08-552R-002
FIRE ALARM INSTALLATION & OPERATION NOTES: SCOPE OF WORK: (1. THIS IS A CERTIFICATED CENTRAL STATION FIRE ALARM SYSTEM WITH HORN STROBE NOTIFICATION, 24 HOUR STANBY AND 2 LINE DACT FOR EMERGENCY FORCES } NOTIFICATION. 2. INSTALL NEW EST (QS1) FIRE ALARM CONTROL PANEL, (BPS6A) REMOTE POWER SUPPLY, INITIATING AND NOTIFICATION DEVICES AS SHOWN ON FLOOR PLAN AND RISER DIAGRAM. SYSTEM WILL BE CONNECTED TO BASE BUILDING FIRE ALARM SYSTEM. OCCUPANCY INFORMATION: 2 1. TH S I A NE S M L OCCU A I , N A101 CHAT 2 (2003). 2. THE SIZE OF THIS OCCUPANCY IS APPROXIMATELY 7,320 SQUARE FEET (SINGLE STORY). SEQUENCE OF OPERATION- 1. UPON THE ACTIVATION OF A CEILING SMOKE DETECTOR OR A CEILING HEAT DETECTOR ON ANY LEVEL THE FACP WILL ACTIVATE GENERAL ALARM TURNING ON ALL THE AUDIBLE / VISUAL NOTIFICATION DEVICES ON ALL LEVELS, THE SIGA -CR RELAYS WILL SHUT DOWN ALL AHUS OVER 2000 CFM, CLOSE THE FSD'S ON ALL LEVELS AND DE- ENERGIZE ALL MAGLOCKS. THE FACP AND ANNUNCIATOR WILL DISPLAY THE ALARM LOCATION ILLUMINATE THE ALARM LED AND THE DIALER WILL CALL THE LISTED CENTRAL STATION THAT WILL DISPATCH EMERGENCY FORCES. 2. UPON THE ACTIVATION OF A MANUAL PULL STATION ON ANY LEVEL THE FACP WILL ACTIVATE GENERAL ALARM TURNING ON ALL THE AUDIBLE / VISUAL NOTIFICATION DEVICES ON ALL LEVELS, CONTROL RELAYS WILL SHUT DOWN ALL AHUS OVER 2000 CFM, CLOSE THE FSD'S ON ALL LEVELS AND DE- ENERGIZE ALL MAGLOCKS. THE FACP AND ANNUNCIATOR WILL DISPLAY THE ALARM LOCATION ILLUMINATE THE ALARM LED AND THE DIALER WILL CALL THE LISTED CENTRAL STATION THAT WILL DISPATCH EMERGENCY FORCES. 3. UPON THE ACTIVATION OF THE ALARM SILENCE SWITCH AT THE FACP ALL AUDIBLE / VISUAL NOTIFICATION DEVICES ON ALL LEVELS WILL TURN OFF. ANY NEW ALARMS DETECTED AFTER THE NOTIFICATION DEVICES HAVE BEEN SILENCED WILL REACTIVATE THE AUDIBLE / VISUAL DEVICES ON ALL LEVELS. SPRINKLER WATER FLOW ALARMS CANNOT BE SILENCED UNTIL THE WATER FLOW IS SHUT OFF. 4. THE FACP WILL MONITOR THE SYSTEM FOR REMOVED DEVICES, OPEN FIELD WIRING, GROUNDS ON SYSTEM WIRING, AC POWER FAILURE, LOW BATTERY VOLTAGE AND PHONE LINES 1 & 2 TROIUBLE. ALL SYSTEM TROUBLES WILL INDICATE A ALARM AT THE FACP. THE DIALER WILL CALL THE LISTED CENTRAL STATION THAT WILL DISPATCH THE ALARM ttBUILDING MPANY. UPAN CY IS FULLY SPRINKLED AND MONITORED BY BASE CP. POWER SUPPLY OPERATION: 1. EACH REMOTE NOTIFICATION POWER SUPPLY WILL ANNUNCIATE ONLY