Loading...
06-1523-001a. 0 c� c\i 0 0 0 0 �v 0 a� i a� t4 tin E co E 0 W 0 0 i U Q) 0 a a x a� b U Q) .j U co a� b 0 0 b Q) S. i rA 0 U GENERAL CONSTRUCTION NOTES GRID (TYP.) MASON CONCRETE PROVIDED BLOCK UNITS SHALL CONFORM TO FLORIDA CONCRETE AND PRODUCTS EQUAL SHALL BE A MIX DESIGNED IN ACCORDANCE WITH A.C.I. 301 (LATEST EDITION) ASSOCIATION SPECIFICATION "CM -1" AND TO A.S.T.M. C90, GRADE N TYPE II. —61 TO ACHIEVE A 28 —DAY COMPRESSIVE STRENGTH AS FOLLOWS: MAXIMUM LINEAR SHRINKAGE FOR BLOCK UNITS USED FOR EXTERIOR WALL —92 —76 SHALL NOT EXCEED .032 � . MORTAR SHALL CONFORM TO —128 FOOTINGS &GRADE BEAMS ........................... ..........................4,000 P.S.I. A.S.T.M. C270, TYPE 'S' (1,800 P.S.I.) CLASS B COLUMNS........................... ............................... ..........................6,000 P.S.I. Ld CLASS »A» FIRST FLOOR SLAB ON GRADE ........................ ..........................3,000 P.S.I. STANDARD NO. 9 TRUSS DESIGN "DUR —O —WAL" OR ENGINEER — APPROVED EQUAL W ELEVATOR PIT & SHEAR WALL PEDISTAL ........ ..........................6,000 P.S.I. Q SHALL BE PROVIDED EVERY 2ND BLOCK COURSE (1' -4 VERTICALLY) FOR EXTERIOR 4 ELEVATED PRECAST DOUBLE TEES, SLABS & BEAMS ..............6,000 P.S.I. UNREINFORCED MASONRY WALLS AND LADDER TYPE FOR REINFORCED MASONRY 22 ALLOTHER ......................... ............................... ..........................4,000 P.S.I. » Q 14 GAUGE DOVETAIL ANCHORS (5i LONG) AND INSERTS SHALL BE USED 10 MAXIMUM WATER /CEMENT RATIO SHALL BE AS FOLLOWS: EVERY 2ND BLOCK COURSE AT BLOCK TO PRECAST MEMBER INTERSECTIONS. C.J. FOR 4,000 P.S.I. CONCRETE .......................0.55 NON —LOAD— BEARING MASONRY WALLS SHALL BE HELD CLEAR OF OVERHEAD 22 FOR 6,000 P.S.I. CONCRETE ....................... 0.5 SLABS AND BEAMS UNTIL DEFLECTION DUE TO APPLIED LOADS AND SHORE 16 SLUMP TO BE 4" f 1" REMOVAL ABOVE HAS OCCURRED. AFTER UPPER WALL HAS BEEN PLACED ON 19 ALL CONCRETE SHALL CONTAIN AN ENGINEER — APPROVED A.S.T.M. SLAB OR BEAM ABOVE, LOWER NON —LOAD BEARING MASONRY WALL SHALL BE 36 C494 TYPE 'D' ADMIXTURE (WATER— REDUCING RETARDER). GROUTED TIGHT BELOW MEMBER. CU CONCRETE IN ELEVATOR PIT WALLS AND RETAINING WALLS TO HAVE LIQUID APPLIED MEMBRANE AND PROTECTION BOARD IN ACCORDANCE W /PROJECT GROUTING OF BLOCK CELLS SHALL BE A CONTINUOUS OPERATION IN LIFTS 12 22 NOT EXCEEDING 4 FEET WITH MAXIMUM POUR HEIGHT OF 12 FEET. 19 SPECIFICATIONS. 