10-344-012w FOOTINGS AND COLUMNS SCHEDULE ALL SLABS SHALL QE A MINIMUM OF 4"TIHICK (3000 PSI AT 28 DAYS MINIMUM) / WITH 6" X 6" - 10/10 W.W.M. ON WELL COMPACTED FILL AND WITH A 6 MIL VAPOR BARRIER BETWEEN SLAM AND FILL... GENERAL STRUCTURAL NOTES 2. SOIL STATEMENT: INSPECTION OF THE SITE INDICATES UNDISTURBED SAND AND LOOSE ROCK WITH A BEARING PRESSURE CAPACITY OF 2,000 PSF. IF ANY OTHER CONDITION ARE ENCOUNTERED ARCHITECT SHALL BE NOTIFIED BEFORE CONTINUING WITH WORK. 2. TIE BEAM: A. ALL CAST -IN -PUCE CONCRETE TIE BEAM IN THIS JOB SHALL BE REINFORCED WITH 4 # 3 TIES AT 12" O.C. AT THE CORNERS AND AT EACH SIDE OF TIE COL. AND AT 48" O.C. ELSEWHERE M. CONTINUITY OF THE REINFORCING SHALL BE PROVIDED AT CORNERS MY BENDING TWO MARS FROM EACH DIRECTIONS AROUND THE CORNER 30 INCHES OR BY ADDING TWO �2� 2 # 5 MARS WHICH EXTEND 30 INCHES EACH END FROM THE CORNERS. 3. CONCRETE: A. ALL CAST -IN -PUCE CONCRETE IN THIS JOB SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH (F'C) AT 28 DAYS OF 4000 P.S.I. B. CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301-89 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS." C. CONCRETE BLOCK WORK SHALL CONFORM TO ALL REQUIREMENTS AND SHALL ME REINFORCED WITH 1 # 9 LADDER TYPE HORIZ, REINFORCEMENT SPACED EVERY OTHER COURSE.Ld D. ALL MASONRY WALLS ARE DESIGNED AS BEARING WALLS, AND SHALL BE N IN PLACE BEFORE SLABS, BEAMS AND COLUMNS ARE POURED. ALL " BEARING BLOCK UNITS SHALL CONFORM TO ASTM C 90, "STANDARD SPECIFICATIONS FOR HOLLOW LOAD BEARING CONCRETE MASONRY UNITS," MORTAR SHALL CONFORM TO ASTM C270, TYPE "M". D-2. GROUT FOR THE CELLS TO BE 3000 PSI MINIMUM "PEA- GRAVEL"CO NC RETE 8" TO 11" SLUMP. D-3. MASONRY WALLS SHALL CURE AT LEAST THREE DAYS TO GAIN STRENGTH BEFORE POURING GROUT. D-4. WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER,THE GROUT SHALL ME STOPPED 1-1/2" BELOW THE UPPERMOST UNIT. D-5. GROUT SHALL BE POURED IN LIFTS NOT TO EXCEED 4' MAXIMUM, E. PROVIDE 1-#9 HORIZONTAL JOINT REINFORCEMENT UDDER TYPE 0 16" O.C. NEW THE CONTRACTOR SHALL ENSURE THE VERTICAL CONTINUITY OF ALL CELLS TO BE FILLED AND SHALL MAINTAIN THOSE CELLS FREE AND CLEAR OF ANY AND ALL DEBRIS TO PROVIDE A CONTINUOUS AND UNOBSTRUCTED WALL CAVITY FOR MAXIMUM HEIGHT OF 12 FEET. ALL VERTICAL REINFORCEMENT SHALL ME HELD IN POSITION AT THE TOP AND BOTTOM OF THE CELL TO ME GROUTED.MINIMUM LENGTH OF LAP SPICES =48 BAR DIAMETERS TYPE "M" MORTAR 2,500 PSI SHALL BE USED TO PLACE ALL UNITS . CONTRACTOR SHALL PROVIDE CLEAN OUT OPENING AT THE ELEV.= SEE PUN BOTTOM OF ALL CELLS TO BE GROUTED AND AT ALL REINFORCING SPLICES LOCATION FOR PROPER VISUAL INSPECTION OF CONTINUOUS CONCRETE FLOW.REINFORCED UNITS MASONRY SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATION FOR THE DESIGN AND CONSTRUCTION OF LOAD BEARING CONCRETE MASONRY OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND THE PROVISIONS OF ACI 531, "BUILDING CODE REQUIREMENTS - FOR CONCRETE MASONRY ". 