10-662 (2)-027(2) 3x6 P.T. CONT. TOP PLATE AROUND CHIMNEY 1/2 " PLYWOOD FILLER AND 1/2" # THRU BOLTS * 12" c/c. (2) 2x6 F.T. CONT. TOP PLATE AROUND CHIMNEY. TOP PLATE ANCHOR BY NUVUE MANUF. MODEL NVTP-6 WITH 8-10dxI112" NAILS TO EACH VERT. STUDS 2x6 VERTICAL STUDS * all- c/c, ALL AROUND OF CHIMNEY. " COX PLYWOOD SHEATHING WITH 10d NAILS • 4" c/c ALL SUPPORT. PROVIDE s/8" CDX PLYWOOD - EACH SIDE OF EACH EXIST. TRUSSES TO BE CUT WITH 16d NAILS * 3" c/c EACH SIDE, EACH EXISTING TRUSS MEMBER. PIGGY BACK TRUSSES * 16" c/c, SEE DETAIL X/S-X FOR ATTACHMENT. 12 Y ti ro 12 EXISTING PREFAB. WOOD -� _ TRUSSES 4 SHEATHING TO . . REMAIN, SAW CUT AS REQUIRED IN ORDER TO ERECT NEW CHIMNEY. EXISTING WOOD RAFTER TO REMAIN, SAW -CUT AS REQUIRED N ORDER TO ERECT NEW CHIMNEY. �,,, �• � - 1 . 1 NUVUE HANGER MODEL NVJW28 WITH - 14-10dx1t/2" NAILS TO HEADER AND 1-10dxll/2" NAILS TO EXIST. RAFTERS. 2xI0 PT LEDGER WITH (2) f/44 x 4" - ` LONG LAG SCREW EACH VERT, STUDS. 2X6 F.T. CONT. BOTT. PLATE WITH (3) I/4 LAG SCREW * 12" c/c AS SHOWN. BOTT. PLATE ANCHOR BY NUVUE MANUF.- MODEL NVTP-6 WITH 8-10dxll/2" NAILS TO EACH VERT. STUDS 2x6 VERTICAL WOOD STUDS * 8" c/c, BEYOND, FROM GROUND FLOOR SLAB. FIREPLACE BY OTHERS, SEE ARCH. DWGS. EXISTING CONC. SLAB TO REMAIN. SECTION SCALE: 3/4" _ 1'-0" TOP OF OL C$41 NEY EL. 4177"-0" 2x6 8" c% STUD WALL BEYOND. PROVIDE (2) 2xro HORIZONTAL BRACE WITH (2) 10d TOENAILS EACH END, EACH 2x6, SAW -CUT EXISTING TRUSS AS REQUIERED PROVIDE its" CDX PLYWOOD EACH SIDE OF EACH EXIST. TRUSSES TO BE CUT WITH trod NAILS * 3" c/c EACH SIDE, EACH EXISTING TRUSS MEMBER EXISTING PREFAB. WOOD TRUSSES 4 SHEATHING TO REMAIN. ADD 2x4 VERT. MEMBER AT END OF PLYWOOD. TA. EXIST. T. BEAM EL. 2 8'-4" -EXISTING WOOD JOIST TO REMAIN. •2x6 F.T. BLOCKING BETWEEN TRUSSES WITH (2) 1/4"0 X 5" LONG LAG SCREW EACH VERTICAL STUDS. DOUBLE NU-VUE HURRICANE CLIP MODEL NVHC-R/L EACH SIDE OF RAFTER WITH (6) 10d x I1/2" NAILS TO WOOD PLATE AND (6) 10d x 1112" NAILS TO LEDGER EACH CLIP. -2Xro P.T. CONT. BOTT. PLATE WITH %"0 SIMPSON WEDGE ALL BOLT LAG SCREL * 1211 c%, 5" EMBEDMENT. .BOTT. PLATE ANCHOR BY NUVUE MAW MODEL NVTP-6 WITH 8-10dx11/2" NAILS' EACH VERT. STUDS EXISTING CONC. TIE BEAM TO REMAIN. EXISTING MASONRY WALL TO REMAIN. T.O. EXIST. _r, SLAB. EL. 0'-0" EXISTING MASONRY WALL TO REMAIN. S. HIGH LIFT GROUTNCs: A) PLACE MASONRY TO A MAXIMUM HEIGHT OF TWELVE (10) FEET. B) CLEAR, UNOBSTRUCTED AND CONTINUOUS VERTICAL CELL SHALL BE A MINIMUM OF 3" INCHES BY 3" INCHES. C) PLACE GROUT