Loading...
07-69-012ELECTRICAL NOTES: 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. 2. COORDINATE ELECTRICAL SERVICE W /FLORIDA POWER AND LIGHT COMPANY. 3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE COMPANY SPECIFICATIONS. 4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN IS IN COMPLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY CODES. 5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS. 6. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR. IT WILL BE HIS RESPONSIBILITY TO SECURE AND PAY FOR ANY PERMITS, CERTIFICATES OF INSPECTION, AS REQUIRED. 7. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE MADE WITHOUT APPROVAL OF THE ENGINEER. IF THE USE OF A SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. AND IF APPROVED, SHALL BE MADE AT NO COST TO THE OWNER. 8. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR ABUTTING WORK TO BE PERFORMED BY OTHERS. 9. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFACTURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, UNLESS OTHERWISE INDICATED. LIKE ITEMS SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER. 10. ALL CONDUCTORS SHALL BE COPPER. WIRE SIZE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE GROUND CONDUCTOR PER NEC 250 -95. THE USE ROMEX IS ALLOWED. 11. LOCATION OR OUTLETS IN ELECTRICAL DRAWINGS IS DIAGRAMMATIC: CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 12. CIRCUIT NUMBERS SHOWN ARE FOR CALCULATION PURPOSES ONLY. ACTUAL CIRCUITING MAY VARY ACCORDING TO NEC AND SFBC PROVIDE PANEL SCHEDULE AFTER COMPLETION. 13. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. HACR CIRCUIT BREAKERS MAY BE USED IN PLACE OF FUSES. USE NON- AUTOMATIC SWITCH FOR A/C COND. DISCONNECT. NOTE: SUBCONTRACTORS TO VERIFY FIELD CONDITIONS PRIOR TO SUBMITTING BID. ELECTRICAL RISER NEW 3 #2/0 IN 1 1/2- COP NEW ELECTRICAL METER 1v #4 (CU.) - 1/2" C. NEW 2 -8' -0" DEEP GROUNI ROD 6' O.C. - 5/8" 1 VOLTAGE 240/120V 10 - 3w PANEL: A NEW MAIN BUS: 200 AMP. NEUTRAL : 200 AMP. MAINS : 200 AMP LOCATION : SHOWN AMPS POLES TOTAL WIRE DESCRIPTION CKT. 12000 DRYER 5000 CKT. DESCRIPTION WIRE TOTAL POLES AMPS 60 2 10200 6 A/C AHU #1 1 2 RANGE 6 12000 2 50 CONNECTED LOAD LESS A/C = 42.107 W 10,000W @ 100% = 10000 REST W @ 40% = 12843 A/C OR HEATING @ 65% = 10200 3 4 40 2 6200 8 A/C C.U. #1 5 6 REFRIGERATOR 12 1500 1 20 7 8 FLOOD LGTS. 12 * 1 20 20 1 800 12 DISPOSAL 9 10 BATH LGTS. 14 * 1 15 20 1 1200 12 DISHWASHER 11 12 BATH GFI RECEP. 12 * 1 20 20 1 1500 12 SMALL APPL. 13 14 KIT. LGTS. 14 * 1 15 20 1 1500 12 SMALL APPL. 15 16 WASHER 12 1500 1 20 25 2 4500 10 WATER HEATER 17 18 MICROWAVE 12 1200 1 20 19 20 GEN. LT. & RECEP. 