ONE SYSTEM TROUBLE MESSAGE AT THE FACP FOR THE FOLLOWING ABNORMAL CONDITIONS; REMOVED DEVICES OR OPEN WIRING FOR ARE SERVED AC POWER LOSS, BATTERY TROUBLE AND GROUND FAULT. WHEN A REMOTE POWER SUPPLY TROUBLE IS DISPLAYED AT THE FACP THE RESPONDING PERSONAL MUST USE THE LED INDICATORS AT THE REMOTE POWER SUPPLIES TO DETERMINE THE SPECIFIC TROUBLE CONDITION. PS SIGNALING WILL NOT PROVIDE INDIVIDUAL TROUBLE ANNUNCIATION AT THE FACP. INSTALLATION NOTES: 1. THIS IS A COMPLETE NEW POWER LIMITED ADDRESSABLE FIRE ALARM SYSTEM. 2. THIS IS A CERTIFICATED CENTRAL STATION SERVICE SYSTEM WITH 24 HOUR STAND -BY BATTERIES. 3. LOCATE ALL CEILING TYPE DETECTORS AT LEAST T AWAY FROM ALL AC DIFFUSERS AND DOORS. 4. THE MANUAL PULL STATIONS WILL BE INSTALLED AT 48" FROM THE FLOOR TO CENTER OF THE DEVICE. 5. THE AUDIBLE / VISUAL NOTIFICATION APPLIANCES IN ALL AREAS WILL BE INSTALLED AT 80" FROM THE FLOOR TO THE BOTTOM OF DEVICE. ALL VISUAL DEVICES ARE SYNCHRONIZED AND THE AUDIBLE SIGNAL IS TEMPORAL PATTERN ALSO SYNCHRONIZED. 6. ALL MONITOR MODULES ARE TO BE INSTALLED WITHIN 3' OF THE POINTS, VALVES OR EQUIPMENT BEING MONITORED. SOME EXCEPTIONS APPLY i.e., PIV, BACK FLOW, ETC. 7. THE FACILITY OWNER MUST PROVIDE TWO DEDICATED PHONE LINES TO THE FACP. 8. ALL EQUIPMENT IS COMPATIBLE AND UL LISTED FOR FIRE ALARM SYSTEM USE. 9. PROVIDE BREAKER LOCKS FOR ALL FIRE ALARM CIRCUITS AND PAINT BREAKERS RED. 3 10. PAINT ALL FIRE ALARM JUNCTION BOX COVERS RED. 11. THE ROOM CONTAINING THE FIRE ALARM CONTROL PANELAND POWER SUPPLY PANEL IS MECHANICALLY VENTILATED. p� 7 Q0r zj� L Z ►AEI FIRE ALARM LEGEND COUNT SYMBOL DEVICE TYPE MODEL MANUFACTURE VOLTAGE DROP CALCULATIONS FACE' FIRE ALARM CONTROL PANEL QS1 E.S.T -fk I ��11111l1���' i 1 HIS (75cd) REMOTE ANNUNCIATOR PANEL H/S (110cd) 1/8 1 STR (110cd) WP STR (110cd) STR (75cd) MINI HORN HORN / STROBE TOTAL Lengtt JIT (mA) STROBE ONLY QTY Sub -Tot (mA) 1.68 AH QTY Sub -Tot (mA) CS405 -8A -T JQTY Sub -Tot (mA) MANUAL PULL STATION QTY Sub -Tot (mA) a QTY Sub -Tot (mA) 1 QTY Sub -Tot (mA) (feet) 1 281 x 2 562 0 x 0 0 329 x 1 329 4 x 0 0 255 x 2 510 0 X1 0 0 1.401 106 281 x 3 843 0 x 0 0 0 x 0 0 x 0 0 255 x 2 510 0 x 0 0 1.353 118 0 x 0 0 0 x 0 0 0 x 0 0 x 0 0 x 0 0 0 x 0 0 0.000 0 0 x 0 1 0 1 0 x 0 1 0 0 x 0 0 x 0 0 x 0 0 0 x 0 0 0.000 0 zj� L Z ►AEI FIRE ALARM LEGEND COUNT SYMBOL DEVICE TYPE MODEL MANUFACTURE 1 FACE' FIRE ALARM CONTROL PANEL