Loading...
06-425-004GARJ PT DOOR J, 7008 ROLLER 'RACK SUPPORT ANGLE IIN. 8 GA GALV. STEEL PT. BACK JAMB 4' x 3 1/2' TAP CONS 12' O.C. TYP. ,fNFOR CONCRETE COLUMN SEE FOUNDATION PLAN FOR SIZING NOTE: CONTRACTOR TO PROVIDE DADE COUNTY PRODUCT APPROVAL -65 PSF GARAGE DOOR JAMB SECTION AND TACK DETAIL SCALE: 1 1/12' = 1' -0' ATTIC ACCESS NOTE: 22'x 3(o' MIN. WITH R -30 INSULATION ON CEILING AND SIDE WEATHER STRIPPED (AT G=ARAGE AREA PROVIDE METAL CLAD BACK -UP ONE HOUR FIRE RATED) J ATTIC AREA WOOD FRAME TRUSS — 2 EACH METAL HOOK " \/ TO SECURE PANEL CEILING AREA ATTIC ACCESS PANEL SCALE: 1 1/12" = I' -0' 5/6' PLYWOOD COVER W126 GA METAL 12 TRUSS - 5/8' TYPE X DRYWALL WOOD TRIM NOTES: l.) PROVIDE D.G. PRODUCT CONTROL APPROVAL FOR IMPACT RESISTANT EXTERIOR WINDOWS. 2.) ALL WINDOWS AT BEDROOMS SHALL BE 'EGRESS' TYPE, U.ON. REFER TO DOOR / WINDOW SCHEDULE THIS SHEET. THE EGRESS WINDOW SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS AND PROVIDING A CLEAR OPENING OF NOT LESS THAN 20' IN WIDTH, 24' IN HEIGHT, AND 5.1 50-FT. IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44' OFF THE FLOOR THE MODE OF OPERATION DOES NOT REQUIRE THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE, OR EFFORT TO MAKE AVAILABLE THE REQUIRED CLEAR OPENING, AND NO PART OF THE MECHANISM SHALL BE PLACED HIGHER THAN 54' ABOVE THE FINISHED FLOOR 3.) GENERAL CONTRACTOR TO VERIFY AND COORDINATE ACTUAL WINDOW DIMENSIONS AND MASONRY OPENINGS PRIOR TO CONSTRUCTION. 4.) ANY CHANGE OF INTERIOR FINISHES BY OWNER/G.C. SHALL BE COORDINATE W/ THE ARCHITECT. 5.) INTERIOR PARTITION OF 3 5/8' -5 5/8' METAL STUDS 6 24' O.C. REFER TO FLOOR PLAN FOR DIMILOCATIOK (o.) PROVIDE MR/G.W.B. ON WET WALLS ONLY. 1.) BATH DOORS SHALL BE OPERABLE FROM OUTSIDE IN EMERGENCY SITUATIONS. SJ CLOSET DOORS SHALL BE OPERABLE BY CHILDREN FROM INSIDE. 9.) SEPARATE PERMIT REQUIRED FOR ROOFING, WINDOWS AND DOORS. 10.) SEE ELEVATIONS ON SWEET A -415. 11.) FOR SECURITY ENTRY NOTES REFER TO BUGLARY NOTES SHEET A -I. 12•) GLASS OR MIRRORS IMMEDIATELY SURROUNDING A BATHTUB OR SHOWER ENCLOSURE GLASS OR MIRRORS IMMEDIATELY SURROUNDING A BATHTUB OR SHOWER ENCLOSURE SHALL BE SAFETY GLAZING WHERE THE GLASS OR MIRRORS ARE LESS THAN 60 INCHES (15 M) ABOVE THE FLOOR OF THE TUB OR THE SHOWER 13.) SHOWERS, SHOWER COMPARTMENTS SHALL HAVE FLOORS AND WALLS CONSTRUCTED OF SMOOTH, CORROSION RESISTANT AND NONABSORBENT WATER - RESISTANT MATERIALS TO A HEIGHT OF NOT LESS THAN 10 INCHES (1118 MM) ABOVE THE COMPARTMENT FLOOR AT THE DRAIN. 14.) PROVIDE CERAMIC TILE FINISH IN ALL BATH AND SHOWER WALLS UP TO 6' -0' HIGH TYPICAL sm e s �n M 1 A -7 11' -6' 2' -8' 31' -5' 2' -10' 4' -4' 2' -Im' 2' -6' I LVA T -2' 2' -8' I 9' -8' 13' -Im' 1' -II' I' -6' 1' -4' 2' -2' T -2' I' -4' I'4o' 2' -6' 1' -1' S' -9' 1' -2' a 0 0 a —TT ------ - ------ CV - - - - - ------ N I I I I I I I Z U O J LL W a O w a~ _- 0 4 I w W z I I I I I 0 t L a gn > W C6 N W _ Ln co O M w z La W z o in °a CL N I COV. TERRACE I �, a __y G I I 'Ile G I 11' -2' / \ e I 1I I .. a Oa • O • �2 I STAIR 1 4 KITC H N rI I r --- - - - - -- - - - - 7 2' 3' -6' 2' - �41 LIVING OOM 0 0 0 `" POWDER I RM. FAMILY ROOM 08 22' -I0' 3-0' Im' -1' 20' -0' - I0' -3' 1 ' STAIR