Loading...
08-497-021SPECIFICATIONS CONT. SECTION 09666- RESILIENT SHEET AND VINYL FLOORING SECTION 09900 - PAINTING SECTION 06255- FIBERGLASS REINFORCED PANELS DMSION 8 DOORS AND WINDOWS ALLIED SLIP RESISTANT SAFETY FLOORING SYSTEM 1. PROVIDE LABOR, MATERIALS, EQUIPMENT AND RELATED ITEMS REQUIRED TO COMPLETE THE EXTERIOR 1. FRP PANELS: 48" WIDE, 3/32' THICKNESS, COLOR VHITE' AS INDICATED ON DRAWINGS. Fax (305) 740 -0520 License No. AA0002733 CONSULTANi(S) AND INTERIOR ITEMS AND SURFACES THROUGHOUT THE PROJECT INCLUDING FILING, SEALING, REVISION/SUBMISSION SECTION 08710- FINISH HARDWARE VENDOR: PRIMING, AND FINISHING. A. MARUTE - ALLIED COMPANIES, LLC. PERMIT SET VENDOR: 3013 BANK STREET 2. MECHANICAL AND ELECTRICAL WORK TO BE PAINTED INCLUDES THE FOLLOWING (BUT NOT LIMITED TO): B. KEMUTE GINESTA DOORS -' CHARLOTTE, NC28203 PHONE: 305 - 805 -5368 PHONE: (800) 767 -5754 A) EXPOSED PIPING AND OR PIPE INSULATION, INSIDE AND OUTSIDE BUILDING. 2. FRP ACCESSORIES: FAX: (704) 522 -0598 B) MECHANICAL EQUIPMENT SUPPORTS AND DUCTWORK. 1. ALL DOOR HARDWARE WILL BE FURNISHED BY THE CONTRACTOR. A SCHEDULED OF HARDWARE IS WWW.ALLIEDFLOOR.COM C) EXPOSED CONDUIT, BOXES, PANEL FRONTS. A. ALL MOLDINGS, TRIM ADHESIVE AND OTHER ACCESSORIES SHALL BE AS SHOWN ON DRAWINGS. Interior Plan for: CAVAS WINE CAFE MANUFACTURED AND RECOMMENDED BY THE SAME MANUFACTURER AS PANELS. 5829 SW 73rd Street, Units #7 -8 South Miami, Florida 33143 1. PRODUCT DESCRIPTION 3. ENSURE SURFACE TEMPERATURE AND THE SURROUNDING AIR TEMPERATURE ARE ABOVE 50 DEGREES F, zi �x ,, 2. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURE'S RECOMMENDATIONS, USING PROPER THE ALLIED SUP RESISTANT SAFETY FLOORING SYSTEM PROVIDES PROTECTION IN HEAVY TRAVELED BEFORE APPLYING PAINT AND MATERIALS. 3. SEALANT -:::U, it TEMPLATES. ENVIRONMENTS. THE UNIQUE SURFACE DESIGN PROVIDES EXCELLENT TRACTION EVEN WHEN REVIEWED INDL [ °P Si.. :�1{ .• v WET AND /OR GREASY. 4. PROVIDE MINIMUM 25 FOOT CANDLES OF LIGHTING ON SURFACES TO BE PAINTED. A. ONE PART SILICONE RUBBER, ASTM C920 AND FS Tr-S-001 543A, FDA 3. DO NO INSTALL SURFACE - MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON THE APPROVED, OR AS RECOMMENDED BY FRP MANUFACTURER. SUBSTRATE, 2. APPLICATIONS 5. ACCEPTABLE MANUFACTURER FOR PREP & WALK-IN COOLER/FREEZER AREAS. B. COLOR: CLEAR AND WHITE, UNLESS NOTED OTHERWISE. 4. SET UNITS LEVEL, PLUMB, AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE A) BENJAMIN MOORE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION. 3. TECHNICAL DATA 4. INSTALL PANELS OVER MOISTURE RESISTANT DRYWALL IN STRICT ACCORDANCE WITH MANUFACTURER'S APPLICABLE STANDARDS 6. PERFORM PREPARATION, FILLING, SEALING, SANDING, AND CLEANING OF SURFACES SCHEDULED TO BE RECOMMENDATIONS, USING NONFLAMMABLE ADHESIVE (100 % COVERAGE). 