08-497-0301. A. ALL WORK SHALL BE DONE in accordance with the Florida Budding Code 2004 and with oil applicable regulations. 8. DRAWINGS: Refer to all drawings for coordination of the plumbing work C. ARRANGE AND PAY for all permits, licenses, inspections and tests. Obtain the required certificates and present to owner. D. GUARANTEE. The completed installation shag be fully guaranteed against defective materials and /or improper workmanship for a m'in'imum of one )por for material and labor. E. ALL HORIZONTAL SANITARY PIPING 2" or smaller shall slope at 1/4' per foot minimum, 3' or larger shall slope at a 1/8' per foot minimum. 2. SHOP DRAWINGS. Contractor shall submit for approval, within 30 days of signing contract. a minimum of five copies of fully descriptive literature, including but not limited to water heaters, drains, piping and plumbing fixtures. No work shall proceed without the approval of these submittals. 3. PLUMBING FIXTURES: Fixtures shall be as specified and shall be furnished and installed by the contractor. Fixtures shall be complete with drains, traps, supplies and any other accessory requred. 4. MATERIALS: A. PIPING. o. Soul, waste and vent, and storm: Sanitary pipe PVC, DWV. Schedule 40. In case of air cond. plenumm enclosures cost iron sanitary pipes shop be used. b. Domestic water er pipe, Type L with sweat wrought copper fittings. Type '611" in concealed spaces is acceptable. Isolate piping From concrete with insulating material. CPVC in apartments water distribution is acceptable as per owners request. c. Condensate drain: DWC PVC, except use DWV Copper pipe and fittings in a/c closets. d. Domestic water supply assembly. Chrome finish tubing with angle shut off valves. B. DRAINS: See plumbing fixture schedule. C. ALL AUTOMATIC ELECTRIC water heaters shill to meet the standards of the latest energy efficiency code. 5. PIPING TEST AND DISINFECTION& A. Test: All sanitary, grease waste and domestic water supply piping shall be tested for Woks before piping is concealed or connected to equipment and plumbing fixtures. B. Disinfection. All domestic water piping shall be disinfected by introducing a solution of calcium hypochlorite of 50 pats per million of chloride and as per AWWA Standards. 6. VALVES: Domestic water valves shall be of bronze body, sweat ends. 7. CONTRACTOR SHALL COORDINATE exact location of Sanitary, Vent, Condensate and Domestic Water piping before starting any work. Notify Architect/Engineer of any deviations from design drawings. 8. SAW OR CUT CORE DRILL slab as required to install new plumbing work. Patch slob to match existing and seal all penetrations to maintain fire rating of floor. 9. CONTRACTOR shill provide alt neceessary accessories and materials for a complete kitchen equipment installation. Consult with the kitchen consultant's drawings for requirements. 10. CONTRACTOR SHALL CONSULT with all equipment suppppliers for any accessories necessary to achieve a complete nsfollatwn. 11. All installations sholl meet the standards of the local authority and health department. 12. The Plumbing Contractor shall be Responsible for permitting and installed all Traps and Interceotors /Seporotors. 13. All traps/ Interceptor/Separator Shall be Accessible for maintenance, cleaning and Replacement. 14. Interceptor/Separator. Shall conform to PDI G101 and shall be installed in accordance with the manufactures Instructions. PLUMBING SYMBOL LEGEND � SYMBOL I DESCRIPTION SANITARY LINE — VENT LINE COLD WATER LINE HOT WATER LINE EXISTING SANITARY PIPE EXISTING COLD WATER LINE --- ------ -_ -..