05-1855-008►1F6_ -EXISTING - - - - TYPE EXISTING PANEL RATING EXISTING 200 AMPS VOLTS 120/208V 304W PANEL "B" EXISTING POS 40 BUS KVA LOAD ---- COND. E E WIRE SIZE I S T I S T POLE I N G I N G AMPS 20 20 CKT. 1 3 BUS CKT. 2 4 AMPS 20 20 POLE E X I E X I WIRE SIZE S T I N1 S T I COND. G G LOAD BUS KVA A C B C ^ _ TRACK LTNG xx TRACK LTNG xx 1.6 B 1.6 C 1.4 ^- - - REST RM/WCAK RM LTNG xx - 0.9 - ---1 K17ChcN GNckAC LTNG xx 0.8 TRACK LTNG xx E ISTING 20 5 6 20 EXISTI G TRACK LTNG xx 1.6 0.8 TRACK LTNG xx E I S T N C3 20 7 8 20 E X I S T I G TRACK LTNG xx 1.6 1.25 PENDANT LTNG xx E I S T I N G 20 9 10 20 E X I S T I G TRACK LTNG xx 1.6 1.5 SIGN CIRCUIT x E I S T I N G 20 11 12 20 E X I S T I N G TRACK LTNG xx 1.6 - SPARE x E I S T I N G 20 13 14 20 EXISTIN G TRACK LTNG xx 1.95 0.5 VEF-1 x E I S T I N G 10 15 16 20 E X I S T I G TRACK LTNG xx 1.95 0.5 VEF-2 x E I STI N G 20 17 18 20 EXISTIN G TRACK LTNG xx 1.95 1.5 TRACK LTNG xx E I S T I N G 20 19 20 10 E X I S T I N G TRACK LTNG xx 1.95 1.5 TRACK LTNG xx E I S T I N G 20 21 22 20 E X I S T I N G NEON RECP. x 1.0 1.5 TRACK LTNG xx E I S T I N G 20 23 24 20 E X I S T I G NEON RECP. x 1.0 1.5 TRACK LTNG xx E I S T I N G 20 25 26 20 EXISTIN G NEON RECP. x 1.0 0.91 RECESSED LTNG xx E 1 S T I N G 20 27 28 20 EXISTIN G NEON RECP. x 1.0 0.16 CONV. RECP. x E I S T I N G 20 29 30 20 - - - SPARE - 0.5 TELE. RECP. x E I S T I N G 20 31 32 20 EXI,STIN G NEON RECP. x 1.0 1.3 PENDANT LTNG xx E I S T I N G 20 33 34 20 EXISTIN G NEON RECP. x 1.0 1.95 RECESSED LTNG xx E I S T I N G 20 35 36 20 E X I S T 14 G NEON RECP. x 1.0 1.95 PENDANT LTNG xx E I S T I N G 20 37 38 20 E X I S T I G NEON RECP. x 10 - SPACE - - - - 39 40 20 E X I S T I G CONV. RECP. x 1.0 REMARKS KVA OA 17 75 KVA oB 15.51 KVA OC 13.58 1. EXISTING PANEL. -- -- --- -- 2. ALL BREAKERS AND CIRCUITS THAT DO NOT PERTAIN TO ANYTHING THAT IS 'EXISTING -TO -REMAIN' SHALL BE REMOVED. r i F � T � qN�S �:n �� J"�vpc � I,� � AI,I;>S 3. REROUTE EXISTING CIRCUITS, WHICH ARF. TO REMAIN, ,G NEW PANELS AT -------- ---------_-W_--------- �__ _-___�-_.__..-.__ __ THE NEW PANEL LOCATION. 4 TAG EXISTING 9RAN'H !R UITS � C C C 11 r r , A C � C, .0 CI (, F I `fir^F. , IJE LKI -'N;• r ;< NEW ;!RCUITS; EXISTING BREAK,'R MAY RE:'IAlti „ IN LIKE-NFW COND'T1^N I.. - - --- -- - _ _ _ -lea �,"v' MFG EX'S !NC ---TYPE _--�Xt,PNr -- -_ PANEL RATING EXISTING 200 AMPS VOLTS 120/205V 304W PANEL (" EXISTING POS 40 -------- - - BUSBUS KVA K C LOAD ----- i--`- ICOND �dIRE ��r ! I PGLE �--T 1 AMPS j CKT �- ! BI;S CKT AMPS ! PILE WIRE COND - I LOAD BUS KVA A B C F i 0 --_ __- _-- 1 U.C. REF. t 1 I SIZE _ xxT i/2'_�-12 20 1 2 20 1 12 1/2" KITCHEN RECP xx 