IN FOUR (4) FEET LIFTS, 15 TO 60 MINUTES APART TO ALLOW FOR SETTLEMENT AND ABSORPTION OF EXCESS WATER, MAXIMUM FREE FALL SHALL NOT EXCEED EIGHT (8) FEET. D) HOLD TOP OF GROUT V INCHES BELOW LAST COURSE OF BLOCK FOR TWAT LIFT. E) GROUT TO BE CONSOLIDATED IN PLACE BY PUDDLING, ROODING OR MECHANICAL VIBRATION. F) RECONSOLIDATE EACH LIFT BY VIBRATING SEVERAL INCHES INTO PRECEDING LIFT. G) MAXIMUM GROUT POUR IS TWELVE (12) FEET HIGH. 1. TESTING INDICATING ABOVE SHALL BE AT THE DISCRETION OF THE ENGINEER AND MUST BE WAIVED IN WRITING BY ENGINEER FAILURE TO ADEQUATELY, AT THE DISCRETION OF THE ENGINEER MAINTAIN ADEQUATE MATERIAL RECORDS OR PROJECT QUALITY CONTROL PROCEDURES SHALL NULLIFY WRITTEN WAIVER OF TESTING REQUIREMENTS. EXPANSION AND CHEMICAL ANCHORS: I. ALL ANCHORS SHALL BE STAINLESS STEEL. PLATED ANCHORS SHALL BE USED ONLY WHERE SPECIFICALLY PERMITTED ON STRUCTURAL DRAWINGS. 2. EXPANSION ANCHORS SHALL HILTI KUIK BOLT, ZINC PLATED IN 'ACCORDANCE WITH ASTM 8633 OR STAINLESS STEEL OR APPROVED EQUAL. ADHESIVE CHEMICAL ANCHORS SHALL BE HILTI HVA ADHESIVE ANCHOR SYSTEM, ZINC PLATED IN ACCORDANCE WITH ASTM E3633 OR STAINLESS STEEL OR APPROVED EQUAL. 3. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURE SPECIFICATION AND RECOMMENDATIONS. 4. MINIMUM EMBEDMENT SHALL BE CONCRETE THICKNESS MINUS 1-1/2 NCHES, USE LONGEST AVAILABLE ANCHOR THAT MAINTAINS CONCRETE COVER STATED. 5. SPACING AND EDGE DISTANCE SHALL BE AS FOLLOWS: A. AS SPECIFIED BY THE MANUFACTURE TO ATTAIN FULL LOAD CAPACITY IN SHEAR AND TENSION AND AS STATED BELOW. B. MINIMUM ANCHOR SPACING - 12 DIAMETERS. C. MINIMUM ANCHOR EDGE DISTANCE - 10 DIAMETERS. D. IF MINIMUM SPACING AND EDGE DISTANCE CANNOT BE MAINTAINED OR IF STATED/DRAWN AS LESS ON DRAWINGS, PROVIDE 4 03, V-6" LONG FOR ANCHORS UP TO 5/8 NCH AND 2' -6" LONG FOR LARGER ANCHORS, REINFORGEMNt IN SQUARE PATTERN AROUND ANCHOR WITH A HORIZONTAL SPACING OF 2 INCHES. PROVIDE ONE LAYER OF REINFORCEMENT FOR ANCHORS UP TO 5/8 NCH AND 2 LAYERS FOR LARGER ANCHORS. REINFORCEMENT COVER AND VERTICAL SPACING SHALL BE 2 INCHES. PROVIDE EQUIVALENT HAIRPINS SPACED 30 DEGREES APART AND SAME LENGTH AS INDICATED ABOVE FOR ANCHORS PLACED NEAR CONCRETE EDGES. E. SPACING AND EDGE DISTANCE LESS THAN 1/2 MINIMUM IS NOT ALLOWED, EVEN IF REINFORCEMENT IS PROVIDED AS STATED ABOVE. THE CONTRACTOR SHALL NOTIFY THE ENGINEER N WRITING BEFORE PROCEEDING WITH WORK IF THESE CONDITIONS EXIST. 