11-1105-001CORM 1100A-08
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs Residential Performance Method A
Project Name: Halluk residence
.......- .. _
Builder Name:
Street: 6875 sw 69 terrace
Permit Office:
City, State, Zip: Miami, FI , 33143-
Permit Number.
Owner. Mr. Halluk
Jurisdiction:
Design Location: FL, Miami
1. New construction or existing Addition
9. Wall Types (1210.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 1210`00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. WA
R= ! ft2
4. Number of Bedrooms(Bedrms In Addition) 3(1)
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (779.0 sqft.)
Insulation Area
6. Conditioned floor area (ft2) 779
a. Under Attic (Vented)
R=30.0 779.00 ft2
b. WA
R= ft2
7. Windows(128.8 sqft.) Description Area
c. N/A
R= ft2
a. U-Factor. Sgl, U=0.55 128.82 ft2
SHGC: SHGC=0.60
11. Ducts -
b. U-Factor. N/A ft2
a. Sup: Attic Ret: Attic AH: Interior Sup.
R= 6,155.8 ft2
SHGC:
12. Cooling systems - Supplemental for addition
c. U-Factor. N/A ft2
a. Central Unit
Cap: 26.6 kBtu/hr
SHGC:
SEER: 21
d. U-Factor. N/A ft2
13. Heating systems- Supplemental for addition
SHGC:
a. Electric Strip Heat
Cap: 17.1 k'Btu/hr
e. U-Factor. WA ft2
COP: 1
SHGC:
14. Hot water systems - Replacement equipment
8. Floor Types (779.0 sqft.) Insulation Area
a. Electric
Cap: 100 gallons
a. Slab -On -Grade Edge Insulation R=0.0 779.00 ft2
EF: 0.92
b. N/A R= ft2
b. Conservation features
I
c. N/A R= ft2
None
15. Credits
None
Total As -Built Modified Loads: 20.71
Glass/Floor Area: 0.165., , r �; r., Total Baseline Loads: 27.62
Jr
��SS
PASS
"`
SrgT�
I hereby certify that "e plans and sped �♦ tift ered by
Review of the plans and
this calculation are In`b&noliaMe wit thwRon ergy
specifications covered by this
.y e O
Code. q m a f'I`a.r
calculation indicates compliance
with the Florida Energy Code.
y ,'' -z ..,.•����
S=`t .
PREPARED BY:
Before construction is completed
a
DATE:
this building will be inspected for
compliance with Section 553.908
O a
* '
�•; . �•' f ` `a
• ` �`'
" • . •
1 hereby certify that this ildirt8 � design , rs rn' compliance
Florida Statutes.
14 r
COD
with the Florida Energy COcye'.� °°
o°i t too°` k,
WE
r
OWNER/AGENT:_
BUILDING OFFICIAL:
DATE:
DATE: --��
k; % ii 3 t
9/20/2011 4:08 PM
EnergyGauge® USA - FlaRes2008
} :? 'a t ,M