Loading...
07-1401-005FLEX DUCT AIR FL T,4. PROVIDE VOLUME CONTROL DAMPER 0 FLEX DUCT CONNECTION ON LAYIN CT AIR FLOW DIFFUSER. (TYPICAL) BRANCH 'FAKE -OFF DETAIL NO SCALE UNIT UPLIFT CALLS ACCU -1 F ACCU -1 —===4> � n I cv W-4650 tc' SIDE AREA OF UNIT : 24'x(32' +18') - 83 SOFT. 144' VELOCITY PRESSURE: ASCE -1 140 MPH Hs 22' -0' MWFRS Ial C140.00256)1085) lU 1140)? C1) Cj -42b PSF, P- (0.8+0.5)X4210 P6F (WINDWARD+ LEEWARD) P =5538 PSF. F -(83 OF x5538 PSF) ■459 .60 Mo =459.60 x 2.1'= 96510 -1 T- C- 96520-1 /2'- 482.60 UPL IFT ON TOP- 24'x24' ,x ( -0.9) x 42.6 - -15630 144 NET UPLIFT - 15630 -1330= 2330 MIN. ANCHOR 0 EA CORNER = 2 ! +_4$2k"- 126,5* 0 4 4 DOWN LOAD a EA CORNER- I"_ +_4jN_rk - 214.6. 4 4 2 EQUIPMENT TIE-120K • DOWNWARD SUPPORT a EA CORNER= 214100 UPWARD SUPPORT a EA CORNER ■ 126.50 -2010 SCREWS TO STRAP * EA CORNER - 400 0 IS OK -1/410 TAPCON = 2500 is EA COMER IS ALSO OK )mss. "CAL Z -Ali HANG DUCTS ACCOWM AND LURE DUCT TO SHACNA STANDARDS L HANGQ14 DETAIL STATIC PRES. CONDENSING TYPICAL. HAN4RJG STRAW AND SADDLE tYPiCAI. CHANNi:I. AND STRAP DUG? HANGM DETAIL NANOWs DETAIL. ALL STRAPS TO 13E 14#2',26 GA. GALV. STEEL W -0' 0jM MAX. SPACM4 METHODS OF HANT,ING DUCTS DETAIL A/ C UNIT 2' MIN. AROUND PERIMETER, TYP. 1'x12' 16 GA MTL _ STRAP. ONE AT EVERY CORNIER 2 -812 SHEET MTL SCREWS PER STRAP I/4' TAPCON THK CONC. PAD, GRADE 9 , a a W.4' 4. a a a ....�+...�...�.�. a C OND . PAD DETAIL NOT TO SCALE NOTE, SMOKE (DUCT) DETECTOR TO BE CONNECTED TO BUILDING FIRE ALARM PANRL / SYSTEM SYMBOL/LEGEND: CEILING RETURN AIR GRILL - j SIB WALL DIFUSSER AIR FLOW SIZE (24x24) MULTIDIRECTIONAL AIR FLOW (200 CFM) CEILING DIFFUSER (TYP -) ,,......., SUPPLY ��► • MAX. LENGTH 14' �.�� FLEX DUCT '''•....•'' 400 RETUR \ MAX. LLEN GTH 14' FLEX DUCT 44 SIZE CIRCULAR AIR DIFFUSER AIR FLOW ----- ROUND SHEET METAL DUCT IN AIR CONDITIONED SPACE SUPPLY AIR DUCT 18 X 14 12x14 8x14 SUPPLY AIR DUCT NOTE. ALL SUPPLY DUCTS TO HAVE R -6 INSULATION VALUE 4 EXHAUST FAN O THERMOSTAT a 48' AFF W /SHUT OFF t SET BACK SD SMOKE DETECTOR MANUAL VOLUMEN DAMPER FLOOR SLAB d. d n tOTHREADED RED- HEAD FASTENER HDI 1/4' No 00045752 - FLUSH ANCHOR BY HILTI ALLOWABLE WORKING LOADS CONCRETE 570 LB 2 TENSION OTHREADED COUPLING 03 THREADED ROD UNDER SLAB AHU D -I SUPPORT NO SCALE PP -HANG1 POWER ACTUATED PIN �- CONCRETE PECK 1' WIDE 26 GA STRAP FLEX- DUCT FLEXIBLE DUCT CONNECTION DETAIL FNAC NOTES: 1. HvAC SUBCONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS TOOLS AND EQUIPMENT TO INSTALL A COMPLETE AND OPERATIVE A/C SYSTEM. 