08-497-024GENERAL NOTES 1. GENERAL A. ALL WORK SHALL be done in accordance with the Florida Building Code and with oil applicable regulations. B. DRAWINGS: Refer to all drawings for coordination of the HVAC work. C. ARRANGE AND PAY for all permits licenses, inspections and tests. Obtain the required certificates and present to owner. D. GUARANTEE: The completed installation shall be fully guaranteed against defective materials and /or improper workmanship for a minimum of one year for material and labor. Compressors shall be guaranteed for a period of five years. 2. SHOP DRAWINGS: Contractors shall submit for approval, within 30 days after signing contract, a minimum of five copies of fully descriptive literature, including but not limited to: air conditioning units, air outlets, controls and fans. No work shall proceed without approval of these submittals. 3. DESIGN PARAMETERS: A. Outdoor design temperature Summer): 91T DB and 797 WB B. Outdoor design temperature Winter): 457 C. Indoor design temperature (Summer): 78T DB D. Indoor design temperature (Winter): 727 DB 4. ALL THERMOSTATS shall have heating mode maximum setting of 75T, and cooling mode minimum setting of 70T. The thermostat shall be arranged to prevent the simultaneous operation of heating and cooling. 5. ELECTRICAL CONTROLS AND POWER WIRING: Under electrical contract. 6. EQUIPMENT SPECIFIED BY manufacturer's number shall include all accessories, controls, etc., listed in the catalog as standard with the equipment. Optional or additional accessories shall be furnished as specified. 7. MATERIALS: A. Refrigerant Piping: Shall be type L soft drawn, copper tubing, dehydrated for refrigerant use. Sizes as shown in drawings or as per air conditioning equipment manufacturer's recommendations. B. Insulation: Refrigerant suction piping shall be insulated with 1/2" thick foamed plastic insulation, fire retardant type. Insulation shall be installed in piping before assembly. No split insulation will be acceptable. Seal joints with manufacturer's approved adhesive and tape. C. Ductwork: a. All supply air ductwork on roof, exhaust air ductwork and outside air ductwork shall be of galvanized sheet metal construction, fabricated and installed as per latest edition of SMACNA Low Pressure Duct Manual. Duct on roof shall be weatherproof with bitumostic sealant and point. b. All "Low pressure duct manual" insulate supply and return air ductwork in concealed spaces with 1 1/2" in thick fiberglass blanket insulation with fog vapor barrier (R -6.0 MIN.) c. All duct dimensions are clear inside dimensions. d. Flexible insulated ductwork with 1 -1/2' thick fiberglass insulation with FRK vapor barrier R -6.0 Min. 8. TEST AND BALANCE: Contractor shall test and balance oil ventilation and air conditioning systems. Submit four (4) copies of Test and Balance Report to Owner for approval. 9. CONTROLS: Air Conditioning System shall be started and stopped thru individual thermostats. Individual thermostat shall stort /stop supply fans and activate cooling/heating systems as selected. 110. COORDINATE all required roof openings with general contractor. 