20 26 TRANSPORTATION, PLACING, AND CURING OF CONCRETE SHALL COMPLY WITH GROUT SHALL CONFORM TO A.S.T.M. C -476 SPECIFICATIONS W/ F'c =3,000 P.S.I. 17 A.C.I. 318 BUILDING CODE (LATEST EDITION). AND SLUMP 9" t 1" MIX TO ENGINEER'S OFFICE FOR REVIEW. TESTING SHALL "SAMPLING 23 15 BE DONE FOLLOWING A.S.T.M. C1019 AND TESTING GROUT." W ALL CONCRETE STRUCTURAL COMPONENTS SHALL HAVE CONCRETE STRENGTH TESTED IN ACCORDANCE WITH A.S.T.M. STANDARDS, SOUTH FLORIDA QGROUT BLOCK CELLS ADJACENT TO ALL MASONRY OPENINGS. 26 BUILDING CODE AND ACI 318 (LATEST EDITION). TEST CYLINDERS MUST BE TAKEN TESTING OF BLOCK TO BE DONE FOLLOWING A.S.T.M. C140 "SAMPLING AND TESTING 14 EVERY 50 CUBIC YARDS OF CONCRETE PRIOR TO PLACEMENT. TESTING LAB OF CONCRETE MASONRY UNITS ". BLOCK PRISM STRENGTH F'm TO BE 1,500 P.S.I. 7 SHALL PROVIDE COPIES OF CONCRETE TESTS RESULTS TO ENGINEERS OFFICE FOR REVIEW. TESTING LAB SHALL PROVIDE COPIES OF MASONRY TESTS RESULTS TO SEE DETAIL CONCRETE MIX DESIGN SHALL BE SUBMITTED TO ENGINEER'S OFFICE FOR ENGINEER'S OFFICE FOR REVIEW. 17 REVIEW. FOR HIGH LIFT GROUTING OF MASONRY CELLS, CLEAN —OUTS SHALL BE 27 PROVIDED WIND FORCES ASCE 7/02 V =146 MPH 0 1 = 1.0 "a" = 13.7' Q 2 FILLER UND CONCRETE SLABS ON FILL PROVIDE SPACERS AT THE TOP, INTERMEDIATE, BOTTOM AND BASE OF WALLS COLUMNS (TYP.) FILL SHALL BE PLACED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE TO KEEP VERTICAL REINFORCING CENTERED IN BLOCK CELLS. TYPICAL SLAB ON GRADE JOINT DETAIL GEOTTEECHINICAL ENGINEERING CONCRETE CAN BE PBLACED AS DESCRIBED BELOW. ALL MASONRY WORK SHALL CONFORM TO ACI 530 /ASCE 5 N.T.S. JULY 26, 2002. STANDARDS, LATEST EDITION. NOTE: POUR SLAB IN PANELS AS SHOWN IN ALTERNATING 'SEQUENCE. WELDIN FILL MATERIAL SHALL BE SUBMITTED FOR TESTING TO AND APPROVED BY THE 15' MAXIMUM SPACING ALL WELDING TO BE DONE BY CERTIFIED WELDERS. WELDING SHALL BE MADE THE CONCRETE FOR ELEVATOR WALLS BELOW GRADE SHALL BE INTEGRALLY WITH E70 ELECTRODES AND CONFORM TO THE CURRENT RECOMMENDATIONS DAMP — PROOFED WITH 'HYDRATITE LIQUID' OR ENGINEER — APPROVED EQUAL, OF THE A.I.S.C. AND THE AMERICAN WELDING SOCIETY. IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. COLUMNS, BEAMS, WALLS OR ANY OTHER STRUCTURAL MEMBER PENETRATING BARRIER CABLES JOINT SEALING _ SLABS ON FILL SHALL BE ISOLATED BY PRE - MOLDED JOINT FILLER (1/2" CABLE SHALL BE LOW RELAXATION UNBOUNDED 7 WIRE STRANDED (1 "0) COMPOUND _ THICK) COMPLYING WITH . A.S.T.M. D1752, TYPE 1. CONFORMING TO A.S.T.M. A416, GRADE 270. CABLES SHALL BE EPDXY COATED. HIN REINFORCING IN SLABS ON FILL SHALL BE AS NOTED IN PLANS, AND PRE - STRESSING WIRE OR STRAND SHALL BE CLEAN AND FREE FROM PLACED IN ACCORDANCE WITH "REINFORCING STEEL" AND "WELDED WIRE CORROSION. `,, ;fs_, ±` • N '` `''' ' FABRIC" SECTIONS OF THESE GENERAL NOTES. RECORDS SHALL BE KEPT OF ALL JACKING FORCES. PROVIDE 6 MIL VISQUEEN VAPOR BARRIER UNDER ALL SLABS (UNLESS EXPANSION JOINT OTHERWISE NOTED ON PLANS). SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED MATERIAL BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA TO THE ISOLATION 0 LATI 0 N J WELDED WIRE FABRIC ENGINEER OF RECORD FOR APPROVAL BEFORE CONSTRUCTION. 0 I NT SHALL CONFORM TO A.S.T.M. A185 (LATEST EDITION), AND BE SUPPORTED ON SHOP DRAWINGS SLAB BOLSTERS SPACED AT 3' -0 C /C. WIRE TO BE 6 "X6 ", W4 X W4. W.W.F. Q2 ALL REINF. STEEL, STRUCTURAL STEEL AND PRECAST CONCRETE SHOP REINFORCING STEEL DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW, SAW CUT PRIOR TO ERECTION. SUBMIT ONE PAPER SEPIA (TO BE RETURNED) AND ONE 1/4 D MIN. SHALL BE DEFORMED BARS, FREE FROM LOOSE RUST AND SCALE, AND BLUELINE PRINT. (CERTIFIED MILL TESTS ARE ALSO REQUIRED) A CONFORMING TO A.S.T.M. A615 GRADE 60. PRECAST CONCRETE AND STRUCTURAL STEEL SHOP DRAWINGS AND CALCULATIONS ALL ACCESSORIES SHALL HAVE UPTURNED LEGS, AND BE PLASTIC DIPPED SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. AFTER FABRICATION. ACCESSORIES FOR REINFORCING SHALL BE INSTALLED ��`'- �"�"� "r''��- " IN ACCORDANCE WITH A.C.I. 315 CURRENT EDITION. ,� ALL WORK 12 " (TYP.) ALL PLACEMENT OF REINFORCING BARS SHALL BE IN ACCORDANCE WITH THE MANUAL OF STANDARD PRACTICE OF THE CONCRETE REINFORCING STEEL INSTITUTE. DESIGN CONFORMS TO THE REQUIREMENTS OF THE FLORIDA BUILDING CODE "0 SMOOTH COA�1- THIS HALF OF DOWEL (CURRENT EDITION). DOWELS O 36"O. C. WITH LUBRICANT TO PREVENT SUPPORT BARS SHALL BE #5 OR GREATER, AND NOT SPACED MORE THAN BONDING W/ CONCRETE FOUNDATIONS 4' -0" O.C. SUPPORT BARS AND ENDS OF MAIN REINFORCING SHALL NOT EXTEND MORE THAN 1' -6" PAST OUTERMOST CHAIR OR SUPPORT BAR. SHALL BE SPREAD AND CONTINUOUS FOOTINGS. FOOTINGS SHALL BE PLACED CONSTRUCTION J 0 I NT (C.S.J.) A DIRECTLY UPON THE NATIVE LIMESTONE ROCK FORMATION FOR AN ALLOWABLE MINIMUM OF 3 SUPPORT BARS AND 3 INDIVIDUAL HIGH CHAIRS FOR EACH BEARING CAPACITY OF 6,000 POUNDS PER SQUARE FOOT ( PSF). IN ACCORD CE SAW CUT SUPPORT BAR SHALL BE PROVIDED FOR TOP REINFORCING. WITH THE WINGERTER LABORATORIES INC FOUNDATION REPORT DATED � 1/4 D MIN. CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS FOLLOWS: JULY 26, 2002. , " GEOTECHNICAL ENGINEER SHALL INSPECT THE SOIL CONDITIONS PRIOR TO FOOTINGS .............. ............................... 