6. WHERE ANCHOR BOLTS ARE SET IN MASONRY WALLS, FILL 3 (ANCHOR BOLT LOCATION AND ADJACENT CELLS) BLOCK CELLS WITH COARSE GROUT TO BEAM, SLAB OR FOUNDATION ABOVE AND BELOW BLOCK CELL OPENING. 1. MINIMUM ANCHOR SIZE IF NOT INDICTED ON DRAWINGS SHALL BE 5/8 INCH DIAMETER WITH MINIMUM LENGTH AS STATED ABOVE. S. ANCHOR BOLT HOLES THROUGH WOOD SHALL BE 1/I6 INCH LARGER THAN BOLT. ST RUCTURAL AND MISCELLANEOUS STEEL: I. ALL STRUCTURAL STEEL FORGED SECTIONS TO BE DOMESTIC ASTM A-588 (FY=50000 PSI) AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" AND THE AISC CODE OF STANDARD PRACTICE. SHEET STEEL SHALL CONFORM TO AMERICAN IRON AND STEEL INSTITUTE SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS. 2. STEEL TUBES TO BE DOMESTIC STEEL CONFORMING TO ASTM A-500, GRADE B, FY=46000 PSI. PIPE COLUMNS TO BE EXTRA STRENGTH, U.ON. FILL PIPE AND TUBE COLUMNS WITH 30M PSI CONCRETE. PROVIDE ONE 1/4 INCH LLEEPHOLE IN COLUMN AT 3 INCHES FROM TOP AND BOTTOM AND ONE AT MIDHEIGHT. ALL STEEL TUBES, STEEL PIPE COLUMNS AND BASE PLATES SHALL HOT DIPPED GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH AISC AND COATING ASTM DESIGNATION G185. 3. BOLTS TO BE HIGH STRENGTH (ASTM-A325) 3/4 INCHES DIAMETER UNLESS OTHERWISE SPECIFIED. PROVIDE MATCHING HS. NUTS AND WASHERS. 4. ALL ANCHORS AND ANCHOR BOLTS EMBEDDED IN CONCRETE SHALL BE HOP DIPPED GALVANIZED AND CONFORMING TO ASTM A-36 SPECIFICATION, UAN.. PROVIDE NUTS AND WASHERS SAME FINISH AS ANCHORS AND/ OR ANCHOR BOLTS. S. ALL WELDING TO BE DONE BY CERTIFIED WELDERS IN ACCORDANCE WITH AMERICAN WELDING SOCIETY STRUCTURAL WELDING CODE -STEEL OIJ, SPECIFICATION FOR WELDING SHEET STEEL IN STRICTURES D13, STRUCTURAL WELDING CODE -REINFORCING STEEL 01.4. ELECTRODES SHALL BE E-10 SERIES, LOW HYDROGEN. AFTER ERECTION AND FIELD OBSERVATION IF REQUIRED, CLEAN WELDS AND TOUCH UP PANT IN ACCORDANCE WITH PARAGRAPH 8 BELOW. 6. SEE THE FOLLOWING NOTES FOR ADDITIONAL APPLICABLE REQUIREMENTSt STEEL JOISTS, STEEL DECKS AND REINFORCING STEEL. I. WHERE REACTION VALUES ARE NOT SHOWN ON THE STRUCTURAL DRAWINGS, THE CONNECTIONS SELECTED SHALL DEVELOP THE MEMBER IN SHEAR AND SHEAR AND MOMENT FOR MC MOMENT CONNECTION. S. STEEL BEARING ON STEEL TO BE WELDED THERETO, EXCEPT AT EXPANSION JOINTS. 9. SHOP COAT ALL STRUCTURAL STEEL WITH RUSTOLEUM "169" RED PRIMER OR APPROVED EQUAL, U.ON., MINIMUM 4 MIL. DRY FILM THICKNESS. 10. FOR MISCELLANEOUS STEEL NOT SHOWN ON THESE DRAWINGS SEE ARCHITECTURAL AND MECHANICAL DRAWINGS. 11. REFER TO ARCHITECTURAL PLANS FOR FIREPROOFING OF STRUCTURAL STEEL MEMBERS. 