MECHANICAL OTES U
COVERED TERRACE
1.0 - GENERAL
MASTER BEDROOM 1.1 - PROVIDE ( FURNISH AND INSTALL) ALL NECESARY MATERIALS AND LABOR FOR A COMPLETELY �
OPERATIONAL AIR CONDITIONING , HEATING AND VENTILATION SYSTEM AS SHOWN ON THE DRAWINGS AND Q Q
�4 \ HEREIN SPECIFIED .INSTALL IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING CODE cn ui 0
ASHRAE , NFPA, AND LOCAL ORDINANCES. Z Z) O
1.2 - SCOPE OF WORK Q 00 J
00 ILL
PROVIDE THE FOLLOWING COMPLETE SYSTEMS - ® w
A. SUPPLY AND RETURN DUCT SYSTEM. {n Q
B. EXHAUST SYSTEM FOR BATHROOMS.(WHEN REQUIRED) w cl�
C. AIR CONDITIONING UNITS WITH REFRIGERANT PIPING AND CONTROLS. > CD
DINING/FAMIL'I' ROOM 1.3 - PAY FOR ALL FEES, INSPECTIONS AND CONNECTION CHARGES REQUIRED. w W ry 1.4 - VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS AND EQUIPMENT SIZES PRIOR TO DUCT W Z
FABRICATION OR INSTALLATION, COORDINATE REQUIREMENTS TO AVOID INTERFERENCE WITH OTHER TRADES.
I� Lw_ 1.5 - SUBMIT SHOP DRAWING FOR ARCHITECT/ ENGINEER APPROVAL BEFORE PROCEEDING WITH THE PURCHASE SAFETY GLASS 0 I"c" OR INSTALLATION OF EQUIPMENT AND MATERIALS.
22'x3ro' 1.6 - GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD
ATTIC ACCESS OF ONE YEAR FROM DATE OF ACCEPTANCE.
LAUNDRY
2.0 - MATERIALS
2.1 - DUCTWORK. ALL DUCT SIZE ARE CLEAR INSIDE DIMENSIONS.
A: GENERAL AREAS: FIVE POUNDS DENSITY 1.5" THICK GLASSFIBER (R-6) DESIGNED, CONSTRUCTED AND
INSTALLED IN ACCORDANCE WITH SMACNA'S LOW PRESURE DUCT MANUAL
A/C COMP. D
El A/C ALL DUCT JOINTS SHALL BE SEALED AND TAPED.
UNIT _
B: TOILETS ROOM, KITCHEN, CLOTH DRYER EXHAUST AND FRESH AIR INTAKE IF APPLICABLE:
O 0 GALVANIZED SHEETMETAL, CONSTRUCTED AND INSTALLED ACCORDING TO LATEST EDITION OF
Duj I O O SMACNA'S, LOW VELOCITY CONSTRUCTION STD.
2.1.1 - PROVIDE DOUBLE THICKNESS TURNING VANES AT ALL SQUARE ELBOWS.
WHERE THE ELBOWS ARE RECTANGULAR INSTALL SINGLE THICKNESS INSTEAD.
BEDROOM KITCHEN 2.1.2 - PROVIDE VOLUME EXTRACTOR BEHIND EACH SUPPLY OUTLET AND AT EACH DUCT BRANCH.
a2.2 - REFRIGERANT PIPING. SEAMLESS COPPER TYPE "L" AND HARD OR SOFT DRAWN ON ACR COPPER TUBING
4'x6' o WITH WROUGHT COPPER SOLDER JOINT FITTING, SOLDER SHALL BE 95/5 APPLIED WITH SUITABLE FLUX.
CONC. SLAB / ° 2.3 - INSULATE ALL REFRIGERANT SUCTION PIPING WITH 3/4" CLOSED CELL POLYETHYLENE PREMOLDED PIPE
INSULATION , WITH AN APPROVED PIPE AND SMOKE JACKET. PAINT ALL EXPOSED INSULATION
WITH TWO COATS OF WHITE LATEX PAINT.
P 2.4 - PROVIDE AIR CONDITIONING UNITS WITH MATCHING LOW VOLTAGE HEAT-COOL THERMOSTACTS
PANTRY WITH ON-OFF AUTO SUB-BASE SWITCH, FURNISHED BY THE EQUIPMET MANUFACTURER.
