07-69-012ELECTRICAL NOTES:
1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL
ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES.
2. COORDINATE ELECTRICAL SERVICE W /FLORIDA POWER AND LIGHT
COMPANY.
3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE COMPANY
SPECIFICATIONS.
4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN IS IN COMPLIANCE AS
SET FORTH BY STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY
CODES.
5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR
HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS.
6. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED
ELECTRICAL CONTRACTOR. IT WILL BE HIS RESPONSIBILITY TO SECURE AND
PAY FOR ANY PERMITS, CERTIFICATES OF INSPECTION, AS REQUIRED.
7. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE MADE
WITHOUT APPROVAL OF THE ENGINEER. IF THE USE OF A SUBSTITUTE
REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR SUCH CHANGE WILL
BE BROUGHT TO THE ATTENTION OF THE ENGINEER. AND IF APPROVED,
SHALL BE MADE AT NO COST TO THE OWNER.
8. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND
LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED
CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLESS SO
SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR ABUTTING WORK TO BE
PERFORMED BY OTHERS.
9. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET WITH
THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND SHALL BE NEW
AND THE LATEST STANDARD PRODUCTS OF MANUFACTURERS REGULARLY
ENGAGED IN THE PRODUCTION OF THE ITEM, UNLESS OTHERWISE INDICATED.
LIKE ITEMS SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER.
10. ALL CONDUCTORS SHALL BE COPPER. WIRE SIZE SHALL BE THWN
UNLESS OTHERWISE NOTED ON PLANS. PROVIDE GROUND CONDUCTOR PER
NEC 250 -95. THE USE ROMEX IS ALLOWED.
11. LOCATION OR OUTLETS IN ELECTRICAL DRAWINGS IS DIAGRAMMATIC:
CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS.
12. CIRCUIT NUMBERS SHOWN ARE FOR CALCULATION PURPOSES ONLY.
ACTUAL CIRCUITING MAY VARY ACCORDING TO NEC AND SFBC PROVIDE
PANEL SCHEDULE AFTER COMPLETION.
13. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON
A/C EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CONTRACTOR
IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN
ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF
DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER
CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE
ABOVE MENTIONED CHANGES AT NO EXTRA COST. HACR CIRCUIT BREAKERS
MAY BE USED IN PLACE OF FUSES. USE NON- AUTOMATIC SWITCH FOR A/C
COND. DISCONNECT.
NOTE:
SUBCONTRACTORS TO VERIFY FIELD CONDITIONS
PRIOR TO SUBMITTING BID.
ELECTRICAL RISER
NEW
3 #2/0 IN 1 1/2- COP
NEW
ELECTRICAL METER
1v #4 (CU.) - 1/2" C.
NEW
2 -8' -0" DEEP GROUNI
ROD 6' O.C. - 5/8" 1
VOLTAGE 240/120V 10 - 3w PANEL: A NEW MAIN BUS: 200 AMP.
NEUTRAL : 200 AMP.
MAINS : 200 AMP
LOCATION : SHOWN
AMPS
POLES
TOTAL
WIRE
DESCRIPTION
CKT.
12000
DRYER
5000
CKT.
DESCRIPTION
WIRE
TOTAL
POLES
AMPS
60
2
10200
6
A/C AHU #1
1
2
RANGE
6
12000
2
50
CONNECTED LOAD LESS A/C = 42.107 W
10,000W @ 100% =
10000
REST W @ 40% =
12843
A/C OR HEATING @ 65% =
10200
3
4
40
2
6200
8
A/C C.U. #1
5
6
REFRIGERATOR
12
1500
1
20
7
8
FLOOD LGTS.
12
*
1
20
20
1
800
12
DISPOSAL
9
10
BATH LGTS.
14
*
1
15
20
1
1200
12
DISHWASHER
11
12
BATH GFI RECEP.
12
*
1
20
20
1
1500
12
SMALL APPL.
13
14
KIT. LGTS.
14
*
1
15
20
1
1500
12
SMALL APPL.
15
16
WASHER
12
1500
1
20
25
2
4500
10
WATER HEATER
17
18
MICROWAVE
12
1200
1
20
19
20
GEN. LT. & RECEP.
14
*
1
15
30
2
5000
10
DRYER
21
22
GEN. LT. & RECEP.
14
*
1
15
23
24
GEN. LT. & RECEP.
14
*
1
15
15
*
1
14
GEN. LT. & RECEP.
25
26
GEN. LT. & RECEP.