DATA I _ I 1 21 RISERS e 1' I UP — 1 I i 10 TREADS 0 II' 1 N I 1 9 a @ 1� 1 O ' 1._ 6,= 6,- - - - - -- 6, 4, - - - -- 4, -1' 1' -m' 2' -9' 18'I � 12' -4' v �n 3 -01 6181 L- -------- - - - - -- a - - 6 a, - - --�-- - - - - - -- 16 — co I I I I I 'I I I I I I I I I I I I I I I I I I -------- sti. CAT2� 2 —� — —�— -- 9 -- SAFETY CABANA 9 GLASS 12 1 e I �- - - -- F_ - - -- —� PROVIDE CERAMIC I ( v TILE FINISH IN ALL 1g CL. I I 1 I I BATHROOM SHOWER WALL UP TO V -m' HIGH TYPICAL 4</7 I I I I I mm I W I LVA " I I I � e v 0 A-8 lliffillollF,&I A/C 9 12 PROVIDE 12m SQ IN. 1' VENTS W/ 1' OF C.L THE HIGHEST PART 1 OF THE FLOOR I 1 16 cA 5 PROVIDE CERAMIC A s FOYER I I I I TILE FINISH IN ALL STUDY /GUEST i IFE. ' -m' I I I I I BATH SHOWER WALLS O GARAGE 0 o I I e I I -101 DINING ROOM. I UP TO 6' -m' NIGH TYPICAL m' -1' 2 MAID'S RM. I' SLOPE 4 i - — — I — 12' -6' f @ lm' -m' — 5 -1 ' — — — — — 26-0' — — — — I I I UTILITY o GARAGE NOTES I 9 N 1.) PROVIDE SIGN THAT READS: "DANGER! DO NOT OPERATED WINDOWS 1 � I I ENGINE W/ DOOR CLOSED --� j� I I EGRESS ❑ CARBON MONOXIDE EMISSION WINDOW CAN BE LETHAL ". I CL. `" L — — — — — — — — — — J - USE 1/2' LETTERS MINIMUM. u, a PROVIDE 120 SO. IN. EN TRY VENTS W/ T OF THE HIGHEST PART 1' -3' ' -3' _� 8' �-mn OF THE FLOOR FA 2' -6' 5' ' 2' -6' I' -3' I' -2' 11.81 1' -10' 1' -3' J 20 5' -11' 5' -II' 2' -1' 2' -8' 5' -m' 5'•m' 6' -3' (0' -11' 4' -6' 8' -9' 2' -9' 5' -1' 9' -Im' 5' -9' IF II' -lm' 5' -4' Im'!0' 13' -2' 16' -0' 21' -2' 11' -6' 0 1 as ' FIRST FLOOR PLAN SCALE: 1/4" =1'-0" N n 20 a0 'v m 2 A -7 � e LiN ZZ W - -� m I I I � e v 0 A-8 A/C 9 12 PROVIDE 12m SQ IN. 1' VENTS W/ 1' OF C.L THE HIGHEST PART 1 OF THE FLOOR I 1 16 cA 5 PROVIDE CERAMIC A s FOYER I I I I TILE FINISH IN ALL STUDY /GUEST i IFE. ' -m' I I I I I BATH SHOWER WALLS O GARAGE 0 o I I e I I -101 DINING ROOM. I UP TO 6' -m' NIGH TYPICAL m' -1' 2 MAID'S RM. I' SLOPE 4 i - — — I — 12' -6' f @ lm' -m' — 5 -1 ' — — — — — 26-0' — — — — I I I UTILITY o GARAGE NOTES I 9 N 1.) PROVIDE SIGN THAT READS: "DANGER! DO NOT OPERATED WINDOWS 1 � I I ENGINE W/ DOOR CLOSED --� j� I I EGRESS ❑ CARBON MONOXIDE EMISSION WINDOW CAN BE LETHAL ". I CL. `" L — — — — — — — — — — J - USE 1/2' LETTERS MINIMUM. u, a PROVIDE 120 SO. IN. EN TRY VENTS W/ T OF THE HIGHEST PART 1' -3' ' -3' _� 8' �-mn OF THE FLOOR FA 2' -6' 5' ' 2' -6' I' -3' I' -2' 11.81 1' -10' 1' -3' J 20 5' -11' 5' -II' 2' -1' 2' -8' 5' -m' 5'•m' 6' -3' (0' -11' 4' -6' 8' -9' 2' -9' 5' -1' 9' -Im' 5' -9' IF II' -lm' 5' -4' Im'!0' 13' -2' 16' -0' 21' -2' 11' -6' 0 1 as ' FIRST FLOOR PLAN SCALE: 1/4" =1'-0" N n 20 a0 'v m 2 A -7 � e LiN ZZ CONSULTING: W M a v 0 a 0 0 a Z U O J LL W a O w a~ _- 0 Z W w W z c 0 t L a gn > W C6 N W U) N N co Ln co O M w z CONSULTING: J M m U W - o Q U F- c 0< 3 L0 00 00 �Z rte • • ` `' ;, ' a . L` � r , • W w Q _ ` FIRST'- • ` FLOOR t PLAN SCALE AS SHOWN DRAWN CV JOB 2006 DATE 01/31/06 SHEET: A -3 3 OF:9 M v a 0 U O J LL W W U O w a~ _- Z W w W U) c t W gn W C6 N W U) N N co Ln co O M in La W z o in °a CL a J M m U W - o Q U F- c 0< 3 L0 00 00 �Z rte • • ` `' ;, ' a . L` � r , • W w Q _ ` FIRST'- • ` FLOOR t PLAN SCALE AS SHOWN DRAWN CV JOB 2006 DATE 01/31/06 SHEET: A -3 3 OF:9