07-69R-002ZONING LEGEND
ZONING:
RS -4
HEIGHT(TO RIDGE OF ROOF) 12' -8"
NET LAND AREA 11,129 SQ.FT.
LOT COVERAGE 3,044 SQ.FT.
SETBACKS: REQ. PRQVIVED
FRONT 25'
SIDE 5!-- t
SIDE STREET 15' 1
REAR 25'';,If) �'- I:2s -iW
•PRE - EXISTING PERMITTED ADDITION.
AREA ADJACENT TO LAKE OR CANAL TO BE GRADED SO AS
TO PREVENT DIRECT OVERLAND DISCHARGE OF
STORMWATER INRO LAKE OR CANAL.
LOT WILL BE GRADED SO AS TO PREVENT DIRECT OVERLAND
DISCHARGE OR STORMWATER ONTO ADJACENT
PROPERTY. APPLICANT WILL PROVIDE CERTIFICATION PRIOR TO
FINAL INSPECTION.
ANY APPLICABLE RESOLUTIONS:
NOTICE:
IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT, THERE
MAY BE ADDITIONAL RESTRICTIONS APPLICABLE TO THIS
PROPERTY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF
THIS COUNTY. SECTION 553.79(10), FLORIDA STATUTES,
EFFECTIVE 7/10/87.
APPLICANT: WILL COMPLY WITH ORDINANCE 80 -90 (SECTION
13 -13.1 OF THE METROPOLITAN DADE COUNTY CODE: NOTICE
OF ROCK MINING OPERATIONS WHERE BLASTING IS PERMITTED)
PRIOR TO STARTING CONSTRUCTION.
A SEPARATE PERMIT WILL BE REQUIRED FOR ALL DRIVEWAY
APPROACHES ONTO PUBLIC RIGHT OF WAY. CONTACT PUBLIC
WORKS DEPARTMENT.
THE HEIGHT OF FENCES, WALLS AND HEDGES SHALL NOT
EXCEED 2.5 FEET IN HEIGHT WITHIN 10 FEET OF THE EDGE
OF ANY DRIVEWAY LEADING TO A RIGHT OR WAY.
THE HEIGHT OF FENCES IS BEING MEASURED FROM GRADE.
GRADE = ELEVATION OF PUBLIC SIDEWALK OR CROWN OF
ROAD.
GENERAL NOTC
1. The Contractor shall verify all dimensions, elevations, angles
and all other existing conditions prior to commencing any
work. Contractor to also verify all information on drawings.
Acceptance of these plans constitutes approval. Notify Architect
by certified mail of any conflicts or discrepancies, if any.
2. The Contractor shall furnish and be solely responsible for
all temporary bracing and shoring required to maintain plumbness
and stability of all structural elements during construction.
3. The Contractor shall obtain from all subcontractors the
the final approved site and location of all openings to be
provided for respective trades. He shall be responsible for
location and details.
4. Owner and Contractor shall notify Architect in writing, by
certified mail upon commencement project.
5. The Owner shall be solely responsible for investigation in
reference to whether structure can be built on site.
6. The Contractor shall follow the Frorido Buildibg Code and any
other pertinent local codes.
SQUARE FOOTAGE CALCULATION
EXISTING
A/C SPACE
2,319 sq.ft.
COVERED ENTRY
100 sq.ft.
GARAGE
275 sq.ft.
PROPOSED
14.0 FT. NCSVD
A/C SPACE
350 sq.ft.
TOTAL UNDER ROOF
3,044 sq.ft.
LOT COVERAGE
CALCULATION
TOTAL UNDER ROOF
3,044 SQ.FT.
NET LAND
1 1,129 SQ.FT.
TOTAL FOOTPRINT 27.4%
FPL POLE 112.44 9
E ITE
. 42 TERRACE- 50' R/
28' ASPHALT ROADWAY
Lowest Floor Elev.0rcluding
basement /sunken areas)
Garage/ Storage Floor
Elevation
Adjacent Grade Elevation
(next to the wall of the structure)
EXISTING
14.66 FT. NGVD
14.08 FT. NGVD
14.0 FT. NCSVD
PROPOSED
14.66 FT. NGVD
14.08 FT. NGvD
14.0 FT, NGVD
i
FPL POLE 112.44 9
E ITE
. 42 TERRACE- 50' R/
28' ASPHALT ROADWAY
1/8"
I
REVISION
W
Qo
�
t
W
OC
W
A
J
L
OJ_aa
i
a
■ F
i i
U J
WW
W
I
Fm
a
J
i
J
r 3 L
O V
i
a
i
m
N
d./ Q
1/8"
I
J
0
REVISION
W
Qo
�
t
W
OC
W
A
J
L
OJ_aa
i
a
■ F
O
m
o
WW
W
I
Fm
a
J
®
LL
x
O V
3
a
W cc
m
N
d./ Q
O
0)
id
n
i
MIX,
�.
47.
J'^ Off`
J
0
REVISION
W
Qo
No.
I-
a
cc
Z
OC
W
A
J
L
1 -18 -08
iW-
2
(4
2
Z
I-
I
Q
W
V
Z
Q
�
Q
W
Z
3
N
0)
N
m
a
0
0)
JOB No. 0326
CAD FILE: GUS
DATE: 12 -29 -03
sm
REVISION
No.
DESCRIPTION
DATE:
2
AS BUILT
1 -18 -08
JOB No. 0326
CAD FILE: GUS
DATE: 12 -29 -03
sm