5928 SW 66 ST ERPB-02-008-006
a N ®p3 Lll O` m.7 J / A® 2 ° GENERAL ELECTRICAL MOTES : ® / ELECTRICAL SYMBOL LIST: o 1.0 - GENERAL / A-� PA-1 L0 z w 1.1 - WORK INCLUDED UNDER THIS DIVISION CONSIST OF PROVIDING LABOR MATERIALS, A_2 -, 3 W. GROUNDED DUPLEX RECEPTACLE 20 A. 120 V. M.H.+12" A.F.F. W APPLIANCES, EQUIPMENT, TOOLS, TRANSPORTATION, SUPERINTENDENCE AND SERVICES REQUIRED / Q = c1r) TO CONSTRUCT AND INSTALL COMPLETE AND PROPER OPERATING ELECTRICAL SYSTEMS / 3 W. GROUNDED SINGLE RECEPTACLE 30 A. 240 V. M.H.+12" A.F.F. U AS SPECIFIED, INDICATED AND ELSEWHERE REQUIRED. 2.0 - EXAMINATION OF SITE COVERS TER ACE I 3 W. GROUNDED SINGLE RECEPTACLE 60 A. 240 V. M.H.+12" A.F.F. 2.1 - BIDDER IS ADVICED TO VISIT THE SITE AND ACQUAINT HIMSELF WITH WORKING CONDITIONS. A_& PUSH BOTTON CONTRACTOR SHALL ACCEPT CONDITIONS AS THEY EXIST ON BID DATE. I G.F.I. M,45TER SEDIRCOM I 3.0 - MATERIALS UJ.P. Q JUNCTION BOX CIELING OR FLOOR MOUNTED chi 3.1 - MATERIALS, EQUIPMENT AND APPLIANCES SHALL BE NEW AND OF BEST QUALITY I ® c+7 UNLESS OTHERWISE INDICATED. �4 / A_1 FO JUNCTION BOX WALL MOUNTED M.H. AS DIRECTED Cr) 3:2 - DETERMINE THAT PROPOSED EQUIPMENT CAN BE INSTALLED IN SPACE AVAILABLE. INSTALL j ® VOICE DATA OUTLET M.H. + 12" A.F.F. OR AS INDICATED Q EQUIPMENT SO PARTS ARE READILY ACCESSIBLE FOR INSPECTION AND MAINTENANCE EXTRA COMPENSATION WILL NOT BE ALLOWED FOR DISMANTLING EQUIPMENT TO OBTAIN ENTRANCE INTO BLDG. ,q_6 �D _ n��•I� TELEVISION OUTLET M.H.+12" A.F.F. Z J 3.3 -MATERIALS SHALL BEAR UNDERWRITER'S LABEL WHERE SUCH STANDARDS HAVE BEEN STABLISHED / A 10 A-1 I I� INTERCOM m O AND LISTED BY UNDERWRITERS LABORATORIES INC. I O 3.4 - MATERIALS, EQUIPMENT AND APPLIANCES SHALL CONFORM TO LATEST STANDARDS OF A-10 " A_� QT THERMOSTAT M.H. +50 A.F.F. (REFER TO A/C DWGS. FOR .LOCATION) O LLI AMCA, SMACNA, ANSI, ASHRAE, ASME, ASTM, NEMA, ARI AND NFPA. S.D 3.5 - USE EXTREME CARE IN SELECTION AND INSTALATION OF EQUIPMENT TO INSURE THAT NOISE AND I 4 MOTOR OUTLET _ Q O VIBRATION ARE HELD TO ABSOLUTE MINIMUM. CORRECT OBJECTIONABLE NOISE < 0 AND VIBRATION, PROVIDE ELIMINATORS REQUIRED FOR PROPER RESULTS. DINING/FAMILY ROOM ELECTRICAL PANEL O, 4.0 - PERMITS FEES AND CODES SWITCH BOARD Lu J I-- 4.1 - COST FOR FEES, PERMITS, TESTS NAD INSPECTIONS SHALL BE PAID FOR BY THE CONTRACTOR. FUSED DISCONNECTED SWITCH W/ DUAL ELEMENT FUSES LU Z 4.2 - INSTALLATION SHALL BE IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS INCLUDING: 1 S.F.B.C., N.E.C., N.F.P.A:, O.S.H.A. AND STATE, COUNTY AND CITY DEPARTMENTS OF HEALTH. �°_1 p O 5.0 - COOPERATE WITH OTHER TRADES \ A-& uJ I.0 FI