10-662 (2)-042COVER SECURED
WITH SCREWS
THREADED C.O. PLUG
c— FIN. GRADE
4 X 6" DIA. CONCRETE J
PAD FLUSH W/FIN. GRADE SLIP JOINT
ADJUSTABLE COLLAR
THREADED C.O. PLUG
FIN. FLOOR -7
HOT WATER
SUPPLY
3/4-COLD
WATER SUPPLY
L1,255- TANKIFSS
ELECTRIC WATER
HEATER
• • J-BOX
e °
ELECTRIC WATER HEATER DUAL
SCHEMATIC DETAIL N.T.S.
1 1/4'
WALL
PERFORATED
VENT CAP
SLOPE 1/8'/ FT.
I mAl"Nomm
FACE OF WALL
12' MIN.
sti 27 «• 7-
71 • 130
•
24"
AC UNIT
UNION
r s • • • •r
• • '� '. t
Y VJill• J r • i
•C
DRAINFRENCH DETAIL
N.T.S.
1/2" HW & CW
PIPING.
WASTE
FINISHED FLOOR.-� _
HANGER SPACING
PIPING MATERIAL
MAXIMUM
HORIZONTAL
SPACING
MAXIMUM
VERTICAL
SPACING
CAST IRON
5' (A)
15'
COPPER PIPE
12'
10'
COPPER TUBING 1 1/4'i AND LESS
6'
10'
COPPER TUBING 1 1/tO AND OVER
10'
10'
PVC PIPE
4'
10' (B)
STEEL PIPE
12'
16
A - SPACING SHALL BE 10' IF 10' LENGTHS ARE INSTALLED
B - AID STORY GUIDE FOR 2'f AND LARGER
CONC. SLAB �`CONC. INSERT
THREADALL .•r
PIPE
ra-
f INSULATION • - N015j
1'1 M i
GUY GRAY ?,ACE
SAVER W 3.5 DEEP' BOX
FOR MET STUD WALL
/-HW & CW HOSE CONNEC-
ONS W/VACUUM BREAKERS
WATTS DR EQUAL).
ARMTROL MODEL 500
WATER HAMMER ARRES-
WED
GENERAL NOTES:
1. ALL WORK TO BE DONE IN ACCORDANCEWITH THE FLORIDA BUILDING CODE,
STATE AND LOCAL ORDINANCES.
2. BUILDING DRAINAGE SYSTEM TO BE SLOPED AT 1/8' PER FT, MIN. FALL FOR 3- PIPE AND
LARGER 1/4- PER FT. SLOPE FOR 2' PIPE SIZE AND SMALLER DEVIATIONS SHALL BE
APPROVED BY ARCHITECT/ENGINEER,
3. PROVIDE CLEAN OUTS EVERY 75 FT. AND AT BASE OF EVERY WASTESTACK.
ALL CLOSE-OUTS TO BE FLUSH MOUNTED,
4• MATERIALS SHALL BE ALL NEW AND AS FOLLOWS:
A. DRAINAGE WASTE AND VENT PIPING INCLUDING:
PVC DRAINAGE WASTE AND PIPING (DWV) CONFORMING TO
ASTM D-2665, UNDERGROUND NO HUB CAST IRON CISPI STANDARD 301
ABOVE GROUND AND CAST IRON HUB, PLAIN END ASTM A-74 WITH NEO-
PRENE GASKETS UNDERGROUND, INSTALL PLASTIC (PVC) PIPES ONLY WHEN
ITS APPROVED BY LOCAL AUTHORITIES AND NOT TO BE USED IN AIR
RETURN PLENUM.
B. WATER PIPING: COPPER TYPE V ASTAA B-88 ABOVE GROUND AND
COPPER TYPE *K' ASTM 8-88 UNDERGROUND.
C. CONDENSATE DRAIN PIPING: COPPER TYPE 'M' ASTM B-88 INSIDE
THE BUILDING AND PVC SCHEDULE 40 ABOVE ROOF AND UNDERGROUND.
PROVIDE 3/4" ARMAFLEX PIPE INSULATION TO ALL CONDENSATE DRAIN
PIPING.
D. GAS PIPING: BLACK STEEL. SCHEDULE 40 ASTM-53
E. FLOOR CLEAN OUTS: JOSAM SERIES 56020 OR EQUAL.
F. WALL CLEAN OUTS: JOSAM SERIES 58750 WITH ACCESS COVER OR EQUAL
H. VALVES: 125 PSI NIBCO SCOTT. STOCKHAM OR EQUAL
I. HOSE BIBBS: CHICAGO 837 OR EQUAL WITH VACUUM BREAKER.
5, PERFORM THE FOLLOWING TEST-
A. WATER PIPING SHALL BE SUBJECTED TO HYDROSTATIC PRESSURE TEST OF
100 PSIG FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM
BUT NOT LESS THAN ONE HOUR.
