Loading...
06-240-023� , I - SCOPE OF WORK r — — — — —-- — — — — — — — — — r.r_.:.I. — — — — �.. --- — — — —I r. L �1fl t EXISTING= V. _ �V II - _._ - - ----ter ir'�.Li�r-4� , :c•:� Ij j I I �r,F r1 I EXI TING SUPPLY-bUCT sir,Q C I -=��� I �- ---- r-------- ----------------_'= i.=--_------'I 11 it L ------ I y I A e i I _s- I i _ - =-a ! F EF-2 ;il f ��- ! ! I .aI EF ^�� 150 CFM --- -- L- — 1 ; I ; lY -- IfiRO`�FM - II I ----- ---------------•- - -- CONNECT NEW 8;;0-------------------•--------------- �j ( METAL DUCT FROM i EXHAUST FANS UP TO NEW ROOF CAP WITH 8x8 METAL DUCT. L---------------------------------------------- J SCOPE OF WORK CONTRACTOR TO VERIFY LOCATION OF EXISTING SUPPLY DUCT IN THE FIELD AND CONNECT NEW SUPPLY TAKEOFFS AS SHOWN. MECHANICAL PLAN SCALE 1/4" = l' 0" SHEET METAL EXHAUST DUCT ROUND OR RECTANGULAR HANGER PARE TYPICAL CEILING CABINET EXHAUST FAN PATH BACKDRAFT DAMPER, LOW NOISE LEVEL AND NO VIBRATION. FRONT FACE GRILLE VA7H FASTENING SCREENS 'EXHAUST FAN HANOING BRACKET (AMIUSTABLE) CEILING- MOUNTED CABINET EXHAUST DETAIL NTS SET FLANGE IN PLASTIC CEMENT SECURE TO ROOF AND CAULK WATERTIGHT ALL AROUND ROOF CAP 8 " MIN .----- -- BIRDSCREEN SEE ARCH. DWG. FOR ROOF CONSTRUCTION SEE PLAN FOR DUCT SIZE m ROOF CAP DETAIL N TS AIR DISTRIBUTION SCHEDULE SYMBOL SERVICE DESCRIPTION MFG. MODEL NO. A CEILING SUPPLY REGISTERS PERFORATED SUPPLY CEILING DIFFUSER. ALUMINUM CONSTRUCTION, FLUSH FACE PANEL FINISH SHALL BE MITE ENAMEL 24'x2e MODULE SIZE WITH ROUND NECK SIZES AS SHOWN ON PLANS. TITUS INDUSTRIES INC. MODEL NO. PCS-AA BATHROOM EXHAUST FAN SCHEDULE SYMBOL EF-1 EF-2 LOCATION CEILING CEILING SERVICE MEN'S TOILET WOMEN'S TOILET MAKE GREENHECK GREENHECK MODEL SP-A190 SP-A190 BLOWER DATA C.F.M. 150 150 S.P. 0.25 INCHES 0.25 INCHES TYPE CEILING MOUNTED CEILING MOUNTED DRIVE DIRECT DIRECT aMECH H.P. 110 WATTS 110 WATTS R.P.M. 1400 1400 o ml ELEC V 120 120 PH 1 1 HZ 60 60 WT LB S. 15 15 DIMENSIONAL DATA 8"x6" 8"x6" REMARKS BACKDRAFT DAMPER DISCONNECT SWITCH ROOF CAP VIBRATION ISOLATORS CONNECT TO LIGHTS BACKDRAFT DAMPER DISCONNECT SWITCH ROOF CAP VIBRATION ISOLATORS CONNECT TO LIGHTS 1 1 /2- MIN 116 1 1 /2- BAND CLAMP VG NOT TO EXCEED G NOT TO EXCEED 5' INTERVAL GAUGE THK. 1" STRAP CAPABILITY MAXIMUM LOAD 24 .028 840 168 22 .034 1070 216 20 .040 1298 259 * ELASTIC LIMIT ASSUMED � s 30ksi; RECOMMEND MAX LOAD NOTES: (20% OF YIELD STRENGTH). 1. FLEX DUCT WITH EXTERNAL INSULATION AND VAPOR BARRIER JACKETING TYPICAL TO "FABRIFLEX" 2. "INSPECTOR SERIES" SPIN DOORS SUPPORT REQUIREMENTS FOR FLEX DUCT NTS 1" X 22 GUAGE BAND FLEXIBLE DUCT,SEE PLANS FOR SIZE. MINIMUM RADIUS EQUAL TO ONE DUCT DIAMETER. INSULATION MECHANICAL NOTES 1. DO NOT SCALE THE DRAWINGS. REFER TO ARCHITECTURAL PLANS FOR ALL DIMENSIONS. 