12. SHOP DRAWINGS ARE REQUIRED. SHOP DRAWINGS SHALL IDENTIFY THE SPECIFIC PROJECT, LIST ALL DESIGN CRITERIA, LIST ALL MATERIAL SPECIFICATIONS AND SHOW ALL STRUCTURAL STEEL CONNECTIONS AND ERECTION REQUIREMENTS.! CONNECTION DETAILS AND DESIGN CALCULATIONS SHALL BE SIGNED AND SEALED BY THE SPECIALTY ENGINEER WHO PREPARED THEM. I. ALL WOOD DESIGN, FABRICATION AND CONSTRUCTION SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, NATIONAL FOREST PRODUCTS ASSOCIATION. 2. ALL STRUCTURAL WOOD TO BE SOUTHERN PINE NO.1 OR DOUGLAS FIR -LARCH NO. 1, OR BETTER WOOD TO BE AIR DRIED, WELL SEASONED AND GRADE MARKED AT MILL. 3. WOOD TO CONFORM TO RILES OF THE MANUFACTURER'S ASSOCIATION UNDER WHOSE RULES THE LUMBER IS PRODUCED. 4. ALL STRUCTURAL WOOD TO BE SURFACED FOUR (4) SIDES (S-4-S) WITH A MINIMUM ALLOWABLE FIBER STRESS IN BENDING OF 1350 P.S.I. AND A MAXIMUM MOISTURE CONTENT OF 1C3%. 5. ALL LUMBER AND PLYWOOD IN CONTACT WITH CONCRETE, MASONRY, STUCCO OR OTHER CEMENTITIOUS MATERIALS SHALL BE TREATED TO COMPLY WITH AWPA STANDARD LP-2. b. ALL BOLTS SHALL BE A611" f A301. ALL BOLT HOLES V16 INCH LARGER THAN BOLT. 1. ALL CONNECTORS INCLUDING NAILS, BOLTS, WASHERS AND NUTS SHALL BE HOT DIPPED GALVANIZED, U.ON. S. PLYWOOD SHALL BE IDENTIFIED WITH GRADE -TRADEMARK OF APA AND MEET THE REQUIREMENTS OF PRODUCT STANDARD PS -I. 9. ROOF SHEATHING OVER PREFAB TRUSSES OR RAFTERS SPACED AT A MAXIMUM OF 24 INCHES ON CENTER SHALL BE A MINIMUM OF 3/4 INCH CD G-2 EXT-APA. INSTALL WITH FACE GRAIN ACROSS SUPPORTS WITH PLY CLIPS AND CONTINUOUS OVER 2 SUPPORTS. NAIL AT 4 INCHES ON CENTER ALONG PANEL EDGES AND INTERMEDIATE SUPPORTS, 21/2" AT DIAPHRAGM BOUNDARIES WITH GALVANIZED 10d ANNULAR RING NAILS. 10. FLOOR SUBFLOOR OVER PREFAB TRUSSES OR JOISTS AT 24 INCHES ON CENTER MAXIMUM SHALL BE A MINIMUM OF 3/4 INCH CD G-1 EXT-APA. INSTALL WITH FACE GRAIN ACROSS SUPPORTS WITH EDGE BLOCKING AND CONTINUOUS OVER 2 SUPPORTS. NAIL AT 3 INCHES ON CENTER ALONG PANEL EDGES AND AT INTERMEDIATE SUPPORTS WITH GALVANIZED 10d COMMON NAILS. STAGGER NAILING WHEN TWO LAYERS OF PLYWOOD ARE SPECIFIED IN STRUCTURAL DRAWINGS. 11. STORE ALL LUMBER AND PLYWOOD ABOVE GRADE OR FLOOR AND PROTECTED FROM WEATHER I. DESIGN STANDARDS SHALL CONFORM WITH THE APPLICABLE PROVISIONS OF THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, NATIONAL FOREST PRODUCTS ASSOCIATION, THE DESIGN SPECIFICATION FOR METAL PLATE CONNECTED WOOD TRUSSES, TRUSS PLATE INSTITUTE AND THE FLORIDA BUILDING CODE. 2. ALL CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 