5. DRILL AND COUNTERSINK UNITS WHICH ARE NOT FACTORY-PREPARED FOR ANCHORAGE FASTENERS. ANSI AT 18.10 -1999 PAINTING IN ACCORDANCE WiTH PAINT MANUFACTURER'S INSTRUCTIONS. SPACE FASTENERS AND ANCHORS IN ACCORDANCE WITH INDUSTRY STANDARDS. ANSI AT 18.12 A. DRYWALL MUST BE INSTALLED (AND ALL JOINTS TAPED) FLOOR TO CEILING TO PROVIDE 7. REMOVE HARDWARE AND ACCESSORIES, FITTINGS, AND FASTENING, ELECTRICAL PLATES, LIGHTING A GOOD BONDABLE SURFACE TO ACCEPT INSTALLATION OF FRP PANELS. 6. MOUNT HARDWARE UNiTS AS INDICATED IN DHI 'RECOMMENDED LOCATIONS FOR BUILDERS' 4. INSTALLATION FIXTURES AND SIMILAR ITEMS. REINSTALL REMOVED ITEMS AFTER COMPLETION OF PAINTING. HARDWARE FOR STANDARD WOOD DOORS AND FRAMES ". THE FOLLOWING OVERVIEW PROVIDES BASIC INSTALLATION INFORMATION REFER TO DATA SHEET 5. DISCARD UNITS OF MATERIAL WHICH ARE UNSOUND, WARPED, BOWED, TWISTED, IMPROPERLY WPAF.5 (INCLUDED IN UNIT) FOR COMPLETE INSTRUCTIONS OR VISIT WWW.LATiCRETE.COM. 8. DO NOT PAINT OVER DIRT, DUST, STAINS, RUST, SCALE, OIL, GREASE, MOISTURE, SCUFFED SURFACES, OR TREATED, OR TOO SMALL TO FABRICATE WORK WITH MINIMUM OF JOINTS OR OPTIMUM JOINTING 7. THROUGH -BOLT ALL DOOR CLOSURES. OTHER CONTAMINATION OR CONDITIONS DETRIMENTAL TO FORMATION OF A DURABLE PAINT FILM. ARRAGEMENTS, OR WHICH ARE OF DEFECTIVE MANUFACTURE WiTH RESPECT TO SURFACES, SURFACE PREPARATION SIZES, OR PATTERNS. 8. SCREW THRESHOLDS TO SUBSTRATE WITH NO. 10 OR LARGER STAINLESS STEEL SCREWS OF THE SURFACE TEMPERATURE MUST BE 45 -90 °F (7 -32 °C) DURING APPLICATION AND FOR 24 HOURS AFTER 9. BACKPRIME AS FOLLOWS: PROPER TYPE FOR PERMANENT ANCHORAGE OF THRESHOLD. INSTALLATION. ALL SUBSTRATES MUST BE STRUCTURALLY SOUND, CLEAN AND FREE OF DIRT, OIL, A) INTERIOR PAINTED WOOD; "LATEX INTERIOR PRIMER' 6. SCRIBE AND CUT WORK TO FR ADJOINING WORK. GREASE, LOOSE/PEEUNG PAINT, LAITANCE, EFFLORESCENCE, CONCRETE SEALERS OR CURING B) INTERIOR PAINTED GYPSUM BOARD; "LATEX INTERIOR PRIMER' A. SET THRESHOLDS AT EXTERIOR DOORS IN A BED OF MASTIC SEALANT TO COMPLETELY COMPOUNDS. MAKE ROUGH OR UNEVEN CONCRETE SMOOTH TO A WOOD FLOAT OR BETTER FINISH A. CAULK ALL JOINTS AND ALL MOLDINGS WITH SILICONE SEALANT. FILL CONCEALED VOIDS AND EXCLUDE MOISTURE FROM EVERY SOURCE. DO NOT PLUG WiTH A LATiCRETE UNDERLAYMENT. DO NOT LEVEL WiTH GYPSUM OR ASPHALT BASED PRODUCTS. 