Loading...
6700 SW 67 ST ERPB-08-042-001 W BID W ]KK GOT V NU LO m N 1rL. 0 10 20 Nti..... SCALE 1„ = 20' tk p.: 61 NT, N�' 1'L' i ,yN p,0 12 -- — R=25.00' L=39.15 Oro Tah=24.88' 6' inciana 0'-1' A.89'42'59 z.,1 P inciana Palm* 3' 30'-3' o.5'-to'-15' NEW SIDEWALK 6700 SW 67 STREET a� OWNER: JOSE E GONZALEZ ,� •�� Tree .•�� �xxo+�ee�y�� r� 2' 30'-30' m (� C_on 0 ca l z J 0� '�.Y xR� • 9 O 0 t O Palm *0.5-10'-15' CO_ i z m n o i Z I In N 0 - - Poinciana � "- V-40'-S'K,, Poinciana -40 3' ._.. .. f `^ Tree V-10,-10"-, 0 6 � I LEGEND .f = ELEVATION LOCATION MAP DRwY. = DRIVEWAY U.P. = UTILITY POLE SCALE 1":300' D.O.B. = BASIS OF BEARINGS A/C =AIR CONDITIONING PAD NORTHEAST 114, SOUTHEAST 114 SECTION 28, A = ARC DISTANCE TOWNSHIP 54 SOUTH,RANGE 40 EAST BLDG. = BUILDING C.B. = CATCH BASIN MIAMI-DADE COUNTY FLORIDA C.B.S. = CONCRETE BLOCK STRUCTURE CH. = CHORD DISTANCE C = CALCULATED (C) = CLEAR CL = CENTER LINE CONC. = CONCRETE P.R.0 = POINT OF REVERSE CURVE DEVELOPMENT INFORMATION: P.C. = POINT OF cuRVATURE F.N.D. = FOUND NAIL/DISK 1. CURRENT ZONING: RS-1 P.C.C. = POINT of COMPOUND CURVE M/L = MONUMENT LINE 2, NUMBER OF LOTS: 1 N.G.V.D. = NATIONAL GEODETIC VERTICAL DATUM 3. NUMBER OF BLOCKS: 1 O.E. = OVERHEAD ELECTRIC LINE 4. POTABLE WATER: WASD P.B. = PAT eooK P.C.P. = PERMANENT CONTROL POINT 5. Flood Criteria: 8.D feet P.G. = PAGE P.O.B. – POINT OF BEGINNING NOTES P/L = PROPERTY LINE 2,LEGAL DESCRIPTION: N.T.S. = NOT TO SCALE Parcel2 = CENTRAL ANGLE ® = CATCH BASIN Tract 1, less the West 159 feet, of "NELSON HOMESITES°, according to = SANITARY SEWER the Plat thereof, as recorded in Plat Book 39, at Page 57, of the = WATER VALVE Public Records of Miami-Dade County, Florida. 13 Oak L.F_F.E. = LOWEST FINISH Containing 49,188 square feet (1.13 Acres) more or less by Poinciana N 20'-10 : FLOOR ELEVATION calculations. 0.5'-20' ! S.I.R. = SET IRON Roo Oak OCIk P.O.C. =POINT OF COMMEN–CEMENT Property Address: 6700 SW. 67th street, South Miami Florida 33143 10, 101.1 30-20' F.N. = FOUND NAIL P.T. = POINT OF TANGENCY 3.ACCURACY: _ E.N.C_ = ENCROACHMENT —'-- 01-1 m I F.H. = FIRE HYDRANT The accuracy obtained by measurement and calculation of closed :1. 10' 15 1 35.D ;NZ F.I.P. = FOUND IRON PIPE geometric figures was found to exceed this requirement. 5 F.I.R. = FOUND REBAR U brello 6 L.F.E. = LOWEST FLOOR ELEVATION 20'-10 L.P. = LIGHT POLE Q' CI i (M) = MEASURED Dc�' .y^j (R) = RECORD WALLS N� N�6� N� OVERHEAD LINE P.I. = POINT OF INTERSECTION T ON WOOD FENCE Sidewalk to start at existing x— = CHAIN LINK FENCE sidewalk 5' wide and narrow = C.B.S. WALL to 4' wide where oak trees R = BLOCK CORNER R = RADIUS exist, and rethicken to 5' Rao. = RADIAL wide afterward. RES. = RESIDENCE R/W = RIGHT OF WAY where trees are in Way of SEC. = SECTION sidewalk, sidewalk to be S.I.P. = SET IRON PIPE moved 12° from trees as STY - STOW SWK = SIDEWALK shown UE. = UTILITY EASEMENT _Q1 = UTILITY POLE max 2% slope towards = FIRE HYDRANT street,and maximum 12% = METAL LIGHT POLE slope running north and = LIGHT POLE south. = WATER METER existing countour of land = CABLE N Box cannot be respected due to compliance with code.