06-240-021MFG. EXISTING TYPE EXISTING PANEL RATING EXISTING 200 AMPS VOLTS 120/208V 304W PANEL "B" EXISTING POS 40 BUS KVA LOAD COND. WIRE SIZE POLE AMPS CKT. BUS CKT. AMPS POLE WIRE SIZE COND. LOAD BUS KVA A B C B C 1.4 REST RM/WORK RM LTNG xx E I S T I N G 20 1 2 20 E X I S T 114 G TRACK LTNG xx 1.6 09 KITCHEN GENERAL LTNG xx E I S T I N G 20 3 4 20 E X I S T I G TRACK LTNG xx 16 0.8 TRACK LTNG xx E I S T I N G 20 5 6 20 E X I S T I P, I G TRACK LTNG xx 1.6 0.8 TRACK LTNG xx E I S T I N G 20 7 8 20 E X I S T I P, I G TRACK LTNG xx 1.6 1.25 PENDANT LTNG xx E I S T I N G 20 9 10 20 E X I S T I IA G TRACK LTNG xx 1.6 1.5 SIGN CIRCUIT x E I S T I N G 20 11 12 20 E X I S T I PI G TRACK LTNG xx 1.6 - SPARE x E I S T I N G 20 13 14 20 EXIST 1 G TRACK LTNG xx 1.95 0.5 VEF-1 x E I S T I N G 20 15 f 16 20 E X I S T I G TRACK LTNG xx 1.95 0.5 VEF-2 x E I S T I N G 20 17 18 20 1 EXISTI G TRACK LTNG xx 1.95 15 TRACK LTNG xx I S T I N G 20 19 20 20 E X I S T I G TRACK LTNG xx 195 1.5 TRACK LTNG xx I S T N G 20 21 22 20 E X I S T I G NEON RECP. x 1.0 1.5 TRACK LTNG xx I S T I N G 20 23 24 20 E X I S T I G NEON RECP. x 1.0 15 TRACK LTNG xx I S T I N G 20 25 26 20 E X I S T I G NEON RECP. x 10 091 RECESSED LTNG xx RE ISTING 20 27 28 20 EXISTI G NEON RECP. x 10 0.18 CONY. RECP. x I S T I N G20 29 30 20 - - - SPARE0.5 TELE.RECP. x I S T I N G 20 31 32 20 E X I S T I G NEON RECP. x 1.0 1.3 PENDANT LTNG xx I S T I N G 20 33 34 20 E X I S T I G NEON RECP. x 1.0 1.95 RECESSED LTNG xx I S T N G 20 35 36 20 E XI S TIrIG NEON RECP. x 1.0 1.95 PENDANT LTNG xx E I S T N G 20 37 38 20 E X I S T I G NEON RECP x 1.0 - SPACE - - - - 39 40 20 E X I S T I G CONV RECP x 0.36 REMARKS KVA OA 17.75 KVA OB 14.87 KVA OC 13.58 1. EXISTING PANEL. 2 ALL BREAKERS AND CIRCUITS THAT DO NOT PERTAIN TO ANYTHING THAT IS 'EXISTING -TO -REMAIN' SHALL BE REMOVED la 1479 AMPS Ib 1239 AMPS Ic 1132 AMPS 3. REROUTE EXISTING CIRCUITS, WHICH ARE TO REMAIN, TO NEW PANELS AT THE NEW PANEL LOCATION. 4. TAG EXISTING BRANCH CIRCUITS. S. x EXISTING; VERIFY IN FIELD. FEEDER SIZE EXISTING CONDUIT SIZE EXISTING 6 xx NEW CIRCUITS; EXISTING BREAKER MAY REMAIN IF IN LIKE -NEW CONDITION MOUNT SURFACE MIN A I C 22,000 AMPS MFG. EXISTING TYPE EXISTING PANEL RATING EXISTING 200 AMPS VOLTS 120/208V 304W PANEL "C" EXISTING POS 40 BUS KVA LOAD COND. WIRE SIZE POLE AMPS CKT. BUS CKT. AMPS POLE WIRE SIZE COND. LOAD BUS KVA A B ( B C 10 U C. REF. xx 1/2" 12 1 20 1 0 2 20 1 12 1/2" KITCHEN RECP. xx 05 1.2 MICROWAVE xx 1/2" 12 1 20 3 4 20 EXISTIrAG D W EXHAUST FAN x 0.5 1.0 PREP AREA RECP. xx 1/2" 12 1 20 5 6 20 1 12 1/2" REST RM RECP xx 0.5 1.0 