10. APPLY PAINT IN ACCORDANCE WiTH PAINT MANUFACTURER'S INSTRUCTIONS AND AS HEREIN SPECIFIED. DRAINAGE HOLES OR BLOCK WEEPS. REMOVE EXCESS SEALANT. MAXIMUM DEVIATION IN PLANE MUST NOT EXCEED 114' IN 10 FT (6 MM IN 3 M) WITH NO MORE B. PANELS TO BE APPLIED TO THE WALL WiTH THE 48' DIMENSION HORIZONTAL, AND IN THAN 1/16- IN 1 FT. (1.5 MM IN 0.3 M) VARIATION BETWEEN HIGH SPOTS. DAMPEN HOT, DRY SURFACES 11. APPLY EACH COAT OF PAINT AT NO LESS THAN SPREADING RATE INDICATED IN MANUFACTURERS LENGTHS TO EXTEND FROM BASE TO CEILING WiTH NO INTERMEDIATE HORIZONTAL. 9. SURFACE MOUNTED WEATHERSTRIPPING SHALL BE INSTALLED PRIOR TO OTHER SURFACE MOUNTED AND SWEEP OFF EXCESS WATER -- INSTALLATION MAY BE MADE ON A DAMP SURFACE. NEW CONCRETE INSTRUCTIONS. HARDWARE WITHOUT BREAKS. COORDINATE HARDWARE ACCESSORIES TO SUIT CONTINUOUS SLABS SHALL BE DAMP CURED AND A MINIMUM OF 14 DAYS OLD BEFORE APPLICATION. MAXIMUM C. INSTALL THE WORK PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. SHIM AS WEATHERSTRIP. AMOUNT OF MOISTURE IN THE CONCRETE SUBSTRATE SHOULD NOT EXCEED 5 LBS. /1000 SQUARE FEET 12. SAND LIGHTLY BETWEEN ENAMEL COATS. REQUIRED USING CONCEALED SHIMS. INSTALL TO A TOLERANCE OF 1 /8' IN V -0' FOR (2.26 KG/92.9 M2) 24 HRS. PER ASTM F -1869 OR 75 % RELATIVE HUMIDITY AS MEASURED WiTH MOISTURE PLUMB AND LEVEL, AND WiTH THE 1/160 MAXIMUM OFFSET IN FLUSH ADJOINING SURFACES. 10. CLEAN OPERATING ITEMS AS NECESSARY TO RESTORE PROPER FUNCTION AND FINISH OF HARDWARE. PROBES. DS -236.0 -0707 13. ITEMS/SURFACES SCHEDULED TO BE PAINTED TO PROVIDE A SMOOTH SURFACE OF UNIFORM FINISH, COLOR, APPEARANCE AND PAINT MATERIAL COVERAGE FREE FROM CLOUDINESS, DMSION 7 THERMAL AND MOISTURE PROTECTION 11. ADJUST DOOR CONTROL DEVICES TO COMPENSATE FOR FINAL OPERATION OF HEATING AND PRE -TREAT CRACKS & JOINTS ^ SPOTTING, LAPS, BRUSH MARKS, RUNS, STREAKS, SAGS, AND OTHER SURFACE SECTION 07210- BUILDING INSULATION VENTILATING EQUIPMENT. APPLY LIBERAL COAT" OF LATiCRETE® 9235 WATERPROOFING MEMBRANE LIQUID APPROXIMATELY 8" IMPERFECTIONS. (200 MM) WIDE OVER SUBSTRATE CRACKS, COLD JOINTS, CONTROL JOINTS AND BOARD JOINTS USING A PAINT 1. BATT INSULATION: PERFORMED GLASS FIBER BATT: BLANKETS WITH FOIL FACE MEMBRANE SECTION 09260 - GYPSUM BOARD SYSTEMS 14. PAINT ITEMS/SURFACES LISTED FOR EACH OF THE FOLLOWING SUBSTRATES WITH THE SYSTEM OF PAINT COVERING; PER ASTM C665, TYPE III; DENSITIES OF NOT LESS THAN 0.518. PER CU. FT. BRUSH OR ROLLER (HEAVY NAPPED ROLLER COVER). PLACE 6" (150 MM) WIDE LATICRETE COATS SPECIFIED. COLORS ARE TO BE DETERMINED IN THE FIELD. FOR GLASS FIBER UNiTS, K -VALUE OF 0.27; FLAME SPREAD OF 25 OR LESS, ASTM E84 1. GYPSUM PANELS - TYPES REQUIRED: WATERPROOFING /ANTI- FRACTURE FABRIC