Loading...
08-497-023SUPPORT FROM UNDERSIDE PAIR AT OF STRUCTURE. PAIR AT PAIR AT ROUND SPIN IN BELL MOUTH 1 1/2" X 22 GA. GALV. MOUNT IN SIDE OF DUCT STEEL HANGER STRAP UNLESS SPECIFICALLY (5' O.C.) SHOWN OTHERWISE. FLEXIBLE DUCT ADJUSTABLE CLAMP WITH R/D = 1.0 16 MAXIMUM D/8 OFFSET MAX. SAG 1/2- PER FOOT ALLOWED IN LAST BETWEEN SUPPORT POINTS D INCHES TO DEVICE ROD WHERE D IS THE ROD STRAP INTERNAL FLEX STRAP ROD DIAMETER. \ DUCT SEALER AT SPIN COLLAR CONNECTION TO MAIN. SUPPLY DUCT SIZE AS SHOWN ON PLANS NECK SIZE TO TRAP MATCH FLEX ADJUSTABLE CLAMP INSULATION SEE PLANS DUCT SIZE OR SPECS FOR VALUE INDICATED. DUCT SEALER VOLUME DAMPER WITH LOCKING INSULATE TOP PANEL OF LAY -IN QUADRANT AND 2" STANDOFF DIFFUSER WHERE REQ'D. SEAL INSULATION TO DIFFUSER -NOT TO T -BAR GRID. CEILING ----' AIR DISTRIBUTION DEVICE, SEE `— CEILING ACCESS PANEL (T -BAR SHOWN. SCHEDULE. (LAY -IN SHOWN, FOR DAMPER ACCESS IN GYP -BOARD SIMILAR). SURFACE MOUNT SIMILAR). NO- ACCESSIBLE CEILINGS. FLEXILE F D 1 NOIND 1. FLEXIBLE DUCTS SHALL BE ONE -PIECE AND SHALL NOT BE SPLICED TOGETHER. 2. EXTEND FLEXIBLE DUCT INSULATION TO DUCT /DIFFUSER PANEL INSULATION AND SEAL WITH MASTIC. 3. MINIMUM 1" WIDE 22 GALVANIZED STRAP HANGER WITH HEMMED EDGES PER SMACNA. FIGURE 3 -10 4. FLEXIBLE AIR DUCT SHALL BE FULLY EXTENDED AND NOT COMPRESSED WITH ELBOW RADIUS NOT LESS THAN R/D = 1.0 5. PROVIDE NON METALLIC, INSULATED FLEXIBLE DUCT. FLEXIBLE DUCT CONNECTION DETAIL N.T.S. 1 "X16 GA. STRAPPING WITH 1" RETURN BEND ON BOTTOM AND SCREWED TO SIDE OF DUCT. NOTE: SCREWS MAY BE OMITTED IF HANGER LOOPS STRAP HANGERS CONC. SLAB PSI JOIST. 60" MAX HANGER STRAPS - SCREWS OR POWDER ACTUATED FASTENERS. UNLESS FOOT OF STRAP IS PLACED DUCT UNDER A I BOTTOM REINFORCEMENT SUSPENDED CEILING (SEE ARCH. DRAWINGS) TRAPEZE HANGERS CONC. SLAB STRAP OR A Mf'A r SIZE BOLT(S) FOR LOAD SCREWS FASTENERS. HANGER WIRE 12 GAUGE (MIN.) DUCT DUCT HANGER DETAIL SHEET METAL CHANNEL N.T.S. TABLE 4 -1 RECTANGULAR DUCT HANGERS MINIMUM SIZE MAXIMUM PAIR AT PAIR AT PAIR AT PAIR AT HALF OF 10 FT SPACING 8 FT SPACING 5 FT SPACING 4 FT SPACING DUCT 12" THRU 24" 2 #14 WIRE / 1/4" WIRE / 16 WIRE / 1/4- DIA. 1 1/2- WIRE/ PERIMETER STRAP ROD STRAP ROD STRAP ROD STRAP ROD P F = 30" 2 1 "x22 GA 10 GA. (.135 ") 1 x . . GA 10 GA. (.135 ") 1 "x22 CA. 12 GA. (.106 ") 1 "x22 GA 12 GA. (.106 ") 2 Q 72" 