A. ALL WORK SHALL BE DONE in accordance with the Florida
Building Code 2004 and with all applicable regulations.
B. DRAWINGS: Refer to all drawings for coordination of the
plumbing work.
C. ARRANGE AND PAY for oil permits, licenses, inspections
and tests. Obtain the required certificates and present
to owner.
D. GUARANTEE: The completed Installation shall be fully
guaranteed against defective moteriols and /or improper
workmanship for a minimum of one year for material and
labor.
E. ALL HORIZONTAL SANITARY PIPING 2' or smaller shall slope at
1/4" per foot minimum, 3" or larger shall slope at a
1/8" per foot minimum.
SHOP DRAWINGS. Contractor shall submit for approval, within
30 days of signing contract. a minimum of five copies of fully
descriptive literature, including but not limited to: water
heaters, drains, piping and plumbing fixtures. No work shag proceed
without the approval of these submittals.
PLUMBING FIXTURES: Fixtures shall be as specified and shall be
furnished and installed by the contractor. Fixtures shall be
complete with drains. traps, supplies and any other accessory
required.
MATERIALS:
A. PIPING:
a. Soil, waste and vent, and storm: Sanitary pipe PVC,
DWV, Schedule 40. In case of air cond. plenumm enclosures
cast iron sanitary pipes shall be used.
b. Domestic water. Copper pipe, Type L with sweat wrought
copper fittings. Type "M" in concealed spaces is
acceptable. Isolate piping from concrete with insulating
material. CPVC in apartments water distribution is
acceptable as per owners request.
c. Condensate drain: DWC PVC, except use DWV Copper pipe and
fittings in a/c dosets.
d. Domestic water supply assembly. Chrome finish tubing
With ongle shut off valves.
B. DRAINS: See plumbing fixture schedule.
C. ALL AUTOMATIC ELECTRIC water heaters shall to meet the
standards of the latest energy efficiency code.
5. PIPING TEST AND DISINFECTION&
A. Test: All sanitary, grease waste and domestic water supply piping shall
be tested for leaks before piping is concealed or connected
to equipment and plumbing fixtures.
B. Disinfection: All domestic water piping shall be
disinfected by introducing a solution of calcium
hypochlorite of 50 parts per million of chloride and as
per AWWA Standards.
6. VALVES: Domestic water valves shall be of bronze body.
sweat ends.
7. CONTRACTOR SHALL COORDINATE exact location of Sanitary, Vent, Condensate
and Domestic Water piping before starting any work Notify
Architect/Engineer of any deviations from design drawings.
8. SAW OR CUT CORE DRILL slab as required to instoll new plumbing
work. Patch slab to match existing and seal all penetrations
to maintain fire rating of floor.
9. CONTRACTOR shall provide all neccessary accessories and materials
for a complete kitchen equipment installation. Consult with the
kitchen consultant's drawings for requirements.
10. CONTRACTOR SHALL CONSULT with all equipment suppliers for
any accessories necessary to achieve o complete installation.
11. All installations shag meet the standards of the local authority and
health department.
12. The Plumbing Contractor shall be ResponsNe for permitting and
installed all Traps and Interceotors /Separators.
13. All traps/ Interceptor /Seporotor Shall be Accessible for maintenance,
cleaning and Replacement.
14. Interceptor /Separator. Shall conform to PDI G101 and shall be installed in
accordance with the manufoctures Instructions.
FIXTURE CONNECTION SCHEDULE
PLUMBING SYMBOL LEGEND
SYMBOL
DESCRIPTION
COLD
WATER
SANITARY LINE
REMARKS
VENT LINE
WATER CLOSET TANK
FLOOR TYPE H.C.
COLD WATER UNE
1 /2'
HOT WATER UNE
FIXTURES AS SPECIFIED
BY ARCH / OWNER
EXISTING SANITARY PIPE
LAVATORY WALL H.C.