B. DRAINAGE SYSTEM: BEFORE INSTALLATION' OF ANY DRAINS, THE END OF THE
SYSTEM SHALL BE CAPPED do ALL LINES' FILLED WITH WATER TO HIGHEST
POINT & ALLOWED TO STAND UNTIL INSPECTION IS MADE AND WATER LEVELS
REMAIN CONSTANT.
C. CORRECT ALL DEFECTS DISCLOSED BY ABOVE TESTS.
D. COMPLETE SYSTEM FIXTURE do EQUIPMENT SHALL BE GIVEN AN IN SERVICE
TEST AFTER COMPLETION OF THE INSTALLATION.
E. STERILIZE ALL WATER LINES WITH A MIXTURE OF (2) POUNDS OF CHLORINATED
LIME TO EACH 1000 gal. OF WATER (50 PPM OF AVAILABLE CHLORINE.) RETAIN
MIXTURE IN PIPES FOR 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER
BEFORE PLACING IN SERVICE
6• PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL PLUMBING
WORK SHALL BE FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD
OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE, AND THAT HE WILL. AT HIS EXPENSE,
REPAIR AND REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING GUARANTEE PERIOD.
7. CONTRACTOR SWILL FIELD VERIFY EXACT' LOCATION OF EXISTING UTILITIES AND POINTS OF
CONNECTION BEFORE COMMENCING ANY WORK.
8. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION
CHARGES REQUIRED.
9. SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT.
MATERIALS AND LAYOUTS PRIOR INSTALLATION.
10. OFFSET PIPING AS REQUIRED TO CLEAR BUILDING STRUCTURE. DUCTWORK, ETC.
AS SHOWN ON DRAWINGS AND AS REQUIRED BY FIELD CONDITIONS.
11. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL A/C CONDENSATE DRAIN
AND TRAP. SEE A/C PLANS FOR LOCATION OF UNITS AND DRAINS.
12. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS
AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT.
13. COORDINATE WORK WITH OTHER TRADES.
14. FURNISH AND INSTALL FIXTURES AS SPECIFIED IN SCHEDULE, THIS DRAWING.
15. EACH BATHROOM GROUP SHALL BE PROVIDE WITH AIR CHAMBERS OR SHOCK
ABSORBER.
16. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE, JUST BEFORE CONNECTING TO FIXTURE
17. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING
SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES.
18. PIPE INSULATION:
A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3/4" FIRE RETARDANT
ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE
DEVELOPED RESPECTIVELY.
B. ALL HOT WATER LINES do 1/2- RECIRCULATING HOT WATER LINES SHALL BE
INSULATED WITH 1" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF
25/50 FLAME SPREAD AND SMOKEDEVELOPED RESPECTIVELY.
PLUMBING LEGEND
SYMBOL
DESCRIPTION
-----------
COLD WATER LME (CW)
—--- —--- -----
HOT WATER RECIRC. (HWR)
CONDENSATE DRAIN LINE
--------
HOT WATER LINE (HW)
SANITARY WASTE LINE (SAN)
- — — — — — —
-
SANITARY VENT LINE M
AIR CHAMBER
-----N------
CHECK VALVE
—�0 FCO
FLOOR CLEAN OUT
—�I CO
WALL CLEAN OUT
-----�4-----
GATE VALVE
'�"• HB
HOSE BIBB
-----�•�-----
VALVE IN BOX
----�} VIV
GATE VALVE IN VERTICAL
oo•---
'P" TRAP
1111
UNION
ABV.
ABOVE
BLW
BELOW
CEIL, CLG.
CEILING
FL
FLOOR
F.U.
FDCTURE UNIT
(UG)
UNDERGROUND
V.TR
VENT THRU ROOF
VB
VACUUM BREAKER
TP
TRAP PRIMER
CONNECTION (NEW TO EXISTING)
� � W
®z
ullP. P�
J te yc-=1
CQ
Cm
sue.iiii, a•a as �•....� s
Qi.9///���� d� a a
C yUjpzw
WC
JIF
W : < F N =
4WA4''
� i3
a4<C'i=
C t; _ zoz ci
QO (� 41-
-/ �+ N 0FX.1a¢
C 33 0 W g iii 2 Sp 2
]G� U Ld W
jz
c' =®F a
.y gp' p z
31 -C �W J d'1
PW% wils
PLUMBING FDCME CONNECTION SCHEDULE
III®����®®
� ell. ' iiti-'' •� ,7i1R'«-'�'
.• I
J REFER TO ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE SPECIFICATIONS
C6�~
er
;P
1 PROJECT No.10034.00
Kane Residence
6695 S`.I 69 Ave
South (.p„ mI, F L �y
OWNER
John and Ellie Kane
0`17 A
J j 6✓e
South M1 ami, FL
OWNERS REVIEW 06/03/11
Pablo Corazzini AR - 91716
Luigi Vdalini AR -13513
Jil*.
vitalinicorazzini
A R,C H I T E C T s
300 Aragon Avenue, Suite 330 1 Coral Gables, FL 33134 °
tel: 305.567.0602 1 fax: 305.446.3197 1
www.vcmiami.com FL Registration AA26001654
0 .Tc SHEET NO.
301
s =