5928 SW 66 ST ERPB-02-008-008 C14 CD c\1 L0 O Q o U ❑ r Y U O W ❑ U PLUMBING NOTES M M Q `Y' 1. ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE LATEST 22. PLUMBING FIXTURES SHALL COMPLY WITH WATER CONSERVATION Q EDITION OF THE "SOUTH FLORIDA BUILDING CODE", THE NATIONAL FS.553.14 {n 23. CONTRACTOR SHALL CONNECT WATER AND WASTE TO EQUIPMENT FURNISHED LU PLUMBING CODE" AND ALL APPLICABLE LOCAL ORDINANCES. BY OTHERS AS' REQUIRED FOR COMPLETE OPERATION. Z w 2. CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY FAMILIARIZE 24. CONTRACTOR SHALL GUARANTEE ALL WORK FEE FROM DEFECTS OF HIMSELF WITH AND VERIFY ALL EXISTING CONDITIONS AND REPORT ANY WORKMANSHIP AND/OR MATERIALSFOR A PERIOD OF ONE YEAR FROM O m L DISCREPANCIES TO THE ARCHITECT/ENGINEER PRIOR COMMENCING WORK. DATE OF ACCEPTANCE. ® LLI 25. ALL HOT WATER PIPES SHALL BE INSULATED WITH A 1/2" THICK GLASS FIBER {/' f7l 3. THE CONTRACTOR SHALL COORDINATE THE WORK OF THIS TRADE WITH ALL MOLDED INSULATION. WITH PRE-SIZED FACTORY APPLIED FRJ JACKET OF _ ® 0 OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF GLASS CLOTH WITH LONGITUDINAL LAP AND BUTT JOINT STRIPS WITH SELF � CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE ARCHITECT/ SEALING ADHESIVE. > 0- O ENGINEER. 26. ALL A/C CONDENSATE DRAIN LINES ABOVE GRADE SHALL BE INSULATED W _j 4. REQUIRED INSURANCE SHALL BE PROVIDED BY THIS CONTRACTOR FOR WITH 1/2" ARMAFLEX PIPE INSULATION. SEAL ALL SEAMS WITH �, LLI n PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE INSULATION MANUFACTURER'S SOLVENT. NO TAPES ARE ALLOWED C.0 Z DURATION OF WORK. 27. WATER HEATER SHALL BE INSTALLED WITH A HEAT TRAP AND ALSO opt PROVIDE A STUB OUT FOR S FUTURE SOLAR OR HEAT RECOVERY SYSTEM. COVERED TERRACE 5. ALL PERMITS, FEES, INSPECTIONS AND TESTS SHALL BE THE 28. INSULATE ALL HANDICAPPED LAVATORIES, EXPOSED DRAINS AND WATER Q RESPONSIBILTY OF THE PLUMBING CONTRACTOR. PIPING TO PROTECT AGAINST BURNING AND/OR CUSHION IMPACT. USE MASTER BEDROOM 6. THE CONTRACTOR SHALL VERIFY ALL THE DIMENSIONS WITH THE ARCHITECTURAL HANDI LAV-GUARD" INSULATION KIT OR APPROVED EQUAL. COORDINATE PLAN. COLOR WITH ARCHITECT. 7. ALL MATERIALS SHALL BE NEW AND OF AN AMERICAN MANUFACTURER, 29. PIPING MATERIALS `Q FREE FROM DEFECTS, INDELIBLY MARKED WITH THE NAME OF MANUFACTURER, SANITARY AND GREASE WASTE: WEIGHT AND/OR CLASS. 