11. PROVIDE U.L LISTED fire or damper where indicated on drawings. Provide duct access doors to access damper blades. Access doors shall be insulated when located in supply ducts. Fire dampers in smoke control system shall have Hi temp fusible links. h2. PROVIDE CEILING /WALL ACCESS DOORS where indicated on drawings and where required to access mechanical equipment. Doors shall be recessed type. fire rated if in fire rated wall or ceiling. As manufactured by Karp model RDW and KATR. 13. CONTRACTOR: to fire protect and seal all openings and pipe penetrations thru fire rated wolls and ceiling. Material and methods of fire rating shall be approved by City Code Product Control. SPLIT AC UNIT SCHEDULE UNIT DESIGNATION FCU -1 FCU -2 AREA SERVED FLOOR PLAN FLOOR PLAN LOCATION CEILING SPACE CEILING SPACE OPERATING WEIGHT, LBS 167 167 DESIGN MANUFACTURER CARRIER CARRIER MODEL NUMBER FA48060 FA4B06O SEER MIN. 10 1 FAN TIP SPEED RPM MAX - -- - -- FAN SPEED, RPM Z 0 TOTAL AIR, CFM 2000 2000 P VENT AIR, CFM SEE SCHEDULE SEE SCHEDULE N EXTERNAL STATIC PRESSURE, IN OF WATER 0.4 0.4 MC FAN MOTOR HP. NON - OVERLOAD) 3/4 3/4 0.05 ELECTRICAL SERVICE AVAILABLE 208/1/60 208/1/60 1281 SHEET NO. DESIGN MANUFACTURER COOK MODEL NUMBER FACE VELOCITY - FPM - -- - -_ YES DESIGN AIR ACROSS COIL, CFM. 2000 2000 GRAN TOTAL CAPACITY, BTU HR 57,570 57,570 CONSTRUCTION TOTAL SENSIBLE CAPACITY. BTU /HR 41,410 41,410 YES ENTERING AIR TEMP., DB WB 80/67 80/67 SOLID STATE SPEED CONTROL NO a THERMOSTAT CONTROL NO FACTORY FABRICATED CURB a: TYPE & THICKNESS CLEANABLE 1 CLEANABLE 1 J QUANTITY AND SIZE 21 1/2 X 19 7/8 21 1/2 X 19 7/8 FACE VELOCITY FPM. MAX. - -- - -- HEAT COIL TYPE ELECTRIC ELECTRIC w ELECTRICAL SERVICE AVAILABLE 208/l/ 60 208/1/60 = 1AUXILIARY ELECTRIC HEAT, KW 7.5 7.5 STAGES & KW PER STAGE 1/7.5 1/7.5 UNIT DESIGNATION CU -1 CU -2 Z TYPE OF FAN PROPELLER PROPELLER NO. OF FANS AND AMPS 1 1/4 1 1/4 0 Z AMBIENT AIR TEMP. 'F DB 95 95 Oi CONDENSING TEMP. 'F OB - -- - -- o NO. OF COMPRESSORS TYPE 1 SCROLL 1 SCROLL Z COMPRESSORS RLA URA 28.9 165 28.9 165 0 CAPACITY REDUCTION. 0 -100 0 -100 0 0 U ELECTRICAL SERVICE AVAILABLE JOPERATING 208/1/60 208/1/60 WEIGHT, LBS I 218 218 a DESIGN MANUFACTURER CARRIER CARRIER MODEL NUMBER 38CKS060 -3 38CKS060 -3 REFRIGERANT LINE SUCTION / LIQUID 1- 1/8 -3/8 1- 1/8 -3/8 NOTE. 1) VERIFY LINE SIZE AS PER MANUFACTURER RECOMENDATIONS 2) ALL FAN COIL UNITS SHALL BE PROVIDED WITH FACTORY INSTALLED CIRCUIT BREAKER. 3) PROVIDE AUXILIARY CONDENSATE FLOAT SWITCH 4) FAN COIL UNITS 1,2 HORIZONTAL. VENTILATION FAN SCHEDULE UNIT DESIGNATION TEF -1 AREA SERVED TOILETS OPERATING WEIGHT LBS. 30 LOCATION GEILING FAN TYPE IN LINE X FIRE RATED ENCLOSURE - TOTAL AIR CFM FIRE RATED ROOF /FLOOR CEILING ASSEMBLY - DRIVE TYPE DIRECT - FAN WHEEL TYPE CENTRIFUGAL _ FAN TIP SPEED RPM MAX - -- - -- FAN SPEED, RPM 1075 CEILING GRILLE TOTAL STATIC PRESSURE, IN. OF H2O 0.5 - -- FAN MOTOR HP NON OVERLOAD 172 WATT'S 0.15 FAN MOTOR STARTER TYPE ATL STARTER FURNISHED BY MC - -- ELECTRICAL SERVICE AVAILABLE 120 -1 -60 0.05 MASONARY OPENING REQUIRED NO r Date 0:) r� �� 1281 SHEET NO. DESIGN MANUFACTURER COOK MODEL NUMBER GN -420 SERVICE SWITCH YES SMOKE DETECTORS U.L. APPROVED NO FIRE DAMPER NO ,n CONSTRUCTION GALVANIZED MUL71BL.ADE BACKDRAFT DAMPER YES BIRDSCREEN NO SOLID STATE SPEED CONTROL NO a THERMOSTAT CONTROL NO FACTORY FABRICATED CURB NO FILTER AND FILTER FRAME NO NOTE: (D INTERLOCK WITH FAN COIL UNIT 1 & 2 RVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR X _ FIRE DAMPER(S) X - SMOKE DAMPER(S) - X FIRE RATED ENCLOSURE - X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY - X FIRE STOPPING - X SMOKE CONTROL _ X AS PER FLORIDA OUTDOOR AIR CALCULATIONS BUILDING CODE 2001 TABLE 403.3 AREA FLOOR PERSONS/ TOTAL CFM / CFM / CFM CFM SYSTEM DESIGNATION AREA t OOO /FT2 PERSONS PERSONS FT2 REQUIRED PROVIDED I DESIGNATION BAR COCKTAIL LOUNGES 1215 100 78 30 - -- � X170• 1170 CEILING GRILLE STORAGE 140 - -- - -- - -- 0.15 20 20 UTILITIES 200 - -- - -- - -- 0.05 10 10 r Date 0:) r� �� 1281 SHEET NO. AC -3 1200 FCU -1 & 2 ' LESS THAN 3 HOUR PEAK OCCUPANCY DURATION (50X). FCU -1 OUTSIDE AIR BALANCE FOR 600 CFM FCU -2 OUTSIDE AIR BALANCE FOR 600 CFM AIR DISTRIBUTION SCHEDULE SYMBOL USE TYPE ACCESORIES DESIGN MANUFACTURER & MODEL Mo. OA SUPPLY AIR SIDE WALL REGISTER O.B.D. TITUS 300 FS OB SUPPLY AIR CEILING DIFFUSER O.B.D. TITUS 250 -AA O SUPPLY AIR CEILING DIFFUSER O.B.D. TITUS TDC -AA 24X24 PANEL OD RETURN AIR CEILING OR WALL GRILLE O.B.D. TITUS 350 FL OE EXHAUST AIR CEILING GRILLE O.B.D. TITUS 350 FL SURFACE MOUNT NOTE: 1. ALL AIR DISTRIBUTION DEVICES SHALL BE ALL ALUMINUM CONSTRUCTION. 2. COORDINATE COLOR FINISH WITH ARCHITECT, WHITE BAKED ENAMEL STANDARD. 3. ARROWS INDICATE DIRECTION OF AIR DISTRIBUTION. G`-„sif.? F -rating = 2 Hr • T -rating = 1 Hr 8-ltd 1D Pre -Rated Concrete Floor of Wall Assembly = Min. 4 1/2' thickness. ® Metallic Pipe - A) Steel Pipe -2" diam. (or smaller) Sch. 10 (or heavier) steel B) Iron Pipe -2" diom. (or smaller) cast or ductile iron pipe. C) Copper Tubing -2" diam. (or smaller) Type K (or heavier) copper tubing. D) Copper Pipe -2" diom. (or smaller) Regular (or heavier) copper pipe. C) Pipe Covering -Nam. 3/4" thick AB/PVC flexible foam insulation. The annular space shall be min. 1/8" to max. 1/4' within the firestop system. (1) TREMstop IA -Min. 1" thickness of sealant applied within opening, flush with the top surface of floor or both surfaces of wall assembly. Additional fill material to be installed such that a min. 1/4" crown is formed around the penetrating item. TWO HOUR RATED WALL AND SLAB PIPING PENETRATION. N.T.S. SECURED TO STRUCTURE SERVICE CONCRETE WITH 3/8" DIA. GALV. CONSULTANT(S) SWITCH SLAB THREADED RODS. 0520 S.W. 40 ST. SUITE 207 - MIAMI FLORIDA 33168 OFFICE (305) 229 -8377 - FAX (303) 225 -8378 EMAIL TFENGINEERS®BELLSOUIKNEr JVO an BOARD REVIEW PERMIT SET 02 -20 -08 PROJECT Interior Plan for: CAVAS WINE CAFE SPRING ISOLATOR 5829 SW 73rd Street, Units #7-8 South Miami, Florida 33143 DRAWING SCHEDULE, NOTES AND DETAILS MECHANICAL SEAL AIR FLOW ADJUSTABLE MOTOR 4" CANVAS HANGER RODS N W /BELT GUARD CONNECTION W/NU TS L I + - HORIZONTAL IN -LINE FAN MOUNTING DETAIL N.T.S. ` „ PROJ.1Q r Date 0:) r� �� CITY OF SOUTH MIAMI BUILDING DEPT. MECHANICAL SECTION APPROVED BY. 3. 4� RATE: F fqf, v v KE"OTFS LOCUS ARCHITUC'TYR! I N C 0 1 P 0 1 A T I D CONSULTANT(S) T T ConsuCting Engineers, Inc. CA 26441 MECHANICAL - PLUMBING - ELECTRICAL 0520 S.W. 40 ST. SUITE 207 - MIAMI FLORIDA 33168 OFFICE (305) 229 -8377 - FAX (303) 225 -8378 EMAIL TFENGINEERS®BELLSOUIKNEr NO. REVISIONISUBMISSION DATE SPECIAL USE PLANNING12 -14 -07 BOARD REVIEW PERMIT SET 02 -20 -08 PROJECT Interior Plan for: CAVAS WINE CAFE SOUTH MIAMI MUNICIPAL GARAGE 5829 SW 73rd Street, Units #7-8 South Miami, Florida 33143 DRAWING SCHEDULE, NOTES AND DETAILS MECHANICAL SEAL SCALE Nestor J. Cifuen PE # 294 N ci L I + - T a:. - Signature ' ' ` „ PROJ.1Q r Date 0:) r� �� 1281 SHEET NO. AC -3 �3 1