3 FOUNDATION ..k,, ,. , #•- =,F.;,,:,: -,,,: THE PLACEMENT OF ANY AND STATE THAT THERE IS COMPLIANCE INTERIOR SLABS .................................. WITH ABOVE GIVEN SOIL CRITERIA. EXTERIOR SLABS AND BALCONIES EXPOSED TO WEATHER ..................... 1 " DESIGN LIVE LOADS BEAMS ................... ............................... 1 (TO STIRRUPS) . .. //. //. .. COLUMNS ............... ............................... 11* (TO TIES) ROOF STAIR /ELEVATOR TOWER .............................. 30 P.S.F. FLOOR ......................................... .............................50 P.S.F. CONTROL J 0 I NT (C.J.) RETAINING WALLS .. ............................... 2" MINIMUM (SEE PLANS) 1 , V� C) CL °� cn 1 FOOTING TYPICAL FOOTING 3/4" = 1' -0" )nents and Claddin EQUAL EQUAL 50 <A <100 100 <A —61 —56 C.J. —92 —76 —66 —128 —92 —66 CLASS B Lc Ld CLASS »A» CLASS »B» Lc W CLASS "A" CLASS "B" 4 15 11 22 1 29 15 10 19 25 C.J. 9 17 22 15 9 16 21 5 19 (4 N 36 W U CU U 19 12 22 C.J. 19 12 20 26 6 23 17 33 43 23 15 29 W 23 1 14 26 1 33 23 14 I.J. (TYP.) 31 7 27 20 SEE DETAIL 63 27 17 42 C.J. 27 16 38 PROVIDE" JOI 27 16 WIND FORCES ASCE 7/02 V =146 MPH 0 1 = 1.0 "a" = 13.7' Q 2 FILLER UND CONCRETE SLABS ON FILL PROVIDE SPACERS AT THE TOP, INTERMEDIATE, BOTTOM AND BASE OF WALLS COLUMNS (TYP.) FILL SHALL BE PLACED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE TO KEEP VERTICAL REINFORCING CENTERED IN BLOCK CELLS. TYPICAL SLAB ON GRADE JOINT DETAIL GEOTTEECHINICAL ENGINEERING CONCRETE CAN BE PBLACED AS DESCRIBED BELOW. ALL MASONRY WORK SHALL CONFORM TO ACI 530 /ASCE 5 N.T.S. JULY 26, 2002. STANDARDS, LATEST EDITION. NOTE: POUR SLAB IN PANELS AS SHOWN IN ALTERNATING 'SEQUENCE. WELDIN FILL MATERIAL SHALL BE SUBMITTED FOR TESTING TO AND APPROVED BY THE 15' MAXIMUM SPACING ALL WELDING TO BE DONE BY CERTIFIED WELDERS. WELDING SHALL BE MADE THE CONCRETE FOR ELEVATOR WALLS BELOW GRADE SHALL BE INTEGRALLY WITH E70 ELECTRODES AND CONFORM TO THE CURRENT RECOMMENDATIONS DAMP — PROOFED WITH 'HYDRATITE LIQUID' OR ENGINEER — APPROVED EQUAL, OF THE A.I.S.C. AND THE AMERICAN WELDING SOCIETY. IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. COLUMNS, BEAMS, WALLS OR ANY OTHER STRUCTURAL MEMBER PENETRATING BARRIER CABLES JOINT SEALING _ SLABS ON FILL SHALL BE ISOLATED BY PRE - MOLDED JOINT FILLER (1/2" CABLE SHALL BE LOW RELAXATION UNBOUNDED 7 WIRE STRANDED (1 "0) COMPOUND _ THICK) COMPLYING WITH . A.S.T.M. D1752, TYPE 1. CONFORMING TO A.S.T.M. A416, GRADE 270. CABLES SHALL BE EPDXY COATED. HIN REINFORCING IN SLABS ON FILL SHALL BE AS NOTED IN PLANS, AND PRE - STRESSING WIRE OR