11-662REV-035C6 C6 C\j 31326 — — — — — — — — — — — — — — F-7' 61 G RM Existing Garage NEW GAS METER/REGULATOR WATERLINES 3/4-GAS LINE CAPPED FOR IRJTURE GAS GENERATOR (900,000 BTUH) HIGH PRESSURE GAS _7A 1 T Parkway LINE TO CITY GAS 1 T Parkway COMPANY CONNECTION - 1. THE CONTRACTOR SHAH FURNISH ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE SEPTIC TANK SYSTEM IN ACCORDANCE WITH THIS DRAWING, THE APPLICABLE EDITION OF CHAPTER 1OD-6, FLORIDA ADMINISTRATIVE CODE, STANDARDS FOR ON SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS. 2.- THE CONTRACTOR SHALL PAY ALL COST OF PERMIT, INSPECTIONS AND OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. UPON FINAL INSPECTION, A CERTIFICATE FROM THE LOCAL STATE INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER. 3. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. 4. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT, MATERIALS AND LAYOUTS PRIOR TO INSTALLATION. 5. CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB STTE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS, PIPING AND EQUIPMENT. 6. COORDINATE WORK WITH OTHER TRADES. 7. PROVIDE PIPING AS FOLLOWS: DRAIN FIELD: PE PLASTIC PERFORATED FIELD TUBING 4" DIAMETER. SANITARY PIPING & CONNECTIONS: SEE PLUMB. SPECS 9= Z S.W. 67th Street 0 �r� r!lffl I 11NO I z E 213 1 go 1=4 I I WIjWiVV%%7f_ WIN %71VWLa ---------------' NEW 500 SQ. FT. UNOBSTRUCTED AREA 11 --- — -------- 0 MIN. \—EXIST. DRAIN FIELD & UNOBSTRUCTED AREA BEING ABANDONED — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -- — --- — — — — — -- — - Pvjnv 1104 314,6 —DESIGN CRITERIA BUILDING TYPE: LE FAMILY RESIDENCE EXIST. MAIN RESIDENCE AIR CONDITIONED AREA- EXIST. STUDIO AIR CONDITIONED AREA: NEW MAIN RES. ADDITION AIR CONDITIONED AREA. 3260 �SQ. FT 477 SQ. FT 61,3 SO, FT 4 0 SQ. FT ESTIMATED SEWAGE FLOW: I —SEPTIC TANK REQUIRED: 1350 GAL. CAPACITY TABLE 11 HIRS. SEPTIC TANK EXISTING: 1200 GAL. CAPACITY TABLE 11 HIRS. 'DRAIN FIELD AREA REQUIRED: 600 / 0.6 PERCOLATION RATE = 1000 NO.- M-I.- MINTER 250 SQ. FT. SEPTIC TANK NOTE - THERE ARE NO PERTINENT FEATURES ON ADJACENT PROPERTIES AND / OR ACROSS THE STREET THAT MAY BE AFFECTED 13Y THE NEW SEPTIC SYSTEM INSTALLATION. Plumbing Site Plan 1/1611 PROJECT No. 10034.00 Kane Residence FL OWNER John and Ellie Kane F DISTP dBLMON DATE PERMIT SET OW3/11 BLDG. DEPARTMENT COMMENTS O7/20Z1I A CONSTRUCTION SET 08/10/11 ACONSTRUCTION SET 09/21/11 Pablo Corazzini I AR - 91716 Luigi Vitalini I AR - 13513 x vitalinicorazzini A RC H I T E C TS 300 Aragon Avenue, Suite 330 1 Coral Gables, FL 33134 tel: 305.567.0602 1 fax: 305.446.3197 1 www.vcmiami.com FL Registration AA26001654 SHEET NO, p —101