07-1406-001I' II i I a I DUCT, x 8" II � ANSUL R -102 F.S.S. LOCATED INSIDE AFIRE CABINET '�' LOCATED AT END ~ ` GTt OF HOOD ,- r,DUCTt 11" x 12" 1 i F`. i _� 1 •` 3 ` DUCTi 10' Q I 6 a • ,y • `\��` I ' /fig DUCTt 10" x 8" °LFZ• �`.� Q /T. DUCTt 3 0 i 1' 10" x 8" / DUCT, C -�10" x 8" a -- KITCHEN HOOD EIRE SUPPRESSI ❑N SYSTEM Y2" EMT TO 3/8" PIPE ANSUL PULL TO NOZZLE STATION 3/8" PIPE TO NOZZLE /2" EMT TO FUSIBLE LINK DETECTORS 1 3/8" PIPE TO NOZZLE 3.0 AGENT TANK 3.0 AGENT TANK 3.0 AGENT TANK ANSUL R -102 REGULATED AUTOMAN RELEASE ASSEMBLY 51P�zr1'r'w'TE;,! TO BE ItISTE1.L151a fix': r;��f�� a � ry TYPICAL INSTALLATIDN FOUR 3,OGAL AGENT TANK ease* *sees . 0 ••••• 000 • • • • • • • • • Y Y • • Y ♦ Y Y Y • W ••• •0• • • • •Y•• • • • •Y• •Y• ♦•♦ • • r ii•♦ Y•••Y •rY •0•• Y W 4 • • • • YYr♦ • • Y Y Y • ♦ Y • r Y Y • r • • • W••• • r• ♦•• • •Y• • 0000 • NOZZLE PLACEMENT REQUIREMENTS HAZARD MAXIMUM HAZARD NOZZLE NOZZLE NOZZLE TIP TOTAL NUMBER ITEM NOZZLE DIMENSIONS QTY. PART No. STAMPING— OF FLOW POINTS HEIGHT FLOW No. DUCT LENGHT—UN LIMITED 7 430912 1W 7 - - - - - -- PERIMETER -50in DIAMETER -16 in PLENUM LENGTH — 10FT. 5 419335 1 N 5 O — — — — — — — RANGE LONGEST SIDE — 28in. 16 419333 1F 16 FL 33166 592 -5254 40 — 48 In. AREA -336 in. 5829 SW 73rd Street, Suite #102 Miami, Florida ,33143 GRIDDLE LONGEST SIDE — 36in. 2 419335 1N 2 0 35 — 40 in. AREA -1080 in. SYS. ANSUL R -102 FIRE SUPPRESSI ❑N SYS. FRYER MAXIMUM SIZE: 3 419339 230 6 0 27 — 47 in. 151in. X 141n. TILT BRAISING MAXIMUM SIZE: 3 419338 3N 9 21 — 34 in. PAN 25—j" in. X 19—j" in. (Fry pot side must not exceed 19 —j" x 19 in. DISTRIBUTION PIPING REQUIREMENTS DISTRIBUTION PIPING REQUIREMENTS — 3.OGAL. AGENT TANK (EA.) REQUIREMENTS SUPPLY /LINE DUCT PLENUM APPLIANCE BRANCH LINE BRANCH LINE BRANCH LINE PIPING SIZE 3/a in. 3/g in. 3/a in. 3/8 in. MAXIMUM LENGTH 40 ft. 8 ft. 4 ft. 12 ft. MAXIMUM RISE 6 ft. 4 ft. 2 ft: 2 ft. MAXIMUM 90" 9 4 4 6 ELBOWS MAXIMUM TEES 1 2 2 4 MAXIMUM FLOW 11 4 2 4 NUMBERS GENERAL NOTE: 1.- SYSTEM SHALL BE 'PROVIDED WITH A LOCAL INDICATOR /ALARM AND WITH A RELAY TO SHUT DOWN SUPPLY FAN WHEN SYSTEM IS ACTIVATEDTURN ON EXHAUST FAN, AND SHUT OFF ALL ELECTRIC UNDER HOOD. (BY OTHERS) 2.- KITCHEN FIRE SUPPRESSION CYLINDER ASS'Y SHUT OFF GAS VALVE TO BE INSTALLED IN AN ACCESSIBLE PLACE BELOW CEILING. 3.- PIPE SHALL BE 3/g" SCHEDULE BLACK IRON. 4.- ONE EXTINGUISHER LISTED AND LABELED REQUIRED FOR CLASS "K" USE. EXTINGUISHER WILL BE LOCATED WITHIN 30FT. OF COOKING HOOD AS PER FLORIDA FIRE PREVENTION CODE. 5.- BALLOON TEST TO BE PERFORM TO ENSURE SYSTEM FUNCTIONS PROPERLY. (NITROGEN WILL BE BLOWN THROUGH THE LINES TO VERIFY PIPING IS UNOBSTRUCTED) 6,- INSTALLATION COMPLIES WITH NFPA 17A AND NFPA 96. 7. -ONLY MANUFACTURES LISTED COMPONENTS USE FOR AND WITH THIS SYSTEM. 8.- IN AREA OF PENETRATION, CONDUIT AND PIPING WILL HAVE GREASE TIGHT FITTINGS. �Pa 7 tea{ �t7 11zr :.2 LTA, M M i47"141131EX7Dt lz��I. U z U-1 J n le Fire, Tr a Inc. 7720 N.W. 53rd Street, Miami, ' 592-3011, Fax: (305) FL 33166 592 -5254 (305) CARRABBA'S 5829 SW 73rd Street, Suite #102 Miami, Florida ,33143 SCALE AS SHOWN DRAWN ORLANDO ALFONSO DATE JULY 10, 2006 REVISED 10/24/2007 KITCHEN HOOD FIRE SUPPRESSI ❑N SHEET SYS. ANSUL R -102 FIRE SUPPRESSI ❑N SYS. 1 WITH FOUR 3.OGAL, AGENT TANK, OF 3 SHEETS F6R� s PA�*wa a < , < I