2• HvAC SUBCONTRACTOR TO PROVIDE ALL REQUIRED HVAC PERMITS 3. HvAC SUBCONTRACTOR SHALL PROVIDE ALL EQjIPMI =NT OF t HE CAPACITIES SHOWN ON PLAN. 4. COMPLY WITH NFPA, FLORIDA BUILDING CODE, AND ALL APPLICABLE CODE$. 5- OUTSIDE AIR DUCT SMALL BE GALVANIZED SHEET METAL, CONISTRUCTED AND INSTALLED IN ACCORDANCE WITH ASHRAE AND SMACNA STANDARDS. 6. ALL AIR DEVICES SHALL BE ALUMINUM CONSTRUCTION. 1. HVAC SUBCONTRACTOR SHALL TEST AND BALANCE TO THE AIIR QUANTITIES SHOWN ON THE PLAN. 8. HvAc SUBCONTRACTOR SMALL PROVIDE ALL CONTACTORS, R?ELA'S AND THERMOSTATS. THE ELECTRICAL SUBCONTRACTOR SHALL PROVIDE ALL SWITOHES, DISCONNECTS AND CONTROL WIRING. T14ERM06TATO SHALL BE AS RECOMMENDED BY EQUIPMENT MANUFACTURER 9- ALL SUPPLY t RETURN DUCTWORK SHALL BE CONSTRUCTED OIF 111/2' THICK STANDARD DUTY FIBERIGLASS BOARD WITH REINFORCED FLAMEPROOF ALUMINUM FOIL FACED COVERING, R -6 MIN. INSULATION, ALL DUTY SIZES ARE CLEAR INSIDE DIMENSIONS. (SMACNA STANDARDS) (UON) FLEXIBLE DUCT RUN OUTS SHALL BE ROUND DUCTWORK REINoRCED WITH A WIRE HELIX AND INSULATED WITH 1' THICK FIBERGLASS COVERED WITH A VAPOIR BARRIER OF ALUMINUM METALIZED POLYESTER FILM LAMINATED TO GLASS MESH. wto NECTIONS TO DUCT MAINS SHALL BE MADE WITH FITTING PROVIDED WITH TWIST RINGS, BUTtTERFLY DAMPERS, QUADRANT OPERATORS AND INSULATION GUARDS. 10. THE HVAC SUBCONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE THAT SHALL WARRANT ALL WORKMANSHIP AND MATERIALS FOR ONE (1) YEAR FROM THE DATE OF FINAL WORK ACCEPTANCE BY OWNER ANY BREAKDOWN OCCURRING IN THE FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE TO THE OWNER THE COMPRESOR("3) SHALL HAVE AT FIVE (5) YEAR WARRANTY. 11. ALL WORK OF THIS TRADE SMALL BE COORDINATE WITH ALL OTHER TRADES TO AVOID INTERFERENCES THAT MAY DELAY PROGRESS OF WORK 12. FILTERS SHALL BE DISPOSABLE TYPE AND HAVE INITIAL SHARE WEIGHT AND RESISTANCE OF 10% AND A CLEAN PRESSURE DROP OF 0.15. PROVIDE TWO SETS, ONE DURING CONSTRUCTION AND OTHER FOR USE AFTER OCCUPANCY. 13. MVAc SUBCONTRACTOR SHALL INSTALL ALL NECESSARY OFFSETS, BENDS AND TRANSITIONS REQUIRED TO PROVIDE A COMPLETE SYSTEM AT NO ADDITIONAL COST TO THE OWNER 14. COORDINATE LOCATION OF CEILING DIFFUSERS, GRILLS t RE(I ISTERS IN THE FIELD WITH LIGHTING AND ARCHITECTURAL ELEMENTS. 15, MOUNT ALL EQUIPMENT FOR WIND LOADS AND MOUNTING HEICtHTS AS REQUIRED BY LOCAL CODES. 16. MECHANICAL CONTRACTOR SMALL COORDINATE W/ PLUMBINGI CONTRACTOR CONDENSATE SYSTEM INSTALLATION ( TO BE PROVIDED t INSTALLED BY P'LUM131NG CONTRACTOR). 