07-1406R-00212' X 24' FILTER SECTION A FUSIBLE LINK DETECTOR 1 /2N 1 /2N SUPPLY /LINE 1 /2N 1 /2N APPLIANCE Q BRANCH LINE 3 GAL. AGENT TANK LOCATED OPPOSITE TO ACCESS DOOR 12' X 24' FILTER SECTION ,. E- -T FILTER SECTION FUSIBLE LINK DETECTOR INLET PLENUM: 45x14 UP THRU — FLOOR AP -f 3Cx30 CHAINLINK FENCE AROUND GREASE EXHAUST UNIT BY GENERAL CONTRACTOR cc -C TRANSITION: FLAT ON BOTTOM AND, ECCENTRIC ON QTHER--_' THREE SIDES 50x24 /—AP--F\ L 48x48 (–Y,—,30 V-a12 GREASE EXHAUST UNIT LOCATIONS SCALE: 1/4"=V-0" THE ANSUL R -102 FIRE SUPPRESSION SYSTEM IS PROTECTING WITH ONE 3,OGAL, AGENT TANK, THIS SYSTEM IS USING 4 FLOW POINTS OUT OF THE 11 POSSIBLE FLOW POINTS, - O O C! O � 0 a n 4 � CJ FFF G F i O FFFF T O r� l�700000d REM C- fEmu MOMMIIMF-,' 7 ®0 ® ©QOQQW =�G -� SECOND FLOOR EQUIPMENT KEY PLAN N SCALE: 1/32"=l'-O" NOZZLE PLACEMENT REQUIREMENTS - HAZARD MAXIMUM HAZARD NOZZLE NOZZLE NOZZLE TIP TOTAL NUMBER ITEM NOZZLE DIMENSIONS QTY. PART No. STAMPING— OF FLOW POINTS HEIGHT FLOW No. ELECTROSTATIC INDIVIDUAL CELL 8 419334 y2 N 4 - - - - - -- PRECIPITATOR O DISTRIBUTION PIPING REQUIREMENTS DISTRIBUTION PIPING REQUIREMENTS — 3.OGAL. AGENT TANK (EA.) REQUIREMENTS SUPPLY /LINE DUCT PLENUM APPLIANCE BRANCH LINE BRANCH LINE BRANCH LINE PIPING SIZE 3/g in. 3/g in. 3/g in. % in. MAXIMUM LENGTH 40 ft. 8 ft. 4 ft. 12 ft. MAXIMUM RISE 6 ft. 4 ft. 2 ft. 2 ft. MAXIMUM 90° 9 4 4 6 ELBOWS MAXIMUM TEES 1 2 2 4 MAXIMUM FLOW 11 4 2 4 NUMBERS GENERAL NOTE: 1.- SYSTEM SHALL BE PROVIDED WITH A LOCAL INDICATOR/ALARM AND WITH ARELAY TO SHUT DOWN SUPPLY FAN WHEN SYSTEM IS ACTIVATED TURN ON EXHAUST FAN, AND SHUT OFF ALL ELECTRIC UNDER HOOD. (BY OTHERS) 2. -PIPE SHALL BE 3/8" SCHEDULE BLACK IRON. 3.- BALLOON TEST TO BE PERFORM TO ENSURE SYSTEM FUNCTIONS PROPERLY. (NITROGEN WILL BE BLOWN THROUGH THE LINES TO VERIFY PIPING IS UNOBSTRUCTED) 4.- INSTALLATION COMPLIES WITH NFPA 17A AND NFPA 96. 5. -ONLY MANUFACTURES LISTED COMPONENTS USE FOR AND WITH THIS SYSTEM. 6: \N�RE I�NO GAS ASSOC ATED WITH THIS NIT. 8.-- �RFASE`TjGH FI I(�S. T 8. -THIS IS AN EXHAUST UNIT THAT DOES NOT HAVE A FRYER AND THEREFORE SHOULD NOT REQUIRE A K -TYPE FIRE EXTINGUISHER. TO %" EMT TO ANSUL R -102 REGULATED AUTOMAN RELEASE ASSEMBLY APPROVISO i ii -DADS COUNTY FlItE ntPA -R ?4ENr SLW. PERMIT ,�-- FIRE AIAAM.,,a FIRE SU?PRESSI0N OATS: /.2e� �, BYE�� _.�.... __,.. _.. ..�., TYPICAL INSTALLATION ONE 3,0GAL A TANK Q — °0 CARRABBA'S DD < 5829 SW 73rd Street, Suite #102 ry Miami, Florida, 33143 Q c� SCALE AS SHOWN w Q DATE JULY 10, 2006 z I� ANSUL R -102 SYSTEM L' I ONE 3.0 GAL AGENT TANK DRAWN BENY NAJARRO REVISED NOVEMBER 14, 2007 SHEET 2 OF 3 SHEETS