12
*
1
20
15
*
1
14
GEN. LT. & RECEP.
27
28
GARAGE DR. OPEN.
12
600
1
20
15
*
1
14
GEN. LT. & RECEP.
29
30
GEN. LT. & RECEP.
14
*
1
15
20
2000
2
12
POOL PUMP
31
32
GEN. LT. & RECEP.
14
*
1
15
33
34
GEN. LT. & RECEP.
14
*
1
15
20
2000
2
12
WHIRLPOOL
35
36
GEN. LT. & RECEP.
14
*
1
15
37
38
POOL LIGHTING
12
*
1
20
- 20
2000
2
12
SPRINKLER PUMP
39
40
SPARE
41
42
GENERAL LIGHTING
2669 SQ. FT. @ 3W/SQ. FT. =
WATTS
8007
SMALL APPLIANCE CIRCUITS:
2 CIRCUITS x 1500 F 3000
FIXED APPLIANCES:
RANGE
12000
DRYER
5000
REFRIGERATOR
1500
WASHER
1500
DISHWASHER
1200
WHIRLPOOL
2000
WATER HEATER
4500
SPRINKLER PUMP
2000
DISPOSER
800
GARAGE DOOR OPENER
600
POOL PUMP
2000
CONNECTED LOAD LESS A/C = 42.107 W
10,000W @ 100% =
10000
REST W @ 40% =
12843
A/C OR HEATING @ 65% =
10200
DEMAND LOAD: 32843 /240 WATTS = 137 AMPS @
240/120V
PANEL SIZE = 200 AMPS
NOTES: A/C @ 100% = 10,200
HEAT @ 65% = 6,630
WALL SWITCH 15A, 125V
$' 3 -WAY WALL SWITCH 15A, 125V
I`@-- DUPLEX RECEPTACLE OUTLET 15A, 125V
4D= SWITCHED DUPLEX RECEP. OUTLET 15A, 125V
G) DUPLEX FLOOR RECEPTACLE, 15A, 125V
G- SIMPLEX RECEPTACLE OUTLET 15A, 125V
® SPECIAL RECEPTACLE OUTLET
1-0 WALL MOUNTED LIGHTING FIXTURE
CEILING LIGHTING FIXTURE
Q JUNCTION BOX
0 HI -HAT
t TELEPHONE JACK
p TELEVISION OUTLET
D FUSE OR DISCONNECT SWITCH
0 SMOKE DETECTOR
SD
,r EXHAUST FAN
["I ELECTRICAL METER /MAIN
0 ELECTRICAL PANEL
(NTS)
NEW
200 AMP DISC.
NEW
3 # 2/0 THWN (CU.)
& #6 (CU.)
IN 1 1/2" C.
NEW
200AMP. ELECT.
PANEL
NEW
TO COLD WATER PIPE
klrui r L rrro
ELECTRICAL
PLAN
N ec, 216.►2
(4 F (2-r- C__� L cu)- �
KITCHEN OR
SWITCH LEG
SMOKE DETECTOR
LINE SIDE
OF SWITCH
PHASE CONDUCTOR
SMOKE DETECTOR CONNECTION DETAIL N.T.S.
ALL SMOKE ETECTORS SHALL BE HARDWIRED (110 VOLT TYPE) TO A NON- SWITCHABLE KPrRZN
OR BAT M LIGHTING CIRCUIT WITH BATTERY BACK -UP AND SHALL NOT BE CONNEC D ONTO
THE LOAD SI E OF GROUND FAULT CIRCUIT INTERRUPTER. ALL SMOKE DETECTORS WITHIN EACH
UNIT SHALL BE INTERCONNECTED.
SMOKE DETECTOR SHALL NOT BE PLACED WITHIN 3' -0" OF ANY A/C GRILL.
R,1 0 L3 T (,TS T,C) Yin ee,t- N EC.
210, t2 2 10, 52
1/4••
SPRINKLER PUMP
A39/41 WP
P PUMP
A31 00 y33 WP
o0
00
130
oa
0
W
cq
c7 0
a � a
Q
O o
Q
J � W
0
■ o
c
W
WW Q
J
u.
rn
O V 3
W GC o N
o m
co
la'
J
� Ws
vo
0
0
mi
Z Z W L
W W Im
I- a N
Z I- q* 4
Z Z � �■
4
r O
N
REVISION
No. DESCRIPTION DATE:
JOB No. 0326
CAD FILE: GUS
DATE: 12 -29 -03
E -1