18 GUAGE AND SHALL BE MANUFACTURED FROM STEEL MEETING THE REQUIREMENTS OF ASTM-A653 GRADE 60 AND SHALL BE HOT DIPPED GALVANIZED ACCORDING TO ASTM-A653. COATING DESIGNATION G185. CONNECTOR PLATES SHALL BE APPLIED TO BOTH FACES OF TRUSS AT EACH JOINT, AND SHOULD PROVIDE FIRM EVEN CONTACT BETWEEN THE PLATE AND THE WOOD. 3. QUALITY SHALL BE N ACCORDANCE WITH QUALITY CONTROL MANUAL, TRUSS PLATE INSTITUTE. MAXIMUM TRUSS SPACING IS 24 NCHES ON CENTER TOP AND BOTTOM CHORDS SHALL BE 2X6 INCHES MINIMUM. RIDGE, HIP AND VALLEY BLOCKING SHALL BE REQUIRED, MINIMUM 2X6 INCHES OR CHORD SIZE WITH 2-16d NAILS PER CONNECTION. TRUSSES RESTING ON SLOPED SUPPORT SHALL BE BEVEL CUT TO PROVIDE FULL BEARING, INCREASE LUMBER SIZE IF REQUIRED. 4. TRUSS FRAMING PLAN IS FOR GENERAL. CONFORMANCE AND LAYOUT ONLY. TRUSS MANUFACTURE SHALL BE RESPONSIBLE FOR COMPLETE ENGINEERING DESIGN. 5. ALL TRUSS TO TRUSS CONNECTIONS SHALL BE THE RESPONSIBILITY OF AND DESIGNED BY THE TRUSS MANUFACTURE. A MINIMUM OF TWO, EACH SIDE, SIMPSON HURRICANE ANCHORS SHALL BE REQUIRED AT THE TOP CHORDS AND SIMPSON U HANGERS AT BOTTOM CHORDS, OR APPROVED EQUALS. AS A MINIMUM, PIGGYBACK TRUSSES SHALL BE ANCHORED TO SUPPORTING MEMBERS WITH ONE SIMPSON TWISTED STRAP, WITH 4-trod CLINCHED NAILS PER CONNECTION CAT EACH MEMBER), BENT OVER MEMBERS AT EVERY BEARING POINT AND AT A MAXIMUM SPACING OF 24 INCHES ON CENTER 6. THE CONTRACTOR SHALL COORDINATE THE WORK WITH THE TRUSS MANUFACTURE TO OBTAIN FINAL DIMENSIONS AND ANCHORAGE LOCATIONS WHICH WILL AFFECT THE CONCRETE WORK NO CONCRETE WORK WHICH REQUIRES CONTRACTOR/TRUSS MANUFACTURE COORDINATION SHALL BE STARTED WITHOUT FINAL TRUSS SHOP DRAWINGS APPROVAL. 1. ALL TRIANGULAR TRAPIZODAL OR UNSYMMETRICAL TRUSSES SHALL HAVE WOOD MEMBERS ON OPEN SIDE, OPEN SIDED TRUSSES ARE NOT ALLOWED. MINIMUM SIZE OF TRUSS PLATE AND WOOD MEMBER SHALL BE CAPABLE OF TRANSFERNG FULL UPLILT AND GRAVITY LOADS TO TOP AND BOTTOM CHORDS. S. ROOF SHALL BE LOADED (ROOFING MATERIALS,TILES,SHAKES,ETCJ UNIFORMLY DURING CONSTRUCTION, UNSYMMETRICAL LOADS SHALL BE AVOIDED. 9. ALL TRUSSES MUST BE SECURELY BRACED DURING ERECTION AND AFTER PERMANENT INSTALLATION IN BUILDING, IN ACCORDANCE WITH COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLING AND BRACING METAL PLATE CONNECTED WOOD TRUSSES, TRUSS PLATE INSTITUTE. IN ADDITION, PERMANENT BRACING SHALL BE DESIGNED BY THE SPECIALTY ENGINEER AND AS A MINIMUM SHALL BE AS FOLLOWS; A. BOTTOM AND TOP CHORDSt CONTINUOUS LONGITUDINAL BRACING USING 2X6 