5903 SW 66 ST GREEN TREE-004 Humbm Rr Notes
ALL PLUMBING SHALL BE DONE IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING
CODE AND ANY STATE OR LOCAL ORDINANCES.
THE PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS
- - _ - AT THE JOB SITE PRIOR TO ANY FABRICATION INSTALLATION OF MATERIALS AND
HB W/VB EQUIPMENI,
s
THE PLUMBING CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES.
THE PLUMBING CONTRACTOR SHALL PROVIDE TEMPORARY MATER SERVICE DURING
CONSTRUCTION,
THE PLUMBING CONTRACTOR SHALL INSTALL ALL PLUMBING FIXTURES FURNISHED BY
tt
THE OWNER AND AS REQUIRED BY THESE DRAWINGS.
¢ ALL PIPING SHALL BE INSTALLED RECESSED IN BLOCK WALLS, CHASES OR PARTITIONS,
O N GRADE RADE SPILL c EACH PLUMBING FIXTURE SHALL BE PROVIDED VATH AIR CHAMBERS AS PER THE SFBC.
O
TERMINATE SEE SHT. A-1 PROVIDE A SHUT—OFF VALVE FOR EACH FIXTURE,
" AFG PVC SCH. 40 TO WATER/SEWER
CONNECTIONS/SIZES WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING MALL BE
PROVIDED TO CONNECT BOTH TYPES OF PIPES.
1," CID —---------------------------------------
A PROVIDE PIPING AS FOLLOWS:
DOMESTIC COLD AND HOT WATER AND WATER HEATER RELIEF PIPING WITH COPPER
TUBE E "K" OR "L" WITH LEAD—FREE SOLDER JOINTS, MIN. 125 S WGO BRONZE
E M 4 VALVES,
NOTE: ALL SANITARY
—Y LINES—SLOPE: 1/8" f FT. C.G. SANITARY WASTE AND VENT; SCHEDULE 40 PVC.
Re 3/4-
`3/4"
AIR CONDITIONING CONDENSATE: COPPER DWV AND FITTINGS OR PVC PIPE SCHEDULE
BATH I KRTCH N TO WATE METER 40.
a ,
3"V, UP 3" BELOW SLAB 3" 3" SAN 1 FU AIR CONDITIONING DRAINAGE PIPING WITH 3/4" MIN. THICK CLOSE CEE POLYTHYNE PIPING
3 V.i P 3" TO CITY SEWER i INSULATION, SEE A/C PLANS FOR LOCATIONS.
arc
'LAUNDRY I DRAIN, TRAPS, CLEANO.ITS AND SPECIALTIES:
2" 13-C A. INTERIOR FLOOR CLEANOUTS, JOSAM 56020 OR EQUAL, NIKALOY COVER.
wash " ° B. EXTERN CLEANOUTS, JOSAM 56440-5 OR EQUAL
TUB k dry i 2 C. WALL CLEANOUT. PVC SCH. 40 ?T? BRANCH WITH COUNTERSUNK PLUG AND COVER
PATH CHROME PLATED TOP cond. unit ° ' r K° K° _ 3/4,, II II T mm PVC PLASTIC PIPE MAY BE USED FOR SANITARY WASTE AND VENT SYSTEM WHERE
PERMITTED BY CODE.
/A/C SLAB FOR WATER AND SEWER PIPE SIZING SEE RISER DIAGRAMS AND PLUMBING FLOOR PLAN.
0,FEE 3/4" T&P 2"V. UP
SPILL OUTSIDE HB W/VB E.
TERMINATE Humbmg RxWre,
PRU WATER
A WC WATERI CLOSET TANK 3" 1/2' R 'F� BY R OWNER
SCALE: 1/4" V-0" LAV LAVATORY 1"1/2" 1/2' 1/2'
TUB BATH TUB 2 1/2- 1/2-
WM WASHING MACHINE " 1/2- 1/2"
K SIC KITCHEN .SINK 1 1/2' 1/2" 1/2"
H ° , Legend
SAN SANITARY DRAIN
( V SANITARY VENT LINE
4- SAN (21 ,FU) CW COLD WATER
w (I 3", TO SEWER CO HW HOT WATER VTR
3" VTR GV GATE VALVE
( °° �•«� AC AIR CHAMBER
>3' WCO WALL CLEAN OUT
3„ �k' i CO CLEAN OUT TO GRADE
I S\o f a
Rey eater DD et fl
I3.. WHO 1-1/2"
LAV 3" 2"s 2 TO H.W. SYSTEM W. SERVICE
UNION (TYP)
1-1/2" 5t0P P ESS, TEMP.
3„
WC HEAT TRAP RLIEF VALVE;
3,>
3/4" T&P SPILL
TUB OVER
TERMINATE
SPILLOVER
PIPE 0 6°" AFG
ELECTRIC
WATER 1 3-1-9 __ _ -----v
-v
cc� �aal u 4
C aCO �� l9 40A ARL. r
4.6 KW u u
240-1-60 0
y _T1 DRAIN BIBB
FIN FL
1/2"
1/2" EXIST
�'�- DUAL HA]BRTAT FOR ��5T'[�'q;�pr�v�°
1/2„ WATER OF GREATER EA II, MCI
bP v
d � M METER 9350 DADELAND BOULEVARC
3f4" SUITE 200 3/4" 3/4"34' g 2 r
HB Wf °` - WATER MIAMI, FLORIDA 33256
305-670-2224
AGENT: ANNE MANNING, EXECUTIVE DIRECTOR
4 GKAL, 1!2" 1/2„ 3 1/2"
W, a
2401-60
n n 3/4" 1/2"
O 4 P O
n LAV T .
N :'ALL HO S- HAVE ANTI-SCALD VALVE. HB W/VB ROD �d�n� A���� �� �� aabkp
1 2," 1 1 n FReirbda 3 Il34
1/2" 1/2"
/ ' (305) 442°04RO Fax 442°6757 nca ircOAO LPCom
1f2
PVC
r ct Data.
Site Address: MIAMI, FLORIDA
3f4" '1/2" Work Description: New One Story Single Family Residence
Property Owners: HABITAT FOR HUMANITY OF GREATER MIAMI, INC. 670-2224
Architect of Record: Paul W. Buckler AR13708
,. . Project Date: 7-26-99
Revisions:
Water Rsometftoc
1
PL RNG FLOOD. PLAN F�- 1 of 1