STRAND SHALL BE CLEAN AND FREE FROM PLACED IN ACCORDANCE WITH "REINFORCING STEEL" AND "WELDED WIRE CORROSION. `,, ;fs_, ±` • N '` `''' ' FABRIC" SECTIONS OF THESE GENERAL NOTES. RECORDS SHALL BE KEPT OF ALL JACKING FORCES. PROVIDE 6 MIL VISQUEEN VAPOR BARRIER UNDER ALL SLABS (UNLESS EXPANSION JOINT OTHERWISE NOTED ON PLANS). SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED MATERIAL BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA TO THE ISOLATION 0 LATI 0 N J WELDED WIRE FABRIC ENGINEER OF RECORD FOR APPROVAL BEFORE CONSTRUCTION. 0 I NT SHALL CONFORM TO A.S.T.M. A185 (LATEST EDITION), AND BE SUPPORTED ON SHOP DRAWINGS SLAB BOLSTERS SPACED AT 3' -0 C /C. WIRE TO BE 6 "X6 ", W4 X W4. W.W.F. Q2 ALL REINF. STEEL, STRUCTURAL STEEL AND PRECAST CONCRETE SHOP REINFORCING STEEL DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW, SAW CUT PRIOR TO ERECTION. SUBMIT ONE PAPER SEPIA (TO BE RETURNED) AND ONE 1/4 D MIN. SHALL BE DEFORMED BARS, FREE FROM LOOSE RUST AND SCALE, AND BLUELINE PRINT. (CERTIFIED MILL TESTS ARE ALSO REQUIRED) A CONFORMING TO A.S.T.M. A615 GRADE 60. PRECAST CONCRETE AND STRUCTURAL STEEL SHOP DRAWINGS AND CALCULATIONS ALL ACCESSORIES SHALL HAVE UPTURNED LEGS, AND BE PLASTIC DIPPED SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. AFTER FABRICATION. ACCESSORIES FOR REINFORCING SHALL BE INSTALLED ��`'- �"�"� "r''��- " IN ACCORDANCE WITH A.C.I. 315 CURRENT EDITION. ,� ALL WORK 12 " (TYP.) ALL PLACEMENT OF REINFORCING BARS SHALL BE IN ACCORDANCE WITH THE MANUAL OF STANDARD PRACTICE OF THE CONCRETE REINFORCING STEEL INSTITUTE. DESIGN CONFORMS TO THE REQUIREMENTS OF THE FLORIDA BUILDING CODE "0 SMOOTH COA�1- THIS HALF OF DOWEL (CURRENT EDITION). DOWELS O 36"O. C. WITH LUBRICANT TO PREVENT SUPPORT BARS SHALL BE #5 OR GREATER, AND NOT SPACED MORE THAN BONDING W/ CONCRETE FOUNDATIONS 4' -0" O.C. SUPPORT BARS AND ENDS OF MAIN REINFORCING SHALL NOT EXTEND MORE THAN 1' -6" PAST OUTERMOST CHAIR OR SUPPORT BAR. SHALL BE SPREAD AND CONTINUOUS FOOTINGS. FOOTINGS SHALL BE PLACED CONSTRUCTION J 0 I NT (C.S.J.) A DIRECTLY UPON THE NATIVE LIMESTONE ROCK FORMATION FOR AN ALLOWABLE MINIMUM OF 3 SUPPORT BARS AND 3 INDIVIDUAL HIGH CHAIRS FOR EACH BEARING CAPACITY OF 6,000 POUNDS PER SQUARE FOOT ( PSF). IN ACCORD CE SAW CUT SUPPORT BAR SHALL BE PROVIDED FOR TOP REINFORCING. WITH THE WINGERTER LABORATORIES INC FOUNDATION REPORT DATED � 1/4 D MIN. CONCRETE COVER FOR REINFORCING STEEL SHALL BE AS FOLLOWS: JULY 26, 2002. , " GEOTECHNICAL ENGINEER SHALL INSPECT THE SOIL CONDITIONS PRIOR TO FOOTINGS .............. ............................... 