07-69R-005ELECTRICAL NOTES: 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. 2. COORDINATE ELECTRICAL SERVICE W /FLORIDA POWER AND LIGHT COMPANY. 3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE COMPANY SPECIFICATIONS. 4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN IS IN COMPLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY CODES. 5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS. 6. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR. IT WILL BE HIS RESPONSIBILITY TO SECURE AND PAY FOR ANY PERMITS, CERTIFICATES OF INSPECTION, AS REQUIRED. 7. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE MADE WITHOUT APPROVAL OF THE ENGINEER. IF THE USE OF A SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. AND IF APPROVED, SHALL BE MADE AT NO COST TO THE OWNER. 8. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR ABUTTING WORK TO BE PERFORMED BY OTHERS. 9. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFACTURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, UNLESS OTHERWISE INDICATED, LIKE ITEMS SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER. 10. ALL CONDUCTORS SHALL BE COPPER. WIRE SIZE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE GROUND CONDUCTOR PER NEC 250 -95. THE USE ROMEX IS ALLOWED. 11. LOCATION OR OUTLETS IN ELECTRICAL DRAWINGS IS DIAGRAMMATIC: CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 12. CIRCUIT NUMBERS SHOWN ARE FOR CALCULATION PURPOSES ONLY. ACTUAL CIRCUITING MAY VARY ACCORDING TO NEC AND SFBC PROVIDE PANEL SCHEDULE AFTER COMPLETION. 13. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. HACR CIRCUIT BREAKERS MAY BE USED IN PLACE OF FUSES. USE NON— AUTOMATIC SWITCH FOR A/C COND. DISCONNECT. FPOLEI /120V 10 - 3W METER COMBO MAIN BUS :200 AMP. NEUTRAL 200 AMP. MAINS 200 AMP. LOCATION : SHOWN TOT' WIRE DESCRIPTION CKT. CKT. DESCRIPTION WIRE TVAAL POLES AMPS 0 14 GATE MOTOR 1 2 SPRINKLER PUMP 12 1200 2 20 0 14 GATE MOTOR 3 4 OPEN 5 6 SPARE 20 VOLTAGE : 240/120V 10 — 3W NEW PANEL A MAIN BUS: 200 AMP. NEUTRAL 200 AMP. MAINS 200 AMP LOCATION : SHOWN AMPS POLES TOTAL VA WIRE DESCRIPTION CKT. 6500 0 OVEN CKT. DESCRIPTION WIRE 16500 TOTAL VA POLES AMPS 20 2 1200 12 POOL PUMP 1 2 RANGE 6 4500 2 50 1500 W Z �. WHIRLPOOL 1200 x w WATER HEATER 4500 3 3 4 DISPOSER 800 V GARAGE DOOR OPENER 600 0 h POOL PUMP 20 1 1200 12 WHIRLPOOL 5 6 OVEN 6 6500 1 2 50 10,000W 0 100% = 10000 REST W 0 40% = 16443 A/C OR HEATING 0 65% = 6500 7 8 ) 20 1 800 12 DISPOSAL 9 10 REFRIGERATOR 12 1500 1 20 20 1 1 1200 12 DISHWASHER 11 12 REFRIGERATOR 12 1500 1 20 20 1 1500 12 SMALL APPL. 13 14 BATH LGTS. 14 1 15 20 1 1500 12 SMALL APPL. 15 16 BATH GFI RECEP. 12 1 20 25 2 4500 10 WATER HEATER 17 18 KIT, LGTS. 14 1 15 19 20 MICRO WAVE 12 1200 1 20 30 2 5000 10 DRYER 21 22 GARAGE DR. OPEN 12 600 1 20 23 24 PIER LITES 12 1 20 20 1 1500 12 WASHER 25 26 GEN. LT. & RECEP 14 1 15 20 1 12 POOL LIGHTING 27 28 GEN. LT. & RECEP 14 1 15 15 1 14 GEN. LT. & RECEP. 