07-69-013FAN -COIL DESIGNATION CFM MBTUH ELECTRICAL DATA REF. UNIT REF. UNIT 088 TOTAL SENSIBLE VOLTS PHASES HTNG KW AMPS FUSES MANUFAC. LIQ. SUC. COND. AHU #1 1900 55.0 38.0 208 230 1 10 50 60 RHEEM RCHA60Al 3/8 3/4 2 FOIL FACED, CLASS I B. EXHAUST SYSTEM FOR BATHROOMS AND KITCHEN. FIBERGLASS DUCTWORK: FLEX —AIRE MC C. AIR CONDITIONING UNITS WITH REFRIGERANT PIPING AND CONTROLS. CONDENSING UNIT DESIGNATION TOTAL (BTUH) ELECTRICAL DATA MANUFAC. REF. UNIT OBSSEER AREA SERVED VOLTS PHASES AMPS FUSES CU #1 55.0 208 230 1 30 40 RHEEM RAMB060JAZ 12.0 SHOWN ORDINANCES. LT. SW. OPERATED 1.2 SCOPE OF WORK DUCT SCHEDULE PROVIDE THE FOLLOWING COMPLETE SYSTEMS FIBERGLASS DUCTS: OWENS— CORNING OR EQUAL, R -6 A. SUPPLY AND RETURN DUCT SYSTEM. AIR CONDITIONING NOTES GRILLE SCHEDULE MANUF.: AIR GUIDE CO MODEL CB W/ O.B.D. 1.0 GENERAL ALUM. CONSTRUCTION 1.1 PROVIDE ( FURNISH AND INSTALL) ALL NECESSARY FURNISH GRILLE BOOTS FOR FLEX DUCTS. FIRE DAMPER(S) MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL FAN SCHEDULE SMOKE DAMPER(S) AIR CONDITIONING, HEATING AND VENTILATING SYSTEM AS X FIRE RATED ENCLOSURE SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED EF —A BROAN MODEL 671 MODEL 670 FIRE RATED FLOOR ASSEMBLY INSTALL IN ACCORDANCE WITH THE FLORIDA 7o CFM ®1/8" ESP. 50 CFM FIRE STOPPING BUILDING CODE, ASHRAE, SMACK NFPA, AND LOCAL 1.15 AMPS. —120 -1 DIA. SMOKE CONTROL ORDINANCES. LT. SW. OPERATED 1.2 SCOPE OF WORK DUCT SCHEDULE PROVIDE THE FOLLOWING COMPLETE SYSTEMS FIBERGLASS DUCTS: OWENS— CORNING OR EQUAL, R -6 A. SUPPLY AND RETURN DUCT SYSTEM. 1 1/2" THK, NEOPRENE COATED FOIL FACED, CLASS I B. EXHAUST SYSTEM FOR BATHROOMS AND KITCHEN. FIBERGLASS DUCTWORK: FLEX —AIRE MC C. AIR CONDITIONING UNITS WITH REFRIGERANT PIPING AND CONTROLS. SYSTEM: CPE INNER CORE 1.3 PAY FOR ALL FEES, INSPECTIONS AND CONNECTION FOIL TAPE: NASHUA No.324 CHARGES REQUIRED. 1.4 VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS AND EQUIPMENT SIZES PRIOR TO DUCT FABRICATION OR INSTALLATION. COORDINATE REQUIREMENTS TO AVOID INTERFERENCE WITH OTHER TRADES. 1.5 SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF EQUIPMENT AND MATERIALS. 1.6 GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 2.0 MATERIALS 2.1 DUCTWORK 2.1.1 GENERAL. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR X FIRE DAMPER(S) X SMOKE DAMPER(S) X FIRE RATED ENCLOSURE X FIRE RATED FLOOR ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X T STRAP TO JCTURE (TYP) GER STRAP, GAUGE VIDE (MIN) 1LATED FLEX. T RGLASS (R -6) 2.1.2 MATERIAL. FIVE POUNDS DENSITY 1 2 " THICK GLASSFIBER FLEX DUCT HANGING DETAIL DESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SMACNA'S LOW PRESURE DUCT MANUAL. ALL N.T.S. DUCT JOINTS SHALL BE SEALED AND TAPED. 2.1.3 PROVIDE DOUBLE THICKNESS TURNING VANES AT ALL SQUARE ELBOWS. WHERE THE ELBOWS ARE RECTANGULAR INSTALL SINGLE THICKNESS INSTEAD. 2.1.4 PROVIDE VOLUME EXTRACTORS BEHIND EACH SUPPLY OUTLET AND AT EACH DUCT BRANCH. \ 2.2 REFRIGERANT PIPING. SEAMLESS COPPER TYPE "L" AND HARD OR SOFT DRAWN ON ACR COPPER TUBING WITH WROUGHT COPPER SOLDER JOINT FITTINGS, SOLDER DAMPER SHALL BE 95/5 APPLIED WITH SUITABLE FLUX. 2.3 INSULATE ALL REFRIGERANT SUCTION PIPING WITH 3/4" Ducr TRANSITION - CLOSED CELL POLYETHYLENE PREMOLDED PIPE INSULATION, WITH AN APPROVED PIPE AND SMOKE JACKET. PAINT ALL EXPOSED INSULATION WITH TWO COATS OF WHITE LATEX PAINT. PROVIDE AIR CONDITIONING UNITS WITH MATCHING LOW 2.4 VOLTAGE HEAT -COOL THERMOSTATS WITH ON -OFF AUTO SUB -BASE SWITCH, FURNISHED BY THE EQUIPMENT MANUFACTURER. 2.5 ALL AIR CONDITIONING COMPRESSORS SHALL BE WARRANTED FOR A MINIMUM OF FIVE YEARS AFTER DATE OF ACCEPTANCE OF THE PROJECT. 2.7 AIR DISTRIBUTION PRODUCTS 2.7.1 PROVIDE SUPPLY AND RETURN GRILLES AND DIFFUSERS AS INDICATED ON THE DRAWINGS. 2.7.2 PROVIDE EXTRUDED ALL ALUMINIUM AIR DISTRIBUTION COIL /HEAT — PRODUCTS. SECTION 2.7.3 PROVIDE FINISHES AND TYPES OF MOUNT IN COORDINATION WITH THE CEILING TYPES AS SHOWN ON ARCHITECTURAL DRAWINGS. FAN SECTION 2.7.4 PROVIDE OPPOSED BLADE, KEY OPERATED DAMPERS BEHIND ALL AIR SUPPLY OUTLETS. FILTER ACCES 3.0 INSTALLATION 3.1 INSTALL ALL EQUIPMENT IN ACCORDANCE TO THE MANUFACTURER'S MANUAL AND RECOMMENDATIONS, PAYING SPECIAL ATTENTION TO REQUIRED CLEARANCES FOR INSTALLATION, OPERATION AND SERVICE. BIRD SCREEN ROOF TILE ON B.U.R. GALV. DUCT FROM KITCHEN HOOD 6' AND EXHAUST FAN BATH (4') EXHAUST ROOF CAP DETAIL OAN NTS, DISCHARGE AIR PLENUM SHALL BE MECHANICALLY ATTACHED TO AHU (FMC 603.7) CEILING WALLS REF LINES TO 2" CONDENSATE DRAIN W /3" TRAP SEAL, UNION AND C.0 TO GREEN AREA AS PER FBC SEC 307.2.3. SEE MECHANICAL. 