MEMBRANE REINFORCING FABRIC INTO THE WET LATiCRETE 9235 (CLASS A), 6' (R -19) UNLESS OTHERWISE NOTED. WATERPROOFING MEMBRANE LIQUID. PRESS DOWN ON LATiCRETE WATERPROOFING /ANTI- FRACTURE FABRIC A) WOOD DOORS (STAINED) A. REGULAR BOARD: ASTM C36, TAPERED EDGES, WITH BRUSH OR ROLLER UNTiL THE LATICRETE 9235 WATERPROOFING MEMBRANE LIQUID "BLEEDS' THROUGH STAIN COAT: 1 COAT A. CERTAINTEED CORP. THICKNESS 5/8'. FROM BELOW. THEN APPLY ANOTHER LIBERAL COAT" ^ OF LATiCRETE 9235 WATERPROOFING MEMBRANE FINISH: 2 COATS LIQUID OVER THE ENTIRE SURFACE OF THE LATiCRETE WATERPROOFING /ANTI- FRACTURE FABRIC. B. SCHULLER INTERNATIONAL B. FIRE RATED BOARD: ASTM C36, USG TYPE SCX OR EQUAL, TAPERED EDGES, PRE -TREAT COVES, CORNERS & SEAMS APPLY A LIBERAL COAT" ^ OF LATiCRETE 9235 WATERPROOFING B) INTERIOR GYPSUM BOARD THICKNESS 5/8 '. MEMBRANE LIQUID APPROXIMATELY 8' (200 MM) WIDE OVER SUBSTRATE COVES, CORNERS, SEAMS, JOINTS PRIMER: 1 COAT C. OWENS - CORNING FIBERGLASS CORP. AND CHANGES IN PLANE USING A PAINT BRUSH OR ROLLER (HEAVY NAPPED ROLLER COVER). FOLD 6" (15 CM) FINISH: 2 COATS C. MOISTURE RESISTANT AND FIRE RATED BOARD: USG-WRX, TAPERED EDGES, THICKNESS 5/8'. WIDE LATiCRETE WATERPROOFING /ANTI- FRACTURE FABRIC IN HALF AND PLACE IT INTO THE D. UNITED STATES GYPSUM CO. COAT"' ^ OF WET LATiCRETE 9235 WATERPROOFING MEMBRANE LIQUID. D. CEMENT BACKER BOARD FOR TILE SHALL BE'1NONDERBOARD" OR'DUROCK' , 5/8" E. KNAUF FIBERGLASS NOMINAL THICKNESS. FLASH LATiCRETE WATERPROOFING /ANTI- FRACTURE FABRIC 3" (75 MM) UP WALLS AND OTHER VERTICAL SURFACES. PRESS DOWN ON LATTCRETE WATERPROOFING /ANTI- FRACTURE FABRIC WiTH BRUSH OR ROLLER UNTIL SECTION 10500- PORTABLE FIRE EXTINGUISHERS 2. SOUND ATTENUATION INSULATION: USG 'SAFB', 2.5 POUND /CU. FT. DENSITY, NO SUBSTITUTION. 2. STUDS, TRIM AND ACCESSORIES THE LATiCRETE 9235 WATERPROOFING MEMBRANE LIQUID 'BLEEDS' THROUGH FROM BELOW. THEN APPLY ANOTHER LIBERAL COAT^ ^ OF LATiCRETE 9235 WATERPROOFING MEMBRANE LIQUID OVER THE ENTIRE 1. MATERIALS 3. INSTALLATION ACCESSORIES AND ADHESIVES SHALL BE AS RECOMMENDED BY INSULATION A. STEEL STUDS: PER ASTM C645 GALVANIZED GAUGES AS NOTED. TRACK SHALL BE SURFACE OF THE LAT1CREwA&TE WATERPROOFING /ANTI- FRACTURE FABRIC. MANUFACTURER FOR TYPE OF APPLICATION AND CONDITION OF SUBSTRATE. ONE SIZED HEAVIER THAN STUDS. A. PROVIDE 1 K CLASS FIRE EXTINGUISHER IN KITCHEN AREA. LATiCRETE® 9235 WATERPROOFING MEMBRANE MUST BE DRIED TO THE TOUCH, PRIOR TO FINISH[ B. PROVIDE 2 5LB. 2A110BC FIRE EXTINGUISHERS IN SITTiNG/REAR AREA. 4. INSTALL BATT INSULATION IN ACCORDANCE WiTH MANUFACTURER'S INSTRUCTIONS. B. CORNER BEADS, CONTROL JOINTS, AND EDGE TRIM: PER ASTM C1047, EQUAL TO INSTALLATION. ALLOW LATiCRETE 9235 WATERPROOFING MEMBRANE TO CURE 7 DAYS AT 70 °F (21 °C) AND C. PROVIDE MANUFACTURERS RECOMMEND MOUNTING BRACKETS AND HARDWARE. USG #103 "DUR- A- BEAD ", #093 AND #200 -A RESPECTIVELY, GALVANIZED. 