08-497-006GENERALSTRUCTURAL NOTES CONTRACTOR NOTES 1. THE CONTRACT DRAWINGS REPRESENT THE DESIRED RESULT OF CONSTRUCTION. THE METHODS OF CONSTRUCTION AND THE RISKS INVOLVED DURING CONSTRUCTION SHALL BE THE CONTRACTOR'S RESPONSIBILITY. THE CONTRACTOR SHALL ALWAYS MAINTAIN THE STRUCTURAL INTEGRITY OF THE BUILDING THROUGHOUT ALL OF ITS CONSTRUCTIONS PHASES. 2. THE CONCTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS PRIOR TO CONSTRUCTION AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT /ENGINEER PRIOR TO COMMENCING ANY PERTINENT WORK. 3. ANY CHANGES OR SUBSTITUTIONS NOT REFLECTED IN THE CONSTRUCTION DRAWINGS SHALL BE APPROVED BY THE ARCHITECT PRIOR TO COMMENCING ANY WORK. 4. CONTRACTOR AND ALL SUBCONTRACTORS SHALL COORDINATE ALL DRAWINGS DURING BIDDING AND SHALL REPORT ANY DISCREPANCIES. IF ANY DISCREPANCIES ARE FOUND DURING CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSAI: ( MEANS (MATERIALS AND LABOR) TO RESOLVE THE DISCREPANCIES. FOUNDATION, FILLING AND EXCAVATION 1. SOIL BEARING CAPACITY = 6,000 P.S.F. 2. ALL FOUNDATION EXCAVATIONS SHALL BE EVALUATED BY A QUALIFIED GEOTECHNICAL ENGINEER TO VERIFY BEARING ON SUITABLE MATERIAL. CAST IN PLACE CONCRETE 1. CONCRETE FOR FOOTINGS SHALL DEVELOP 3,000 P.S.I. COMPRESSIVE STRENGTH IN 28 DAYS. ALL OTHER CONCRETE SHALL DEVELOP 4,000 P.S.I. COMPRESSIVE STRENGTH IN 28 DAYS. 2. REINFORCING BARS SHALL BE DEFORMED AND SHALL CONFORM TO ASTM A615, Fy = 60 K.S.I. REINFORCING BARS INDICATED TO BE WELDED SHALL CONFORM TO ASTM A706. WELDED FABRIC SHALL CONFORM TO ASTM Al 85. 3. SPLICES IN CONTINUOUS VERTICAL OR HORIZONTAL REINFORCING BARS SHALL BE PER ACI 318 -02 OR (40) BAR DIAMETERS LAP SPLICE, WHICHEVER IS GREATER, UNLESS NOTED OTHERWISE AND SHALL BE EITHER CONTINUOUS OR SPLICED WITH DOWELS AT CORNERS. r \ /4. CLEARANCES BETWEEN REINFORCING BARS AND CONCRETE SURFACES SHALL BE AS FOLLOWS. COVER (INCHES) a) CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH -------------- - - - - -- 3 b) CONCRETE EXPOSED TO EARTH OR WEATHER: #6 THROUGH # 18 BARS ---------- - - - - -- 2 #5 BAR AND SMALLER ---------- -- - - -- 11/2 c) CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: SLABS, WALLS, # 11 BAR AND SMALLER ------ 3/4 BEAMS, COLUMNS: PRIMARY REINFORCEMENT, TIES AND STIRRUPS --------------- - - - - -- 1 1/2 STRUCTURAL STEEL 1. ALL STRUCTURAL STEEL SHALL CONFROM TO ASTM A36 UNLESS NOTED OTHERWISE 2. ANCHOR BOLTS SHALL CONFROM TO ASTM A36. 