10-662 (2)-0214'-9," 16'-01, If 41-611 21 PROPERTY LINE. D METAL FENCE ABOVE MASONRY' - WALL, SUBMIT SHOP DRAWINGS AND CALCULATION SIGNED 4 SEALED BY A FL. P.E. FOR APPROVAL PRIOR TO FABRICATION. (TYP') NEW 4'-0' HIGH CBS WALL REINF WITH 45 VERT, 0 48' c% IN BLOCK CELLS FILLED WITH CONC. GROUT, 24'x24' MASONRY COLUMN REIN. WITH 8 05 VERT. AND 02 STIRRUPS A 8' c/c, TYPICAL WHERE SHOWN. jjFAj w •. Existing One Story Residence FOUNDATION NOTES: I. TOP OF EXISTING SLAB IS EL. 0'-0' 2. TOP OF FOOTING ELEVATION SHALL BE EL. -2'-0' 3. FOR COLUMN, BEAMS, BLOCK WALLS AND FOOTING SCHEDULES SEE SHEET S-3. 4. FOR GENERAL STRUCTURAL NOTES, SEE SHEET S-4 4 4A. 5. CONTRACTOR MUST PROVIDE ADECUATE SHORING FOR ALL REQUIRED STRUCTURE PRIOR TO ANY FOUNDATION POUR. Ia. CONTRACTOR MUST PROVIDE TERMITE TREATMENT 4 FUMIGATOR CERTIFICATION REPORT. 1. CONTRACTOR MUST NOTIFY ARCWITECT/ENGINEER IN WRITING OF ANY UNFORESEEN BEARING CONDITION NOT SPECIFIED N THESE PLANS BEFORE PROCEEDING WITH THE WORK. 8. CONTRACTOR MUST COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS AND N THE FIELD, INCLUDING ALL WINDOW AND DOOR MASONRY OPENINGS. NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES. S. PROVIDE 2 05 x6'-O" CORNER BARS AT ALL FOOTING INTERSECTIONS, EXTEND 3'-O" INTO EACH FOOTING. IOALL MASONRY BLOCK WALLS SHALL BE REINFORCED WITH *5 VERTICAL AS SHOWN ON PLANS N BLOCK CELLS FILLED WITH CONCRETE GROUT. 11. PROVIDE 2 45 VERT. EACH. SIDE (JAMB) OF WINDOW OPENINGS WHERE SHODU SOIL STATEMENT: BASED ON VISUAL INSPECTION THE FOUNDATION HAVE BEEN DESIGNED FOR A 20M PSF SOIL BEARING CAPACITY. AT THE TIME THE SOIL IS BROKEN, A SITE INSPECTION MUST BE DONE BY THIS OFFICE IN ORDER TO VISUALLY VERIFY THE ASSUMED SOIL BEARING CAPACITY. LEGEND 'TE' DENOTES SNIV CONC. THICKENED EDGE WITH 2 +5 CON1. (D ME DENOTES NEW CONCRETE COLUMN, SEE SCHEDULE ON 5-1 1111151111111 DENOTES LOAD BEARING REINFORCING BLOCK 5W-1 WALL, SEE SCHEDULE ON S-b MINMUM EDGE MINIMUM EDGE DISTANCE FOR DISTANCE FOR 1/4' 0 WOOD TAPCONS. 2tt 1" MIN. MASONRY BLOCK WALL lx4 OR Ixb P.T. 1/44 x 21V TAPCONS CONTINUOUS BUCK SPACED h' FROM REFER TO NO.A, n EACH CORNER AND REQUIREMENTS. THE REST ® 8' c% MINIMUM REQUIREMENTS MAX. FOR WOOD BUCK TO MASONRY BLOCK KTS. CONNECTION DETAIL STEEL Ix4 OR 1xF6 P.T. CONTINUOUS BUCK COLUMN REFER TO N 0 A. REQUIREMENTS. HILTI KWIK-PRO SELF -DRILLING SCREWS, t/4"-20 WITH WINGS, P14ILLIPS FLAT HEAD, it/z" LONG MINMUM. SPACE SCREWS 6" FROM EACH