Loading...
08-668-001SYMBOLLEGEND-, SYM. DESCRIPTION MODEL MANUFACTURER El FIRE ALARM CONTROL PANEL CP -35 SIEMENS PwR AUDIBLE POWER PANEL PAD -2 SIEMENS ANN REMOTE ANNUNCIATOR PANEL LED -3/4 SIEMENS �c FIRE ALARM TERMINAL CABINET F.B.O. SIEMENS B PHOTOELECTRIC DETECTOR W/ DB -11 & DB -11 SEAL PE -11 SIEMENS e R PHOTOELECTRIC DETECTOR W/ DB -11 & RR -11 RELAY PE -11 SIEMENS lD CEILING THERMAL DETECTOR DT -11 SIEMENS LD MANUAL PULL STATION MS -151 SIEMENS -I ELEVATOR WARNING LIGHT SSU620 SIEMENS N TAMPER SWITCH (BY OTHERS) F.B.O. F.B.O. 2 FLOW SWITCH (BY OTHERS) F.B.O. F.B.O. FPL POST INDICATOR VALVE F.B.O. F.B.O. aP BACK FLOW PREVENTER F.B.O. F.B.O. FPL HORN U -MHST SIEMENS FLOW BELL 435 -6G1 EST L -C, A Lm MIAMI MEDI BUILD,ING FIRE ALARM NOTES - SYSTEM 3 SYSTEM 1, ALL WIRING MUST CONFORM WITH NEC ARTICLE 760 AND LOCAL CODES. ALL EQUIPMENT SHALL BE UL LISTED. ALL DEVICES SHALL BE COMPATIBLE WITH THE CONTROL PANELS. SYSTEM IS POWER LIMITED PER NEC 760 AND UL 864 ,REQUIREMENTS. 2. ALL INITIATING AND INDICATING CIRCUITS MUST BE SUPERVISED. 3. CIRCUIT POLARITY MUST BE OBSERVED. 4. WIRE RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION OF ALL EQUIPMENT TO BE DETERMINED IN THE FIELD, BUT SHALL CONFORM WITH THE BASIC LAYOUT ASIiSHOWN ON DRAWINGS TO PREVENT CIRCUIT OVERLOAD. 5. MINIMUM CONDUIT SIZE WILL IBE 3/4 ". CONDUIT SHALL BE NO MORE THAN 40% FILLED PER NEC �IREQUIREMENTS. 6. POWER UP &POWER DOWN ON PANEL MUST BE DONE IN PROPER SEQUENCE. POWER DOWN A - DISCONNECT BATTERY. B -TURN OFF AC POWER PRIMARY &SECONDARY. POWER UP I A -TURN ON AC POWER PRIMARY &SECONDARY. B - RECONNECT BATTERIES. I 7. THE FIRE ALARM CONTROL PANEL SHALL NOT BE USED TO POWER ANY UNAUTHORIZED EXTERNAL DEVICE. 8. SIEMENS, 6BERUS DIVISION IS RESPONSIBLE FOR FIRE ALARM EQUIPMENT ONLY. ALL OTHER EQUIPMENT SHOWN ARE FOR DIAGRAMMATICAL PURPOSES. 9. DAMPER MOTOR AND FAN SHUTDOWN CONNECTIONS (IF ANY) ARE TO BE COORDINATED IN FIELD WITH'HVAC CONTRACTOR. 10. FIRE ALARM POWER SUPPLIES AND ALL REMOTE SUPPLIES MUST BE CONNECTED TO BUILDING OR COLD -WATER GROUND VIA 1 GREEN #10 THNN OR EQUIV. ii. ALL SURGE /TRANSIENT SUPRESSORS MUST BE CONNECTED TO BUILDING OR COLD -WATER GROUND. 12. FIRE ALARM INITIATING DEVICES SHALL NOT BE INSTALLED UNTIL CLEANUP OF ALL TRADES ARE COMPLETE. FAILURE TO COMPLY WITH THIS NOTE WILL VOID ALL WARRANTIES. 13. EVACUATION SIGNALS SHALL BE TEMPORAL IN ACCORDANCE WITH NFPA 72 3 -7.2 (A) AND ANSI 53.41. 