50% RH BEFORE COVERING WITH CONCRETE, THICK BED MORTAR, SCREEDS, TOPPINGS, COATINGS, EPDXY A. PLACE BATT INSULATION IN PARTITIONS TiGHT WITHIN SPACES, AROUND CUT OPENINGS, UNLESS OTHERWISE DETAILED, EXPOSED 'J" TRIM IS NOT ACCEPTABLE. ADHESIVES, TERRAllO OR MOISTURE SENSITIVE RESILIENT OR WOOD FLOORING. DO NOT USE SOLVENT-BASED 2. INSTALLATION BEHIND AND AROUND ELECTRICAL AND MECHANICAL ITEMS WITH OR BEHIND ADHESIVES DIRECTLY ON LATiCRETE 9235 WATERPROOFING MEMBRANE. PARTITIONS AND TIGHT TO ITEMS PASSING THROUGH PARTITIONS. 3. FASTENERS: SCREWS, PER ASTM 1002; 1 -1 AN TYPE "1M BUGLE HEAD INTO WOOD FRAMING, A) INSTALL PER MANUFACTURERS RECOMMENDATIONS IN ACCORDANCE WITH LOCAL FIRE 1 -1/8' TYPE'S' BUGLE HEAD INTO STEEL FRAMING, AND 3/8" TYPE'S -12' PAN (OR LOW PROFILE) HEAD FOR DRAINS & PENETRATIONS MARSHALL REQUIREMENTS IN LOCATIONS AND QUANTITY AS DIRECTED BY THE LOCAL FIRE B. TRIM INSULATION NEATLY TO FIT SPACES. FILL GAPS OR VOIDS WiTH INSULATION. STEEL TO STEEL FRAMING CONNECTIONS. ALLOW FOR A MINIMUM 114- (6 MM) SPACE BETWEEN DRAINS, PIPES, LIGHTS OR OTHER PENETRATIONS AND MARSHALL. SURROUNDING CERAMIC TiLE, STONE OR BRICK. SECTION 10800- TOILET ACCESSORIES C. INSTALL INSULATION WITH FACTORY APPLIED MEMBRANE FACING WARM SIDE OF 4. JOINT TREATMENT MATERIALS. BUILDING SPACES. SURFACE PREPARATION: SURFACE SHOULD BE CLEAN AND FREE OF DEBRIS THAT MAY PROHIBIT AWED SLIP 1. ALL TOILET ACCESSORIES ARE FURNISHED BY CONTRACTOR. COORDINATE ROUGH -IN OPENINGS A. STEEL FRAMING, BOARD APPLICATION AND FINISH STANDARDS: GA216 AND ASTM RESISTANT SAFETY FLOORING FROM LAYING FLAT. UNEVEN JOINTS AND CRACKS WHICH CREATE AN UNLEVEL AND WOOD BLOCKING OR BACKING. C754 AND C840. STUDDING SHALL BE 16" O.C. UNLESS OTHERWISE NOTED. CONDITION, SHOULD BE REPAIRED USING AN APPROVED UNDERLAYMENT OR LEVELING COMPOUND. AWED PROVIDE HORIZONTAL BRACING AT 4' -0" O.C. MEASURED VERTICALLY. FRAME DOOR SLIP RESISTANT SAFETY FLOORING IS TO BE INSTALLED FOLLOWING NORMAL INSTALLATION PROCEDURES. 2. INSTALL FIXTURES, ACCESSORIES AND ITEMS IN ACCORDANCE WiTH MANUFACTURER'S INSTRUCTIONS. SECTION 06200- FINISH CABINETRY OPENINGS TO COMPLY WiTH GA219. CUTTING AND TRIMMING CAN BE ACHIEVED USING A STANDARD UTILITY KNIFE OR SIMILAR RAZORBLADE -TYPE AND WHERE AFFECTED, AT HEIGHTS OR LOCATIONS FOR THE HANDICAPPED AS INDICATED OR Tom• SPECIFIED HEREIN. 