- — - -- - -- EXISTING VENT LINE — - —y" SAFEWASTE LINE P -1 GATE VALVE B.P BAOTLOW PREVENTOR - -- FLOOR PENETRATION FD FLOOR DRAIN 1 1/2" WATER HAMMER ARRESTOR WCO WALL CLEANOUT VTR VENT THRU ROOF COOG CLEANOUT ON GRADE A.A.V. AIR ADMITTANCE VALVE TP TIE -IN TO EXISTING PIPE - -- FIELD COORD. BEFORE STARTING WORK 1/2" FLOOR SINK t:+} FLOOR DRAIN FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION WASTE COLD WATER HOT WATER REMARKS P -1 WATER CLOSET TANK FLOOR TYPE H.C. 3* 1/2" - -- FIXTURES AS SPECIFIED BY ARCH / OWNER P -2 LAVATORY WALL H.C. 1 1/2" 1/2* 1/2- FIXTURES ARCH /OWNER ED P -3 MOP. SINK 3" 1/2" 1/2* FIXTURES AS SPECIFIED BY ARCH / OWNER TP TRAP PRIMER - -- - -- 1/2" PRECISION PRODUCTS PR -500 I NOTES: 1. ALL FIXTURE AND FAUCETS SHALL COMPLY WITH THE FBC WATER CONSERVATION REQUIREMENTS. LAVATORY WASTE —•-�- SHOCK ARRESTOR SCHEDULE FP.D.I.GNATION MANUR & MODEL FIXTURE UNITS CONNECTION A SIOUX CHIEF 652 -A 1 -11 1/2" 8 SIOUX CHIEF 653 -8 12 -32 3/4" C SIOUX CHIEF 654-C 33 -60 1* SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO ACCESS DOOR REQUIRED. CONFORMS TO ANSI /ASSE 1010 STANDARDS. PIPE MAY EXTEND AS WASTE OR VENT. ---- I. COLUMN OR PROVIDE CLEANOUT TEE I ( - PARTITION WITH SCREWED COUNTER- ' AS SHOWN SUNK ABS PLASTIC PLUG' ON FLOOR TAPERED - THREAD WITH PLAN,' TFE JOINT COMPOUND. WHERE CLEANOUT TEE CLEANOUT IS CONCEALED IN A FACE SHALL CHASE OR PARTITION, BE WITHIN PROVIDE A ROUND 18 4' OF WALL GAUGE STAINLESS STEEL SURFACE. COVER WITH BEVELED ( PROVIDE EDGES AND FLATHEAD EXTENSION MACHINE SCREW. IF REQUIRED. d CONCRETE �RRISER UB AT FLOOR REFER TO PLUMBING FLOOR LENGTH FIXTURE SCHEDULE SLAB. AS REQUIRED FOR FURTHER INFORMATION. WCO LONG SWEEP AT END OF LINE OR COMBINATION WYE AN EIGHTH BEND IN DIRECTION RUN OF LINE. OF FLOW PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES NOT SERVED WITH A FLOOR CLEANOUT, LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. -� WALL CLEANOUT NOT TO SCALE FLOOR GRATE TO BE DR, FASTENED DOWN WITH SCREWS , n MOUNT FLUSH WITH FINISHED 1 FLOOR , LINE AIR GAP = 2 X "D" (2" MIN.) NOTE: HUB OUTLET A. FLOOR SINK COVER FLUSH WITH TILE OR FLUSH WITH CONCRETE FLOOR IN AREA WITH NO TILE 41 FLOOR SINK DETAIL NOT TO SCALE . C LAVATORY //-- CHROME PLATED SUPPLY (SPEED WAY OR EQUAL) CHROME PLATED ESCUTCHEON FILL LINE MUST SLOPE TO TRAP FLOOR DRAIN FINISH FLOOR TRAP PRIMER FITTING FLOOR DRAIN TRAP RESEAL DETAIL N.T.S. ROUND SECURED GASKETED NICKEL BRONZE ADJUSTABLE TOP WITH 'CO' CAST IN COVER. PROVIDE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). PROVIDE GASKETED PLASTIC PLUG IN CAST IRON BODY. USE TEFLON JOINT COMPOUND ON PLUG THREADS. CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION. MEMBRANE CLAMP FCO FLOOR SLAB ON GRADE AS REQUIRED FOR SAME SIZE AS SEWER DEPTH OF SEWER UP TO 4' MAXIMUM. HUB AND SPIGOT LONG SWEEP ELBOW AT CAST IRON PIPE END OR TURN OF RUN. BELOW FLOOR. -` COMBINATION WYE AND SANITARY OR STORM EIGHTH BEND IN RUN. SEWER LINE ENTER TOP OF PIPE. DIRECTION OF FLOW LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS ON STRAIGHT RUNS, AND /OR WHERE SHOWN ON PLANS. PROVIDE BACK FILL PER ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUTS WHERE THERE IS 18' CLEAR AROUND. CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. 