EXISTING COL) WATER UNE
—
EXISTING VENT UNE
-�- —�
SAFEWASTE UNE
MOP. SINK
GATE VALVE
$.p
BACKFLOW PREVENTOR
B A EECI IED
FLOOR PENETRATION
FD
FLOOR DRAIN
- --
WATER HAMMER ARRESTOR
PRECISION PRODUCTS PR -500
ON FLOOR
WCO
WALL CLEANOUT
VTR
VENT THRU ROOF
COOG
CLEANOUT ON GRADE
A.A.V.
AIR ADMITTANCE VALVE
TIE -IN TO EXISTING PIPE
FIELD COORD. BEFORE STARTING WORK
WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET
FLOOR SINK
f ±�
FLOOR DRAIN
FIXTURE CONNECTION SCHEDULE
MARK
DESCRIPTION
WASTE
COLD
WATER
HOT
WATER
REMARKS
P -1
WATER CLOSET TANK
FLOOR TYPE H.C.
3 "
1 /2'
- --
FIXTURES AS SPECIFIED
BY ARCH / OWNER
P -2
LAVATORY WALL H.C.
1 1/2"
1/2"
1/2-
FIXTURES AS SPECIFIED
BY ARCH / OWNER
P -3
MOP. SINK
3"
1/2-
1/2-
B A EECI IED
TP
TRAP PRIMER
- --
- --
1/2'
PRECISION PRODUCTS PR -500
ON FLOOR
NOTES:
1. ALL FIXTURE AND FAUCETS SHALL COMPLY WITH THE FBC WATER CONSERVATION
REQUIREMENTS.
LAVATORY WASTE
LAVATORY
//I,—
IROME PLATED
IPPLY (SPEED WAY
Z EQUAL)
OME PLATED
UTCHEON
LINE MUST
PE TO TRAP
"OR DRAIN
FLOOR DRAIN
TRAP RESEAL DETAIL N.T.S.
SH FLOOR
PRIMER
i
DRAIN SCHEDULE
SHOCK ARRESTOR SCHEDULE
DESCRIPTION
P.D.I. DESIGNATION
MANUF. & MODEL
FIXTURE UNITS
CONNECTION
A
SIOUX CHIEF 652 -A
1 -11
- JOSAM 30003 -5S
PROVIDE TRAP PRIMER.
1/2"
B
SIOUX CHIEF 653 -B
12 -32
-JOSAM 32120 -2 -50
PROVIDE TRAP PRIMER do BUCKET
3/4"
C
SIOUX CHIEF 654 -C
33 -60
- JOSAM 49300 -3
WITH 1/2 GRATE:
1"
SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO
ACCESS DOOR REQUIRED. CONFORMS TO ANSI /ASSE 1010 STANDARDS.
IROME PLATED
IPPLY (SPEED WAY
Z EQUAL)
OME PLATED
UTCHEON
LINE MUST
PE TO TRAP
"OR DRAIN
FLOOR DRAIN
TRAP RESEAL DETAIL N.T.S.
SH FLOOR
PRIMER
i
DRAIN SCHEDULE
NO.
DESCRIPTION
DRAIN
CW
REMARKS
FD
FLOOR DRAIN
TOILET ROOMS
3'
112"
- JOSAM 30003 -5S
PROVIDE TRAP PRIMER.