CORNER AND THE REST * 8" c/a. MAXIMUM. N.TS. . NOTE: THIS BUCK CONNECTIONS MUST BE VERIFIED FOR N.O.A. COMPLIANCE BY THE SPECIALTY GLAZING ENGINEER. ALL LOADS, INCLUDING ALL CONCENTRATED LOADS INDUCED INTO THE BUCK FROM THE DOOR OR WINDOW ASSEMBLY, MUST BE ADDRESSED BY THE SPECIALTY GLAZING ENGNEER IF ANY DEVIATION FROM THIS DETAIL OCCUR IN THE FIE-D, THEN THE BUCK ANCHORAGE MUST BE DESIGNED AND PROVIDED BY A SPECIALTY ENGINEER. WIRE MESH SLAB REIN. SEALANT FILLED SAW -^.UT AT MID DEPTHJONT (TYP. AT ALL CONTROL JONTS) d: I.- DEEP • a x Xti— :�k�--lt WELL COMPACTED FILL—' TYPICAL CONTROL JOINT DETAIL Mij A 1 TCBW_ 1 0 �! / WF-16 �I r I Ise_ (nTC:BW1 J L �-I I -I ,� ZLLF-20 _bj ox_ TE I I F-3 F-3 I I 2 04 DIAL. x 4'-0' TYP. I I I AT ALL CORNERS. I I ( ( I I II I 6■ I I I I Flum,I I I I I I I I I I I I 1 I I I I I I I I I I I NEW 4' CONC. SLAB I I I I RENF. WITH b'xb' I W1.44,11.4. W.W.M. I I I I I I I I I I I K TOP OFS LAB I TC I I I I -tI I I I I I I I TC LI I I I I II! I I I I I I I I I I- I I I I I I I L, j7r _ _ _ _ c.J. _ _ _ _ • I I I 1 FF 35 OIL TOP OF SLAB I I I I EL. -0'-6' I II I I I I I ' NEW 4' CONC. SLAB I I I I I $ REINF. WITH b'xb' ( I I I — S-6 1 1 W14xW14 W.W.M. I I � TCI� I I I I I I I I `QI ( bxb WOOD POST, I I I I I TYPICAL. I I I I II TC I 1VA& CONC. PEDESTAL I• I I I i I I AND #3 STIRRUPS 8' I I I r— J I L—_j c/c., TYPICAL. I I I I I!1 I I I I I I I I I I A DETAIL7 I _ ! ' I F 45 S-I TYP. 1 ( I I II II I I I I I I 5'x8' CONC. SILL REI1F. I I I I I I WITH 2 5 CONT., EXTEND I I I I I I I I 8' MIN, INTO WALL EACH � END. I I I I II I TC I I I I ADD 2 5 TOP AT WF-lb ( I ( I I THRUOUT THIS WALL. I I I I I II I I I I I II I I I I I 11 I I I I� I ri IL - 5 I I 1 1 I I I• I I I I I NO - at T3 L� • L - - - - - - - - - - ----------J !t -- t- �u I 1*1111 19111! ! TE - - c ----------------------------- --- I WF-20 BW-I —BIU-I 5" a...., p. t�•t a BUILDING SECTION 4 ! nwm� PROJECT No. 10034.00 Kane Residence 6695 SW 69 Ave South Miami, FL OWNER John and Ellie Kane 6695 SW 69 Ave South Miami, FL BIT SET 06/03/11 PERMIT SET 06/23/11 Pablo Corazzini AR - 91716 Luigi Vtalini AR -13513 Nfc Vltallnli"III A R C H I T E C T S 300 Aragon Avenue, Suite 330 i Coral Gables, FL 33134 tel: 305.567.0602 I fax: 305,446.3197 I www.vcmiami.com FL Registration AA26001654 Consulting Civil/Structural Englneer 141 ALHAMBRA CIRCLE SHEET NO. SUITE 200 CORAL GABLES, FL 33134 (305) 56 1-0125 EB: 000&S13 Flea. No. 4008-1 5-1