QS1 E.S.T -fk I ��11111l1���' i 1 FAAP REMOTE ANNUNCIATOR PANEL SRA E.S.T 1/8 1 P/S REMOTE POWER SUPPLY BPS6A �E.S.T� 5 ® HORN / STROBE G1RF -HDVM E.S.T 4 ® STROBE ONLY G1RF -VM E.S.T 1 1.68 AH ©STROBE ONLY WEATHERPROOF CS405 -8A -T E.S.T 3 ❑ MANUAL PULL STATION SIGA -278 E.S.T 4 a SIGNAL INPUT MODULE SIGA -CT1 E.S.T 1 O SMOKE DETECTOR SIGA -PS E.S.T 1 ® RELAY MODULE SIGA -CR E.S.T 4 ® REMOTE TEST STATION SIGA -TRM E.S.T 4 DUCT DETECTOR SIGA -SD E.S.T 30 TOTAL DEVICES FIRE ALARM WIRE LEGEND WIRE SYMBOL WIRE TYPE - - - - - (A) INITIATING (14 -2 T.H.H.N. - FPLP OR FPLR) 190 mA (B) SIGNAL (2# 14 T.H.H.N. - FPLP OR FPLR) DEVICES x (C) 24V POWER (2# 14 T.H.H.N. - FPLP OR FPLR) CEILING __7 . '� SMOKE DETECTOR MINIMUM DISTANCE A/C DEFUSER AND/ OR T AWAY FROM DUCT FLOUORECENT LIGHT SMOKE DETECTOR MOUNTING DETAIL NOTE: DO NOT INSTALL A SMOKE DETECTOR IN DIRECT AIRFLOW DUCT NOTE: THE SPRINKLER SYSTEM IS MONITORED BY THE BASE BUILDING FACP. DEVICE NUMBER CURRENT PER DEVICE STANDBY ALARM BPS6A 70 mA 190 mA NOTIFICATION DEVICES x H/S 5 161 mA -fk I ��11111l1���' i 0 mA 805 mA STR75 4 152 mA 1/8 0 mA 608 mA STR110 WP 1 248 mA 0 mA 248 mA TOT. CURR. RATINGS ALL DEV. line A,B,C 70 mA 1851 mA TOTAL CURR. CONVERTED TO AMPS 0.001 0.07 A 1.851 A NUMBER OF STANDBY HOURS (24 for NFPA) 24 Hr Multiply lines E & F Total standby AH 1.68 AH ALARM SOUNDING PERIOD /HOURS 5 MIN= .0833 HRS 0.0833 Hr MULTIPLY LINES E & H 0.154188 AH ADD LINES G & 1 1.834188 AH 7 A/H PROVIDED MULTIPLY LINE J BY 1.20 (20% EXTRA FOR DESIRED PERFORMANCE (1.2 Derating Factor) 2.201026 AH O cn w w m m M_ M E _ ii m ELEC. RM. S1 _r 1„ JkR R 7 1.1.1 75cd 1.2.1 75cd 1.2.2 RR 3 THIS OCCUPANCY IS FULLY SPRINKLED. M01 75cd 1. DINING AREA 80" A.F.F. OR 6" BELOW CEILING (WHICHEVER IS LOWER) U -/' STROBE OR HORN /STROBE F O R O E p �. �1 'a �y11 A °' 1. PRE -RATED CONCRETE FLOORS OR BLOCK WALLS = MIN. 4 -1/2" THICKNESS. L" ,- 2. MAX. AREA OF OPENING= 288 SQ. IN., WITH A MAX. DIMENSION OF 24 ". METALLIC PIPE - A) STEEL PIPE - 8- DIAM. (OR SMALLER) SCH. 40 (OR HEAVIER) STEEL PIPE. B) CONDUIT - 4" DIAM. (OR SMALLER) EMT OR 6" DIAM. (OR SMALLER) STEEL CONDUIT. C) IRON PIPE - 8" DIAM. (OR SMALLER) CAST OR DUCTILE IRON PIPE. PULL STATION p D) COPPER TUBING - 4" DIAM. (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. 