06-774-006GENERAL 5TRUCTURAL NOTES: 1. ALLOWABLE SOIL BEARING CAPACITY: EXISTING SOIL CONDITION HAS BEEN OBSERVED IN SHALLOW Pit. NO SOIL BORING TESTS AIRE AVAILABLE. FOUNDATIONS ARE DESIGNED FOR AN ASSUMED SAFE SOIL BEARING CAPACITY OF 2000 NSF, BASED ON OBSERVED SAND AND FRAGMENTED ROCK SUBSOIL. SHOULD ACTUAL CONDITIONS BE FOUND TO DIFFER THROUGHOUT CONTRACTOR SHALL NOTIFY ARCHITECT PRIOR TO PROCEEDING WITH COMPACTION. PRIOR TO POURING, CONTRACTOR SHALL PROCURE 4 SUBMIT TO THE COUNTY A STATEMENT FROM THIS ARCHITECT OR A P.E. ATTESTING TO ACTUAL SOIL CONDITIONS FOUND. 2. CONCRETE: I. ALL CONCRETE WORK SHALL CONFOIRM TO ALL REQUIREMENTS OF ACI 301 -96 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS ". 2. ALL CONCRETE SHALL ATTAIN 3000 PS -I MINIMUM COMPRESSIVE STRENGTH AT 18 DAYS. 3. MIX DESIGNS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO COMMENCEMENT OF ANY CONCRETE WORK 4. NO WATER SHALL BE ADDED TO THE CONCRETE AT THE JOB SITE. 5. TRANSPORTING, PLACING, CURING AND DEPOSITING OF CONCRETE SHALL COMPLY WITH ACI- 301 -96. 3. CONCRETE COVER: TO BE AS FOLLOWS: BOTTOM TOP SIDES FOOTINGS 3" 2" 3" BEAMS 11/2° 11/2" IV211 COLUMNS - -- - -- 11/2" SLABS 3/ " 3/4" 11'2 n 2ND FLOOR EXTERIOR SLAB 1" 11/211 11/2" GROUND FLOOR SLAB 3" 1 " 3" 4. REINFORCING STEEL: t0 BE NEW HIGH STRENGTH BILLET STEEL DEFOI41ED AS PER ASTM A -305 AND CONFORRMING TO ASTM A -6151 GRADE 60. LAP CONTINUOUS BARS 36 -BARS DIAMETERS. HOOK DISCONTINUOUS ENDS OF ALL TOP BARS. ALL REINFORC- ING STEEL TO BE DETAILED AND FABRICATED IN ACCORDANCE WITH "MANUAL OF STANDARD PRACTICE OF DETAILING REINFORCED CONCRETE STRUCTURES" AND THE ACI BUILDING CODE 318 -95. SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. D. MASONRY WALLS: MASONRY WALLS SHALL BE REINFORCED WITH' 5 BARS IN GROUTED CELLS SPACED AT 48 INCHES CENTER TO CENTER LAP 48 BAR VIA, MASONRY UNITS SHALL BE TWO CELLS HOLLOW UNITS CONFORMING TO ASTM C -90 WITH A COMPRESIVE STRENGTH OF 1500 PSI ON THE NET CROSS SECTIONAL AREA AND SHALL BE PROVIDED AT EACH SIDE OF ALL MASONRY OPENINGS. VERTICAL CELLS TO BE GROUTED SHALL HAVE A MINIMUM CLEAR DIMENSION OF 3 INCHES AND CLEAR AREA OF 10 SQ IN. GROUTING SHALL BE DONE N A CONTINUOUS OPERATION IN LIFTS NOT EXCEEDING FOUR (4) FT. WITH A MAXIMUM TOTAL POUR OF TEN (10) FT. THE GROUTING SHALL BE CONSO- LIDATED BETWEEN LIFTS BY PUDDLING, RODFNG, OR MECHANICAL VIBRATION. PROVIDE '9 GAUGE LADDER TYPE OUR -O -WALL HORIZONTAL JOINT REINFOR- CING AT 16 INCHES O.C. 6. PRESSURE TREATED LUMBER / LUMBER ALL LUMBER SHALL BE GIVEN A PRESERVATIVE TREATMENT IN ACCORDANCE WITH FEDERAL SPECIFICATION TT -W -571. THE PRESERVATIVE USED AND THE METHOD AND RESULT OF TREATMENT SHALL BE SUITABLE FOR THE SPECIES OF WOOD SPECIFIED AND EXPOSURE CONDITIONS ANTICIPATED. ALL LUMBER SHALL BE SOUTHERN PINE No. 2 OR