4. WOOD: WHEN T.R DEPTH EXCED_` WOOD FRAMING MEMBERS OTHER THAN TRUSSES SHALL BE #2 SOUTHERN 36" ADD #4 "1" BARS, PINE WITH A FIBER MENDING STRESS OF 1200 PSI. SIZES SHOWN ARE EA FACE SPAQED AT A NOMINAL. DISTANCE= d 6 - 5. REINFORCING STEEL: A. REINFORCING STEEL SHALL ME DETAILED AND PLACED IN ACCORDANCE WITH ACI 318-89. B. REINFORCING STEEL SHALL BE DEFORMED MARS CONFORMING TO ASTM A 615 GRADE 60 - EXISTING CONC.TIE QEAM DRILL 3/4"X6 1/2" HOLES TO RECEIVE # 5 BARS. FILL HOLES WITH SIKADUR-31 HI -MOD )XY GRPUT OR EQUAL MRF INSTRUCTIONS MIN 6" EMBED )P & BOTTOM) 2#5 IN CONC. FILLED CELL EXISTING CBS OAS. WALL 2#5 VERT. DOWELL EXISTING CONC. FOOTING ON EXIST. WALL DETAIL 8"X12" CONC.TIE REAM 2#5CONT. D2 ADD A#7 NOT. OF T.B C. ALL WELDED 'WIRE FABRIC SHALL CONFORM TO ASTM A 185. STD. H K TYP. D. REINFORCING TO ME HELD SECURELY IN POSITION WITH STANDARD " WINDOW OPEN G H' ACCESSORIES DURING PLACING OF CONCRETE. E. ALL TOP REINFORCING SHALL TERMINATE WITH STANDARD HOOKS AT DISCONTINUOUS EDGES. (BEARING END) (REARING END) F. ALL BOTTOM BARS SHALL BEAR 6" MINIMUM OVER SUPPORTS, DETAI TIRRUP SPACING AT 12" MAX U.O.N. BEAM DROP 6. MINIMUM CONCRETE OVER REINFORCING; MINIMUM CLEAR COVER, IN. A. CONCRETE AGAINST AND PERMANENTLY EXPOSED TO EARTH (UNFORMED FACES).......................3 8"X12" CONC. CAP W/4#5 BARS M. CONCRETE EXPOSED TO EARTH OR WEATHER k #3 TIE 0 36"0/ (FORMED FACES): A. 6 BARS AND LARGER ..........................2 B. 5 MARS AND SMALLER .........................1 1/2 C. CONCRETE NOT EXPOSED TO WEATHER OR IN 0 CONTACT WITH GROUND: 8"X16" CONC. BLOCK A. SUBS AND WALLS.............................3/4 W/ �9 WIRE REINF. TRUSS TYP.) M. BEAMS AND COLUMNS ...........................1 1/2 7. STRUCTURAL STEEL: EVERY OTHER COURSE A. STRUCTURAL STEEL SHALL COMPLY WITH AISC "SPECIFICATIONS FOR DESIGN, FABRICATION AND ERECTION FOR STRUCTURAL STEEL BUILDINGS," LATEST EDITION. B. STRUCTURAL STEEL SHAPES AND PLATES SHALL CONFORM TO ASTM A 36. C. ANCHOR MOLTS SHALL CONFORM TO ASTM A 307. D. BOLTS SHALL CONFORM TO ASTM A 307. E. STRUCTURAL STEEL TUBE COLUMNS SHALL CONFORM TO ASTM A 590, GRADE B, FY= 46 KSL 8, WELDING: A. WELDING SHALL ME DONE WITH E-70 ELECTRODES. 9. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS OF EXISTING STRUCTURES AFFECTING NEW CONSTRUCTION PRIOR TO COMMENCING ANY WORK. ANY VARIATIONS IN ACTUAL FIELD CONDITIONS/DIMENSIONS FROM THOSE SHOWN ON THE CONTRACT DRAWINGS SHALL BE REPORTED TO THE ARCHITECT/ENGINEER FOR DETERMINING THE NEED OF REDESIGN PRIOR TO CONTRACTOR'S SUBMITTAL OF SHOP OR WORKING DRAWINGS FOR REVIEW. 10. SUBMITTALS TO STRUCTURAL ENGINEER: A. REINFORCING STEEL SHOP DRAWINGS. B. TRUSSES SHOP DRAWINGS AND DESIGN DATA. C. STRUCTURAL STEEL SHOP DRAWINGS. 11. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL ORDINANCES, INCLUDING THE SOUTH FLORIDA BUILDING CODE, LATEST EDITION. 