1. SEALANT TYPE 1: ONE COMPONENT, ACRYLIC LATEX, FOR INTERIOR NON - MOVING JOINTS. B. INSTALL CEILING BOARDS IN THE DIRECTION AND MANNER WHICH WILL MINIMIZE THE NUMBER OF END BUTT - JOINTS, AND WHICH WILL AVOID END JOINTS IN THE CENTRAL 5. WARRANTY 'LAIICRETE') 3. INSTALL TRUE, PLUMB AND LEVEL, SECURELY AND RIGIDLY ANCHORED TO SUBSTRATE. A. SONNEBORN'SONOLAC' OR EQUAL. AREA OF EACH CEILING. STAGGER END JOINTS AT LEAST 4' -0'. LATiCRETE INTERNATIONAL, NC( WARRANTS THE PRODUCT WILL BE FREE FROM MANUFACTURING DEFECTS AND WILL NOT BREAK DOWN OR DETERIORATE UNDER NORMAL USAGE FOR A PERIOD OF TEN (10) 4. REFER TO CONSTRUCTION DOCUMENTS FOR EQUIPMENT LIST. 2. SEALANT TYPE 2: ONE COMPONENT URETHANE, GUN- GRADE, NON -SAG, FOR INTERIOR OR C. INSTALL WALL/PARTITION BOARDS VERTICALLY TO AVOID END -BUTT JOINTS WHEREVER YEARS FROM THE DATE OF PURCHASE WHEN INSTALLED IN ACCORDANCE WITH THE WRITTEN SPECIFICATIONS EXTERIOR EXPOSED MOVING JOINTS, THRESHOLDS AND ARCHITECTURAL SHEET METAL. POSSIBLE. OF LATiCRETE AND INDUSTRY STANDARD GUIDELINES. DMSION 6 GENERAL REQUIREMENTS A. SONNEBORN 'NPl' OR EQUAL. D. LOCATE EITHER EDGE OR END JOUNTS OVER SUPPORTS. STAGGER JOINTS OVER 6. TECHNICAL SERVICES DIFFERENT STUDS ON OPPOSITE SIDES OF PARTITIONS. TECHNICAL ASSISTANCE SECTION 06200- FINISH CABINETRY INFORMATION IS AVAILABLE BY CALLING: 1. SOFTWOOD LUMBER: GRADED IN ACCORDANCE WITH THE REQUIREMENTS OF AWI QUALITY 3. SEALANT TYPE 3: MULTi- COMPONENT, URETHANE, GUN- GRADE, NON -SAG, FOR INTERIOR OR EXTERIOR EXPOSED MOVING JOINTS (OTHER THAN PAVEMENTS), DOOR AND WINDOW FRAMES, E. SPACE FASTENERS IN GYPSUM BOARD IN ACCORDANCE WITH REF. STANDARDS AND TOLL FREE: 800.243.4788, EXT. 235 STANDARDS• MAXIMUM MOISTURE CONTENT OF 6 PERCENT FOR INTERIOR WORK AND 10 PERCENT MANUF RECOMMENDATIONS, EXCEPT AS OTHERWISE INDICATED. 7. SPECIFICATIONS SIZE SHEETS - 60'X 60" AND 60"X 96' ROLLS- 60" X 25' SQUARE TiLE - 24' X 24" THICKNESS: Ya' COLOR: DARK GRAU SURFACE PATTERNS: MATTE ALLIED SUP RESISTANT SAFETY FLOORING IS MANUFACTURED FROM 100 % RECYCLED POLYVINYL CHLORIDE (PVC) WITH FABRIC STRAND REINFORCEMENT TO INCREASE OVERALL PRODUCT RIGIDITY AND PHYSICAL STRENGTH. 8. CLEANING INSTRUCTIONS MAY BE CLEANED USING STANDARD FLOOR CLEANING PRACTICES, EXCEPT THAT A POWER SCRUBBER MAY BE REQUIRED FOR HIGH TRAFFIC OR ABUSIVE LOCATIONS. FOR EASE OF MAINTENANCE ON INTERIOR INSTALLATIONS, ALLIED COMPANIES TRACTION ENHANCEMENT DAILY CLEANER IS THE RECOMMENDED CONCENTRATE FOR COMMERCIAL KITCHEN APPLICATIONS. 