05 1 2 10 MICROWAVt _ xx PREP AREA RECP. 1/2" 112" _ 12 12 �1 i 1 1 1 20 '' 3 4 i 20 E X S T! G D W EXHAUST FAN x 05 xx 20 5 _ 6 20 1 1 12 1/2" REST RM RECP. xx 0.5 10 1 PREP AREA RECP xx 112" 12 1 20 7 8 20 1 1 12 112" SALAD BAR PWR. xx 0.8 05 EQUIP RECP xx 1/2" 11 1 - 20 9 10 20 1 1 12 112" DESSERT BAR PWR xx 0.6 0.5 EQUIP. RECP xx 112" 12 1 1 7F20 11 12 20 1 1 12 112" ICE CREAM BAR PWR xx 0 4 0 68 TV PWR/CONY. RECP. xx 1/2" 12 11 - 1 20 13 14 20 1 112 1/2" RECIRC. FOUNTAIN PWR xx 0.5 0 5 ANSUL SYSTEM x 112" 12 1 1 1 20 15 16 1 20 1 1 12 1/2" CONV. RECP xx 0.54 2 0 HOT FOOD COUNTER PWR. xx 3/4" 10 2 25 17 18 1 20 1 12 1 1/2" REST RM RECP. xx 0.5 2 0 1.S S S S 19 20 1 20 1 12 1/2" HOSTESS STATION PWR xx 0.4 2 0 HOT FOOD COUNTER PWR. xx 3/4" 10 2 25 11 22 1 S 1 12 1/2" HOSTESS STATION PWR xx 0.4 2.0 1.S S S S 23 24 1 20 1 12 1/2" WINE CABINET PWR xx 0.4 2.5 ICE CREAM MACHINE x EXISTING 2 30 25 26 20 E X STI G GAS WATER HEATER x 0.2 2.5 S S S S 27 28 20 1 2 EXISTING COOFFEE MACHINE x 1.0 0.8 WAITRESS STATION RECP. xx EXISTING 2 20 29 30 S S S S 08 WAITRESS STATION RECP. xx S S S S 31 32 30 2 EXISTING SPARE xx - 10 1 1 REF, x E I S T I N G 20 33 34 S S S S SPARE xx _ 10 REF. x E I S I N G 20 35 36 20 E X I S T I G TEA MACHINE x 1 1•0 3.5 LARGE ICE MACHINE x EXIS T!NG 2 40 37 38 1 20 E X 9S T I rJ G TEA MACHINE x 1.0 3 5 S S I S S 39 40 20 E X S T I rJ G COOKING LINE REF. x 1.0 REMARKS 1. EXISTING PANEL, KVA OA 14.88 KVA OB 1544 KVA OC 111 2. ALL BREAKERS AND CIRCUITS THAT DO NOT PERTAIN TO ANYTHING THAT IS 'EXISTING -TO -REMAIN' SHALL BE REMOVED. 3. REROUTE EXISTING CIRCUITS, WHICH ARE TO REMAIN, TO NEW PANELS AT Ia 124.0 AMPS lb 128.7 AMPS Ic 92.5 AMPS THE NEW PANEL LOCATION. 4. TAG EXISTING BRANCH CIRCUITS. 5 x EXISTING; VERIFY IN FIELD. FEEDER SIZE 6. xx NEW CIRCUITS; EXISTING BREAKER MAY REMAIN IF IN LIKE -NEW CONDITION. EXISTING CONDUIT SIZE EXISTING _ MOUNT SURFACE MIN. A.I C 22,000 AMPS EXISTING FEEDERS FLOOR DUPLEX MOUNTING DETAIL NOT TO SCALE If SUBJECT TO FIELD INSPECTION" MFG. EXISTING TYPE EXISTING PANEL RATING EXISTING 400 AMPS VOLTS 120/208V 304W PANEL "D" EXISTING POS 42 BUS KVA I LOAD COND. EXISTING S S EXI S S EXISTING S S EXISTING S S EXISTING S WIRE SIZE S S ING S S S S S S S POLE 3 S S 3 S S 3 S S 3 S S 3 S AMPS 70 S S 70 S S 20 S S 20 S S 45 S CKT. 1 3 5 7 9 11 13 15 17 19 21 23 25 27 BUS CKT. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 AMPS 70 S S 70 S S 20 S. S 20 S S 60 S POLE 3 S S 3 S S 3 S S 3 S S 3 S WIRE SIZE EXISTING S S EXISTING S S EXISTING S S EXISTING S S EXISTING S COND. S S S S S S S S S LOAD BUS KVA A 4.5 4.5 2.0 2.0 - B 4.5 4.5 2.0 2.0 - C 4.5 4.5 2.0 2.0 RTU-1 x RTU-2 x KEF-1A x KEF-1B x SPARE SPARE RTU-3 x RTU-4 x " " KSF-1A x KSF-1B x WALK IN COOLER PANEL x " ~ A 4.5 4.5 1.0 1.0 - B 4.5 4.5 1.0 1.0 C 4.5 4.5 1.0 1.0 - SPARE S S S S 29 30 S S S S 2.0 - 2•0 2.0 NEW HOOD EXHAUST FAN xx SPACE " 3/4" S S - 10 S S - 3 S S - 20 S S - 31 33 35 37 32 34 36 38 20 S I S 20 3 S S E X 12 S S I S T 1 1/2" S S G NEW HOOD SUPPLY FAN xx " ROOF RECP. x 1.0 0.54 10 1.0 - - - - - 39 40 20 E X I S T I G DISHWASHER x 3.0 - - - - - 41 42 S S S S 3.0 REMARKS: 1. EXISTING PANEL KVA 14_ 33 34 KVA 08 358 KVA 0C 358 2. ALL BREAKERS AND CIRCUITS THAT DO NOT PERTAIN TO ANY TWINS T!-!AT i5 'EXISTING-TO-REMA N I ' SHALL LL BE REMOVED ED I� 3 REROUTE tYlST INGCIRCUITS, WHICH „RF 0 - MAN 0 AT2711 A�.oc !b 2Q?.3 AMPS Ic 298.3 .AMPS THE NEW PANEL LOCATION - --- - - - --- --------- - ---- t, TAG EXiS. ING nRANCH CIRCUITS � 1•� , 6 NEW CiRCU!TS, EXIgT'NG 3REAriER MAY ic! : I ; ;F :N, '-::;� -'�C : ; 1iJ ,.., CONDUIT SlzEXISTING i -� NOUN SUR;�AC- M'N A1,: EXISTING EXISTING FEEDERS FEEDERS EXISTING W,W, ELECTRICAL. RENOVATION NOTES: 1. ELECTRICAL CONTRACTOR SHALL MAKE A THOROUGH SURVEY OF EXISTING ELECTRICAL SYSTEM AND FAMILIARIZE HIMSELF WITH IT, AND WITH THE NEW ELECTRICAL SYSTEM PROPOSED, PRIOR TO INSTALLATION. 2 ALL EQUIPMENT SCHEDULED TO BE REUSED, SHALL BE RECONDITIONED TO LIKE NEW IF COST TO REPAIR OR RECONDITION EXCEEDS NEW COST, THEN THE EQUIPMENT SHALL BE REPLACED. 3. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECONNECTING ALL ELECTRICAL EQUIPMENT !N ORDER TO HAVE A COMPLETE WORKING JOB WHETHER OR NOT THE EQUIPMENT IS SHOWN ON NEW ELECTRICAL PLANS. 4, DUE TO THE NATURE OF THIS PROJECT, THE ELECTRICAL CONTRACTOR MUST CHECK OUT ALL EXISTING CIRCUITS STARTING AT THEIR DISTRIBUTION POINT IN ORDER TO SEE IF THEY ARE STILL ALIVE. 5. WHEN INSTALLING NEW EQUIPMENT, THE ELECTRICAL CONTRACTOR SHOULD USE EXISTING CONDUITS AND AVAILABLE CIRCUITS IF POSSIBLE. ALL REUSED CIRCUIT BREAKERS, OUTLETS, SWITCHES, ETC., SHALL BE INSPECTED AND REPLACED AS NEEDED. 6. TAG EXISTING BRANCH CIRCUITS AND ONLY REUSE THOSE THAT ARE IN LIKE -NEW CONDITION AND COINCIDE WITH THE PLANS. 7. SPACES HAVE BEEN LEFT IN PANEL, IF BRANCH CIRCUITS HAVE BEEN MISSED. ALL ELECTRICAL EQUIPMENT REMOVED SHALL BE KEPT IN A SECURE AREA UNTIL OWNERS DECIDE WHAT TO DO WITH IT. B. THE ELECTRICAL CONTRACTOR SHALL NOT OVERLOAD ANY EXISTING PANEL BOARDS OR FEEDERS, AND NOT TO EXCEED 80% OF THEIR RATED VALUE. 9. ELECTRICAL CONTRACTOR SHALL VERIFY ALL ELECTRICAL REQUIREMENTS FOR ALL EXISTING EQUIPMENT TO REMAIN PRIOR TO CONSTRUCTION. 10. SPACES HAVE BEEN LEFT IN NEW PANEL BOARD SO THAT EQUIPMENT OR CIRCUITS MISSED MAY BE CONNECTED. 11. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY PROBLEMS DURING CONSTRUCTION BEFORE PROCEEDING WITH THE PROJECT. 12. TOTAL ELECTRICAL SYSTEM TO BE INSPECTED BY ELECTRICAL CONTRACTOR AND BROUGHT UP TO CODE. 13 THE INTENT OF THE ELECTRICAL DESIGN IS TO UTILIZE AS MUCH OF THE ELECTRICAL EQUIPMENT AS POSSIBLE, THEREBY ELIMINATING EXCESSIVE COST, CONSTRUCTION, AND TIME. EXISTING WEATHER HEADS EA 120/208V 304W EXISTING WIRE WAY EXISTING EXISTING FEEDERS FEEDERS EXISTING EXISTING 400 AMP O 400 AMP 120/208V 120/208V 304W EXISTING 304W METER EXISTING EXISTING W,W ,,SUBJECT TO FIELD INSPECTION " EXTERIOR INTERIOR I I EXISTING FEEDERS 5US3Jb �r`1St�G�ION EXISTING PANEL SUBJECT ' I U"FCURi6A BUILD) - CODE PLUS LOCAq A AENDMENTS BY: I IkH EXISTING FEEDERS a" EXISTING PANEL EXISTING FEEDERS FEEDERS I GRADE EXISTING POWER RISER N.T.S. 1. DO NOT SCALE THE ELECTRICAL DRAWING. REFER TO THE ARCHITECTURAL PLAN AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT AND CONFIRM WITH OWNERS REPRESENTATIVES. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITIONS OF THE NATIONAL ELECTRICAL CODE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES. 3. UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER, WITH "THHN" INSULATION FOR SIZE #10 AND SMALLER. CONDUCTORS LARGER THAN #10 SHALL HAVE "THWN" INSULATION. ALL CONDUCTORS #10 AND SMALLER MAY BE SOLID. ALL CONDUCTORS #8 AND LARGER SHALL BE STRANDED. 4. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. 5. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK MAKE, QUICK BREAK, WITH ENCLOSURES AS REQUIRED BY EXPOSURE. 6. THESE PLANS DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION, THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND MEET ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 7. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED IN ARTICLE 250. NATIONAL ELECTRICAL CODE. B. ALL MATERIALS SHALL BE NEW AND SHALL BEAR U.L. LABELS WHERE APPLICABLE. 9 a' r c ALL WORK SHA LL LL BE PERFORMED M E OR ED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST LASS WORKMANSHT MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE AND tirCCPTANCE BY ENGINEER/ARCHITECT MUST BE A CONDIT!ON OF THE SUBCj^jNTRACTOR 'v -nE ELECTRICAL -N`TALLATION SHALL MEET ALL STANDARD REUL:!REMENTS CF pOl1ER, i 1jEiT t 'i IPANY AND TELEPHONE CCMPANY 11. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZE THE CONTRACTOR SHALL PROVIDE CIRCUITS TO SUIT LOB CONDITIONS. 12 SEC NOTES ON PLANS FOR OTHER REQUIRCM;.N i S. i3. FURNISH AND INSTALL LIGHTING FIXTURES AND LAMPS AS CALLED FOR ON PLANS, OR AS SELECTED BY OWNER 14 ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVO!D INTERFERENCE WITH THE PROCESS OF CONSTRUCTION 15. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY PHASE OF THE INSTALL ATION WHICH MAY BE DAMAGED. 16. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK 17. CHECK ALL EQUIPMENT FOR PROPER VOLTAGE, PHASE, AND CURRENT BEFORE CONNECTION TO CIRCUITS. 18. ELECTRICAL CONTRACTOR SHALL CHECK AND VERIFY EQUIPMENT FURNISHED AGAINST THOSE SPECIFIED OR INTENDED AND REVISE BRANCH CIRCUITS AS MAY BE REQUIRED WITH PRIOR APPROVAL OF ENGINEER/ARCHITECT. AIR CONDITIONING EQUIPMENT AND CONTROLS SPECIFICATION 1. ELECTRICAL CONTRACTOR SHALL INSTALL ALL CONTROL RACEWAY (CONDUIT), WIRE INSTALLATION, CONNECTIONS ETC. IN ACCORDANCE WITH WIRING DIAGRAMS ON AIR EQUIPMENT. 2. A/C / ELECTRICAL PLANS OR DIAGRAMS FURNISHED BY MANUFACTURER OF THE EQUIPMENT 3. ALL POWER WIRING FOR THE AIR CONDITIONING EQUIPMENT SHALL BE FURNISHED, INSTALLED AND CONNECTED UNDER THIS SECTION OF THE SPECIFICATION. 4. MECHANICAL CONTRACTOR SHALL PROVIDE MOTOR STARTERS FOR ALL AIR CONDITIONING EQUIPMENT. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONECTIONS TO AIR CONDITIONING EQUIPMENT PER MANUFACTURERS SPECIFICATIONS. 5. AIR CONDITIONING EQUIPMENT INCLUDES CONDENSOR, COMPRESSOR AND FAN, FAN COIL UNITS, ELECTRICAL STRIP HEATER, THERMOSTAT, ETC. ELECTRICAL SPECIFICATIONS P. di I FLAII ULVIATION (C" MUST 3E ;aJ A Uj L) JLEOR? INSPEC T IC�j REQU`aT NOTES: 1. CONTRACTOR TO VERIFY ALL KITCHEN ELECTRICAL REQUIREMENTS PRIOR TO BID/ CONSTRUCTION 2. VERIFY ALL EXISTING CONDITIONS IN FIELD PRiOR TO ANY CONSTRUCTION. E U +' N 0 0) 60 00 0 � M U) 0 M tJ d �t (a avi ` La_ M M U Li O ((00 to E (n CC M ~LL_ 3 0 m a� v'c cN vv `a o Q rk:'r ��Y.r,F 1 i Z. - d Ll_ f �iarce!!c.F' Pn�t}JzG 62! . t , ! ! (D -4-J W (D M x O •E. / T D .0 E_ O 7 O �i 0 >-I'- IN 0 N-) W U 0 o N fn v i U a � o Z ow>rLGrG Z norevision date Phase: PERMIT SET: 11 /30/ 5 issued for permit NOTE: ANY DESIGN CHANGES, TO THE SYSTEM COVERED BY THESE PLANS WITHOUT PRIOR APPROVAL OF THE ENGINEER WHO PREPARED THESE PLANS, WILL NULL AND VOID THESE PLANS AND THE REVISED INSTALLATION. IN ADDITION, ALL EXPENSES ASSOCIATED WITH RETURNING THE SYSTEM TO ITS ORIGINAL DESIGN WILL BE THE RESPONSIBILITY OF f HE COMPANY WHICH APPROVED THESE CHANGES. I III FORMICA iASSOCIATESinc. ii, Consulting Engineers 3100 N.W. Boca Raton Blvd. Sub #117 Boca Raton, FI 33431 TEL (561) 368-3611 FAX: (561) 368.4733 Certl IUM Id00008818 Robert F. Foffrka, P.E. Lk:wm #19733 E-md: iori'deacfocrrliceeclpk!! oft.com Sheet: electrical panels, data, risers, & specs Scale: as noted P4 25373 Drown: CPG/KEB Chk: RFF E3.M Sheet 3 of 3 ►pyright Q M Architectus, Incorporated I rights reserved