09-629-002:r
E DIALYSIS' - 2`007 FLON-ftlu"A BUILr%lNjft 0"DE
K 1
M 'U"NSPRINKLERED"'
JURISDICTION
Miami & Dade County Construction Cade Enforcement
LIFE SAFETY + CODE REVIEW
REV. NO.
State of Florida Division of Fire Prevention
DESCRIPTION
2007 Florida Plumbing Code, Dade County Edition
2007 Florida Fuel Gas Code, Dade County Edition
2007 Florida Mechanical Code, Dade County Edition
2007 Florida Electrical Code, Dade County Edition
2007 Florida Fire Prevention Code, Dade County Edition
2007 Florida Building Code - Accessibility
OCCUPANCY
Business Group B
Section 304
CLASSIFICATION
OCCUPANTLOAD
Business Area 100 gross
988 Occupants
Table 1004.1.1
EXITS
Maximum Dead End
200-01"
Section 1017.3
Corridor
Minimum Clear Door
32"
Table 1008.1.1
Width
MINIMUM CORRIDOR
148(Occupants /floor) x .15 = 29.41" / 2 (Exits) = 14.71"
Section 1005.1 / 1017.2
WIDTH
(56" provided) / (44" minimum width required)
INTERIOR FINISHES
Class A - Vertical Exits and Exit Passageways, Class B - Corridors
Table 803.5
TOILET ACCESSABILITY
1 Accessible Unisex Toilet Room per Floor (1 provided)
11 -4.5.1 (2)(e)
REQUIRED RATINGS
Corridors
1 Hour
Table 1017.1
Doors accessing 1 hour
20 min
Table 715.4
corridor
Vertical exit closures
2 Hour
Section 1020.1
(buildings over 4 stories
tall)
Door in vertical exit
90 min
Table 1017.1
closure - 2 hour rated wall
Tenant Seperation
No Separation Required
Section 708.1 (Exception 1)
HANDICAP ELEMENTS
Hardware
Lever handles throughout with knurled surfaces to hazard areas
Signage
As Required
Fire Alarm
Required
Section 907.2.2
Emergency Lighting
Required
Section 1006
Fire Extinguishers
Required
NFPA 10
Height Above Finished Floor - Top of Extinguisher 60" AFF Max
Section 6.1.3.8
9
ral
LO
N
66
LO
a Fill!
1A .ii'
0
�`
:b
ii i s I 40 4 �� askew, III
\v wea
Architecture 1500 Union Avenue
Planning Memphis, TN 3€3101
Interior Design Tel. 901 - 278 -6868
www.clnfa.COff1
G000 COVER SHEET
G101 GENERAL SPECIFICATIONS
G201 LIFE SAFETY PLANS
G202 LIFE SAFETY PLANS
A101 FIRST, SECOND & THIRD FLOOR DEMOLITION PLANS
A102 FOURTH, FIFTH & SEVENTH FLOOR DEMOLITION PLANS
A201 FIRST, SECOND & THIRD FLOOR FINISH FLOOR PLANS
A202 FOURTH, FIFTH & SEVENTH FLOOR FINISH FLOOR PLANS
A211 FIRST, SECOND & "THIRD REFLECTED CEILING PLANS
A212 FOURTH, FIFTH & SEVENTH FLOOR REFLECTED CEILING P
A501 ENLARGED PLANS AND INTERIOR ELEVATIONS
A601 SCHEDULES & DETAILS
E001 ELECTRICAL LEGEND & SCHEDULE
E100 FIRST, SECOND & THIRD FLOOR LIGHTING PLANS
E101 FOURTH, FIFTH & SEVENTH FLOOR LIGHTING PLANS
E200 ELECTRICAL SPECIFICATIONS
1 OF 10 1 ST FLOOR - FIRE ALARM PLAN
2 OF 10 2ND FLOOR - FIRE ALARM PLAN
3 OF 10 3RD FLOOR - FIRE ALARM PLAN
4 OF 10 4TH FLOOR - FIRE ALARM PLAN
5 OF 10 5TH FLOOR - FIRE ALARM PLAN
6 OF 10 6TH FLOOR - FIRE ALARM PLAN
7 OF 10 7TH FLOOR - FIRE ALARM PLAN
8 OF 10 ROOF FIRE ALARM PLAN & BATTERY SCHEDULE
9 OF 10 CALCULATIONS - FIRE ALARM PLAN
'10 OF 10 RISER , FIRE ALARM PLAN
Grand total; 26
1
1 11/06/2009
LIFE SAFETY + CODE REVIEW
REV. NO.
I DATE
DESCRIPTION
Ulm
PROJECT STATUS - - - -
CONSTRUCTION OWIVI NT
PROJECT NAME
ONE 7000 PLACE
7000 SW 02 AVE.
MIAMI, FL 33143 -
COVER SHEET
DRAWN CHECKED PROJECT NUMBER
JLD JPW 08048
DATE SHEET NO.
07 -08 -2009 GOOO
0 2009 ASKEW NIXON FERGUSON ARCHITECTS INC.
I` • •