O C.B CIRCUIT BREAKER (HACR TYPE IF FOR A/C UNIT) d U 5.1 - MAKE KNOWN ARRANGEMENT OF WORK AND CHECK ARRANGEMENT AND LOCATION OF OTHER TRADES A_g SAFETY GLASS O TO AVOID CONFLICTS. EXAMINE DRAWINGS OF OTHER TRADES TO DETERMINE EXACT EQUIPMENT LOCATION. ATTtC ACCESS INCANDESCENT FIXTURE OUTLET CIELING MOUNTED {) 6.0 = OPERATING INSTRUCTIONS P� I F0 INCANDESCENT FIXTURE OUTLET WALL MOUNTED 6.1 CONTRACTOR SHALL PROVIDE TO OWNER OPERATION AND MAINTENANCE MANUALS. �` V RECESSED HI-HAT LIGHT CEILING MOUNTED CONTRACTOR SHALL INSTRUCT OWNER OR OWNER'S REPRESENTATIVE IN OPERATION OF ALL EQUIPMENT. I TYPE WRITTEN LABELS SHALL BE PLACED IN PANEL BOXES DESIGNATING CIRCUITS LAYOUTS. ,A_& A-212 ��-CEILING FLUORESCENT STRIP 7.0 - INSPECTION A_25a-1 A-1 7.1 - NOTIFY OWNER TWENTY-FOUR HOURS IN ADVANCE WHEN PIPING OR EQUIPMENT IS TO BE TASTED, I FLOODLIGHT PANEL A BEFORE PIPING IS INSULATED OR CONCEALED, AND BEFORE TRENCHES ARE BACKFILLED. _16,18 7.2 - FAILING TO COMPLY WITH THE ABOVE, CONTRACTOR SHALL UNCOVER AND RETEST LINES, A-1 i I EMERGENCY LIGHT WITH BATTERY BACK UP REPAIRIG DAMAGE TO OTHER CONTRACTOR'S WORK, AS WELL AS HIS OWN. \ A/C C . -1 A/C COMP. EXIT LIGHT WALL MOUNTED 7.3 -BEFORE REQUESTING FINAL PAYMENT, INSPECT INSTALLATION TO ASSURE THAT WORK IS COMPLETE _ I UNIT AND REQUIREMENTS OF CONTRACT HAVE BEEN FULFILLED. O 0 CsF ® EXIT LIGHT CIELING MOUNTED ITEM PANEL A PANEL B PANEL C SERVICE 8.0 - CUTTING AND PATCHING A-12 1j I 8.1 - UNLESS OTHERWISE INDICATED, DO NO MORE CUTTING AND PATCHING THAN REQUIRED C-cE.I. °T'1° '"5 A-� SINGLE POLE TOGGLE SWITCH M.H. 50" A.F.F 5tE $3 FOR INSTALLATION OF WORK, A�2m A_6 THREE WAY SWITCH M.H. 50" A.F.F FOR FT. 1494 8.2 - CUTTING OF STRUCTURAL MEMBERS OR EXPOSED SURFACE OF CONCRETE BLOCK WILL NOT BE PERMITED. D 3 SINGLE POLE SWITCH W/ DIMMER M.H. 50" A.F.F 9.0 - MATERIALS AND EQUIPMENT KITCHEN 5EDROOM A-22 GENERAL LIGHTING 4482* 9.1 - CONDUCTORS SHALL BE THWN COPPER AS NOTED ON DRAWINGS. AA>- s.D ELECTRICAL SMOKE DETECTOR DEVICE SMALL APPLIANCES 4500 9.2 - RECEPTACLES, SWITCHES AND TELEPHONE OUTLETS SHALL BE AS MANUFACTURED BY LEVITON, 0 ® 4�x5� HUBBEL OR APPROVED EQUAL. COLOR AND STYLE AS SPECIFIED BY ARCHITECT AND/OR OWNER. o \ A-1 CONC. SLA5 F.D ELECTRICAL FIRE DETECTOR DEVICE WASHER 1500 9.3 - COMPUTER OUTLETS: (IF APPLICABLE) SHALL BE AS SPECIFIED BY OWNER. EXHAUST FAN REFRIGERATOR 1500 9.4 - PANELBOARDS: ) DISHWASHER 1500 A. GENERAL: INTERRUPTING CAPACITY RATINGS SHALL BE VERIFIED AND BASED ON THE AVAILABLE Camel. A_11 REF �e� CEILING FAN WATER HEATER 1500 SYMMETRICAL FAULT CURRENT GIVEN BY THE POWER COMPANY UPON