PREP AREA RECP. xx 1/2" 1 12 i 1 20 7 8 20 1 12 1 1/2" SALAD BAR PWR. xx 0.8 0.5 EQUIP. RECP. xx 1/2" 12 1 20 9 10 20 1 12 1/2" DESSERT BAR PWR xx 0.8 05 EQUIP. RECP. xx 1/2" 12 1 20 11 12 20 1 12 1/2" ICE CREAM BAR PWR xx 04 0 68 TV PWR/CONV. RECP xx 1/2" 12 1 20 13 14 20 1 12 1/2" RECIRC FOUNTAIN PWR xx 0 5 0.5 ANSUL SYSTEM x 1/2" 12 1 20 1S 16 20 1 12 1/2" CONV. RECP. xx 0.54 2.0 HOT FOOD COUNTER PWR. xx 3/4" 10 2 25 17 18 20 1 12 1/2" REST RM RECP. xx 0.5 2.0 S S S S 19 20 20 1 12 1/2" HOSTESS STATION PWR xx 0.4 2.0 HOT FOOD COUNTER PWR xx 3/4' 10 2 25 21 22 S 1 12 1/2" HOSTESS STATION PWR xx 0.4 10 S S S S 23 24 20 1 12 1/2" WINE CABINET PWR xx 04 2.5 ICE CREAM MACHINE x EXISTING 2 30 25 26 20 EXISTI G GAS WATER HEATER x 0.2 2.5 S S S S 27 28 1 20 2 EXISTING COOFFEE MACHINE x 1.0 0.8 WAITRESS STATION RECP. xx EXISTING 2 20 29 30 S S S S 1.0 0.8 WAITRESS STATION RECP. xx S S S S 31 32 30 2 EXISTING SPARE xx - 10 REF. x E I S I N G 20 33 34 S S S S SPARE xx - 10 REF. x E I S ING 20 35 36 20 EXISTIr4G TEA MACHINE x 1.0 3.5 LARGE ICE MACHINE x EXISTING 2 40 1 37 38 20 E X S T I G TEA MACHINE x 1.0 3.5 S S S S 39 40 20 E X STI G COOKING LINE REF. x 1.0 REMARKS 1 EXISTING PANEL KVA OA 14.88 KVA OB 15.44 KVA OC 11.1 2. ALL BREAKERS AND CIRCUITS THAT DO NOT PERTAIN TO ANYTHING THAT IS 'EXISTING -TO -REMAIN' SHALL BE REMOVED. 3. REROUTE EXISTING CIRCUITS, WHICH ARE TO REMAIN, TO NEW PANELS AT la 124.0 AMPS Ib 128.7 AMPS Ic 92.5 AMPS THE NEW PANEL LOCATION. 4 TAG EXISTING BRANCH CIRCUITS 5. x EXISTING; VERIFY IN FIELD. FEEDER SIZE EXISTING CONDUIT SIZE EXISTING 6. xx NEW CIRCUITS, EXISTING BREAKER MAY REMAIN IF IN LIKE -NEW CONDITION. MOUNT SURFACE MIN. A I C. 22,000 AMPS FLOOR DUPLEX MOUNTING DETAIL NOT TO SCALE MFG. EXISTING TYPE EXISTING PANEL RATING EXISTING 400 AMPS VOLTS 120/208V 304W PANEL "D" EXISTING POS 42 BUS KVA LOAD COND. WIRE SIZE POLE AMPS CKT. BUS CKT. AMPS POLE WIRE SIZE COND. LOAD BUS KVA A B C B C 4.5 RTU-1 x EXISTING 3 70 1 2 70 3 EXISTING RTU-3 x 4.5 45 S S S S 3 4 S S S S 45 4.5 S S S S 5 6 S S S S 4.5 4.5 RTU-2 x EXISTING 3 70 7 8 70 3 EXISTING RTU-4 x 4.5 4.5 S S S S 9 10 S S S S 4.5 4.5P2.0 S S S S 11 12 S S S S 4.5 2.0 KEF-IA x EXISTING 3 20 13 14 20 3 EXISTING KSF-1A x 1.0 2.0 S S S S 15 16 S S S S 1.0 S S S I S 17 18 S S S S 1.0 20 KEF-1B x EXISTING 3 20 19 20 20 3 EXISTING KSF-1B x 10 2.0 S S S S 21 22 S S S S 1.0 2.0 S S S S 23 24 S S S S 1.0 - SPARE EXISTING 3 45 25 26 60 3 EXISTING WALK IN COOLER PANEL x - - SPARE S S S S 27 28 S S S S - - SPARE S S S S 29 30 S S S S - 2.0 NEW HOOD EXHAUST FAN xx 3/4" 10 3 20 31 32 20 3 11 1/2" NEW HOOD SUPPLY