48" A.F.F. O E) COPPER PIPE - 4" DIAM. (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. o EPARFMENl (VjIA1�J[T-�A�E Co. �� FIRE i NOTE: THE MAXIMUM NUMBER OF PIPES WITHIN OPENING IS 3. A_gPPLICK"O"q THE ANNUNLAR SPACE BETWEEN PIPES SHALL BE MIN. 1 -1/2" AND A MIN. 1/2" BETWEEN PIPES AND EDGE OF OPENING. ADA HEIGHT REQUIRMENTS�� `�,,� I� F ��: 3. FORMING MATERIAL (NOT SHOWN, OPTIONAL) - NOM. 1" THICK POLYURETHANE BACKER. N.T.S. I f ; . ! u I , :., € ",4. FYRE- SHIELD - MIN. 1/2" THICKNESS MASTIC APPLIED WITHIN ANNULUS, FLUSH WITH 1'. E I ri � � .. C? / °+ t , l •; +,,; i_,f :.? i �e E d 'i' : ti : r.. •,.+ Le . �: -I ' TOP SURFACE OF FLOOR OR WITH BOTH SURFACES OF THE WALL ASSEMBLY. 1 , . fl. ��. .-r. �.i i':I.1 L.wf. ": ".117 Ott l.�•�.� FI:aE AT�v�i:ri TISTENI TO BE FIRE ALARM SHALL BE A CENTRAL INSTALLEORJFiCCORDANCEWITH STi,+T1011 SEEVICE. A CERTIFICATE CR PU,C /`RD SHALL BE POSTED AT NFPA 72; 70;101 - A'- �, ^ • , �, Fi ;,'A_ 1'�"": -._CT,O 1%', r E R P4 PA 72 C1 D07 C• ti 3RD 75cd FLOOR R 1.1.2 D05 75cd 1.2.4 ri) D06 LSUPPRESSION SYSTEM r ^� - ms s I "' F M02 WP 75cd 110.3 KITCHEN 1.1.4 1.1.3 91""Q HDI ING A EA EOL -2 , FIRE PENETRATION DETAIL U.L. SYSTEM # F -C -1149 75cd 1.1.5 R EOL -1 M04: 1.401A I I r FIRE ALARM RISER DIAGRAM 1.2.3 1.2.4 1.2.5 ALL CIRCUITS ARE CLASS 'IT 1.2.1 1.2.2 75cd 75cd 75cd 75cd 75cd 1.521A 1.1.4 1.1.5 1.1.1 1.1.2 1.1.3 75cd 75cd (1 B) 75cd 75cd 110cd EOL -1 0 1.401A i 1 C WP / 1 1A TO BASE BLDG. FACP: } 1A M '-' `-' INTERCONNECT FIRE ALARM CONTROL M137 M138 M139 ) PS1 P2 P1 PANEL TO FUCTION AS AS A SINGLE C) ALARM SUPERVISORY TROUBLE SYSTEM. FAAP P/S S( RA) FACP 3 BPS6A ( (QS1) 2 (1A) D01 D05 D06 D07 D08 M02 M03 M04 M05 M01 _ z 2� 1 RT RT R R FIRE AC UNITS G` - tTHHN SUPPRESSION SHUT M01 1 #12 RT1 RT2 RT3 RT4 SYSTEM DOWN THHN L - -- 1AJ DEDICATED 120V (3) (# 12 T.H.H.N.) PHONE LINES 120V (3) (# 12 T.H.H.N.) CIRCUIT #22 CIRCUIT #24 3 THIS OCCUPANCY IS FULLY SPRINKLED. 3 BASE BUILDING FACP AREA OF WORK KEY PLAN N.T.S. n 4fn .p, sC C� ma .Dim. P N r CD g» L]2N a w> in n 2r�mn �.MaN� w ui, 7 In P) mr w� v Ix- 6:11 m h M Wco J co �g N �Q %x CO Np H y REVISIONS: CITY COMMENTS (04/23/08) A2 BUILT ADDRESSED BY: N.C. (08/27/08) AS BUILT PER FIRE DEPARMENT ADDRESSED BY N.C. (10/07/08) LICEVSED ENGINEER: ANTI LAL pATEL (954) 327 -9475 P.E.OQ28,�§j ir1t/, FIRE�Fp TEGTIP �.• e<, . '� .• U �� 0 .a a -fk I ��11111l1���' i F- NUMBER: F -00334 DATE: SCALE: 10/26/07 • 1/8 DRAWN BY: CHECKED BY: D.A.L. B.Pr _ OF r.'I I