9. ALLIED COMPANIES TEST DATA BACTERIA & MILDEW RESISTANCE: EXCELLENT ASTM G-21 FIRE TEST: NFPA TYPE I RATED THICKNESS: .250 INCHES WEIGHT (OZ. SQ. FT.): 25.16 ASTM D -751 FOR EXTERIOR WORK. 2. SOFTWOOD PLYWOOD: GRADED IN ACCORDANCE WITH AWI QUALITY STANDARDS; CORE MATERIAL OF VENEER; OF MAHOGANY OR BIRCH VENEER, PAINT GRADE VENEER, OR PLASTIC LAMINATE AS INDICATED. 3. PLASTIC LAMINATE: NEMA LD-3; GP -50 FOR HORIZONTAL AND VERTICAL SURFACES OVER MARINE PLYWOOD CL -20 FOR BACKING AND UNEXPOSED SURFACES. 4. NAILS: SIZE AND TYPE TO SUIT APPLICATION. 5. BOLTS, NUTS, WASHERS, LAGS, PINS, AND SCREWS: SIZE AND TYPE TO SUIT APPLICATION. 6. INTERIOR WOOD FINISH: A. SOLID WOOD: PLAIN -SAWN OAK, LOCATION AS INDICATED ON THE DRAWINGS. B. PLYWOOD: 5/8" AB GRADE FIR PLYWOOD EXPOSED EDGES BANDED. 7. FABRICATE FINISH CARPENTRY AND CABINETWORK ITEMS IN ACCORDANCE WITH AWI QUALITY STANDARDS 'CUSTOM GRADE', AND SECTION 400 OF THE AWI GUIDE. SHOP FABRICATE ITEMS WHERE POSSIBLE. B. APPLY PLASTIC LAMINATE FINISH IN FULL UNINTERRUPTED SHEETS CONSISTENT WiTH MANUFACTURED SIZES. CORNERS AND JOINTS TO BE HAIRLINE. 9. CAP EXPOSED PLASTIC LAMINATE EDGES WITH MATERIAL OF SAME FINISH AND PATTERN. 10. USE EXPOSED FASTENING DEVICES OR NAILS ONLY WHEN UNAVOIDABLE. 11. SAND WORK SMOOTH AND SET EXPOSED NAIL AND SCREW INDENTATIONS AND LEAVE READY TO RECEIVE SiTE APPLIED FINISHES. 12. SET AND SECURE FINISH CARPENTRY AND CABINETWORK ITEMS IN PLACE, RIGID, PLUMB, AND SQUARE. 13. INSTALL AND ADJUST CABINET HARDWARE TO CORRECT OPERATION. 14. FINISH WOODWORK SHALL BE SET STRAIGHT, PLUMB OR LEVEL, CLOSELY FITTED AND RIGIDLY FASTENED. NAIL HEADS OF EXPOSED WORK SHALL BE SET FOR PUTTY AND OTHER FASTENINGS SHALL BE CONCEALED. 15. JOINTS SHALL BE TIGHT AND FORMED TO CONCEAL SHRINKAGE. ALL TRIM TO BE MITERED; NO BUTT JOINTS PERMITTED. INTERIOR CORNERS SHALL BE COPED. 16. INSTALL DOORS PLUMB, TRUE AND FITTED PROPERLY. LEAVE IN PERFECT WORKING ORDER. WARPED DOORS WILL BE REJECTED AND SHALL BE REPLACED. NEATLY MORTISE, DRILL, AND ANCHOR ALL HARDWARE. 17. CONCEAL FASTENERS WHEREVER POSSIBLE. WHERE NOT POSSIBLE, LOCATE THEM IN AN INCONSPICUOUS PLACE. WHERE NAILS OR SCREW ATTACHMENT OCCUR IN WOODWORK FACE, COUNTERSINK, PUTTY AND SAND SMOOTH. AND OTHER WEATHER TIGHT LOCATIONS. A. SONNEBORN'NP2" OR EQUAL. 4. SEALANT TYPE 4: ONE COMPONENT, URETHANE, GUN- GRADES OR POURABLE, SELF - LEVELING FOR INTERIOR AND EXTERIOR HORIZONTAL JOINTS. A. SONNEBORN'SONOLASTiC SL In OR EQUAL. 5. PRIMER: NON - STAINING TYPE, RECOMMENDED BY SEALANT MANUFACTURER TO SUIT APPLICATION. UNPAINTED, POROUS SURFACES SHALL BE PRIMED. 6. JOINT CLEANER: NON - CORROSIVE AND NON - STRAINING TYPE, RECOMMENDED BY SEALANT MANUFACTURER; COMPATIBLE WiiH JOINT FILLING MATERIALS. 