2" PVC DRAIN TO 6" ABOVE GRADE /' AND A SAFETY SECONDARY SECONDARY,;/ DRAIN WITH SAFETY SHUT OFF SWITCH SEE PLAN FOR DRAIN LOCATION. 3.2 BALANCE ALL SYSTEMS TO PROVIDE AIR QUANTITIES AND / \- PREFAB FRAME CAPACITIES. INDICATED ON DRAWINGS. SUBMIT FINALTEST 2" COND. DRAINAGE AND BALANCE REPORT TO ARCHITECT / ENGINEER FOR SEE MECHANICAL ACCEPTANCE. F.F. C DWG FOR LOCATION NOTE: MAINTAIN 4" MINIMUM CLEARANCE ALL AROUND A.H.U. A.H.U. UNIT INSTALATION DETAIL N.T.S. 0 E.GARAGE M.CLOSET 40 CFM 6X6, CD I 180 CFM 12X8, CD DEN M.BATH v so cart v 1 oxs�e—�t 1 280 CMAS 12X10 4CD \491-0 FAMILY 200 CFM 10X10 4CD :F_l VTR BATH EF -2 '10 0 BEDROOM EF -A VTt� 10 CFM , � 12'4, KIT�HEN lb5 Cf M I 1 bx6, CD 4\ CONDENSING UNIT 6" MIN. ISOMODE PAD MID.) 3" x 2" x 1/8" ANGLE 3/8" x 1 1/2* EXPANSION BOLT TO ' ', , CONC. BASE 6" MIN. .... CONCRETE BASE W/ 6 X 6 — 10/10 WWF STRAP UNIT AS SHOWN POWER do CONTROL CONNECTIONS �i6" MIN. 4" MIN. LIQUID LINE W/O INSULATION 6"0 SCHEDULE SEAL ENTRANCE OF REFRIGERANT 40 P.V.C. PIPE LINES INTO P.V.C. PIPE W/ INCREASE SIZE IMPERMEABLE, RESILENT MATERIAL AS REQUIRED BY LENGTH AND ROUTING ARMAFLEX INSULATION do VAPOR BARRIER CONDENSING UNIT MOUNTING DETAIL LOW VELOCITY N.T.S. SUPPLY AIR DUCT (SEE PLAN VIEW) AIR FLOW SEAL JOINT WITH DUCT SEALER & TAPE DRAW BAND SPIN COLLAR FITTING WITH DAMPER DIFFUSER REGISTER SPIN COLLAR FITTING WITH DAMPER INSULATED FLEX. DUCT (R -6) SEAL JOINT WITH DUCT SEALER & TAPE FLEXIBLE DUCT CONNECTION DETAIL �o �z 0 V ae O aD ' PVC DRAIN TO 6' ABOVE v I 3RADE AND A SAFETY SECONDARY DRAIN W/ SAFETY SHUT OFF SWITCH AS PER F$-C. SEC. 30123 0 CFM 25 150 CPM 4 ¢ � N. \ 6X6,CD 10X6, CD h• 1080 12,E � � \ E.BATH �� E.BEDROOM 3 Z R/A W 10'x' NEW REF. LI 24'x t — — AT ATTIC 8P E ®+ 300 CFM \ a'o 2X100 4CD 12X10 4CD R/ /NOTE: M TAIN A 6' c" #' Z r 10 0 CLEARANCE-4p AHU _I � J OJ '1�1 Ll 0 � !J �� 4 w 141# ,0 \810 \8 — 0 a GREAT ROOM I H 140 CFM a 10X6, CD Z 100 GI=M / A I W B 1 ox6, CD E.BEDROOM 2 E.BEDROOM 4 Z N 0 Z o� N c � f 0 J IL 0 0.0 m@ 7 21% a �W 0 aZ 0 in C'i a d 0 0 0 W Z 0 l J n fj O v jn W �aa F. sic N 4410 _I 0 OZ O •X Q AJL MECHANICAL PLAN NOTE: SUBCONTRACTORS TO VERIFY FIELD CONDITIONS PRIOR TO SUBMITTING BID. 1/4" 'JOB No. 0326 CAD FILE: GUS DATE: 12/29/03 M -1 3 1/4" 'JOB No. 0326 CAD FILE: GUS DATE: 12/29/03 M -1