14. VERIFY ALL MOUNTING HEIGHTS WITH AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. 15. UNDERGROUND WIRING IS ACCEPTABLE PROVIDED N.E.C. REQUIREMENTS FOR UNDERGROUND AND POWER LIMITED WIRING ARE MET. BUILDING DESCRIPTION THIS IS AN EXISTING 5 STORIES OFFICE BUILDING, FULLY SPRINKCLERED. FIRST PAGE SEQUENCE OF OPERATION 1. ACTIVATION OF ANY MANUAL INITIATION DEVICE WITHIN THE SYSTEM SHALL CAUSE THE FOLLOWING ACTIONS AND. INDICATIONS: 1) SOUND THE AUDIBLE CIRCUITS WITH THE EVACUATION TONE AND ACTIVATE THE VISUAL SIGNALS OF THROUGHOUT THE FACILITY. 2) ACTIVATE THE ALARM LIGHT AND SOUNDER AT THE FIRE ALARM CONTROL PANEL. 3) ACTIVATE THE ALARM LIGHT FOR THE ZONE THAT CONNECT$ TO THE DEVICE INITIATING THE EVENT. 2. ACTIVATION OF ANY AUTOMATIC FIRE DETECTION DEVICE WITHIN THE SYSTEM SHALL CAUSE THE FOLLOWING ACTIONS AND INDICATIONS: 1) SOUND THE AUDIBLE CIRCUITS WITH THE EVACUATION TONE AND ACTIVATE THE VISUAL SIGNALS 'OF THROUGHOUT THE FACILITY. 2) ACTIVATE THE ALARM LIGHT AND SOUNDER AT THE FIRE ALARM CONTROL PANEL. - 3) ACTIVATE THE ALARM LIGHT FOR THE ZONE THAT CONNECTS TO THE DEVICE INITIATING THE EVENT. 3. ACTIVATION OF ANY DUCT MOUNTED SMOKE DETECTORS SHALL, ACTIVATE A SUPERVISORY SIGNAL AT THE FACP AND ANNUNCIATORS, CAUSE THE SHUTDOWN OF THE ASSOCIATED AIR HANDLER OR CLOSURE OF THE ASSOCIATED DAMPER. COORDINATE WITH HVAC CONTRACTOR AND CONTRACT DOCUMENTS. 4. ACTIVATION OF ANY SMOKE DETECTORS IN A SINGLE ELEVATOR LOBBY, AN ELEVATOR EQUIPMENT ROOM OR ELEVATOR HOIST WAY SHALL, BESIDES THE ACTIONS DESCRIBED ABOVE, CAUSE THE'-RECALL OR THAT BANK OF ELEVATORS TO THE DESIGNATED LEVEL. 5. ACTIVATION OF THE SMOKE DETECTOR IN THE DESIGNATED LEVEL ELEVATOR LOBBY SHALL, BESIDES THE ACTIONS DESCRIBED ABOVE, CAUSE THE RECALL OF THAT BANK OF ELEVATORS Td THE ALTERNATE RECALL FLOOR. 6. ACTIVATION OF ANY SMOKE DETECTOR IN AN ELEVATOR EQUIPMENT ROOM SHALL, BESIDES THE ACTIONS DESCRIBED ABOVE, CAUSE THE ACTIVATION OF THE ELEVATOR WARNING LIGHTS IN THE MAIN AND ALTERNATE RECALL LOBBIES. 7. ACTIVATION OF ANY FIXED TEMPERATURE HEAT DETECTOR IN AN ELEVATOR HOIST WAY OR MACHINE ROOM SHALL CAUSE THE POWER TO THE ELEVATORS IN THAT BANK A TO SHUNT. DO NOT CONNECT SHUNT TRIP HEAT DETECTORS TO THE BUILDING 4laNkT_lw -c k FIRE ALARM SYSTEM. COORDINATE SHUNT TRIP OPERATION WITH ELEVATOR M CONTRACTOR. c, NQvcpw'fd m, 8. ACTIVATION OF ANY SUPERVISORY DEVICE WITHIN THE SYSTEM SHALL CAUSE THE FOLLOWING ACTIONS AND INDICATIONS: 1) ACTIVATE THE SUPERVISORY LIGHT AND SOUNDER AT THE FIRE ALARM CONTROL PANEL AND ANNUNCIATORS, IF ANY. 2) ACTIVATE THE SUPERVISORY LIGHT FOR THE ZONE THAT CONNECTS TO THE DEVICE INITIATING THE EVENT. 