3. ALL CONCRETE STUD AND CONCRETE BLOCK ANCHORS SHALL BE HILTI OR APPROVED EQUAL. 4. ALL BOLTS FOR STEEL BEAM CONNCECTIONS SHALL BE HIGH STRENGTH, A325 AND 3/4' IN DIAMETER, UNLESS NOTED OTHERWISE. 5. ALL HEADED STUD ANCHORS SHALL BE MANUFACTURED BY "NELSON STUD" OR APPROVED EQUAL. 6. ALL WELDS SHALL BE MADE WITH E70XX RODS AND WELDING SHALL CONFORM TO THE LATEST AWS CODE. LIGHT GAUGE METAL FRAMING 1. AS A MINIMUM, STUDS AND/ OR JOISTS AND ACCESSORIES SHALL BE OF TYPE, SIZE, GAUGE AND SPACING SHOWN ON PLANS AND SHALL BE MANUFACTURED BY DALE/ INCOR COMPANY OR APPROVED EQUAL. 2. ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH AMERICAN IRON & STEEL INSTITUTE (AISI) 'SPECIFICATIONS FOR THE DESIGN OF COLD - FORMED STEEL STRUCTURAL MEMBERS ", THE LATEST EDITION. _ -3. ALL FRAMING MEMBERS SHALL BE FROM CORROSION - RESISTANT STEEL, CORRESPONDING TO THE REQUIREMENTS OF ASTM A446 WITH A MINIMUM YIELD STRENGTH OF 50 K.S.I. 4. LGMF SHALL HAVE THE FOLLOWING MIN. PROPERTIES: a) 3 5/8"- 20GA. RUNNER SHALL HAVE THE FOLLOWING MIN. SECTION PROPERTIES UNLESS NOTED OTHERWISE: A = 0.212 IN2 Sx = 0.232 IN3 Ix = 1.428 In4 Rx = 1.483 IN b) 6' - 20GA. RUNNER SHALL HAVE THE FOLLOWING MIN. SECTION PROPERTIES UNLESS NOTED OTHERWISE: A = 0,294 IN2 Sx = 0.465 IN3 Ix = 1.428 IN4 Rx = 2.204 IN c) 3 5/8"- 20GA. STUDS & JOISTS SHALL HAVE THE FOLLOWING MIN. SECTIONS PROPERTIES UNLESS NOTED OTHERWISE: A = 0.297 IN2 Sx = 0.358 IN3 Ix = 0.648 IN4 Rx = 1.478 IN d) 6"- 20GA. STUDS & JOISTS SHALL HAVE THE FOLLOWING MIN. SECTION PROPERTIES UNLESS NOTED OTHERWISE: A = 0.379 IN2 Sx = 0.692 IN3 Ix = 2.075 IN4 Rx = 2.340 IN 5. ALL FRAMING COMPONENTS SHALL BE CUT SQUARELY FOR ATTACHMENT TO PERPENDICULAR MEMBERS OR AS REQUIRED FOR AN ANGULAR FIT AGAINST ABUTTING MEMBERS. 6. AXIALLY LOADED STUDS SHALL BE INSTALLED IN A MANNER WHICH WILL ASSURE THAT THEIR ENDS ARE POSITIONED AGAINST THE INSIDE OF RUNNER WEB PRIOR TO FASTENING. 7. COMPONENTS SHALL BE CONNECTED WITH SELF- DRILLING SCREWS OR WELDING. SCREWS SHALL BE SUFFICIENT TO INSURE THE STRENGTH OF CONNECTIONS. WIRE TYING OF COMPONENTS SHALL NOT BE PERMITTED. WELDS SHALL BE TOUCHED WITH A ZINC -RICH PAINT. 8. LIGHT GAUGE METAL FRAMING AND TRUSSES SHALL BE SIZED BY THE MANUFACTURER. SIZES ON PLANS ARE MINIMUM AND SHALL BE VERIFIED BY MANUFACTURER. SPECIAL INSPECTIONS SPECIAL INSPECTIONS SHALL BE REQUIRED FOR CONCRETE AND TESTING PLACEMENT OF. EXIST. 