3 FOUNDATION ..k,, ,. , #•- =,F.;,,:,: -,,,: THE PLACEMENT OF ANY AND STATE THAT THERE IS COMPLIANCE INTERIOR SLABS .................................. WITH ABOVE GIVEN SOIL CRITERIA. EXTERIOR SLABS AND BALCONIES EXPOSED TO WEATHER ..................... 1 " DESIGN LIVE LOADS BEAMS ................... ............................... 1 (TO STIRRUPS) . .. //. //. .. COLUMNS ............... ............................... 11* (TO TIES) ROOF STAIR /ELEVATOR TOWER .............................. 30 P.S.F. FLOOR ......................................... .............................50 P.S.F. CONTROL J 0 I NT (C.J.) RETAINING WALLS .. ............................... 2" MINIMUM (SEE PLANS) 1 , V� C) CL °� cn 1 FOOTING TYPICAL FOOTING 3/4" = 1' -0" )nents and Claddin Tributary Area 20 <A <50 50 <A <100 100 <A —61 —56 —56 —92 —76 —66 —128 —92 —66 0 LEGEND: A = TRIBUTARY AREA (SQUARE FT ) + DENOTES PRESSURE ACTING TOWARD SURFACE. — DENOTES PRESSURE ACTING AWAY FROM SURFACE INSERT PER GENERAL NOTES DOVETAIL ANCHOR PER GENERAL AS NOTED ON NOTES PLANS *RM * ** >yi 12" OR 8" BLOCK - ' WALL PER GENERAL Q NOTES °° 0� PROVIDE" EXP. JOINT O IND OF MSA. WALL ROOF STAIR, COLUMN OR WALL N.T.S. SEE PLANS & SCHEDULES \--P OVIDE KWIK -CONII w/ 1" EMBEDMENT FOR DOVE -TAIL INSERTS O 16 O.C. STAGGERED BETWEEN ANCHORS & DUR -O -WAL TS -1 TYPICAL MASONRY A2 1601 THICKNED SLAB BLOCK T PRECAST - q FTG.w/ 2 #5 BOT. CONT. INTERIOR DETAIL 0 rrn n�rr�u n�u11� SAME SIZE AND-/ AS FTG. BOTT. REINF.Q 2 -2#5 BAR Tno nC mn nun » 2'-Om __4 0 FTG. BOTT. REINF. TYPICAL STEP FOOTING DETAIL STAIRS ........ ............................... ............................1 P.S.F. WALL ZONE DIAGRAM ELEVATION PRECAST CONCRETE WIND ANALYSIS ASCE 7- 02 ..... ............................146 46 M.P.H. (EXPOSURE C) 1 =1.05 NOTE: SAW CUT SLAB JOINT AS SOON AS CONCRETE COMPONENTS AND CLADDING DESIGN LOADS IS HARD ENOUGH TO WALK ON. 6 1 1/2* = 1' -0" S- PLAN @ ELEVATOR AND ROOF PRESSURE DIAGRAM FIRST PA GE 8 I RM I 5 I 48 I SIZE OF REINFORCED SIZE CENTER TO BLOCK WALL MASONRY OF BAR CENTER SPACING REINFORCED MASONRY LEGEND SPLICE LENGTH SCHEDULE (INCHES) fc' 3,000 P.S.I. 4,000 P.S.I. 5,000 P.S.I. 6,000 P.S.I. eus 9� Lc Ld CLASS A" CLASS B Lc Ld CLASS q CLASS B Lc Ld CLASS »A» CLASS »B» Lc Ld CLASS "A" CLASS "B" 4 15 11 22 1 29 15 10 19 25 15 9 17 22 15 9 16 21 5 19 14 28 36 19 12 24 31 19 12 22 28 19 12 20 26 6 23 17 33 43 23 15 29 37 23 1 14 26 1 33 23 14 24 31 7 27 20 48 63 27 17 42 54 27 16 38 49 27 16 34 44 8 30 22 55 72 30 19 48 62 30 18 43 