11. REFRIGERANT SUCTION PIPING t CONDENSATE DRAIN LINES SHALL BE INSULATED W/ 3/4' FOAM PLASTIC PIPE INSULATION 18. MECH- SUBCONTRACTOR SHALL INSTALL CONDENSATE DRAIN ILINES/PI.IMPS AS SHOWN ON PLANS IMPORTANT NOTE: INSTALL A.H.U. AS TIGHT AS POSSIBLE TO DRYWALL LID d . d d . d CONCRETE SLAB ESTRUCTURAL ABOVE WTTOM OF GONG DECK q o d o / \ SMOKE DETECTOR FIRE LID D -I IN UNITS EXEEDING TYP OF 4 2000 CFM 36 --- - - - - -- ------ - - - - -- - - ' MIN. - - - - - -- � -- - -- : _ r I II I I i i i i VIBRATION ISOLATOR SUPPLY i i I .HEATER A.H.U. I I I 3/8' ALL THREAD ROD / L-- AS SCHEDULE C FLEXIBLE CONNECTION, TYP. 1 i RETURN 111 TYP OF 4 L 'FLOW SWITCH' 211/2' STL STRUT (UNIT TO SHUT DOWN, IF FULL) AN INSULA D CONDENSATE W/ AUX. DRAIN LINE DRAIN INE BOTT. OF CEILING III I 1 11 I 111 1 1 SEE SCHEDULE TILE SYSTEM SUSPENDED CEILING AHU MOUNTING DETAIL SCALE p SPLIT SYSTEM AIR CONDITIONING SCHED L"E'z�= �✓ SYSTEM STATIC PRES. CONDENSING VOLT. /PH RPM SENSIBLE MODEL TOTAL TOTAL CLG. -TD. HTR 02 5 ENT, COND. REMAF No. MANUFAC, QT80 UNIT A.N.U. NO BTU w� BTU CFM WEIR KW. VOLT/PMASE TW V b ►-� � H c 11 A/C -1 CARRIER 3ARZO01 -5 40RM001 -06 54AOO 11,600 2,400 11.0 10 208/240/3 PH D J ) 61 NOTESs THERMOSTAT , MUST BE PROGRAMMABLE EXHAUST FAN SCHEDULE FAN No. TYPE CFM STATIC PRES. HP VOLT. /PH RPM MANUFACT. MODEL REMARKS EF -1,2 CLG. -TD. 50 02 5 4S WATTS 120/1 g50 NUTONE QT80 l, 2, OUTSIDE AIR CALCULATIONS THE FOLLOWING OUTSIDE AIR QUANTITIES ARE CALCULATED IN ACCORDANCE WITH ASNRAE 62 -1WS UNIT TAG AREA SERVED ROO AREA TOTAL PEOPLE CFM PER PESON CFM O/A REQD. AHU -1 OFFICE SPACE 250 7/1000 =2 PEOPLE 20 CFM 35 REDUCING SALONS 811 2011000 -l8 PEOPLE 15 CFM 262 NO 291 TOTAL CFM HVAC DESIGN REQUIRES YES NO DUCT SMOKE DETECTOR YES FIRE DAMPERS NO SMOKE DAMPERS NO FIRE RATED ENCLOSURE » z NO FIRE RATED ROOF / FLOOR CEILING ASSEMBLY NO FIRE STOPPING NO SMOKE CONTROL � NO NEW CONNECT EA. TO EXISTING 12' x 12' WALL LOUVER I 1 4' MTL 6' * MTL COMPRESSOR UNIT 0 2ND FLOOR GARAGE LEVEL l AREA DESIGNED FOR THIS USE ON 'SHELL' PERMIT _0_1} H-0 d CONNECT TO EXISTING 3' m C0ND c,ITY car- SOU ftl MIAMI BUILDING WEP r- I M FlC,IIANICAL S8CI10N / �FPROVEo BY: �_� - - - - -� - 7 CATE: - - -- ---- - - - - -- __ _. MECHANICAL PLAN &,µE ,, . m j, GUTIERRE7 & LOZANO ARCHITECTS 2830 W. STATE ROAD 84, SUITE117 FT. LAUDERDALE, FL. 33312 PHONE: (954) 321-3442 FAX: (954) 321-3864 REVISIONS MA'1o'E.L GUTIERRg7, STAT OF FLA., RE& ; No. 8253. E' CARLOS LOZANO' D STATE OF FLA.,-'REG. No. 0014722 , SHEET TITLE : MECHANICAL PLAN JOB No.: DATE: 10/17/07 SHEET M -1 OF Draw. ADRIANA C. Fltne6sll DU » z N� W ^ W � W w� E__4 f: TW V b ►-� � H c O � � z H �Z^I E-+ 00 4 U7 cn SHEET TITLE : MECHANICAL PLAN JOB No.: DATE: 10/17/07 SHEET M -1 OF Draw. ADRIANA C. Fltne6sll DU