BETTER W/ MIN. FLEXURAL ALLOWABLE STRESS Fb■ 1000 PSI MIN, SHEAR STRESS Fv ■90 PSI, MIN. MODULES OF ELASTICITY E• 1,600fflW PSI. 1. DESIGN LOADS: A THE DESIGN COMPLIES WITH THE REQUIREMENTS OF THE FLA BLDG. CODE 2004 AND OTHER REFERENCED CODES AND SPECIFICATIONS. ALL REFERENCED CODES SHALL BE LATEST EDITION AT THE TIME OF PERMIT. B. WIND LOAD CRITERIAt BASIC LOAD VELOCITY - 146 MPH ASCE 1 -98 LIVE LOADS: DEAD LOADS: ROOF 30 PSF ROOF 25 IS F FLOOR AT TERRACE 100 PSF FLO R AT TERRACE 25 PSF 8. FORM WORK AND SHORING : FORMS AND SHORES FOR CONCRETE SLAB AND BEAM SHALL BE DESIGNED TO WITHSTAND THE DEAD LOAD OF CONCRETE AND ALL CONSTRUCTION LOADS. DESIGN AND CONSTRUCTION OF FORE1 WORK AND SHORING SHALL COMPLY WITH THE AC.I.318 -99 BUILDING CODE AND BE ENTIRELY THE RESPONSIBILITY OF THE GENERAL CONTRACTOR SHORING DRAWING TO BE PROVIDED BY THE GENERAL CONTRACTOR AND SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA S. SAFETY : A THE CONTRACTOR SHALL COMPLY WITH THE SAFETY REQUIREMENTS OF ALL LOCAL, STATE AND FEDERAL LAWS. B. PROVIDE ALL SHORING, BRACING AND SHEETING AS REQUIRED FOR SAFETY AND FOR THE PROPER EXECUTION OF THE WORK, REMOVE WHEN THE WORK IS COMPLETED. 10. GENERAL: STRUCTURAL DRAWINGS SHALL BE WORKED TOGETHER WITH ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS TO LOCATE DEPRESSED SLABS, SLOPES, OPENINGS AND DIMENSIONS, ETC. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE BEFORE STARTING WORK CONTRACTOR IS RESPONSIBLE FOR ALL SHORING AND RE- SHORING REQUIRED. 11. SOIL SHALL BE TREATED FOR TERMITES PROTECTION AS PER CHAPTER 104 OF FBC. 2004 EDITION. 12. PLANS 4 CALCULATIONS HAVE BEEN DESIGNED IN COMPLIANCE WITH FBC. 1004 EDITION. a p ' a ' O • N m a 3/8" METAL PLATE (2) 3 "x 12" CYPRESS BEAM 1211 dp .• a ° 2 "x 12" CONC. MASONRY BLOCK (SEE NOTES FOR TYPE "All REIRFa SECTION 1/ A -3 SCALE: 3/4 " =I' -0" .. A -5 COLUMN SIZE, mINF'G, 4 CONC. STRENGTH AS NOTED IN COLUMN SCHEDULE �LUMNDE - fIlLf E TYPICAL STD. 90' HOOK nTll .p a, ell TYPICAL CONCRETE_ BLOCK COLUMN DETAIL rA--" SCALE: 3/4 " =I' -m" � A -5 TOP OF ROOF NOTES: I- ALL PRE- FABRICATED ROOF TRUSSES SHALL BE SPACED * 24" O.C. AND SHALL BE DESIGNED AND FABRICATED N ACCORDANCE W/ THE FLORIDA BLDG. CODE, 2004 EDDITION LOCAL CITY CODE, THE TRUSS PLATE INSTITUTE AND ARCHITECTURAL / STRUCTURAL DRAWINGS SUBMIT SHOP DWG's SIGNED 4 SEALED BY A P.E. PRIOR TO FABRICATION. TRUSS SHALL BE DESIGNED AS A COMPONENT 4 CLADDINGS. 2- PLYWOOD SHEATHING TO BE " COX NAILED AS PER ROOF FRAMING PLAN. 3- DESIGN LOADS: ROOF: LL : 30 MF OL :25 PSF NET UP LIFT: SEE PLAN ( 41 MF INTERIOR) ROOFING NOTES: •25 YEAR ARCHITECTURAL PROFILE ASPHALT COMPOSITION SHINGLES OVER 94' FELTS HOTMOPPED OVER 300 ASTM FELTS TINTAGGED TO 5/8" CDX PLYWOOD SHEATHING NAILED TO ROOF TRUSSES W/ 10D NAILS SPACED b "ON FIELD AND 4" ON EDGE BANDS. • ALL ROOFING SYSTEMS MUST COMPLY W/ CURRENT PRODUCT CONTROL APPROVAL. • CONTRACTOR MUST SUBMIT SYSTEM AND COMPLETE NOTICE OF APPROVAL TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. FOUNDATION NOT Q 1.