MIN. AT 4 FEET ON CENTER LAPPED AT LEAST TWO TRUSSES AND CONNECTED TO CHORDS WITH 2-Irod NAILS. ADD 45 DEGREE DIAGONAL BRACING AT 12 FEET ON CENTER FOR FULL WIDTH OF TRUSS, SIZE AND CONNECTIONS AS INDICATED ABOVE. B. PROVIDE VERTICAL CROSS BRACING AT EACH END OF BUILDING AND AT A MAXIMUM SPACING OF 12 FEET ON CENTER AND EXTEND FOR AT LEAST 3 TRUSSES. BRACING SIZE AND CONNECTIONS AS INDICATED ABOVE. BRACING HORIZONTAL SPACING SHALL BE 6 FEET AT ENDS AND 12 FEET AT INTERIOR- C. PERMANENT WEB BRACING SHALL BE DESIGNED TO FUNCTION INDEPENDENTLY OF THE MAIN STRUCTURE. SCAB OR T BRACING SHALL BE USED FOR ALL WEB MEMBERS. D. TRUSS SUBSYSTEMS AND PIGGYBACK TRUSSES REQUIRE MINIMUM BRACING AND OTHER REQUIREMENTS AS STATED ABOVE. E. TRUSS MANUFACTURE SHALL CONSIDER PERMANENT BRACING REQUIREMENTS DURING TRUSS LAYOUT AND DESIGN. TRUSS LAYOUT OR DESIGN WHICH CANNOT BE READILY PERMANENTLY BRACED WILL NOT BE ACCEPTED. 10. TRUSSES, TRUSS FRAMING PLAN, CONNECTIONS AND BRACING SHALL BE DESIGNED AND SIGNED AND SEALED BY A DELEGATED FLORIDA PROFESSIONAL ENGINEER 11. ALL TRUSSES SHALL BE DESIGNED FOR THE FOLLOWING LOADS; A. ROOFS: TOP CHORD LIVE LOAD 30 PSF TOP CHORD DEAD LOAD 20 PSF BOTTOM CHORD DEAD LOAD 10 PSF TOTAL 60 PSF B. CONCENTRATED LOADS AS INDICATED IN DRAWINGS. C. WIND LOADS PER THE ASCE1-05 FOR HEIGHT, ROOF SLOPE, SHAPE AND PARTIALLY OPEN STRUCTURE AS APPLICABLE. SEPARATE CALCULATIONS FOR WIND LOADS SHALL BE SUBMITTED INDICATING ALL ASSUMPTIONS AND CRITERIA. D. STRESS INCREASE SHALL NOT BE USED FOR STEEL DESIGN OF METAL TRUSS PLATES. E. STORE WOOD TRUSSES ABOVE GRADE OR FLOOR AND PROTECTED FROM WEATHER F. SIGNED AND SEALED BY A FLORIDA P.E. SHOP DRAWINGS ARE REQUIRED. SHOP DRAWINGS SHALL IDENTIFY THE SPECIFIC PROJECT, LIST ALL DESIGN CRITERIA, LIST ALL MATERIAL SPECIFICATIONS, DETAIL ALL CONNECTIONS AND ERECTION REQUI T 1P DRAWINGS SHALL INDICATE THAT THE REQUIREMENTS STATED ABOV1J81� ,AND MET AS gE? SUBMITTED. nc riLDI =,owjiOVEQ Ry' PROJECT No. 10034.00 Kane Residence 6695 SW 69 Ave South Miami, FL OWNER John and Ellie Kane 6695 SW 69 Ave South Miami, FL BIT SET 06/03/11 PERMIT SET 06/23/11 Pablo Corazzini AR - 91716 Luigi Vitalini AR -13513 N r*44% vital inl o ain AR C H I T E C T S 300 Aragon Avenue, Suite 330 1 Coral Gables, FL 33134 tel: 305.567.0602 1 tax: 305.446.3197 1 www.vcmiami.com FL Registration AA26001654 Consulting Civtl/Structural Engineer 141 A-1 AMBRA CIRCLE SHEET NO. SUITE 200 CORAL. GABLES, El. 33134 C305) 561-0125 ES: 00®6813 Rea. No. 4008'1