LOCATION AND F.I. °1'� PANTRY A-10 INSTALLATION OF TRANSFORMER. G.F.I. GROUND FAULT INTERRUPTER B- DIRECTORY : COMPLETE AT END OF JOB TYPEWRITTEN. A_S LO C- FINISH: ANSI #61 ENAMEL OVER A RUST INHIBITING TREATMENT AFTER FABRICATION AND BEFORE *A-3 A-5 A-5 W.P. WATER PROOF. SUB-TOTAL V.A. 17482 co ASSEMBLY. AFTER INSTALLATION , AND BEFORE ACCEPTANCE BY OWNER, ASSEMBLY SHALL BE PAINTED 1 V.P. VAPOR PROOF. WITH A RUST INHIBITING PAINT ( COLOR SELECTED BY ARCHITECT ) D- NAMEPLATES: PROVIDE A LAMACOID NAMEPLATE WITH 5/16" LETTERS ENGRAVED ON FRONT FACE A_3 _10 ® 240 V. OUTLET 1st. 1OKW 10000 SHOWING PANEL NAME, VOLTAGE AND PANEL RATING. COORDINATE TO GIVE SAME NAME AS SHOWN &D © METER REST 40% 2993 ON PANELBOARD SCHEDULE. ,4_1 �4FETY GLA85 sP SPEAKER 9.5 - FIXTURES: A-3 ` 0 I AIR HANDLER UNIT #1 10830 1 A. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING FIXTURES AS SPECIFIED ON DRAWING WITH OWNER AND /OR ARCHITECT APPROVAL. VERIFY BEFORE PURCHASE AND INSTALLATION. UL 9.6- LAMPS: ALL LAMPS USED ON THIS PROJECT SHALL BE NEW, DELIVERED TO THE JOB SITE IN THE ORIGINAL A-S A`1 I RANGE 15500 PACKING CASES AND SLEEVES AND SHALL BE OF THE SAME MANUFACTURER UNLESS OTHERWISE SPECIFIED. DRYER 5400 9.7 - BALLAST: ALL BALLAST SHALL BE RATED TO OPERATE AT THE SERVICE VOLTAGE AS SHOWN AND AS !; w-.I. I SPECIFIED, PLUS OR MINUS THE DEVIATIONS WITH THE ELECTRIC SERVICE COMPANY ' `�' i A-9 -4 IS ALLOWED BY FRANCHISE. 'A-¢ TOTAL V.A. DEMAND 44723 ui 10.0 - FUSES 'A®� S® - A - SUPPLY AND INSTALL ALL FUSES IN EACH FUSED DEVICE. I A-10 AMPS DEMAND (V.A./240 V) 186 B - ALL AIR CONDITIONING AND KITCHEN EQUIPMENT SHALL BE FUSED AS PER MANUFACTURER'S Lu RECOMENDATIONS AND SPECIFICATIONS. A-4 �O®M C - INSTALL LABELS IN ALL FUSED DEVICES INDICATING PROPER SIZE FUSE TO USE. A-3 LIVIN DOOM I BREAKER 200 ui 11.0 - MISCELLANEOUS ,A_3 11.1 - ALL EMPTY CONDUIT TO BE SUPPLIED WITH NYLON PULL WIRE, A-1 11.2 - ALL FLEX CONDUIT SHALL HAVE "TITE-BITE" CONNECTORS. 11.3 - ELECTRICAL CONTRACTOR TO INSTALL AND WIRE OUTLETS IN FIXTURES WHERE SHOWN ON DRAWINGS UL -OUTLETS TO BE INSTALLED IN FIXTURES AFTER FIXTURES INSTALLATION. A- 4 A-4 11.4 - ALL DEDICATED CIRCUITS SHALL BE LABELED AS SUCH AT OUTLET. ® C� A-4 I 11.5 - THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AND VERIFYING THE TELEPHONE COMPANY REQUIREMENTS FOR INSTALLATION OF SERVICE AND ADVISE THE OWNER AND/OR THE ENGINEER OF ANY ADDITIONAL REQUIREMENTS THAT MAY BE NECESSARY. -2 LL 11.6 - THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AND VERIFYING THE ELECTRICAL A-1 ® L CT I CAL FLAN COMPANY'S REQUIREMENTS AND