2.5 - ALL AIR CONDITIONING COMPRESSORS SHALL BE WARRANTED FOR A MINIMUM OF FIVE co
YEARS AFTER DATE OF ACCEPTANCE OF THE PROJECT. qi
2.6 - AIR DISTRIBUTION PRODUCTS:
2.6.1 - PROVIDE SUPPLY AND RETURN GRILLES AND DIFFUSERS AS INDICATED ON THE DRAWINGS.
2.6.2 - PROVIDE EXTRUDED ALL ALUMINIUM AIR DISTRIBUTION PRODUCTS.
2.6.3 - PROVIDE FINISHES AND TYPES OF MOUNT IN COORDINATION WITH THE CEILING TYPES 0 1
SAFETY GLA54 AS SHOWN ON ARCHITECTURAL DRAWINGS.
0 u 2.6.4 - PROVIDE OPPOSED BLADE, KEY OPERATED DAMPERS BEHIND ALL AIR SUPPLY OUTLETS. w LL
2.6.5 - PROVIDE (FURNISH AND INSTALL) POWER SUPPLY WIRING SOURCE TO POWER CONNECTION, INCLUDE
STARTERS, DISCONNECTS AND REQUIRED ELECTRICAL DEVICES, INTERLOCK WIRING, RACEWAY, CONDUITS, 1
PULL WIRES AND EXPOSED CONDUITS FOR TEMPERATURE CONTROL SYSTEM.
ALL WIRING SHALL RUN IN CONDUITS, NO EXCEPTION.
3.0 - INSTALLATION
3.1 - INSTALL ALL EQUIPMENT IN ACCORDANCE TO THE MANUFACTURER'S MANUAL AND RECOMMENDATIONS,
PAYING SPECIAL ATTENTION TO REQUIRED CLEARANCES FOR INSTALLATION, OPERATION AND SERVICE.
3.2 - BALANCE ALL SYSTEMS TO PROVIDE AIR QUANTITIES AND CAPACITIES, INDI-ATED ON DRAWINGS.
BEDROOM LIVING R®OM SUBMIT FINAL TEST AND BALANCE REPORT TO ARCHITECT/ ENGINEER FOR ACCEPTANCE.
w LL
LL
c�
i- -
m
A/C SCHEDULE (YORK SPLIT SYSTEM RESIDENTIAL)
OF WOOD JOISTS
COOLING CAP. CONDENSER AIR HANDLER
UNIT TONS SEER COND. UNIT AIR HANDLER HEATER CFM
(MBTUH) COMPRES'R FAN MTR DIMENSION WT. BR.CIRC. REF. LINES DIMENSIONS FAN MTR WT.
MODEL NUM. MODEL NUM. TOTAL/SENSIBLE FLA/LRA HP/LRA H-W-D LBS. AMPS. LIQ.-SUCT. H-W-D HP/LRA LBS.
CONDENSING UNIT
FLEXIBLE CONNECTION 1 2.5 10.5 HDB030S06 FRC036N06 2HKO6500506 1035 28.4-21.0 13..5/68.0 1/8/0.8 24x24x24 135 7.7-253/8-3/4 40x18x22 1/2/3.3 105
i
POWER & CONT. REFRIGERANT LINES
CONCRETE BASE CONNECTIONS (SUCTION INSULATED,
AHU LIQUID UNINSULATED)
w/6"x6"-10/10 WWF
C
FASTEN C.U. TO ANCHORED PROVIDE ISOMODE c
2x4 METAL SUPPORT 4" ISOLATION PADS CLEANOUT PLUG
FASTENED TO CONC. SLAB 6 MI LIQUID LINE c
w/(2)1/2"bx3"ANCHOR BOLTS EA. �\ w/0 INSULATION
a°
TRAP
6"0 SCH 40
SEAL ENTRANCE OF REF. d PVC PIPE GALVANIZED STEEL
LINES INTO PVC PIPE MOUNTING FRAME
w/IMPERMEABLE, RESILIENT MATERIAL
1- BOLT TO FLOOR 1" CONDENSATE DRAIN
O SUCTION LINE
N 0
w/1/2"ARMAFLEX INSULATION TO DRYWELL gg
W & VAPOR BARRIER I'
n
NOTE: NO PLASTIC OR PVC IN R/A PLENUM. SHEET:
1
Q NO PVC FORA C DRAIN LINE NON COMBUSTIBLE
OF:
2
cn
CONDENSING UNIT MOUNTING DETAIL AIR HANDLER DETAIL