56 30 18 39 51 9 34 25 62 81 34 22 54 70 34 21 48 62 34 21 44 57 10 38 28 69 89 38 24 60 77 38 23 53 69 38 23 49 63 11 42 31 76 98 42 27 66 85 1 42 1 25 59 1 76 42 1 25 1 54 70 1 0%Tr ,vv , L_ 1. FOR HORIZONTAL BARS, INCREASE THE SPLICE BY A FACTOR OF 1.3. IF MORE THAN 12" OF CONCRETE IS CAST BELOW THE BARS. 2. FOR TENSION BARS ENCLOSED BY TIES, WITH A SPACING BETWEEN THE BARS BEING SPLICED OF LESS THEN THE DIAMETER OF THE BAR, INCREASE THE SPLICE BY A FACTOR OF 1.5. 3. FOR TENSION BARS NOT ENCLOSED BY TIES, WITH A SPACING BETWEEN THE BARS BEING SPLICED OF LESS THAN 2 TIMES THE DIAMETER OF THE BAR, INCREASE THE SPLICE BY A FACTOR OF 1.5. Wind Pressure On Exterior Windows & Doors sf as NOTE; THE LOCATION OF ALL CONSTRUCTION JOINTS Negative Pressure HEIGHTS ZONES Tributa Area A <20 20 <A <50 50 <A <100 100 <A <200 200 <A <500 500<A- 55' -0 "AVG. 4 —66 —63 —61 —56 —53 —51 5 —81 —76 —69 —66 —58 —51 2 Positive Pressure HEIGHTS ZONES Tributa Area A <20 20 <A <50 50<A <100 100 <A <200 200 <A <500 500 <A 55' -0 "AVG. 4 & 5 61 58 56 51 48 45 N.T.S. ALL PRECAST MEMBERS TO BE DESIGNED BY PROFESSIONAL ENGINEER REGISTERED SEE TABLE FOR BUILDING EXTERIOR WALL PRESSURES. OAO RE OOl WIND FORCES AS PER ASCE 7/02 IN THE STATE OF FLORIDA FOR LOADS PER SOUTH FLORIDA BUILDING AND /OR SEE TABLE FOR ROOF UPLIFT PRESSURE BASED ON MEAN ROOF HEIGHT OF SLAB ON GRADE JOINT DETAILS IMPACT FEE PAID V = 146 MPH I = 1.0 3 AS SHOWN ON DRAWINGS. 62 FT. EXPOSURE "C" NO INTERNAL PRESSURE SUBMIT WALL BASE GROUT AND VERTICAL WALL DOWEL SPECIFICATIONS TO THE A �J ENGINEER'S OFFICE FOR APPROVAL. SUPERIMPOSED FLOOR DEAD LOAD .............................2 P.S.F. L �� ?.3 "a" = 13.7' A Q N.T.S. T & BOTT. REINF. CONT. ACROSS 10 IAMI -DAD UNTY BRACING THRESHOLD BUILDING NOTE APPROVED THE FRAME SHALL BE BUILT TRUE AND PLUMB AND TEMPORARY BRACING TO THE BEST OF MY KNOWLEDGE, THESE PLANS (S1 THRU S11) AND SPECIFICATIONS _ ,:..f�.,.;Y: a,, ' {'h° " BE INTRODUCED WHEREVER NECESSARY TO TAKE CARE OF ALL LOADS F ':.:.';;fi•;s4�rxn7 ,'£"' Air- SHALL t? �.Vi'",c;s,.r ..:._rr ,•,.. <r.,a' , r . COMPLY WITH THE APPLICABLE MI � :- ri.• -ar. ' TO WHICH THE STRUCTURE MAY BE SUBJECTED INCLUDING EQUIPMENT AND E L BLE NIMUM CODE (FLORIDA BUILDING CODE 2004) OPERATION OF SAME. SUCH BRACING SHALL BE THE RESPONSIBILITY OF x - - ,. r, THE GENERAL CONTRACTOR AND SHALL B LEFT IN PLACE A N A E L CE SLOG S - S f CAULKING 3 4 CONT. JOINT TO TI E BEAM M ABOVE REQUIRED F OR SAFETY. HORI ZO NT AL REIN F ORCING ' VERT. REINF. IF R PLAN) :- rt° - •r.:,.. - - - o - . ,_Ati � `C- PRECAST STRUCTURES MUST HAVE ERECTION BRACING TO SUSTAIN WIND VELOCITY OF - "� - ` �= ``��ti� --'ri' - „x Y=.,`� :'�- �, °�'s'..