FAN xx 1.0 2.0 S S S S 33 34 S S S S 1.0 2.0 S S S S 35 36 S S S S 1.0 - SPACE - - - - 37 38 20 E X I S T I G ROOF RECP. x 0.54 - - - - - 39 1 1 4 40 20 E X I S T I 14 G DISHWASHER x 3 0 - - - - - 41 42 S S S S 3.0 REMARKS: 1. EXISTING PANEL KVA OA 3334 KVA OB 358 KVA OC 358 2. ALL BREAKERS AND CIRCUITS THAT DO NOT PERTAIN TO ANYTHING THAT IS 'EXISTING -TO -REMAIN' SHALL BE REMOVED 3 REROUTE EXISTING CIRCUITS, WHICH ARE TO REMAIN, TO NEW PANELS AT la 277.8 AMPS Ib 298.3 AMPS Ic 298.3 AMPS THE NEW PANEL LOCATION 4 TAG EXISTING BRANCH CIRCUITS 5. x EXISTING; VERIFY IN FIELD. 6. xx NEW CIRCUITS; EXISTING BREAKER MAY REMAIN IF IN LIKE -NEW CONDITION. FEEDER SIZE EXISTING CONDUIT SIZE EXISTING MOUNT SURFACE MIN A I C. 22,000 AMPS EXISTING EXISTING FEEDERS FEEDERS EXISTING W.W. ELECTRICAL RENOVATION NOTES: 1. ELECTRICAL CONTRACTOR SHALL MAKE A THOROUGH SURVEY OF EXISTING ELECTRICAL SYSTEM AND FAMILIARIZE HIMSELF WITH IT, AND WITH THE NEW ELECTRICAL SYSTEM PROPOSED, PRIOR TO INSTALLATION. 2. ALL EQUIPMENT SCHEDULED TO BE REUSED, SHALL BE RECONDITIONED TO LIKE NEW. IF COST TO REPAIR OR RECONDITION EXCEEDS NEW COST, THEN THE EQUIPMENT SHALL BE REPLACED. 3. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECONNECTING ALL ELECTRICAL EQUIPMENT IN ORDER TO HAVE A COMPLETE WORKING JOB WHETHER OR NOT THE EQUIPMENT IS SHOWN ON NEW ELECTRICAL PLANS. 4. DUE TO THE NATURE OF THIS PROJECT, THE ELECTRICAL CONTRACTOR MUST CHECK OUT ALL EXISTING CIRCUITS STARTING AT THEIR DISTRIBUTION POINT IN ORDER TO SEE IF THEY ARE STILL ALIVE. 5. WHEN INSTALLING NEW EQUIPMENT, THE ELECTRICAL CONTRACTOR SHOULD USE EXISTING CONDUITS AND AVAILABLE CIRCUITS IF POSSIBLE. ALL REUSED CIRCUIT BREAKERS, OUTLETS, SWITCHES, ETC., SHALL BE INSPECTED AND REPLACED AS NEEDED. 6. TAG EXISTING BRANCH CIRCUITS AND ONLY REUSE THOSE THAT ARE IN LIKE -NEW CONDITION AND COINCIDE WITH THE PLANS. 7. SPACES HAVE BEEN LEFT IN PANEL, IF BRANCH CIRCUITS HAVE BEEN MISSED. ALL ELECTRICAL EQUIPMENT REMOVED SHALL BE KEPT IN A SECURE AREA UNTIL OWNERS DECIDE WHAT TO DO WITH IT. 8. THE ELECTRICAL CONTRACTOR SHALL NOT OVERLOAD ANY EXISTING PANEL BOARDS OR FEEDERS, AND NOT TO EXCEED 80% OF THEIR RATED VALUE. 9. ELECTRICAL CONTRACTOR SHALL VERIFY ALL ELECTRICAL REQUIREMENTS FOR ALL EXISTING EQUIPMENT TO REMAIN PRIOR TO CONSTRUCTION. 10. SPACES HAVE BEEN LEFT IN NEW PANEL BOARD SO THAT EQUIPMENT OR CIRCUITS MISSED MAY BE CONNECTED. 11. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY PROBLEMS DURING CONSTRUCTION BEFORE PROCEEDING WITH THE PROJECT. 