0 9. FLOW BELL OPERATION: A) FLOW BELL SHALL SOUND UPON THE ACTIVATION OF THE FLOW SWITCH ONLY. B) FLOW BELL SHALL SOUND THE ENTIRE TIME OF WATER FLOW. tNSTAUEDN';GC 6_E2D?►NCEWMi C) FLOW BELL SHALL BE INCAPABLE -OF BEING SILENCED FROM FCP. �/_.Ar�t; p7o; ioi- ay1,� Z irk ?,r Iif .4•i`'�, �4r� .6,,,`«AFL �I:� A D a MfA�t4r -•rar: ..�S``•'f �gtt °. f +r t'% t ; f a::uiyF 3T SCOPE OF WORKT�: INSTALLING 1 SMOKE DET. 2 HEAT DET. AND 2 RELAYS AND 1 FLOW BELL. TO THE EXISTING FIRE ALARM PANEL SYSTEM 3. THE SMOKE IS GOING ON THE ELEVATOR TOP OF SHAFT. 1 OF THE HEAT DET. IS GOING TO BE INSTALLED AT THE ELEVATOR MACHINE ROOM. THE OTHER HEAT DET. IS GOING TO BE INSTALLET AT THE ELEVATOR TOP OF SHAFT. THE RELAYS ARE GOING TO BE INSTALLED AT THE PANEL, ONE IS GOING TO BE USED FOR THE SHUNT TRIP AND THE OTHER ONE WILL BE USED FOR ELEVATOR WARNING LIGHT: DAMEL F. GUTIERREZ, PX 9360 CORAL WAY SUM MC. 1049086 wA a FL 33145 DFG PH.•(905)481 -317'8 CONSULTING ENGINEERS INC. �L�SZGN — INSPECTIONS c VI M O �1 M O N O Ln ♦� C X AV L 4 W d C .M_ W u M W LL, o �i iz o ��' 1 WCL CJ Z E0 NW www ab �� Z o 0 N as Ea 8 � U HLLj CL 0 0 LL Ld M H A g� u w z z O w w ll SHEET NO. U of 4 WIRE LEGEND SYM. DESCRIPTION CONNECTIONS - A 2 CONDUCTOR #18 AWG FPL FOR CONNECTION TO CONVENTIONAL DEVICES B 2 CONDUCTOR #14 AWG FPL FOR CONNECTION TO HORN, BELL CIRCUITS c 11 2 CONDUCTOR #14 AWG FPL FOR CONNECTION TO STROBE CIRCUITS B 2 CONDUCTOR #14 AWG FPL FOR UNSWITCHED 24VDC POWER 2 CONDUCTOR #18 AWG FPL FOR SWITCHED 24VDC POWER B 2 CONDUCTOR #18 AWG FPL FOR MONITOR MODULES TO DIRECT SHORTING DEVICES -C, A Lm MIAMI MEDI BUILD,ING FIRE ALARM NOTES - SYSTEM 3 SYSTEM 1, ALL WIRING MUST CONFORM WITH NEC ARTICLE 760 AND LOCAL CODES. ALL EQUIPMENT SHALL BE UL LISTED. ALL DEVICES SHALL BE COMPATIBLE WITH THE CONTROL PANELS. SYSTEM IS POWER LIMITED PER NEC 760 AND UL 864 ,REQUIREMENTS. 2. ALL INITIATING AND INDICATING CIRCUITS MUST BE SUPERVISED. 3. CIRCUIT POLARITY MUST BE OBSERVED. 4. WIRE RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION OF ALL EQUIPMENT TO BE DETERMINED IN THE FIELD, BUT SHALL CONFORM WITH THE BASIC LAYOUT ASIiSHOWN ON DRAWINGS TO PREVENT CIRCUIT OVERLOAD. 5. MINIMUM CONDUIT SIZE WILL IBE 3/4 ". CONDUIT SHALL BE NO MORE THAN 40% FILLED PER NEC �IREQUIREMENTS. 