1 "x18 GA. 3/8" 1 "x20 GA. 1/4' 1 "x22 GA. 1/4" 1"x22 GA. 1/4" 2 = 96" 1 "x16 GA. 3/8" 1 "x18 GA. 3/8" 1"x20 GA. 3/8" 1 "x22 GA. 1/4" F = 120" 1.5 "x16 GA. 1/2" 1 "x16 GA. 3/8" 1 "x18 GA. 3/8' 1"x20 GA. 1/4" 2 - 168" 1.5 "x16 GA. 1/2" 1.5"x16 GA. 1/2* 1"x1 6 GA. 1/2* 1"x18 GA. 3/8" 2 = 192" - 1/2' 1.5"x16 GA. 1/2' 1 "x16 GA. 1/2* 1"x16 GA. 3/8" 2 2 - 193" UP SPECIAL ANALYSIS REQUIRED AS PER SMACNA TABLE 4 -1 & FIG. 4 -4 CLINCH EN 1/4" 0 GALV. TO BRANCH DI TYPICAL DETAIL OF A 900 DUCT TAP WITH DAMPER BLADE N.T.S. PROVIDE VIBRATION ISOLATORS MASON MODEL PC30N OR EQUAL ROOF WALL RETURN AIR PLENUM — RETURN AIR DUCT PROVIDE 3/4" DRAIN CONNECTION W/ REMOVABLE PLUG. 24 GA. MIN. GALV. STEEL DRAIN PAN 1 -1/2" DEEP MIN. ALL WELDED CONSTRUCTION. BOWS SHALL HAVE 'ANES AS PER SMACNA. TRUNK DUCT 18 GAGE GALV. SHEET STEEL DAMPER BLADE, FULL HEIGHT OF MAIN DUCT. DOUBLE BEND LEADING EDGE OF DAMPER BLADE. FLOW D DUCTS FIBROUS GLASS DUCT. GLASS FABRIC AND AND MASTIC (GFM) CLOSURE OVER POCKECT LOCK AND DUCT BOARD. FAN COIL UNIT SURFACE. #10 X 1-1/4- SHEET METAL SCREWS 12" MAX. O.C. MIN. 2 PER SIDE. �— 22 Go. SHEET METAL POCKET LOCK 1 "X 1 "X 1 " CONNECTION DETAIL N.T.S. NOTE. 1-1/2- PVC SCH. 40 I. S -0" CLEAR FROM FAN COIL UNIT MAINTENANCE. SLEEVE (TYP.) REFRIGERANT PIPES DISCONNECTED SWITCH FAN COIL UNIT SECURED TO STRUCTURE WITH 3/8" DIA GALV. THREADED RODS. REFRIGERANT SCREEN GALV. STEEL 16 PIPES i SUPER STRUT - HANGER RODS DISCHARGE DUCT 8" MIN. PIPE SUPPORT 3' IN ALL FOUR SIDES �— FIN. CEILING AUXILIARY DRAIN PAN W/ FLOAT SWITCH, FLOAT SWITCH TO STOP UNIT WHEN SWITCH OPENS. CONDENSATE DRAIN LINE AND TRAP REFER TO DWG. HORIZONTAL FAN COIL UNIT MOUNTING DETAIL N.T.S. CONDENSING UNIT 6" MIN. --� REFER CONDENSING UNIT TIE DOWN DETAIL CONCRETE BASE W/ . '. 6 X 6 - 10/10 WWF 6" MIN. REFRIGERANT SUCTION & LIQUID LINES TO FCU. POWER & CONTROL CONNECTIONS 6" MIN. 6" MIN. /.. \� / SUCTION LINE W/ 1/2" ARMAFLEX INSULATION & VAPOR BARRIER NOTE: CONCRETE SCREWS SHALL BE RATED FOR 500 LBS. MIN. PULL -OUT CAPACITY. CONDENSING UNIT MOUNTING DETAIL N.T.S. EZ TRAP EZT- SERIES 200 - CONNECT SWITCH TO SHUT DOWN SYSTEM ON OVERFLOW SECONDARY /OVERFLOW DRAIN LINE GALVANIZED SHEET METAL COWL FILL WITH FOAM INSULATION (TYP.) TYPICAL SUPPORT BETWEEN FLOORS AT 8' -0" 0/C VERTICALLY T1I1111� 12" ROOF CURB ROOFING — REFRIGERANT PIPE CHASE IN