SERVICE ENTRANCE FOR THE BUILDING TO MAIN ELECTRICAL ROOM. 11.7 - ALL OUTLETS PLATES SWITCHES ETC. TO BE WHITE. I/4" _ V-®I vmN pm L ui TYPE: SQUARE "D" QD (OR EQUAL) PANEL A (TYPICAL) MAIN: 200 A 7 VOLTAGE: 120/240 V. 10 3W. FEEDER: 3#3/0 THW-CU (ALL 20 AMPS, 1 POLE CKTS. EXCEPT AS NOTED) MOUNTING: FLUSH CONDUIT: 2" U) J O O ri J L J < Q Z 0_ Z Z x z Q J El a_ y 0 0 0 3: REMARKS Y REMARKS © 0 U U Li 15 1 * 1/2" 12 GENERAL LIGHTING 1 2 GENERAL LIGHTING 12 1/2" * 1 15 20 1 * 1/2" 12 RECEPTACLE 3 4 RECEPTACLE 12 1/2" * 1 20 2 I GROUNDING ELECTRODE CONDUCTOR 20 1 * 1/2" 12 RECEPTACLE 5 6 RECEPTACLE 12 1/2" * 1 20 200 I] BOLTED-TYPE CONNECTIONDEVICE OR EXOTHERMIC WELD 20 1 * 1/2" 12 RECEPTACLE 7 8 EXTERIOR RECEPTACLE 12 1/2' * 1 20 ELECT. METER GROUNDING ELECTRODE CONDUCTOR 20 1 * 1/2" 12 G.F.I. BATH RECEPT. 9 10 SMOKE DETECTOR 12 1/2" * 1 20 20 1 1500 1/2" 12 KITCH. RECEPT. SMALL APL. 11 12 KITCH. RECEPT. SMALL APL. 12 1/2" 1500 1 20 $ NONMETALLIC PROTECTIVE SLEEVE 20 1 1500 1/2" 12 KITCH. RECEPT. SMALL APL. 13 14 REFRIGERATOR 12 1/2" 1500 1 20 50 2 15500 3/4" 3#6 RANGE/OVEN 15 16 DRYER 2#8 & 3/4" 5400 2 30 V I I=III=III=III=III=� III III=I 17 -1 1-18 1#10 20 1 1500 1/2" 12 WASHER 19 20 DISHWASHER 12 1/2" 1500 1 20 CONCRETE FOUNDATION No.4 AVG. OR LARGER BARE 50 2 5060 (**) 3/4" 2#8 A/C #1 21 22 A.H.U. #1 2#6 3/4" 10830 (**) 2 60 a' COPPER CONDUCTOR OR STEEL PANEL "A" a 20 FT. MIN:a REINFORCING BAR OR ROD NOT 3#3/0 THW-CU 2"0 200 A z a a d LESS THAN 1/2 INCH DIAMETER. 23 24 30 2 4000 1/2" 10 WATER HEATER 25 26 SPARE 1500 1 DIRECT CONTACT WITH EARTH 27 28 #2 IN 1„ COND. TO STRUCTURAL STEEL IN FOOTING I=III=�=- -I I-III- - I- =III=III=III=III=III=III=III=III= 1 1500 SPARE 29 30 O I=III=I I =I I =I I I=I =I I=I I I- CONNECT TO A CONCRETE-ENCASED ELECTRODE CONSISTING OF AT 31 32 - I _ LEAST 20 FT. OF ONE OR MORE BARE OR ZINC GALVANIZED STEEL 33 34 W - REINFORCING BARS OF NOT LESS THAN 1/2 INCH OR CONSISTING 35 36 ELECT. SERVICE =III=III=III= I =III= =III=I OF AT LEAST 20 FT. OF BARE COPPER CONDUCTOR NOT SMALLER =III=III=III=III=1 =III=1 I=III= THAN No: 4 AND LOCATED WITHIN AND NEAR THE BOTTOM OF A 37 38 CONCRETE FOUNDATION OR FOOTING THAT IS IN DIRECT CONTACT 39 40 SHEET: Q< CONNECT TO A CONCRETE ENCASED ELECTRODE -iii iii-Iii-I IF WITH EARTH. BOND TO A 5/8"x10' GND. RODS (SEE DETAIL) 41 42 OF: I- 6'-O" CONNECTED LOAD:SEE LOAD CALCULATION FEEDER:SEE RISER Lu = _ (A/C RATING 22,000 AMPS) FED FROM:SERVICE 0 I f I f /� ENCASE GROUNDING ELECTRODE DETAIL L I T IF SCALE: 3/4"=1 -0' 1/4 = V-0 (**) AC COMPRESSOR @ AIR HANDLER UNIT LOADS ARE NOT CONCURRENT. 0 W J LL