2. COORDINATE EXACT LOCATION OF ALL DIFFUSERS AND RETURNS WITH ARCHITECTURAL REFLECTED CEILING PLAN. 3A. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FLORIDA BUILDING AND MECHANICAL CODE, NFPA-90A, AND LOCAL CODE AMENDMENTS. 3B. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODE— NFPA-90A AND LOCAL CODE AMENDMENTS 4. ALL OUTSIDE AIR DUCTS OR INTAKES SHALL HAVE DAMPERS. 5, ALL VENTILATION DUCTS SHALL BE SHEET METAL, INSTALLED, SEALED AND SUPPORTED IN ACCORDANCE WITH THE LATEST EDITION "SMACNA" LOW VELOCITY DUCT CONSTRUCTION STANDARDS AND DETAILS ON THESE PLANS. 6. ALL EXHAUST DUCT SHALL BE SHEET METAL, INSTALLED, SEALED AND SUPPORTED IN ACCORDANCE WITH THE LATEST EDITION OF "SMACNA" LOW VELOCITY DUCT CONSTRUCTION STANDARDS AND DETAILS ON THESE PLANS. 7. AIR CONDITIONING SUPPLY & RETURN DUCTS SHALL BE FIBERGLASS, TYPE 800 El INSTALLED, SEALED AND REINFORCED IN ACCORDANCE WITH THE LATEST EDITION OF "NAIMA" FIBROUS GLASS DUCT CONSTRUCTION STANDARDS AND DETAILS ON THESE PLANS. 0-1" STATIC PRESSURE CLASS, (+/—), UNLESS OTHERWISE NOTED. 8. ALL AIR CONDITIONING DUCTWORK SHALL BE RIGID FIBERGLASS DUCT BOARD. INSTALLED IN ACCORDANCE WITH NAIMA, FIBROUS GLASS DUCT MANUAL. ALL DUCT IN ATTIC SPACE SHALL BE R-6.0 MINIMUM. DUCT WORK BETWEEN FLOOR OR CONDITIONED SPACE SHALL BE R-4.2 MINIMUM. FLEX DUCT R-4.2/6.0 SHALL BE USED IF THERE IS LIMITED SPACE. 9. FLEXIBLE DUCTS SHALL BE R-6.0 MINIMUM UL 181 CLASS 1 CONSTRUCTED WITH A POLYESTER LAMINATED SMOOTH INNER CORE THAT ENCAPSULATES A STEEL WIRE HELIX. THE DOUBLE CORE IS WRAPPED IN A THICK BLANKET OF FIBERGLASS INSULATION AND SHEATHED IN A REINFORCED METALLIZED POLYESTER JACKET. Date: 02-20-06 Checked by. Drawn by. M B Revisions: 10. REFRIGERANT PIPING SHALL BE COPPER, REFRIGERATION GRADE, SOFT TEMPER, SEALED AT THE MILL. INSULATE SUCTION PIPE INDOORS: WITH 3/8" IMCOA POLYOLEFIN INSULATION; OUTDOORS: 3/4" IMCOA POLYOLEFIN INSULATION. CIRCULATE DRY NITROGEN THROUGH PIPING WHEN SOLDERING. TEST FOR LEAKS PRIOR TO CHARGING SYSTEM WITH nn ll R-22 REFRIGERANT. �---� (nD W W 11. CONDENSATE DRAINS SHALL BE SCHEDULE 40 PVC PIPING OR COPPER �— IF LOCATED IN A RETURN AIR PLENUM. W X E 0:�: 0 EYE SCREW #12 WIRE CEILING DIFFUSER SEE PLANS AND SCHEDULE. CONNECT FLEXIBLE DUCT TO COLLAR WITH 22 GUAGE CLAMP AND FOUR SHEET METAL SCREWS AND SEAL WITH DUCT TAPE /-- CEILING INSULATED BACK DIFFUSER DETAIL OF DIFFUSER NTS MICHAEL A. BASSFO 01.111 �►::''' ` 1402 N.E. 34TH COURT OAKLAND PARK, FL 33334 MICHAEL A. BASSFORD FLORIDA LICENSE #57390 � �. � I• • • %. •1''A4C4� 58i ;•• curl '-. r n • 298-0700 mml