��'°.�;':�:'ra�. .:la,t r�. <r „r'9.`j.'4• ^- 4''..- .:.,;,'���. S�~ 75 M.P.H. AND CONTRACTOR SHALL PROVIDE BRACING SHOP DRAWINGS SIGNED AND -9;,zn gin., ` . d ,, , ,:.k , ;.=' ", :: :aa •'et; > ; ;'s =. ,....x' . ,:.x• Y_ - SEALED BY PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. s= .',t ._�, __ 'f..,' .' , ,F <,; : -. > - i; ;> ,,. ; z ,.•.:.,, :°y . y ; :.P: ,. v -:, ,. STRUCTURAL STEEL ADD GASKET FOR WALLS CAULKING NOTE; THE LOCATION OF ALL CONSTRUCTION JOINTS 2 0 SH AR E WALL 2 10 wide) de EXPOSED TO WEATHER & SOIL SHEAR V Kips SHALL BE APPROVED BY THE ENGINEER. SUM. MOMENT �M ) Foot— Kips SHALL CONFORM TO A.S.T.M. A36. CONTROL JOINT IN WALL FOR SHRINKAGE 30' MAX. Q SUM. SHEAR C V ) Kips SUM. MOMENT (EM) Foot— Kips 2 STRUCTURAL TUBING SHALL CONFORM TO A.S.T.M. A500 GRADE B (Fy =46 k.s.i.) SEE ARCHITECTURAL DRAWINGS FOR EXPANSS JOI ION JOINT DETAILS CONSTRUCTION JOIN T OF ANCHOR BOLTS SHALL CONFORM TO A.S.T.M. A307. TYPICAL WALL A CONTROL JOINT STRUCTURAL SLAB OR B CONNECTION BOLTS SHA L CONFORM T L CO 0 0 A.S.T.M. A325N. 283 38' -4" 96 215 N.T.S. 3,591 38' -4" N.T.S. �■■�■ ■� p■■iiii SEMI iiir ii►� -4i ii■■i■ ■ii■■ii■i 1 1.1 1 ARCHITECTURE INTERIOR DESIGN 285 Sevilla Avem* Coral Gables, Fl 33134 305» 4444433 fax 305.444 -0181 belsouduiet EMAIL• bcku niano HERSHELL GILL (CONSULTING ENGINEERS. INC.( 4601 PONCE DE LEON BLVD. SUM 350 CORAL GABLES, FL 33146 PROJECT #0607 305 667 -3631 FAX 305 665 -9298 EMAIL haill®bellsouth.net EB- 0003310 y :•'10 '. :1� r... Proposed New Project LEGEND: A2= TRIBUTARY AREA (FT ) �+� DENOTES PRESSURE ACTING TOWARD SURFACE. — DENOTES PRESSURE ACTING AWAY FROM SURFACE. NIND INDUCED MOMENTS AND SHEARS ON PRECAST SHEA ALLIS FOR GARAGE ALL SHEAR AND MOMENTS ARE SERVICE LOADS 2 S H EARWA LL 1 8c 3 " 18 wide) 2 0 SH AR E WALL 2 10 wide) de FLOOR ELEV Ft SHEAR V Kips SHEAR SUM. V ) Kips SUM. MOMENT �M ) Foot— Kips F LOOR SHEAR V ) Kips SUM. SHEAR C V ) Kips SUM. MOMENT (EM) Foot— Kips 49' -0” 119 119 1,278 49' -0" 26 26 283 38' -4" 96 215 3,591 38' -4" 20 46 784 27' -8" 89 304 6,858 27' -8" 20 68 1,497 17' -0" 128 432 L2YI65 17' -0" 26 92 3,244 —2' -0" 0 432 15,065 —2' -0" 0 92 3,244 NOTES: 1. ALL SHEARS AND MOMENTS SHOWN ARE SERVICE LOADS. South Miami Retail &Parking Facility S.W. 73rd Street & 58th Avenue, South Miami, Florida date 05/26/06 revision 06/08/06 08/10/06 A 10/04/06 sheet title GENERAL NOTES project number drawn by D.M. Scale: 3/32" =11I sheet number