12. DIMENSIONS AND CONDITIONS: ALL DIMENSIONS AND CONDITIONS SHALL ME VERIFIED BY THE CONTRACTOR IN THE FIELD PRIOR TO CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE. SCALE IS FOR GUIDELINE PURPOSES ONLY. IF DIMENSIONS ARE UNCLEAR, DO NOT SCALE, REQUEST CLARIFICATION FROM THE ARCHITECT OR ENGINEER. 13. METHODS Ic SAFETY: THE CONTRACTOR SHALL 9E RESPONSIBLE FOR ALL METHODS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION, CONSTRUCTION SITE SAFETY, INCLUDING ALL ADEQUATE TEMPORARY BRACING AND SHORING, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL COORDINATE THE STRUCTURAL WORK WITH THE WORK OF ALL OTHER TRADES 14. PROTECTION OF EXISTING CONSTRUCTION: EXISTING CONSTRUCTION WHICH IS TO REMAIN SHALL NOT BE DAMAGED. CONTRACTOR SHALL LOCATE AND PROTECT CONCEALED PIPES AND CONDUITS PRIOR TO DEMOLITION AND EXCAVATION AND TAKE APPROPRIATE ACTION TO PROTECT THEM AND TO PROVIDE FOR SAFETY. 15, CONSTRUCTION LOADS: IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EMPLOY THE NECESSARY PROFESSIONAL SERVICES TO DETERMINE THE NECESSARY METHODS AND SUPPORTS REGARDING FORMING AND CONSTRUCTION LOADS. 16. CONFLICTS IN DOCUMENTS: IF CONFLICTS OCCUR IN OR BETWEEN ARCHITECTURAL AND ENGINEERING DOCUMENTS, BETWEEN DOCUMENTS AND FIELD CONDITIONS OR OTHERWISE, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE ENGINEER FOR CLARIFICATION AND DIRECTION BEFORE PROCEEDING. THE CONTRACTOR SHALL COORDINATE ALL DIMENSIONS BETWEEN ARCHITECTURAL AND STRUCTURAL DRAWINGS PRIOR TO PROCEEDING WITH THE WORK. 1 #6 IN CONC. FILLED CELL 0 40" O.0 3/4" TEXTURE STUCCO W/ 64 x C6QNC.W'1:4IxON11:4E .F,M(P1lT.EU. F�L N.) I w CL CD EXISTING CONC.TIE BEAM DRILL 3/4"X6 1/2" HOLES TO RECEIVE # 5 BARS. FILL HOLES WITH SIKADUR-31 HI -MOD JXY GRPUT OR EQUAL MRF INSTRUCTIONS MIN 6" EMBED )P k BOTTOM) 1 #5 IN CONC. FILLED CELL EXISTING CBS VIAS. WALL 8"Xi" WINDOW SILL1 #5 W/2#5 1#5 VERT, DOWELL EXISTING CONC. FOOTING NEW[C ON EXIST. WALL DETAIL 5/8" "CDX" PLYWOOD NAILED TO EVERY SUPPORT W/ 8d RING SHANK NAILS 0 6" k W/ 10d NAILS 0 4" ® EDGE ZONE (4'- co EL. 12'-5" - 1 -o 12XIPjj NAILED GETH DOWELS SAME SIZE NO. AS VERT. II EL. SEE PUN GROUND FLOORNP CDla I a I I -I I I- " 'Ill III III�II .;! i mi ry 00 V H 'I I WF 36 SECTION 6 N.T.S 5/8" "CDX" PLYWOOD NAILED TO EVERY SUPPORT W/ 8d RING SHANK NAILS 0 6" W/ 10d NAILS 0 4" 0 EDGE ZONE (4'-8 CRICKET 2X8 WOOD JOIST 0 1 EL. +9 -0' (FIELD VERIFY) 2X4 TO BE CONNECTED TO EA. MEMBER W/14ga GALV. STEEL STRAP W/(4) 16d NAILS INTO MEMBER AND INTO 2X4. TYP. REMOVE EXIST WOOD BEAM ONLY AFTER AJUST, PORT SHORE TO SUPPORT EXISTING ROOF PRIOR TO THE START OF WORK IN THIS AREA THE CONTRACTOR SHOULD COORD. FIRST W/ ARCHITECT/ENGINEER. 