2 1 FLOOR CLEANOUT NOT To scnLe HOT WATER SUPPLY COLD WATE SUPPLY WATER INSTANT ELECTRIC WATER HEATER DETAL 08 -1) N.T.S. MAKER: NIAGARA INDUSTRIES, INC MODEL: TITAN N -120 CAPACITY: 0 GALLONS KW INPUT: 11.8 5 INSTANT WATER HEATER NOT TO SCALE DRAIN SCHEDULE Q DESCRIPTION DRAIN LINE AIR GAP = 2 X "D" (2" MIN.) NOTE: HUB OUTLET A. FLOOR SINK COVER FLUSH WITH TILE OR FLUSH WITH CONCRETE FLOOR IN AREA WITH NO TILE 41 FLOOR SINK DETAIL NOT TO SCALE . C LAVATORY //-- CHROME PLATED SUPPLY (SPEED WAY OR EQUAL) CHROME PLATED ESCUTCHEON FILL LINE MUST SLOPE TO TRAP FLOOR DRAIN FINISH FLOOR TRAP PRIMER FITTING FLOOR DRAIN TRAP RESEAL DETAIL N.T.S. ROUND SECURED GASKETED NICKEL BRONZE ADJUSTABLE TOP WITH 'CO' CAST IN COVER. PROVIDE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). PROVIDE GASKETED PLASTIC PLUG IN CAST IRON BODY. USE TEFLON JOINT COMPOUND ON PLUG THREADS. CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION. MEMBRANE CLAMP FCO FLOOR SLAB ON GRADE AS REQUIRED FOR SAME SIZE AS SEWER DEPTH OF SEWER UP TO 4' MAXIMUM. HUB AND SPIGOT LONG SWEEP ELBOW AT CAST IRON PIPE END OR TURN OF RUN. BELOW FLOOR. -` COMBINATION WYE AND SANITARY OR STORM EIGHTH BEND IN RUN. SEWER LINE ENTER TOP OF PIPE. DIRECTION OF FLOW LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS ON STRAIGHT RUNS, AND /OR WHERE SHOWN ON PLANS. PROVIDE BACK FILL PER ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUTS WHERE THERE IS 18' CLEAR AROUND. CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. 2 1 FLOOR CLEANOUT NOT To scnLe HOT WATER SUPPLY COLD WATE SUPPLY WATER INSTANT ELECTRIC WATER HEATER DETAL 08 -1) N.T.S. MAKER: NIAGARA INDUSTRIES, INC MODEL: TITAN N -120 CAPACITY: 0 GALLONS KW INPUT: 11.8 5 INSTANT WATER HEATER NOT TO SCALE DRAIN SCHEDULE NO. DESCRIPTION DRAIN CW REMARKS FD FLOOR DRAIN TOILET ROOMS 3' 1/2' - JOSAM 30003 -5S PROVIDE TRAP PRIMER. FD -1 FLOOR DRAIN 4' 1/2" -JOSAM 32120 -2 -50 PROVIDE TRAP PRIMER & BUCKET FD -2 FLOOR SINK (SAFE WASTE) 3' - - JOSAM 49300 -3 WITH 1/2 GRATE C SING OF GE EARS. E 141 ERCEP''TOR FIXTURES 1— THREE COMPARTMENT SINK (24'X24"X12 ") X 2= 13,824 CUBIC INCHES C INCHES IN S 13824 a 60 GALLONS 231 231 USE 50 GPM FLOW RATE SIZE BASED FOR TABLE 1003.4.1 60 X 75% - 45 GALLONS CHARTER 10 AS PER F.B.C. -2004 TOTAL -FLOW TRHOUGH RATING - 25 GPM Ajm 23 GPM GREASE RETENTION CAPACITY = 50 POUNDS AS PER MANUFACTURE RELATION. EOUAL ZURN 1170 3" INLET G = WIDTH OF BODY 3" OUTLET GREASE INTERCEPTOR #1 DETAIL NTS "HOT" VALVE FAUCET FLOW CONTROL ZA COLD" VALVE ( ) NOTE: SINK IS FOR DISHWASHING ONLY 3 GREASE INTERCEPTOR CONNECTION NOT TO SCALE PERFORATED CAP PITCH DOWN 18" TOWARD DRAIN r!.94" DIMENSIONS (IN.), C--- - -15., D /E --- 11 3/4" F-- - - -30" G- - - - -17 1/4" SIZE - -- -500 VENT 'SINK REFER TO DETAILS FOR SPED. / ;ILI 1 INTERCEPTOR 1 1170 r TO SEWER LINE SHALL BE AT LEAST THE AS THE NIPPLE ON THE 1 2" 6 1 TYPICAL CONDENSATE DRAIN TRAP � NOT TO SCALE - MIMOCUS MCHITUCTVRN I N C O R P O R A T i 0 500 South Dixie Highway, Suite 310 Coral Giles, Florida 33146 Tel (305) 740 -0120 Fax (305) 740-0520 License No. AA0002733 CONSULT"" i T T ConsuCting Engineers, Inc. CA 26441 j MECHANICAL - PLUMBING - EL ECTAIGL 9520 B.W. 40 8T. 8UITE 207 - MAN FLORIDA 33163 oFr CE MM 2254377 - FAX pas) 225 -8378 ; EMAIL TFENCIINEERBOBELLSOLITKNEr NO. REVISION/SUSFAMSSMON DATE SPECIAL USE PLANNING 12 -14 -07 BOARD REVIEW PERMIT SET 02 -20-08 I I i I i PROJECT Interior Plan for: CAVAS WINE CAFE i I I SOUTH MIAMI MUNICIPAL GARAGE 5829 SW 73rd Sheet, Units #7 -8 South Miami, Florida 33143 i i DRAWING i Notes Schedules and ' i Plumbing Details SEAL SCAB nis ! Nestor J. Clfuentes PE # 2945 DRAWN EP _ REVIEWED TF I sign at w ,J 't .O* , PRO. NO. Da "� " t!� 123 0 -INEET NO. STATE OF �