06-240-025HAND SK. C•O.1 \ x PROVIDE 1/2"C.W. \ TRAP PRIMER FOR \ \ FLOOR DRAINS. \ 2„ \ CONNECT TO BUILDING'S EXISTING VENT LINE. \ VERIFY EXACT YR�2 LOCATION IN FIELD I \ CONNECT TO BUILDING'S \ EXISTING VENT LINE. \ VERIFY EXACT 2" LOCATION IN FIELD. HAND 2" SK. C.O.l r / 2,�\ ear I I \ 2ZX i I 2.. I \\\ \ I F.C.O. \ /% LAV 1 C 0 CONNECT TO BUILDING'S SAND \ \ \ 3" EXISTING VENT LINE. I C.O. 2 / / I � O VERIFY EXACT LOCATION IN FIELD. CONNECT TO BUILDING'S T LINE. 2" / / 3„ W.C. C 3 I 2 \ VERIFY EXACT 2" / 3" 2" i1 1 .1x LOCATION IN FIELD. W.C. \ 3 / I \ 2" 3 3"F.0. 31. " 3 3" W.C. \ ,,��,,(( LAV 3" 3 (N) * LAV 2), ,I LAV LAV ``f�VV 2., 3.. 3-� I 3"F.D. 0 / / SAND 2" C.O. C.O. I I 2„ / C 2„ W.C. LAV 3" 3., \ C.0.1 2" 4,. \ \ 3" 4" C.O. W.C. 1 \ \ , C.T.G. 2 2 \ 4XSAN TARY LINE. 3" \ VERIFY EXACT 1 LOCATION IN FIELD. J SINK C.O. \\ 1/2" H 1/2" C.W. • \ I I 1\& C.W. 1/2" C W. � I I LAVA/ ` 3/4" UR. & 1" CA C.W. W.C. 'o 3/4' H.W. 3/4" C.W. Q� 1/2" H.W. 3/4" H & C.W. 1/2" C.W! . 3/4" C.W. 1/2" N.W. W C. I I 1 I LAV W.C. 1/2" C.W.-y I I I LAV W.C. 1/2" C.W. r- CAPPED 1/2" C.W. ABOVE CEILING �\ FOR FOUNTAIN SANITARY RISER N.T.S. CONNECT TO BUILDING'S I13'J YEXISTING VENT VERIFY EXACT LINE. 4"F.F.D. LOCATION IN FIELD. I (NI 4"F.D. 4" I IN) 4 N 4.. 4 :9 4" 4" � �It CONNECT TO BUILDING'S / IN) 4" EXISTING VENT LINE. / 4"F.D. VERIFY EXACT 35 / DISH 41 FED LOCATION IN FIELD / / WASHER REMOVE EXISTING \ \ 12.02" 2" FLOOR DRAIN. CAP WASTE LINE 3'� \ FLOOR SK DIPPER BELOW FINISHED FLOOR 4" > 4" WELLS \ 4. 3y / (E) 2 3 Y \ 3" F.D. / �\ 4" 4\ 4 4.. (E) \/�/I SINK COMP. ./ F.D.I � SINK x PROVIDE 1/2"C.W. I Q� TRAP PRIMER FOR / �3" 4" [� FLOOR DRAINS. i 4" I 2„ FLR 4„ 4" I SK. (El 4" ICE 1 F.D. 4 MACH. 4•, 4" EX 'X DIF 4„ DIF MO (E) VE 4" 3 1C.0 K 4' F.D. 2.. (E) 4, F.D. 2W-C( 12"x12" 4':-92„ \ \ 4" FLOOR SK. (N) \ \ 4"F.D. F FOROEELEZRE/R , D 1 4" 4 CONDENSATE S,*,*. D. (E) 4" 8C 1/2" C.W. \ 1/2" C.W. ARRESTORS I I \ I I o 3/4" H Oo\ & C.W. DISH WASHER ICE CREAM 1/2" H.W. ^ STATION SK. / \ 1/1" H.W. I 1 1/4" C W \ / 1 1/4" C.W. UP 1" C.W. \� 3-COMP I I 1/2" .W `��,�,�p� 3/4" H.W. 1/2" BA KFLOW 3/4" H W. SK. 3/4" C.W. I 1/2" H\� / 1/2" H.W. H.B. & 1/2" H C.W �70 & C.W. 1/2"C.W. / \ BELOW SLAB - \ \\ 3/4" H.W. I Q LAV � ICE. /� I I I I , �O�o \\ `M(�AoCH. LAV fikiCOLD 1/4"C.W. CONNECT TO AV 1/2" H ,00\ ` \ 3/4" .W.I�T�1/2" C.W. VERIFY EXACT LOCATION & CONNECTION & C.W. I I Oro p.� POINT IN FIELD. UPGRADE WATER LINE & 1" C W I 1/2" H '�� METER IF NECESSARY TO ACCOMMODATE I 3/4 H.W. & C.W. \\ 1" L.W. NEW PLUMBING FIXTURES. HANG I I �!00 \ MOP �Ix3/4" H.W. SK. ` \ \ SK. Q . 