2X4 WOOD M (EXIST. WOOD ROOF CONNECTOR Q RB-2 SECTION 4 SCALE 3/4" = 1'-O" 5/8" "CDX" PLYWOOD NAILED TO EVERY SUPPORT W/ Rd RING SHANK NAILS 0 6" & W/ 1Od NAILS 0 4" 0 EDGE ZONE (4'-8 CRICKET 2X8 WOOD JOIST 0 16" EL. +9'-0" I / (FIELD VERIFY) --' 2X4 TO BE CONNECTED TO EA. MEMBER W/14ga GAL W/(4) 16d NAILS INTO MEMBER AND INTO 2X4. TYP. 2X8 WOOD JOIST 0 16" O/C BEYOND Y -- (2) 5/8" DIAM. A- 325 TRHU MOLTS 44U-11S/2"0 LAp-307 ANCHOR --- D 11gTIES NG CLOSED TIES Cl VERT. REINF. -4/2" EXP. JOINT WELDED WIRE FABRIC EL. 12'-5" x-x x-x- x- x- x CONC. COL. BEYOND 20 WOOD MEMBER \EXIST. WOOD ROOF CONNECTOR Q EXIST. TI EXIST. 8" CMU BEARING WALL 5/8" "CDX" PLYWOOD NAILED TO EVERY SUPPORT W/ id RING SHANK NAILS 0 6" k W/ 10d NAILS 0 4" 0 EDGE ZONE (4'-8 NVRT-20 CONNECTED TO EA MEMBER W/(7) 16d NAILS INTO EA MEMBER 2X8 WO D JOIST 0 16" O/C '--6 MIL VISQUEEN 12X 3))4x8 WO BEAM / N NAILED TOGET R((W/10d NAI 0 6" STAGERED Y FOOTING (SEE SCHEDULE) III 3" cL. SECTION 2 -III IIIII I I II I II j- UNDISTURBED SCALE 3/4" LIMEROCK STD. HOOK TYPICAL COLUMN -FOOTING DETAIL N.T.S. "C" BARS (TOP OVER EACH SUPPORT) WHERE BARS DIFFER IN TWO ADJACENT SPANS AT A COMMON SUPPORT, THE LARGER BARS SCHEDULED SHALL BE USED. TOP CONT. (CONTINUOUS TOP BARS) LAP IN MIDDLE 1/3 OF SPANS WHERE REQUIRED. CL1/2" CIRCULAR HOOK. 1/3 LCIREWR 1(�3 Ll 1/3 VEAW OV3 L2 GREATER OF i 7 NOTES: 1. 1" INDICATES THE LARGER OF ADJACENT SPANS. 2. WHERE BOTTOM BARS ARE INDICATED AS CONTINUOUS WITH ADJACENT SPANS, SPLICES, WHERE NEEDED, SHALL BE MADE IN THE END 1/3 OF SPAN WITH 24 DIA. LAP. 3. "1" MARS AS SCHEDULED SHALL BE PLACED EACH SIDE OF REAM. TYPICAL BEAM REINF. PLACING DIAGRAM N. T. S. _ CONNECTOR Q CONC. COL. BEYOND CONC. COL. (SEE SCHEDULE) 5/8" "CDX" PLYWOOD NAILED TO EVERY SUPPORT W/ 8d RING SHANK NAILS 0 6" W/ 10d NAILS 0 4" 0 EDGE ZONE (4'-8"K EL. +9'-0" OIL (FIELD VERIFY) REMOVE EXIST WOOD BEAM ONLY AFTER AJUST. PORT SHORE ' TO SUPPORT EXISTING ROOF PRIOR TO THE START OF WORK IN THIS AREA THE CONTRACTOR SHOULD COORD. FIRST W/ ARCHITECT/ENGINEER. \_EXIST. WOOD ROOF CONNECTOR D RI-1 CONC. COL. BEYOND SECTION 5 PREFAB WOOD TRUSS SEE PLAN FU CONNECTOR 1 12" 31- �- EL. 111 1.5 '-9" 12" STANDARD HOOK 8" TI 2X8 W OD JOIST 0 16" 0.0 /-S" CMU WALL, SECTIONS 3/4" = 1'-0" 2- 3/4" DIA. KWIK BOLT II BY "HILTI" W/ 4 3/4" MIN. IV 12 X12"X3/4" R 1 /4" FILLET / WELD INSIDE 2- 3/4" DIA. KWIK BOLT II BY "HILTI" W/ 4 3/4" MIN. EMBED IN CONC. A 36 A 8"X36"X1/2" FOLDED P INSIDE WIDTH 7" MIN. FRONT VIE 1 IFT CAPACIT CON N ECTO 5 SCALE 3/4', 1'-n" VERTICAL REINF. IN CONC.FILLED CELL (SEE FOUNDATION FOR LOCATION) 2- 3/4" DIA. KWIK BOLT II BY "HILTI" W/ 4 3/4" MIN. EMBED IN CONC. A 36 12"X12"X3/4" It - HOLES FOR 5/8" DIAM. TRHU BOLTS A 36 i"X36"X1/2" FOLDED P INSIDE WIDTH 7" MIN. /`` ISOMETRIC n n \ BOLT A 36 8" 36"X1/2" FOLDED It INSIDE WIDTH 7" MIN, SECTION A (11 T'Y' OF S O U T,4 N1 A N11 BUILDING DEFT STRUCTURAL SECTION )PROVED ,5Y:.. , (D O lqr ?LoLn W L Ln I- 0 m r- N Ln Ezo 0 M U) ' w = Ana O O rlo 00 W U ry W -t cn M Cal O 0 x� cn co C/1 Q `L7 rWn V l 0 n 0 L� RF' " , :�t 4. EHEET r w � fe