10-662 (2)-038Q
c�
CD
ca
co
co
UD
C/5
�
ak �
NeWProposed --- - dition--- ------------------------- ____________________________________________ _________________ _ _ _ _ _ _ _ _ _ _ _
'xz X X /' X
New E
ting One Story ResidenCE 11
® Addition e
t
I
I
t
t
t
Y t
I I
1 1
I t
I r
' Existing Pool
t
t
t
I
1
8
!
t
1 t
I I
1 t
1 !
1 I
1 t
EXIST. 4' SAN IST. 4SAN. t
(31 FU) ' (50 FU)
I !
t t
APPROVED
I i Mffi6%f-0ADE COUNTY HEALTH DEPARTMENT I
NEW 1000 SO. FT. NEW 500 SQ. FT. �VV
100 -0 MIN. i �.N1200----� - f DRAIN FIE.D UNOBSTRUCTED AREA PERM, ' ID ��9 I
FU i SEPTIC TANK
I J _. _.—®—_—®.___.._.®__..®__®—. ®.._—.®—. _.—®. ®__._.®®__. i /4=���:.•i .vhe i.�'...�..+-4 .0D GAL. (MIN) !
0 -0' MIN. i -� �b t�
J ! NFIELa. s4. FT. (MIN) !
JT111--
4 I 'i( OF SLIGHTLY LIMITED SOIL INSTALL I
UNDER BOTT OF t
--O MIN. i r<n/ERT ELEVATIOl4
1 t BOTTOM OF DRAINFIELD ELEVATED
i PERIMETER OF EXCAVATION AREA SHALL BE_ r
i t AT LEAST 2 FEET WIDER AND LONGER THAN THE Z !
. t PROPOSED ABSORPTION BED OR DRAIN TRENCH-
-a t
Existing Garage - r
EXIST. DRAIN FIELD
New Proposed Garage Addition & UNOBSTRUCTED AREA
BEING ABANDONED I
1
3/4' WATER
LINES r
t
-------------------------- -------------
New Driveway ';'4
W=
1. THE CONTRACTOR SHALL FURNISH All LABOR, MATERIAL AND EQUIPMENT
NECESSARY FOR THE INSTALLATION OF A COMPLETE SEPTIC TANK SYSTEM IN
ACCORDANCE WITH THIS DRAWING, THE APPLICABLE EDITION OF CHAPTER
1OD-6, FLORIDA ADMINISTRATIVE CODE, STANDARDS FOR ON SITE SEWAGE
TREATMENT AND DISPOSAL SYSTEMS,
2. THE CONTRACTOR SHALL PAY ALL COST OF PERMIT, INSPECTIONS AND OTHER
COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. UPON
FINAL INSPECTION, A CERTIFICATE FROM THE LOCAL STATE INSPECTION
AUTHORITY SHALL BE FURNISHED TO THE OWNER.
3. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND MUST BE FURNISHED SO
AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK.
4. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL
OF ALL EQUIPMENT, MATERIALS AND LAYOUTS PRIOR TO INSTALLATION.
5. CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB
SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS, PIPING AND
EQUIPMENT.
6. COORDINATE WORK WITH OTHER TRADES.
7. PROVIDE PIPING AS FOLLOWS:
DRAIN FIELD: PE PLASTIC PERFORATED FIELD TUBING 4' DIAMETER.
SANITARY PIPING do CONNECTIONS: SEE PLUMB. SPECS
S.W. 67th Street
DESIGN CRITERIA
BUILDING TYPE:
SINGLE FAMILY RESIDENCE
EXIST. MAIN RESIDENCE AIR CONDITIONED AREA:
EXIST. STUDIO AIR CONDITIONED AREA:
NEW MAIN RES. ADDITION AIR CONDITIONED AREA:
3260 SQ. FT
477 SQ. FT
613 SO. FT
4350 SQ. FT
ESTIMATED SEWAGE FLOW:
600 GPD
SEPTIC TANK REQUIRED:
1350 GAL, CAPACITY TABLE II HRS.
SEPTIC TANK EXISTING:
1200 GAL. CAPACITY TABLE II HRS.
DRAIN FIELD AREA REQUIRED:
600 0.6 PERCOLATION RATE = 1000 SQ. FT.
UNOBSTRUCTED AREA REQUIRED:
250 SO. FT.
MISEPTIC► CAP. ARE
amON STATE OF FLORM DEPARTMENT OF
HEALTH CHAPTER
TO THE BEST OF MY KNOWLEDGE. AND BEUEFTHERE ARE NO PERTINENT FEATURES ON MIS" PROPERTIES AND / OR
ACROSS THE STREET THAT MAY BE AFFECTED BY THE NEW SEFTIC SYSTEM INSTALLATION.
re�
Plumbing Site Plan 1/16"
C%2 c�
(p W
r! `�� N Z
I I Q ON
• N
J C%Zyy,ZIx
YR � NN�
co NZ K
W C p chi �
C PIL;W®20
ova
■� °�7d' "^max
CD-0 P4 zNWNW
aUt°i=
ca
Oi— rt ZS Q�ZWZ
• �T�^ � YF�5 W
NO VJ 11y�y..=Wi2
4 4 7 = 2 ==J
S� 4 •O NV®J®Z
i. W�<O ppp§pppg
x WumvH
¢aka
oil I-x
PROJECT No.10034.00
Kane Residence
6695 SW 69 Ave
South Mliami, FL
OWNER
John and Ellie Kane
6695 SW 69 Ave
South Miami, FL
OWNER'S REVIEW 06/03/11
Pablo Corazzini I AR - 91716
Luigi Vitalini I AR -13513
N 4 ro�� vitalini r i i
AR C H I T E C T S
300 Aragon Avenue, Suite 330 1 Coral Gables, FL 33134
tel: 305.567.0602 1 fax: 305.446.3197 1
www.vcmiami.com FL Registration AA26001654
E SHEET NO.
4*.� 101
'�S/0lAL T .