06-1945-001t
.I
GAR/
PT DOOR J
"BOOR ROLLS =R
RACK SUPPORT ANGLE
11N. 8 GA GALV. STEEL
PT. BACK JAMB
4' x 3 1/2' TAP CON5
12' O.C. TYP.
:EINFCR CONCRI =T COLUMN
SEE FOUNDATION PLAN
FOR SIZING
NOTE: CONTRACTOR TO PROVIDE
DADE COUNTY PRODUCT APPROVAL
-65 PSI=
GARAGE DOOR JAMB SECTION
AND TACK DETAIL
SCALE: 1 1/12' = V-0'
ATTIC ACCESS NOTE:
22'x 3(o" MIN. WITH
R -30 INSULATION ON CEILING
AND SIDE WEATHER STRIPPED
(AT GARAGE: AREA PROVIDE:
METAL CLAD BACK -UP ONE
HOUR FIRE RATED)
ATTIC AREA
WOOD FRAME
I it ,-'s
5/8' PLYWOOD COVER
W/26 GA METAL IP
TRUSS
5/8' TYPE X DRYWALL
2 EACH METAL HOOK \/ WOOD TRIM
TO SECURE PANEL CEILING AREA
ATTIC ACCESS PANEL
SCALE: 102" = 1' -0'
NOTES:
I.) PROVIpE D.C. PRODUCT CONTROL APPROVAL FOR IMPACT RESISTANT EXTERIOR WINDOWS.
2.) ALL WINDOW5 AT BEDROoM5 SHALL BE 'EGRESS' TYPE, U.ON. REFER TO DOOR /
WINDOW SCHEDULE THIS SHEET,
THE EGRESS WINDOW SHALL BE OPERABLE FROM THE IN51DE WITHOUT THE USE OF TOOLS AND
PROVIDING A CLEAR OPENING OF NOT LE53 THAN 20' IN WIDTH, 24' IN HEIGHT, AND 5.1 SOFT. IN
AREA. THE 501TOM OF THE OPENING SHALL NOT BE MORE THAN 44' OFF THE FLOOR
THE MOPE OF OPERATION DOES NOT REQUIRE THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE,
OR EFFORT TO MAKE AVAILABLE THE REQUIRED CLEAR OPENING, AND NO PART OF THE
MECHANISM SHALL BE PLACED HIGHER THAN 54' ABOVE THE FINISHED FLOOR
3.) GENERAL CONTRACTOR TO VERIFY AND COORDINATE ACTUAL WINDOW DIMENSIONS AND MASONRY
OPENINGS PRIOR TO CONSTRUCTION.
4.) ANY CHANGE OF INTERIOR FINISHES BY OWNER/G.C. SHALL BE COORDINATE W/
THE ARCHITECT,
5.) INTERIOR PARTITION OF 3 5/8' -5 5/8' METAL 5TUD5 .9 24'0C, REFER TO
FLOOR PLAN FOR DIMAOCATION.
ro.) PROVIDE M.R/G.W.B, ON WET WALL5 ONLY.
1.) BATH DOCR5 SHALL BE OPERABLE FROM OUTSIDE IN EMERGENCY
SITUATIONS.
S.) CLOSET DOOR5 SHALL BE OPERABLE BY CHILDREN FROM INSIDE.
9.) SEPARATE PERMIT REQUIRED FOR ROOFING, WINDOWS AND POOR5.
10.) SEE ELEVATIONS ON SHEET A -4/5.
I1.) FOR SECURITY ENTRY NOTE5 REFER TO BUGLARY NOTES SHEET A -1.
12.) GLA55 OR MIRRORS IMMEDIATELY SURROUNDING A BATHTUB OR SHOWER ENCLOSURE GLA55 OR
MIRRORS IMMEDIATELY SURROUNDING A BATHTUB OR SHOWER ENCLOSURE SHALL BE SAFETY
GLAZING WHERE THE GLA55 OR MIRROR5 ARE LE55 THAN (90 INCHE5 (1.5 M) ABOVE THE FLOOR OF
THE TUB OR THE SHOWER
13.) SHOWER5. SHOWER COMPARTMENTS SHALL HAVE FLOORS AND WALLS
CONSTRUCTED OF SMOOTH, CORRO6fON RESISTANT AND NONABSORBENT WATER - RESISTANT
MATERIALS TO A HEIGHT OF NOT LE55 THAN 10 INCHES (1118 MM) ABOVE THE
COMPARTMENT FLOOR AT THE DRAIN.
14.) PROVIDE CERAMIC TILE FINISH IN ALL BATH AND SHOWER WALL5 UP TO 6' -0' HIGH TYPICAL
c
,0 1
i
N \�
1=x10
w
O
s • • .
o:
s
0
a
Z
• a
�
a •
a
LL
fl
N
Z
Q
•
•
a
i
N \�
1=x10
(CONSULTING:
w
O
o:
0
a
Z
w
J
a
LL
fl
N
Z
Q
O
W
0
!Z
4
W
�z
CD
(CONSULTING:
• N -fit
Ps
N ' l ,11I,.
FIRST i
FLOOR
PLAN
SCALE AS SHOWN
DRAWN CV
JOB 2006
DATE 01131(08
SHEET:
A -3
3 OF: 9
_"
III
O
J
LL
Q
W
w
!Z
CD
W
(00
o
OT
W
Z
N
cn
N
co
O
cm
U
w
--11
a.
�
w
Z
O
N
V1
w
Q
a_
• N -fit
Ps
N ' l ,11I,.
FIRST i
FLOOR
PLAN
SCALE AS SHOWN
DRAWN CV
JOB 2006
DATE 01131(08
SHEET:
A -3
3 OF: 9
_"
III