- TOP OF FLOOR ELEVATION +/- 0- 01Y2.45" NjYD. G 0-0" FF. ELEV. DENOTES MIN -a A I HC L DOCUMENTS FOR MIR ELEVATION REQ. ABOVE MEAN SEA LEVEL. 2: 12" X 12 CONCRETE MASONRY COLUMNS WILL BE FILLED W/ 3000 p.e.I. GROUT AND REINFORCED AS SHOIIIiv ON SHEET A -5. 3.- ALL DIMENSIONS HAVE TO MATCH W/ ARCH. DIMENSIONS. 4: SOIL SHALL BE TRATED FOR TERMITED PROTECTION AS PER CHAPTER 104 OF F.B.C. 2004 EDITION. 5: SOIL SHALL BE COMPACTERD •TO %% OF MODIFIED PROCTOR FOOTING SCHEDULE MARK SIZE REINFORCEMENT REMARKS WF -Ib 16" x 12" 2 5 CONT BOTT. 04 * 24" TRANSV BOTT. WF -24 24" x 12" 3 5 CONT BOTT. 04 * 24" TRANSV. BOTT. ® 3' -0" X V -0" X 16" 4 5 EACH WAY BOTT. 4 TOP — _— _— _— _— ® 4' -0" X 4' -0" X 16" 5'5 EACH WAY BOTT. 4 TOP I I I I I I � I I I I I COLUMN SCHEDULE MARK SIZE REINFORCING TYPE REMARKS VERTICAL TIES IQ 12 "x12" 4% 03 *8" A ATTIC VENT I L AT I ON: ROOF AREA= 1 050 SF 1 050 SF / 150 =1 SF 1 SF: 0b1 OF (4 "X24" VENT)= II VENT. MIN. ROOF PLAN SCALE 1/47 - 1' -OA 04 *16" OC. 4 10" DRILL INTO EXISTING FOOTING W/ 14ILTI EPDXY. WF -I6 _ ----- I- r—------ ILF- 24 - - - - -- -rte ----------- -- i I I I I I I I I I I I I I I II I I I I I I I I I I I I II III I I I I I I I I I I II I I I I I I I I I II L_ - — _— _— _— _— I I I I I I I I I II I I I I I I � I I I I I I I I I I II I NII I I I I I --- _i j I _ I I WF -14 I I II I -� - - -� >�-------- - - - - -- L = -� ------------- r 12" REINF. MASONRY BLOCK WALLS FILLED W/ 3000 P.S.I. GROUT AND REINF. W/ 1 "5 * 48" O.C. MAX. (3) * EVERY COMER 4 '9 GAUGE LADDER TYPE EVERY 16" O.C. IN ALL WALLS. FOUNDATION, PLAN SCALE 1/4* =1' -Ow �I —J p I, I` L -1 J — J 1 f 9 E - .�S7EitFQ,.1 - REVISIONS BY BLDG. DEP. COMMENT FRC. 1 101 OIL m ■1 (00 Wm� 0 3o ` V) Fa n V) 0 l0 Q as 0 CID Z2 .j c U� O Q � W Lu < C� p ,s O Z �� z => DRAWN O.B. f - 1---------- - - - - -- L = I ®I -t------------------- i - -1- --A - --------------}--- L_ - — _— _— _— _— _— _ —_ - - -_ ------------- - L------------ - - - - -� - - - - -- j - I------------- I - - - - -� I --- _i -� --------------{--- I I - -------------- I -� - - -� >�-------- - - - - -- L = -� ------------- r 12" REINF. MASONRY BLOCK WALLS FILLED W/ 3000 P.S.I. GROUT AND REINF. W/ 1 "5 * 48" O.C. MAX. (3) * EVERY COMER 4 '9 GAUGE LADDER TYPE EVERY 16" O.C. IN ALL WALLS. FOUNDATION, PLAN SCALE 1/4* =1' -Ow �I —J p I, I` L -1 J — J 1 f 9 E - .�S7EitFQ,.1 - REVISIONS BY BLDG. DEP. COMMENT FRC. 1 101 OIL m ■1 (00 Wm� 0 3o ` V) Fa n V) 0 l0 Q as 0 CID Z2 .j c U� O Q � W Lu < C� p ,s O Z �� z => DRAWN O.B. ctRecRl® FRC. DAm 09 -09 -05 scan AS SHOWN. J09 in - IR1H w ra cr SHE