8. ALL WORK SHALL BE PERFORMEDBY A LICENSED PLUMBING CONTRACTOR CAST IRON DRAINAGE PIPE AND FITTINGS: IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY 1. HUB AND SPIGOT: SERVICE WEIGHT CENTRIFUGALLY SPUN CAST IRON, HUB OPERATIVE. AND SPIGOT, TAR COATED INSIDE AND OUT, ASTM A74. (BELOW GROUND) 9. ALL EXCAVATION, BACK FILL AND PATCHING THE SLAB SHALL BE PART OF 2• NO HUB: SERVICE WEIGHT CENTRIFUGALLY SPUN CAST IRON, NO HUB, TAR THIS CONTRACT. COATED INSIDE AND OUT, CISPI 301. (ABOVE GROUND) 10. VERIFY LOCATION, SIZE AND ELEVATION OF ALL UTILITIES PRIOR TO CAST IRON PIPE JOINT: DINING/FAMILY ROOM BEGINNING CONSTRUCTION, ADVISE ARCHITECT/ENGINEER OF ANY DISCREPANCIES. 1. NO HUB 11. DRAWINGS ARE DIAGRAMATIC. DO NOT SCALE DRAWINGS FOR THE EXACT 2. NEOPRENE GASKET: ASTM C564 2 LOCATION OF FIXTURES AND ITEMS. 3. STAINLESS STEEL CLAMP AND SHIELD ASSEMBLY: 300 SERIES, CISPI 301-69T X rn GO 12. STOPS SHALL BE PROVIDED AT PLUMBING FIXTURES. �I 3° SWEAT PROOFING: 13. PROVIDE AIR CHAMBER 18" HIGH, NEXT SIZE LARGER THAN PIPE SWEAT PROOF HORIZONTAL DRAINAGE PIPING BETWEEN DRAIN AND VERTICAL W.[.C,. SERVING THE FIXTURE. (UNLESS OTHERWISE INDICATED) LEADER RUNNING IN CONDITIONED AIR SPACE OR PLENUMS WITH 1/2" THICK SA ET LASS GLASS FIBER SECTIONAL PIPE COVERING WITH FLAME RETARDANT VAPOR 22'x36° 14. PROVIDE DIALECTIC UNIONS WHERE DISSIMILAR METALS ARE JOINED. BARRIER JACKET. ATTIC ACCE66 15. ESCUTCHEONS SHALL BE CHROME PLATED BRASS WITH LOCKING SCREWS LAUNDR,r WHERE PIPES PASS THROUGH FINISHED WALLS. COPPER TUBING: 16. A CLEAN OUT SHALL BE PROVIDED AT THE BASE OF EACH SOIL AND WASTE TYPE "K" OR "L": SEAMLESS HARD DRAWN OR ANNEALED, ASTM B88 1e J STACK. TTPE DWV: SEAMLESS HARD DRAWN, ASTM B306 AHU, 17. ALL HORIZONTAL BRANCHES, SEWER AND DRAIN LINES, 3" AND LARGER, SHALL - 50 gale. WH I' DR41N BE SLOPED A MINIMUM OF 1/8 INCH PER FOOT UNLESS OTHERWISE INDICATED DOMESTIC WATER SUPPLY PIPING: Lo UNDER A/C A. ABOVE GROUND: COPPER TUBING TYPE "L" WITH BRONZE OR WROUGHT co ON PLANS. COPPER SOLDER JOINT FITTINGS. 18. EVERY FIXTURE CONNECTED TO THE DRAINAGE SYSTEM SHALL BE B. UNDERGROUND: TYPE "K" SOFT TEMPERED COPPER WITH CAST BRONZE A/C UNI T COMP. EQUIPPED WITH A WATER SEAL TRAP. OR SOLDERED JOINT FITTINGS. UNIT 19. EACH HOSE BIBB SHALL BE KEY OPERATED TYPE, FURNISHED WITH A 0 2 e VTR 3° VACCUM BREAKER AND SHUT OFF VALVE. 1!® O O I D� I 120. PRESSURE AND TEMPERATURE RELIEF LINES SHALL BE PROVIDED FROM WATER HEATERS, DISCHARGING AT JANITOR'S SINK PER SOUTH FLORIDA BUILDING CODE 4614.18 (F)(2) KITCHEN BEDROOM 21. ALL EXPOSED PIPING WITHIN TOILET ROOMS SHALL BE CHROME PLATED. w UL 0 4'x5' g \ CONC. SLA5 REF. PANTiRY 3° LL 10 41& LL ki LL 2° 2' AFE Y GLASS 3' 2° 3° VTR LL 0 0 LL LIVING; ROOM BEDROOM 4° TO SPUER-i act 0 J FL UM5 f NG FLAN N W 1/4 _ 11-0" Z I- SHEET: OF: f L) Lu ry IL (J LlJ J LL