6. POWER UP &POWER DOWN ON PANEL MUST BE DONE IN PROPER SEQUENCE. POWER DOWN A - DISCONNECT BATTERY. B -TURN OFF AC POWER PRIMARY &SECONDARY. POWER UP I A -TURN ON AC POWER PRIMARY &SECONDARY. B - RECONNECT BATTERIES. I 7. THE FIRE ALARM CONTROL PANEL SHALL NOT BE USED TO POWER ANY UNAUTHORIZED EXTERNAL DEVICE. 8. SIEMENS, 6BERUS DIVISION IS RESPONSIBLE FOR FIRE ALARM EQUIPMENT ONLY. ALL OTHER EQUIPMENT SHOWN ARE FOR DIAGRAMMATICAL PURPOSES. 9. DAMPER MOTOR AND FAN SHUTDOWN CONNECTIONS (IF ANY) ARE TO BE COORDINATED IN FIELD WITH'HVAC CONTRACTOR. 10. FIRE ALARM POWER SUPPLIES AND ALL REMOTE SUPPLIES MUST BE CONNECTED TO BUILDING OR COLD -WATER GROUND VIA 1 GREEN #10 THNN OR EQUIV. ii. ALL SURGE /TRANSIENT SUPRESSORS MUST BE CONNECTED TO BUILDING OR COLD -WATER GROUND. 12. FIRE ALARM INITIATING DEVICES SHALL NOT BE INSTALLED UNTIL CLEANUP OF ALL TRADES ARE COMPLETE. FAILURE TO COMPLY WITH THIS NOTE WILL VOID ALL WARRANTIES. 13. EVACUATION SIGNALS SHALL BE TEMPORAL IN ACCORDANCE WITH NFPA 72 3 -7.2 (A) AND ANSI 53.41. 14. VERIFY ALL MOUNTING HEIGHTS WITH AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. 15. UNDERGROUND WIRING IS ACCEPTABLE PROVIDED N.E.C. REQUIREMENTS FOR UNDERGROUND AND POWER LIMITED WIRING ARE MET. BUILDING DESCRIPTION THIS IS AN EXISTING 5 STORIES OFFICE BUILDING, FULLY SPRINKCLERED. FIRST PAGE SEQUENCE OF OPERATION 1. ACTIVATION OF ANY MANUAL INITIATION DEVICE WITHIN THE SYSTEM SHALL CAUSE THE FOLLOWING ACTIONS AND. INDICATIONS: 1) SOUND THE AUDIBLE CIRCUITS WITH THE EVACUATION TONE AND ACTIVATE THE VISUAL SIGNALS OF THROUGHOUT THE FACILITY. 2) ACTIVATE THE ALARM LIGHT AND SOUNDER AT THE FIRE ALARM CONTROL PANEL. 3) ACTIVATE THE ALARM LIGHT FOR THE ZONE THAT CONNECT$ TO THE DEVICE INITIATING THE EVENT. 2. ACTIVATION OF ANY AUTOMATIC FIRE DETECTION DEVICE WITHIN THE SYSTEM SHALL CAUSE THE FOLLOWING ACTIONS AND INDICATIONS: 1) SOUND THE AUDIBLE CIRCUITS WITH THE EVACUATION TONE AND ACTIVATE THE VISUAL SIGNALS 'OF THROUGHOUT THE FACILITY. 2) ACTIVATE THE ALARM LIGHT AND SOUNDER AT THE FIRE ALARM CONTROL PANEL. - 3) ACTIVATE THE ALARM LIGHT FOR THE ZONE THAT CONNECTS TO THE DEVICE INITIATING THE EVENT. 3. ACTIVATION OF ANY DUCT MOUNTED SMOKE DETECTORS SHALL, ACTIVATE A SUPERVISORY SIGNAL AT THE FACP AND ANNUNCIATORS, CAUSE THE SHUTDOWN OF THE ASSOCIATED AIR HANDLER OR CLOSURE OF THE ASSOCIATED DAMPER. COORDINATE WITH HVAC CONTRACTOR AND CONTRACT DOCUMENTS. 