1" C.W. / 3/4" H.W. I I \ >>Oo 0. 1�p0 1" C W. 3/4" H.W. 1/2" H 1�p & C.W. SINK o /. Apo 1 Q� MIXING& C.W. VALVE HEAT TRAPS WATTS BRVT ---PRESSURE Q_ RELIEF VALVE EXISTING T&P WATER HEATER W H TO BE RE -USED. e; 2"AIR GAP (E) F.D. `17I\ 1/2" H & C.W. C.W. I I I 3/4" H & C.W. 0 1/2" H & C.W. SK. WATER RISER N.T.S. COMBINATION WASTE/ VENT RISER N.T.S. NOTES: 1. PRIOR TO CONSTRUCTION, PLUMBING CONTRACTOR SHALL LOCATE ALL EXISTING WATER, SANITARY, GREASE & GAS LINES. 2. PLUMBING CONTRACTOR SHALL IDENTIFY ALL EXISTING INVERTS. 3. UNUSED EXISTING STUB -UPS AND OTHER SANITARY OPENINGS SHALL BE CAPPED BELOW FINISHED FLOOR. 4. PLUMBING CONTRACTOR SHALL UPGRADE WATER LINE IF NECESSARY TO ACCOMMODATE ALL PLUMBING FIXTURES. 5. PLUMBING CONTRACTOR SHALL NOTIFY ARCHITECT/ENGINEER OF ANY CHANGES NECESSARY TO COMPLETE NEW CONSTRUCTION. 6. NO CHANGES SHALL BE IMPLEMENTED WITHOUT WRITTEN CONSENT OF THE ARCHITECT/ENGINEER. 7. COORDINATE PLUMBING INSTALLATION WITH OTHER TRADES. 8. WATER AND GAS LINES TO BE RUN OVER HEAD UNLESS SHOWN OTHERWISE. 9. PROVIDE SHOCK ARRESTORS ON ALL DISHWASHER WATER LINES. SIOUX CHIEF MOD # 652-A/653-B 10. SEE PLUMBING RISERS ON SHEET P2.01 FOR ALL PIPE SIZES. 11. ALL PLUMBING FIXTURES TO COMPLY WITH TABLE 604.4 OF F.B.C. (PLUMBING) PLUMBING LEGEND I — — — — — COLD WATER LINE — - 1102 - - 1102 - — 110° HOT WATER LINE 1402. 1402• 140• HOT WATER LINE SANITARY LINE WASTE/ VENT LINE G GAS LINE ® 12" x 12" FLOOR SINK DIS FLOOR DRAIN N SHUT-OFF VALVE BIBB WITH S.O.V. H B +HOSE & VACUUM BREAKER A.A.V. AIR ADMITTANCE CHAMBER REVISION 02/24/06 PERMff SE1`• 11/30/05 NOTE: ANY DESIGN CHANGES, TO THE SYSTEM COVERED BY THESE PLANS WITHOUT PRIOR APPROVAL OF THE ENGINEER WHO PREPARED THESE PLANS, WILL NULL AND VOID THESE PLANS AND THE REVISED INSTALLATION. IN ADDITION, ALL EXPENSES ASSOCIATED WITH RETURNING THE SYSTEM TO ITS ORIGINAL DESIGN WILL BE THE RESPONSIBILITY OF THE COMPANY WHICH APPROVED THESE CHANGES 11191 g/11111 FORMICA & F1111ASSOCIATES. Consulting Engineers 3100 N.W. Boca Raton Blvd. Suite #117 Boca Raton, R 33431 T 1) 368-3611 FAX (561) 368-4733 •��` 0 Certificate #00008818 t' 01 �iobad F. Formica, P.E. • G ! ca0f imicaengineedrig.com C, ,• SUA• r. S°. w Y.4y►�1. co o �� O� NcD M-) 7 4? _L 7 �LO M U Cp LO `O d E LU b N 4` M p ~ LL [i0 v Marcetto Penso AR0016862 W � � W X 0 (__-.E E)/o^ 2: O v/ - L1— CD � M U U N N a d 1. 8LD0. DEPT. OM ENT 02-24-06 no. revision date Phase: issued for permit Sheet, plumbing risers & notes Scale' as noted R•1` 25373 Drown• CPG/KEB 0*1 WF F0, ArrA 01 P 2. 01 01 Architedus. Incorporated reserved