PARTITION REFRIGERANT PIPING COWL DETAIL N.T.S. NOTE: GROUND MOUNTED UNITS, IS BASED ON THE REQUIREMENTS OF THE FLORIDA BUILDING CODE. TO COMPLY WITH THE WIND RESISTANCE AND ANCHORING AS SPECIFIED IN SECTIONS 301.13 AND 301.13.1 COND. UNIT TIE DOWN SCHEDULE UNIT SIDES # SCREWS PER SIDES ANCHOR EMBEDMENT DIA. # CONCRETE SCREWS BOLTS STEEL ANGLE GAGE 12" 1 #14 3/16" DIA. 1 1/4" 1/4" 1 "X1 "X1" 18 12" THRU 24" 2 #14 1/4" DIA. 1 1/2" 1/4" 2 "X2 "X2" 16 24" THRU 36" 3 #14 1/4- DIA. 1 1/2- 1/4- 2*X2"X2" 16 36" OR 5 TONS 3 #12 1/4" DIA. 1 3/4" 1/4" 2"X2"X2*i 16 MAXIMUN WIND SPEED OF 150 MILES PER HOUR. 2 "X2 "X2" LONG 16 GAGE FABRICATED STEEL ANGLE (G90) FASTENED TO THE UNIT FRAME USING 2- #14 SCREWS WITH GASKETED WASHERS. (REFER TABL ISOLATOR PAD --� \-1/4- CONCRETE SCREWS BOLTS & WASHERS, PENETRATE 1 1/2" MIN. (BY MECHANICAL CONTRACTOR) C.U. UNIT TIE DOWN DETAIL N.T.S. 3/4' —I- 3/4' REMOVABLE SCREW-CAP (TYPICAL FOR ALL AHU) PERFORATED VENT CAP z t UNION COMPLIES WITH FBC -2001 MECH VOL SECTION 307.2 PIPES TO BE COMM, CPVC FLOWGUARD SCHED 40, OR REGULAR PVC SCHED 40 W/FIREPROOF WRAPPING. AHU COND. DRAIN LINE W f AUX. OVERFLOW SWITCH N.T.S TURNING VANI FOR SMACNA STANDARDS. TYPICAL 90— DEGREE VANED ELBOW DETAIL. N.T.S. CITY OF SOUTH MIAMI BUILDING DEPT. MECHANICAL SECTION STEEL BLADES W/ INTERLOCKING JOINTS MOUNTING ANGLES. FASTENED TO SLEEVE NOTE: FIRE DAMPER TYPE WITH BLADES OUT OF AIR STREAM. VERTICAL FIRE DAMPER DETAIL N.T.S. MOUNT DAMPER AS PER U.L. STANDARDS AND MANUFACTURER RECOMMENDATIONS. DYNAMIC FIRE DAMPER UL 5% RATED WITH 165F FUSIBLE LINK. FIRE DAMPER 100% FREE AREA DUCTWORK. SEE PLAN FOR SIZES. "S" SUP BREAKAWAY JOINT, ALL AROUND, BOTH SIDES, 6" MAX. ON ALL SIDES. K0(NOTES - 10LOcus ARCHITUCrURs INCOR/ORATID CONSULTANT(S) T T Consufting Engineers, Inc. CA 26441 MECHANICAL - PLUMBING - ELECTRICAL 9520 S.W. 40 8T. BUTTE 207 - MIAMI FLORIDA 33155 OFFICE (305) 225$377 - FAX (305) 225 -8378 EMAIL 7FENGINEER8®BO I OL THNEt NO. REVISION /SUBMISSION DATE SPECIAL USE PLANNING12 -14 -07 BOARD REVIEW PERMIT SET 02 -20 -08 PROJECT Interior Plan for: CAVAS WINE CAFE SOUTH MIAMI MUNICIPAL GARAGE 5829 SW 73rd Street, Units #7-8 South Miami, Florida 33143 DRAWING DETAILS MECHANICAL SEAL SCALE Nestor J. Cifuentes 114 " =1' -0" PE # 29450 CC 1 . • I� Signature Date ��� �$ ±'�� � k I� • - - 123.0 ••• SHEET NO. � j AC -2