7. JOINT FILLER: ASTM D1056, ROUND, CLOSED CELL POLYETHYLENE TAPE RECOMMENDED BY SEALANT TO 50 PERCENT. POLYSTYRENE IS UNACCEPTABLE. 8. BOND BREAKER TAPE: PRESSURE SENSITIVE POLYETHYLENE TAPE RECOMMENDED BY SEALANT MANUFACTURER TO SUIT APPLICATION. 9. CLEAN, PREPARE AND SIZE JOINTS IN ACCORDANCE WiTH MANUFACTURER'S INSTRUCTIONS. REMOVE ANY LOOSE MATERIALS AND OTHER FOREIGN MATTER WHICH MIGHT IMPAIR ADHESION OF SEALANT. METAL SURFACES SHALL BE FREE OF CORROSION. 10. INSTALL JOINT FILLER ROD TO PROPER DEPTH BY ROLLING MATERIAL INTO JOINT WITHOUT LENGTHWISE STRETCHING OR TWISTING. DO NOT PUNCTURE OR PRIME FILLER ROD. 11. SEALANT APPLICATIONS SHALL BE PERFORMED IN STRICT ACCORDANCE WiTH MANUFACTURER'S WRITTEN SPECIFICATIONS BY TRADESMEN SKILLED IN THE WORK. USE MASKING TAPE TO PROTECT ADJACENT SURFACES AS NECESSARY. 12. ALL SEALING SHALL BE DONE WITH NEAT, SMOOTH TOOLED BEADS, FREE OF AIR POCKETS, FOREIGN EMBEDDED MATTER, RIDGES AND SAGS, IN FIRM FULL CONTACT WITH INTERFACES. 13. WORK ADJACENT TO JOINTS SHALL BE CLEANED FREE OF SMEARS OF SEALANT COMPOUND AS WORK PROGRESSES. 1) PARALLEL APPLICATION: 12' O.C. IN FIELD; 8" O.C. ALONG EDGES. ( COORD. W/ WALL TYPES) 2) PERPEND. APPLICATION: 12' O.C. IN FIELD; 12" O.C. ALONG EDGES. ( COORD. W/ WALL TYPES) 6. INSTALLATION OF DRYWALL TRIM ACCESSORIES: A. INSTALL METAL CORNER BEADS AT HORIZONTAL AND VERTICAL EXTERNAL CORNERS OF DRYWALL WORK. SECURE WiTH SCREWS; CLINCHING IS NOT ACCEPTABLE. B. INSTALL METAL CONTROL JOINTS (BEADED -TYPE) WHERE INDICATED AT 30' -0' MAXIMUM CENTERS IN ANY WALL OR CEILING. 7. FINISHING OF DRYWALL: A. APPLY TREATMENT AT GYPSUM BOARD JOINTS (BOTH DIRECTIONS), FLANGES OF TRIM ACCESSORIES, PENETRATIONS, FASTENER HEADS, SURFACE DEFECTS AND ELSEWHERE AS REQUIRED TO PREPARE WORK FOR DECORATION. APPLY JOINT COMPOUND IN 3 COATS. B. STOP MOISTURE - RESISTANT GYPSUM BOARD 12' ABOVE FINISHED FLOOR FOR DUROCK, COMPLY WITH RECOMMENDATIONS OF GYPSUM BOARD MANUFACTURER FOR TREATMENT OF JOINTS. KMOTES JOLOCUS ARCHITECTURE I N C O R P O R A T E D 500 South Dixie Highway, Suite 310 Coral Gables, Florida 33146 Tel (305) 740-0120 Fax (305) 740 -0520 License No. AA0002733 CONSULTANi(S) NO. REVISION/SUBMISSION DATE SPECIAL USE PLANNING 12 -14 -07 BOARD REVIEW PERMIT SET 03 -20 -08 PROJECT Interior Plan for: CAVAS WINE CAFE SOUTH MIAMI MUNICIPAL GARAGE 5829 SW 73rd Street, Units #7 -8 South Miami, Florida 33143 DRAWING Specifications zi �x ,, SCALE ��.•• NTS Q7'er�i t!,L�d1ULr '�i/ p�: DRAWN -:::U, it LM '7 REVIEWED INDL [ °P Si.. :�1{ .• v PROJ. NO. AR 123.0 SHEET NO. SPEC -2.0