1 -HR DE PARIIION, SEE ARCHITECTUR/ DRAWINGS FC DETAIL Qr EAST. DEMISING WALL SCALE: 1 1/20=1'-Du 5 X V -0" DOWELS AT O.C. DRILL AND EPDXY TO EXIST. CONCRETE W/ MIN. EMBED. EXIST. CMU WALL FILL WITH JOINT FILLER FLUSH WITH TOP OF CONCRETE SLAB 1 #5 CONT., E.F. 8" X 12' THICKENED EDGE DETAIL EXIST. CMU WALL SCALE: 1 1/2'=V-0l 1 #4 CONT., E.F. 3 o 0 CONC. SLAB, U U_ SEE PLAN COORD. W/ PLUMB. 8 zd SHEETS DETAIL @ FLOOR DRAINS & DEPRESSED AREAS SCALE: 1 1/2"=V-0' DETAIL CONTROL JOINTS SCALE: 1 1/2"=V-0" NEW CONC. SLAB, SEE PLAN FOR DETAILS 8' EXIST. CONC. SLAB, SEE PLAN FOR DETAILS SAW CUT OR USE 1/8N PREFORMED INSERT AT ALL CONTROL JOINTS, FILL WITH JOINT FILLER FLUSH WITH TOP OF CONCRETE SLAB ( *SAW CUT JOINT WITHIN 12 HOURS OF POURING CONC.) CONC. SLAB, SEE PLAN FOR DETAILS VAPOR BARRIER CRUSHED STONE #5 X V -0" DOWELS AT 12" O.C. DRILL AND EPDXY INTO EXIST. CONCRETE W/ MIN. 4' EMBED. DETAIL Cad NEW &EXISTING CONIC. SLAB SCALE: 1 1/2'=V-0" iii I� INDICATES SLAB DEPRESSION AT _ FLOOR DRAINS Imo\ j LSEE DETAIL 3/S -1.0 M. 6' RAISED CURB @ JANITOR'S MOP SINK, COORD. W/ ARCH. DRAWINGS DEPRESSED SLAB MIN. I- RECESS SLAB FOR 4' COORD. W/ COOLER/ PIVOT DOOR HARDWARE FREEZER ML .0 ANUF COORD. W/ SPECS. SEE DE 4 FLOOR S 1.0 OUTLET & DATA 3 S-1.0 (E2 .0 FLOOR OUTLET COORD. POWER AND PLUMBING W/ ENOMATIC PRODUCT SPECIFICATIONS AND MEP SHEETS, TYP. 6-8' MUNnAT1ON PLAN SCALE: 1/40=1'-O" zo FLOOR OUTLET & DATA co ;o i 3' -0' 7'-6" 0 i+) FLOOR OUTLET A FLOOR OUTLET o I 5' -0' 5 FLOOR MUST BE ES-11 SMOOTH AND LEVEL TO ACCEPT VINYL FLOORING 2, -6. v FLOOR OUTLET CONTROL JOINT, TYP. SEE DETAIL 2/S -1.0 m TYPICAL SLAB CONSTRUCTION W CONC. SLAB REINF. W/ 6 X 6- W2.9 OVER 6 MIL VAPOR BARRIER OVER 5" COMPACTED #57 CRUSHED STONE, TYP. FLOOR OUTLET 0 v FLOOR OUTLET ' -0" 4' -1 COORD. POWER AND PLUMBING W/ ENOMATIC PRODUCT SPECIFICATIONS AND MEP SHEETS, TYP. EXIST. CONC. v FOOTING TO REMAIN in JOLOCUS ARCHITECTURE I N C O R P O R A T E D 500 South Dixie Highway, Suite 310 Coral Gables, Florida 33146 Tel (305) 740-0120 Fax (305) 740-0520 License No. AA0002733 CONSULTANT(S) NO. I REVISIONISUBMISSION DATE SPECIAL USE PLANNING 12 -14 -07 BOARD REVIEW PERMIT SET 03 -20 -08 PROJECT Interior Plan for: CAVAS WINE CAFE SOUTH MIAMI MUNICIPAL GARAGE 5829 SW 73rd Street, Units #7 -8 South Miami, Florida 33143 DRAWING Foundation Plan & Details SEI`f SCALE 1/4 " =1' -0' .w DRAWN �•' BG REVIEWED NDL •N•��lbdiOG''Ort' PROD. NO. AR '13937 ' 123.0 NORTH SHEET NO. S -01