14 * 1 15 30 2 5000 10 DRYER 21 22 GEN. LT. & RECEP. 14 * 1 15 23 24 GEN. LT. & RECEP. 14 * 1 15 15 * 1 14 GEN. LT. & RECEP. 25 26 GEN. LT. & RECEP. 12 * 1 20 15 * 1 14 GEN. LT. & RECEP. 27 28 GARAGE DR. OPEN. 12 600 1 20 15 * 1 14 GEN. LT. & RECEP. 29 30 GEN. LT. & RECEP. 14 * 1 15 20 2000 2 12 POOL PUMP 31 32 GEN. LT. & RECEP. 14 * 1 15 33 34 GEN. LT. & RECEP. 14 * 1 15 20 2000 2 12 WHIRLPOOL 35 36 GEN. LT. & RECEP. 14 * 1 15 37 38 POOL LIGHTING 12 * 1 20 - 20 2000 2 12 SPRINKLER PUMP 39 40 SPARE 41 42 GENERAL LIGHTING 2669 SQ. FT. @ 3W/SQ. FT. = WATTS 8007 SMALL APPLIANCE CIRCUITS: 2 CIRCUITS x 1500 F 3000 FIXED APPLIANCES: RANGE 12000 DRYER 5000 REFRIGERATOR 1500 WASHER 1500 DISHWASHER 1200 WHIRLPOOL 2000 WATER HEATER 4500 SPRINKLER PUMP 2000 DISPOSER 800 GARAGE DOOR OPENER 600 POOL PUMP 2000 CONNECTED LOAD LESS A/C = 42.107 W 10,000W @ 100% = 10000 REST W @ 40% = 12843 A/C OR HEATING @ 65% = 10200 DEMAND LOAD: 32843 /240 WATTS = 137 AMPS @ 240/120V PANEL SIZE = 200 AMPS NOTES: A/C @ 100% = 10,200 HEAT @ 65% = 6,630 WALL SWITCH 15A, 125V $' 3 -WAY WALL SWITCH 15A, 125V I`@-- DUPLEX RECEPTACLE OUTLET 15A, 125V 4D= SWITCHED DUPLEX RECEP. OUTLET 15A, 125V G) DUPLEX FLOOR RECEPTACLE, 15A, 125V G- SIMPLEX RECEPTACLE OUTLET 15A, 125V ® SPECIAL RECEPTACLE OUTLET 1-0 WALL MOUNTED LIGHTING FIXTURE CEILING LIGHTING FIXTURE Q JUNCTION BOX 0 HI -HAT t TELEPHONE JACK p TELEVISION OUTLET D FUSE OR DISCONNECT SWITCH 0 SMOKE DETECTOR SD ,r EXHAUST FAN ["I ELECTRICAL METER /MAIN 0 ELECTRICAL PANEL (NTS) NEW 200 AMP DISC. NEW 3 # 2/0 THWN (CU.) & #6 (CU.) IN 1 1/2" C. NEW 200AMP. ELECT. PANEL NEW TO COLD WATER PIPE klrui r L rrro ELECTRICAL PLAN N ec, 216.►2 (4 F (2-r- C__� L cu)- � KITCHEN OR SWITCH LEG SMOKE DETECTOR LINE SIDE OF SWITCH PHASE CONDUCTOR SMOKE DETECTOR CONNECTION DETAIL N.T.S. ALL SMOKE ETECTORS SHALL BE HARDWIRED (110 VOLT TYPE) TO A NON- SWITCHABLE KPrRZN OR BAT M LIGHTING CIRCUIT WITH BATTERY BACK -UP AND SHALL NOT BE CONNEC D ONTO THE LOAD SI E OF GROUND FAULT CIRCUIT INTERRUPTER. ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED. SMOKE DETECTOR SHALL NOT BE PLACED WITHIN 3' -0" OF ANY A/C GRILL. R,1 0 L3 T (,TS T,C) Yin ee,t- N EC. 210, t2 2 10, 52 1/4•• SPRINKLER PUMP A39/41 WP P PUMP A31 00 y33 WP o0 00 130 oa 0 W cq c7 0 a � a Q O o Q J � W 0 ■ o c W WW Q J u. rn O V 3 W GC o N o m co la' J � Ws vo 0 0 mi Z Z W L W W Im I- a N Z I- q* 4 Z Z � �■ 4 r O N REVISION No. DESCRIPTION DATE: JOB No. 0326 CAD FILE: GUS DATE: 12 -29 -03 E -1