FD -1
FLOOR DRAIN
4'
11Y
-JOSAM 32120 -2 -50
PROVIDE TRAP PRIMER do BUCKET
FD -2
FLOOR SINK
(SAFE WASTE)
3'
-
- JOSAM 49300 -3
WITH 1/2 GRATE:
PROVIDE CLEANOUT TEE
WITH SCREWED COUNTER - I I
PARTITION
AS SAN
ROUND SECURED GASKETED NICKEL BRONZE ADJUSTABLE
TOP WITH 'CO' CAST IN COVER. PROVIDE CLEANOUT TOP
FIXTURES
1- THREE COMPARTMENT SINK
(24" X24'X12') X 2= 13,824 CUBIC INCHES
CUBIC INCHES 13824 = 60 GALLONS
231 231
60 X 75% = 45 GALLONS
J= 23 GPM
USE 50 GPM FLOW RATE. SIZE BASED FOR TABLE 1003.4.1
CHARTER 10 AS PER F.B.C. -2004
TOTAL -FLOW TRHOUGH RATING = 25 GPM
GREASE RETENTION CAPACITY = 50 POUNDS
AS PER MANUFACTURE RECOMMENDATION. EOUAL ZURN 1170
3" INLET
G = WIDTH OF BODY 3" OUTLET
GREASE INTERCEPTOR #1 DETAIL
NTS
DIMENSIONS (IN.):
C--- - -15.,
D /E --- 11 3/4"
F-- - - -30"
G- - - - -17 1/4"
SIZE - -- -500
KEYNOTES -- -- -----
II
10LOCUS
l 011TRCTURN
I MOOR PORATIO
500 South Dixie Highway, Suite 310
Coral Gables, Florida 33146
Tel (305) 74MI20
Fax (305) 740-0520
License No. AA0002733
CONSULTANT(S)
T (F Consulting Engineers, Inc.
CA 26441
MECHANICAL - PLUMBING - ELECTRICAL
9520 s w. 4o sT. BUTTE 207 - MUUN FLORIDA 33185
OFFICE (305) 225.8377 - FAX (305) 225 -8378
EMAIL TFENOINEERSQ13ELLSOUTH.NET
NO. REVISION /SUBMISSION DATE
SPECIAL USE PLANNINGI2 -14 -07
BOARD REVIEW
PERMIT SET 02 -20 -08
PROJECT
Interior Plan for:
CAVAS WINE CAFE
SOUTH MIAMI MUNICIPAL GARAGE
5829 SW 73rd Street, Units #7-8
South Miami, Florida 33143
DRAWING
Notes, Schedules and
Plumbing Details
SEAL 131 SCALE
Nistor J. 'Cifue
PE # 25t' t p►W J? '
..(c, ••
w
ry
Signature
o.
Date It
1
SHEET NO.
P111111113
-a,
1
PIPE MAY EXTEND
I
AS WASTE OR VENT. — '
COLUMN OR
PROVIDE CLEANOUT TEE
WITH SCREWED COUNTER - I I
PARTITION
AS SAN
ROUND SECURED GASKETED NICKEL BRONZE ADJUSTABLE
TOP WITH 'CO' CAST IN COVER. PROVIDE CLEANOUT TOP
"HOT "" VALVE
FAUCET FLOW CONTROL Z_ COLD VALVE
SUNK ABS PLASTIC PLUG,
ON FLOOR
WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET
(�•)
TAPERED - THREAD WITH
PL AN.
MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED
VENT
TFE JOINT COMPOUND.
FLOORS). PROVIDE GASKETED PLASTIC PLUG IN CAST IRON
WHERE CLEANOUT TEE
CLEANOUT
BODY. USE TEFLON JOINT COMPOUND ON PLUG THREADS.
IS CONCEALED IN A
FACE SHALL
CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION.
CHASE OR PARTITION,
PROVIDE A ROUND 18 I
BE WITHIN
4' OF WALL
MEMBRANE CLAMP FCO FLOOR SLAB ON GRADE
SINK
GAUGE STAINLESS STEEL ' 1
COVER WITH BEVELED
PROVIDE
- °
- -
To
E DGES AND FLATHEAD I I
MACHINE SCREW.
EXTENSION
IF REQUIRED.
_
AS REQUIRED FOR SAME SIZE AS SEWER
FOR SPEC.
DEPTH OF SEWER UP TO 4' MAXIMUM.
• a. 4
HUB AND SPIGOT LONG SWEEP ELBOW AT
CAST IRON PIPE: END OR TURN OF RUN.
CONCRETE HUB AT FLOOR
REFER TO PLUMBING
BELOW FLOOR.
COMBINATION WYE AND
CO
FLOOR RISER LENGTH
FIXTURE SCHEDULE
SANITARY OR STORM EIGHTH BEND IN RUN.