4. ACTIVATION OF ANY SMOKE DETECTORS IN A SINGLE ELEVATOR LOBBY, AN ELEVATOR EQUIPMENT ROOM OR ELEVATOR HOIST WAY SHALL, BESIDES THE ACTIONS DESCRIBED ABOVE, CAUSE THE'-RECALL OR THAT BANK OF ELEVATORS TO THE DESIGNATED LEVEL. 5. ACTIVATION OF THE SMOKE DETECTOR IN THE DESIGNATED LEVEL ELEVATOR LOBBY SHALL, BESIDES THE ACTIONS DESCRIBED ABOVE, CAUSE THE RECALL OF THAT BANK OF ELEVATORS Td THE ALTERNATE RECALL FLOOR. 6. ACTIVATION OF ANY SMOKE DETECTOR IN AN ELEVATOR EQUIPMENT ROOM SHALL, BESIDES THE ACTIONS DESCRIBED ABOVE, CAUSE THE ACTIVATION OF THE ELEVATOR WARNING LIGHTS IN THE MAIN AND ALTERNATE RECALL LOBBIES. 7. ACTIVATION OF ANY FIXED TEMPERATURE HEAT DETECTOR IN AN ELEVATOR HOIST WAY OR MACHINE ROOM SHALL CAUSE THE POWER TO THE ELEVATORS IN THAT BANK A TO SHUNT. DO NOT CONNECT SHUNT TRIP HEAT DETECTORS TO THE BUILDING 4laNkT_lw -c k FIRE ALARM SYSTEM. COORDINATE SHUNT TRIP OPERATION WITH ELEVATOR M CONTRACTOR. c, NQvcpw'fd m, 8. ACTIVATION OF ANY SUPERVISORY DEVICE WITHIN THE SYSTEM SHALL CAUSE THE FOLLOWING ACTIONS AND INDICATIONS: 1) ACTIVATE THE SUPERVISORY LIGHT AND SOUNDER AT THE FIRE ALARM CONTROL PANEL AND ANNUNCIATORS, IF ANY. 2) ACTIVATE THE SUPERVISORY LIGHT FOR THE ZONE THAT CONNECTS TO THE DEVICE INITIATING THE EVENT. 0 9. FLOW BELL OPERATION: A) FLOW BELL SHALL SOUND UPON THE ACTIVATION OF THE FLOW SWITCH ONLY. B) FLOW BELL SHALL SOUND THE ENTIRE TIME OF WATER FLOW. tNSTAUEDN';GC 6_E2D?►NCEWMi C) FLOW BELL SHALL BE INCAPABLE -OF BEING SILENCED FROM FCP. �/_.Ar�t; p7o; ioi- ay1,� Z irk ?,r Iif .4•i`'�, �4r� .6,,,`«AFL �I:� A D a MfA�t4r -•rar: ..�S``•'f �gtt °. f +r t'% t ; f a::uiyF 3T SCOPE OF WORKT�: INSTALLING 1 SMOKE DET. 2 HEAT DET. AND 2 RELAYS AND 1 FLOW BELL. TO THE EXISTING FIRE ALARM PANEL SYSTEM 3. THE SMOKE IS GOING ON THE ELEVATOR TOP OF SHAFT. 1 OF THE HEAT DET. IS GOING TO BE INSTALLED AT THE ELEVATOR MACHINE ROOM. THE OTHER HEAT DET. IS GOING TO BE INSTALLET AT THE ELEVATOR TOP OF SHAFT. THE RELAYS ARE GOING TO BE INSTALLED AT THE PANEL, ONE IS GOING TO BE USED FOR THE SHUNT TRIP AND THE OTHER ONE WILL BE USED FOR ELEVATOR WARNING LIGHT: DAMEL F. GUTIERREZ, PX 9360 CORAL WAY SUM MC. 1049086 wA a FL 33145 DFG PH.•(905)481 -317'8 CONSULTING ENGINEERS INC. �L�SZGN — INSPECTIONS c VI M O �1 M O N O Ln ♦� C X AV L 4 W d C .M_ W u M W LL, o �i iz o ��' 1 WCL CJ Z E0 NW www ab �� Z o 0 N as Ea 8 � U HLLj CL 0 0 LL Ld M H A g� u w z z O w w ll SHEET NO. U of 4