 TIMES MAIN BAR DIAMETER C - 03 AT 18" OR 114 AT 24" WHICHEVER IS SMALLER TYPICAL CONCRETE COLUMN SPLICE DETAIL N.T.S. FOOTING SCHEDULE MARK 51ZE W x L x D REINFORCEMENT REMARKS LONG. TRANS. WF-16 16" x CONT. x 12" 205 1 "5e24" O.G. BOTTOM CF-10 1'-O" x 7'-O" x 12" 8 45 8 05 TOP 4 BOTTOM CF-80 8'-0" x V -0" x 24" 1 9 05 9 05 TOP 4 BOTTOM NOTE : I. CONTRACTOR TO PROVIDE 05 CORNER BARS LAPPED MIN. 30" EACH WAY, FOR EACH BAR IN FOOTING. COLUMN SCHEDULE MARK SIZE REINFORCEMENT REMARKS VERTICALS OR BASE TIES OR CAP It TC-I 8" x 12" 405 03 a 12", IO 611x11" 605 #3612" O2 8" x 20" 6 +'S 03 A 12 O3 8" x 12'x 8' 8 +'5 03 m 1211 SEE DETAIL 4(J TS 4 x 4" x 1/4" S x 8'x 5/5 SEE DETAIL fy=46 ksl NOTE : O DENOTES COLUMN START DENOTES COLUMN END SI' 11 a .. "3 HAIRPIN — 4e. • Y d 6 GOLM DET. COL.® PET. A <• e 44 4�� Sri GOL.O DET. BEAM SCHEDULE SIZE (INCHES) Bottom FEW. TOP REINFORCING STIRRUPS REMARKS MARK TOP ELEV. D "Al' BARS` "B" BARS "C" BARS 'IT" BARS "Ell BARS SIZE No. t SPACING EACH END 8" 12" 2 S 2 S # 3 4 612", BAL 640" TB-t 10'-0" 2 "5 2 "5 «3 g4° ()TAPERED BEAM EXTEND BARS FROM TIE BEAM RB-2 1 8'40" $" 12" 2 05 J 2 05 "3 4 1012", BAL 948" GREATER OF 0.5 LI OR 03 L2 1711 BAR 30 BAR 0.3 L DIA. ZJ n � 1 < LASS "A" LAP SPLICE I B BARS LENGTH L/3 T BARS RUN CONTINUOUS OR "T" BARS LAP AS REQ'D. AT MID SPAN. 03 L 2'-2" 0.3 L 11E 11 BARS (Ti'PJ �z 0 H J STD. NOOKS ' m¢ ,s BAR ��C�� BARS"C" BARS "A" . BARS � _ E 2 2111 W w "All BARS 11A11 BARS MID BARS � LI L2 L3 L4 EMBED 12 BAR DIAM. STIRRUPS �. NOTE I LIS .THE LONGER OF ADJACENT SPAN. (0. TOP AND BOTTOM REINFORCEMENT SHALL BE CONTINUOUS FOR ALL TIE BEAMS. " � 2. 8 WIDE BEAMS TAKE A MAXIMUM OF 2 BARS PER LATER. 1. AS PER ACI 315-02, SECTION -1.132.2 IN EXTERIOR PERIMETER BEAMS PROVIDE �J ADDITIONAL BOTTOM REINFORCEMENT OVER THE SUPPORTS EQUAL TO AT LEAST 25% OF 3. STIRRUPS TO BE CLOSED TYPE WITH 135' HOOK. THE LARGER TOTAL BOTTOM REINFORCEMENT AREA CALLED OUT FOR THE MID -SPAN OF 4. MID BARS TO BE *5 �12" EF. WHENEVER BEAM DEPTH ADJACENT BEAMS, AND IN ADDITION, AT LEAST 20% OF THE TOP REINFORCEMENT, BUT NO IS LARGER THAN 2'-0". LESS THAN TWO BARS, SHALL BE CONTINUOUS OVER ALL SUPPORTS. THIS ADDITIONAL 2 #5 CORNER BARS LAPPED REINFORCEMENT 15 TO BE SPLICED WITH A TENSION "CLASS A" SPLICE BEGINNING AT THE Z 5, CONTRACTOR TO PROVIDE FACE OF THE SUPPORT. MIN, 30" EACH WAY. "C" BARS FOR 12" SOU jTH M►� OR WIDER BEAMS. CI�L TYPICAL g ,�1� g R PL/��eGINC D ( p�NO IAA TOP �BARS N.T.S. uQ,i Xq "C" BARS (FOR 8" BMS.) ,TRt1CT Rq1" 'EGTIQN "MID" BARS (SEE NOTE 4) W cv at)VEC) 5Y "MID" BARS (SEE NOTE 4) BOTTOM BARS NOTE : QUANTITY OF "MID" BARS VARIES W/ BEAMS DEPTH. SEE BEAMS SEE NOTE-4 ON BAR PLACING DIAGRAM TYPICAL BAR PLACEMENT DETAIL' N.T.S. I o o H Q v) c) O zOg r 0 U Q o Q >- a Z Q F- m W �mtilZY I-�� W O ��OQ9 U = UDac)0U _j