GREASE INTERCEPTOR
SLAB. AS REQUIRED
FOR FURTHER
SEWER LINE ENTER TOP OF PIPE.
ZURN 1170
LONG SWEEP AT END OF LINE
OR COMBINATION WYE AN
INFORMATION. WCO
DIRECTION
�'— DI FLOW
FLOOR MOUNTED
AIR GAP
FLOOR
EIGHTH BEND IN
DIRECTION
LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS
SINK
RUN OF LINE. I
II -110•—
OF PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS
OF FLOW
ON STRAIGHT RUNS, AND /OR WHERE SHOWN ON PLANS.
SLAB
_
PROVIDE BACK FILL PER ARCHITECTURAL SPECIFICATIONS.
PROVIDE WCO WHERE SHOWN ON PLAN,
AND ON SANITARY
LOCATE CLEANOUTS WHERE THERE IS 18' CLEAR AROUND.
WASTE BRANCHES NOT SERVED WITH A
FLOOR CLEANOUT:
CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS.
TO SEWER UNE
LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4' OF FLOOR.
NOTE: SINK IS FOR DISHWASHING
ONLY
CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS.
-I
WALL CLEANOUT
2
FLOOR CLEANOUT
3
CREASE INTERCEPTOR CONNECTION
DIAGRAM
NOT
TO SCALE
NOT TO
SCALE
NOT TO SCALE
FLOOR GRATE TO BE
DRAIN LINE
PERFORATED CAP —��
FASTENED DOWN WITH
SCREWS
HOT WATER
SUPPLY
-
CLEAN OUT
MOUNT FLUSH
COL) WATER
WITH FINISHED
SUPPLY
DRAIN PAN
FLOOR
TANKLESS
00
ELECTRIC WATER
AIR GAP = 2 X "D"
( 2" MIN. )
HEATER
PITCH DOWN
18" MIN
TOWARD DRAIN
a
•
• • J -BOX
Q
•
•
Q
F
�
4" MIN
'
MAW ELECTRIC WATER HEATER DETAIL 01-1-1)
N.T.S.
NOTE:
MAKER: NIAGARA INDUSTRIES, INC
DRAIN UNE
SHALL BE AT LEAST THE
HUB OUTLET
MODEL: TITAN N -120
SAME SIZE AS THE NIPPLE ON THE
A. FLOOR SINK COVER FLUSH WITH
TILE OR FLUSH
CAPACITY: 0 GALLONS
DRAIN PAN
WITH CONCRETE FLOOR IN AREA
WITH NO TILE
KW INPUT: 11.8
41
FLOOR SINK DETAIL
5
INSTANT WATER HEATER
NOT TO SCALE
NOT TO SCALE
6
TYPICAL
CONDENSATE DRAIN
TRAP
NOT TO SCALE
KEYNOTES -- -- -----
II
10LOCUS
l 011TRCTURN
I MOOR PORATIO
500 South Dixie Highway, Suite 310
Coral Gables, Florida 33146
Tel (305) 74MI20
Fax (305) 740-0520
License No. AA0002733
CONSULTANT(S)
T (F Consulting Engineers, Inc.
CA 26441
MECHANICAL - PLUMBING - ELECTRICAL
9520 s w. 4o sT. BUTTE 207 - MUUN FLORIDA 33185
OFFICE (305) 225.8377 - FAX (305) 225 -8378
EMAIL TFENOINEERSQ13ELLSOUTH.NET
NO. REVISION /SUBMISSION DATE
SPECIAL USE PLANNINGI2 -14 -07
BOARD REVIEW
PERMIT SET 02 -20 -08
PROJECT
Interior Plan for:
CAVAS WINE CAFE
SOUTH MIAMI MUNICIPAL GARAGE
5829 SW 73rd Street, Units #7-8
South Miami, Florida 33143
DRAWING
Notes, Schedules and
Plumbing Details
SEAL 131 SCALE
Nistor J. 'Cifue
PE # 25t' t p►W J? '
..(c, ••
w
ry
Signature
o.
Date It
1
SHEET NO.
P111111113
-a,
1