29 30 GEN. LT. & RECEP 14 1 15 15 1 1 14 IGEN. LT. & RECEP. 31 32 GEN. LT. & RECEP 14 1 15 15 1 1 14 IGEN. LT. & RECEP. 33 34 GEN. LT. & RECEP 14 1 15 15 1 14 GEN. LT. & RECEP. 35 36 GEN. LT. & RECEP 14 1 15 15 1 14 GEN. LT. & RECEP. 37 38 GEN. LT. & RECEP 14 1 15 15 1 14 IGEN. LT. & RECEP. 39 40 PANEL 8 6 2 50 20 1 12 42 1 VOLTAGE : 240/120V 10 - 3W AsOPS P02ES 10000 6RE DA /CRIAH O# VA NEW PANEL B CKT. I I CKT. I DESCRIPTION t 2 A/C C.U. 1' WALL SWITCH 15A, 125V 3 3 —WAY WALL SWITCH 15A, 125V �Q= DUPLEX RECEPTACLE OUTLET 15A, 125V 00= SWITCHED DUPLEX RECEP. OUTLET 15A, 125V 0 DUPLEX FLOOR RECEPTACLE, 15A, 125V 0- SIMPLEX RECEPTACLE OUTLET 15A, 125V 0 SPECIAL RECEPTACLE OUTLET FO WALL MOUNTED LIGHTING FIXTURE CEILING LIGHTING FIXTURE Q JUNCTION BOX HI —HAT TELEPHONE JACK © TELEVISION OUTLET E) FUSE OR DISCONNECT SWITCH SMOKE DETECTOR so N EXHAUST FAN C'Ll ELECTRICAL METER /MAIN ® ELECTRICAL PANEL NEUTRAL : 50 AMP. MAINS 50 AMP. LOCATION : SHOWN TOTAL WIRE VA POLES AMF 8 162001 2 1 40 NOTE: SUBCONTRACTORS TO VERIFY FIELD CONDITIONS PRIOR TO SUBMITTING BID. ELECTRICAL RISER (N TS) NEW 3 #2/0 IN 1 1/2" CONDUIT NEW ELECTRICAL METER 3E# 2/0 THWN (CU.) COMBO & #6 (CU.) PANEL A IN 1 1/2 C. PANEL 8 NEW NEW 200AMP DISC. 200AMP. ELECT. NEW PANEL PANEL P. ELECT. 1J #4 (CU.) - 1/2" C. NEW 2 -8' -0" DEEP GROUNDING — ROO 6' O.C. - 5/8" DIAMETER E NEW TO COLD WATER PIPE GENERAL LIGHTING I 2669 SQ. FT. 0 3W SQ. FT. = r V 7WATTS SMALL APPLIANCE CIRCUITS. 2 CIRCUITS x 1500 = FIXED APPLIANCES: Q v RANGE 6500 0 OVEN 6500 fl. MICRO WAVE 1200 � REFRIGERATOR 1500 � REFRIGERATOR 1500 mo DRYER 5000 W 0 WASHER 4500 �.. DISHWASHER 1500 W Z �. WHIRLPOOL 1200 x w WATER HEATER 4500 3 SPRINKLER PUMP 1200 DISPOSER 800 V GARAGE DOOR OPENER 600 0 h POOL PUMP 1200 GATE MOTOR 1200 GATE MOTOR 1 1200 CONNECTED LOAD LESS A/C = 51107W 10,000W 0 100% = 10000 REST W 0 40% = 16443 A/C OR HEATING 0 65% = 6500 DEMAND LOAD: 32943 /240 WATTS = 137 AMPS 0 240/120V PANEL SIZE = 200 AMPS 3E# 6 THWN (CU.) & #10 (CU.) IN 1" C. SPRINKLER PUMP ELECTRICAL P 4(e` Opp /441/ �iA�R� J�✓ O` J —0- ICI 1 O3 PUMP CU yt /GFI 6 N W r V 4.- DESCRIPTION Q v Q � 0 J Q fl. J � u - io H � v 0 O mo W W W 0 N �.. a LL W V Z Q 0 Q W Z �. 3 N 0) N m LL x w O� 3 a m W 0 o N V Q Qi 0 h 9 ) y SPRINKLER PUMP ELECTRICAL P 4(e` Opp /441/ �iA�R� J�✓ O` J —0- ICI 1 O3 PUMP CU yt /GFI 6 N W r V 4.- DESCRIPTION Q v Q � 0 J Q fl. J � u - io H � v 0 O mo W W W 0 N �.. a LL W V Z Q 0 Q W Z �. 3 N 0) N m LL x w O� 3 a m W 0 o N V Q Qi 0 h L i, . -, J Q 0 REVISION W V No. DESCRIPTION DATE: Q 0 r Q Cc H Z � W �- 0 J �' _w H 2 N Z W V Z Q 0 Q W Z �. 3 N 0) N m 0 0) JOB No. 0326 CAD FILE: GUS DATE: 12 -29 -03 E -1 REVISION No. DESCRIPTION DATE: 1 ENTRANCE 7 -1 -04 2 1 AS BUILT 1 -18 -08 L_ JOB No. 0326 CAD FILE: GUS DATE: 12 -29 -03 E -1