12. TOTAL ELECTRICAL SYSTEM TO BE INSPECTED BY ELECTRICAL CONTRACTOR AND BROUGHT UP TO CODE. 13. THE INTENT OF THE ELECTRICAL DESIGN IS TO UTILIZE AS MUCH OF THE ELECTRICAL EQUIPMENT AS POSSIBLE, THEREBY ELIMINATING EXCESSIVE COST, CONSTRUCTION, AND TIME. EXISTING WEATHER HEADS EA. 120/208V 304W EXISTING EXISTING WIRE WAY FEEDERS EXISTING EXISTING FEEDERS FEEDERS • „NO i ALL.ATtUN OF kUv(,th ELECTRIC WIRING CHECK NAMEPLATE DATA OF A/C EQUIPMENT, HOT WATER HEATERS AND OTHER EQUIPMENT TO OBTAIN CORRECT WIRE SIZES AND OVERCURRENT PROTECTION. ADEQUATE SERVICE CAPACIP' , . MUST BE PROVIDED. SUBJECT TO ELECTRICAL i INSPECTION VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO ANY CONSTRUCTION. KISTING _EDERS SUBJECT TO FLORIDA BUILDING CODE PL S OCA ENDMEN S i B BY: EXISTING EXISTING I "Do' i"•[", ' "B" 400 AMP O 400 AMP 120/208V 120/208V I 3�4W EXISTING 3�4W I EXISTING PANEL EXISTING PANEL EXISTING PANEL METER EXISTING FEEDERS EXISTING POWER RISER N.T.S. EXISTING FEEDERS GRADE 1. DO NOT SCALE THE ELECTRICAL DRAWING. REFER TO THE ARCHITECTURAL PLAN AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT AND CONFIRM WITH OWNERS REPRESENTATIVES. 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITIONS OF THE NATIONAL ELECTRICAL CODE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES. 3. UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER, WITH "THHN" INSULATION FOR SIZE #10 AND SMALLER. CONDUCTORS LARGER THAN #10 SHALL HAVE "THWN" INSULATION. ALL CONDUCTORS #10 AND SMALLER MAY BE SOLID. ALL CONDUCTORS #8 AND LARGER SHALL BE STRANDED. 4. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. 5. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK MAKE, QUICK BREAK, WITH ENCLOSURES AS REQUIRED BY EXPOSURE. 6. THESE PLANS DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION, THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND MEET ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 7. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED IN ARTICLE 250, NATIONAL ELECTRICAL CODE. 8 ALL MATERIALS SHALL BE NEW AND SHALL BEAR U L LABELS WHERE APPLICABLE 9 ALL WORK SHALL BE PERFORMED BY A LICENCED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANSHIP MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY ENGINEER/ARCHITECT MUST BE A CONDITION OF THE SUBCONTRACTOR 10. THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF POWER, LIGHT COMPANY AND TELEPHONE COMPANY. 11. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZE. THE CONTRACTOR SHALL PROVIDE CIRCUITS TO SUIT JOB CONDITIONS. 12. SEE NOTES ON PLANS FOR OTHER REQUIREMENTS. 13. FURNISH AND INSTALL LIGHTING FIXTURES AND LAMPS AS CALLED FOR ON PLANS, OR AS SELECTED BY OWNER. 14. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. 15. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY PHASE OF THE INSTALLATION WHICH MAY BE DAMAGED. 16. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 17 CHECK ALL EQUIPMENT FOR PROPER VOLTAGE, PHASE, AND CURRENT BEFORE CONNECTION TO CIRCUITS. 18. ELECTRICAL CONTRACTOR SHALL CHECK AND VERIFY EQUIPMENT FURNISHED AGAINST THOSE SPECIFIED OR INTENDED AND REVISE BRANCH CIRCUITS AS MAY BE REQUIRED WITH PRIOR APPROVAL OF ENGINEER/ARCHITECT. AIR CONDITIONING EQUIPMENT AND CONTROLS SPECIFICATION E p - N (Dv) O Cn NO 00 N m 0) N rO O t-4 O � U a� -I- J ` LL d' M M U Li p - co to •� Ln Lo w Eu) x 3 cD o 0 3 m a3 c'c aUi'c �' ._cam 0 `ate Q Marcello Penso AR0016862 1. ELECTRICAL CONTRACTOR SHALL INSTALL ALL CONTROL RACEWAY (CONDUIT), WIRE INSTALLATION, CONNECTIONS ETC. IN ACCORDANCE WITH WIRING DIAGRAMS ON AIR EQUIPMENT. 2. A/C / ELECTRICAL PLANS OR DIAGRAMS FURNISHED BY MANUFACTURER OF THE EQUIPMENT. 3. ALL POWER WIRING FOR THE AIR CONDITIONING EQUIPMENT SHALL BE FURNISHED, INSTALLED AND CONNECTED UNDER THIS SECTION OF THE SPECIFICATION. 4 MECHANICAL CONTRACTOR SHALL PROVIDE MOTOR STARTERS FOR ALL AIR CONDITIONING EQUIPMENT. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONECTIONS TO AIR CONDITIONING EQUIPMENT PER MANUFACTURERS SPECIFICATIONS. S. AIR CONDITIONING EQUIPMENT INCLUDES CONDENSOR, COMPRESSOR AND FAN, FAN COIL ` UNITS, ELECTRICAL STRIP HEATER, THERMOSTAT, ETC. f '' ELECTRICAL SPECIFICATIONS r T i, •x NOTES: `'� ',:• .y 1. CONTRACTOR TO VERIFY ALL KITCHEN ELECTRICAL REQUIREMENTS PRIOR TO BID/CONSTRUCTION. 2. VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO ANY CONSTRUCTION. W PLAN DEVIATION (CHANGE) t'" EFOREMUST DE tit u."Id0 INSPEC ITi0N REQUEST 'SUBJECT TO D INSPECTION " ANY DESIGN CHANGES, TO THE SYSTEM COVERED BY THESIE'PLANS WITHOUT PRIOR APPROVAL OF THE ENGINEER WHO PREPARED THESE PLANS, WILL NULL AND VOID THESE PLANS AND THE REVISED INSTALLATION. IN ADDITION, ALL EXPENSES ASSOCIATED WITH RETURNING THE SYSTEM TO ITS ORIGINAL DESIGN WILL BE THE RESPONSIBILITY OF THE COMPANY WHICH APPROVED THESE CHANGES. III FORMICA & )III ASSOCIATES Inc. Consulting Engineers 3100 N.W. Boca Raton Blvd. Suite #117 Boca Raton, FI 33431 jTEL: ( 1).368-3611 FAX: (561) 368-4733 1� c;ffllmw 18 Jd lRob orynice.P.E. •' � r /� %�' *19733 •;G S' i rtnk,aengkteering.=n no, revision date , Phase: issued=_f_dr= perr>iit Sheet: - - ?3lectric�al^ pan-(�r5, ^ data;^risers, - 8c -Specs Scale: as noted Prj: 25373 ' ^ Drawn: CPG/KEB Chk: RFF E 3. 0 1 sheet 3 of 3 �pyrlght CQ M Architectus, Incorporated QI nahts reserved