6090 SW 63 ST EB-09-014-007 314"CU C.W.SERVICE MARK DESCRIPTION DRAIN A l N WATER MANUFACTURER 3/4"CU H.W. SYSTEM COLD-HOT WC WATER CL05ET TANK 3"' 1/2' --- BY OWNER PRE55.TEMP. RELIEF VALVE LAV LAVATORY 1-1/2" 1/2' 112' BY OWNER HEAT TRAP COPPER TYPE"L"A5TM B-75 REQUIRED IF 5H SHOWER 2" 112' 112' BY OWNER NOT PROVIDED BY TANK MANUFACTURER SHUT OFF VALVE TUB TUB 2" 1/2' 112' BY OWNER INTO COLD WATER WASHING MACHINE 3" 1/2' 112' BY OWNER 3/4"CUTUP 5PILLOVER G"air gap Plumbing Leuend WATERIC 1-114 REDUCE COUPL'G SAN SANITARY DRAIN HEATER 3/4"CU or CPVC in wall V SANITARY VENT LINE 40 GAL, 240-1-GO TERMINATE SPILL OVERFLOW CW COLD WATER EF= 0.92 PIPE @ G"AFG HW HOT WATER DRAIN 13IDD -- GV GATE VALVE FIN FL CO CLEAN OUT TO GRADE Plumbinu Uotes [pew 2004 Flovida Guilding Code Plumbing) 1,THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL AND EQUIPMENT[IF NECE55ARY1 FOR THE INSTALLATION OF A COMPLETE SEPTIC TANK SYSTEM IN ACCORDANCE WITH TH15 DRA1MNIG,THE APPLICABLE EDITION OF CHAPTER I OD-G, FLORIDA ADMIN15TRATIVE CODE, STANDARDS FOR ON SITE SEWAGE TREATMENT AND D15PO5AL SYSTEMS, REFER TO A-I FOR 51TE SPECIFIC INFORMATION REGARDING CITY SEWER OR SEPTIC SYSTEM, 3/4"H B 4v/VAC, BKR 2. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF EX15TING PIPES BEFORE COMMENCING TO WORK AND MAKE MODIFICATIONS AS REQUIRED WITHOUT ADDITIONAL C05T TO THE OWNER. 1 ALL PIPING SHALL BE INSTALLED RECE55ED IN BLOCK WALLS, CHA5E5 OR PARTITIONS. 2" r f' 4. PLUMBING CONTRACTOR 5HALL PAY ALL C05T OF PERMIT, INSPECTIONS AND OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK, UPON FINAL INSPECTION,A CERTIFICATE FROM THE C� m LOCAL STATE INSPECTION AUTHORITY SHALL.BE FURNI5HED TO THE OWNER, HA 2i°E � 5. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMEN51ON5 AT JOB SITE PRIOR TO co FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. �" e! t � G. COORDINATE ALL WORK WITH OTHER TRADE5. 1-I12 2004 FBC PLU 51NG CODE(G043): "A �' HA : MG 7. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT, NCO f WATER-HAMMER ARRESTOR SHALL BE INSTALLED WHERE MATERIALS AND LAYOUTS PRIOR TO INSTALLATION. QUICK-CL051NG VALVES ARE UTILIZED, UNLE55 OTHERWISE APPROVED. THE A 5TOR SHALL BE 8. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND MU5T BE FURNISHED 50 AS TO PREVENT ANY DELAY rf 4 LOCATED WITHIN AN EFFECTIVE RANGE OF THE IN THE PROGRESS OF WORK, PLUMBING CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN °., QUICK-CL051NG VALVE. ARRESTORS SHALL CONFORM MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. TO A55E I O." 2803.G.1.1 DISCHARGE , 0. PROVIDE SHOCK A1550RBER5 SIZE, QUANTITY AND LOCATION AS PER P.D.I. STANDARDS. THE RELIEF VALVE SHALL DISCHARGE FULL 51ZE TO A SAFE 'APPLIANCES ARE 10, PROVIDE SHUT-OFF VALVE FOR EACH GROUP OF FIXTURE AND EACH FIXTURE SUPPLY. 2004 FBC-PLUMBING NOT A PART OF PLACE OF D15PO5AL SUCH AS THE FLOOR,WATER Tab.7I 0.1,1 510 PO of harizonta!drama e pipe Bf2e TH15 PERMIT HEATER PAN, OUTSIDE THE BUILDING OR AN INDIRECT P 9 pP 3, I I. WHEREVER D1551MILAR METALS ARE TO BE JOINED,A DIELECTRIC FITTING SHALL BE PROVIDED TO WASTE RECEPTOR.THE DISCHARGE PIPE SHALL NOT HAVE CONNECT BOTH TYPES OF PIPES.LMMI ten• sQpe eize in. Ip2, t— ANY TRAPPED SECTIONS AND SHALL HAVE A VISIBLE AIR 1/4"per ft 2 1/2"DIA.?� a I _ __ '' GAP OR AIR GAP FITTING LOCATED IN THE SAME ROOM A5 1/8"per ft 3"TO G"DIA. 12. CONTRACTOR SHALL BE RE5PON51BLE TO COORDINATE ALL ROUGh-IN5 WITH THE MANUFACTURER 8"DIA.e ElnJ11 i _ WAS i THE WATER HEATER.THE DISCHARGE SHALL BE BEFORE MAKING ANY INSTALLATION. ,/ i i INSTALLED IN A MANNERTHAT DOES NOT CAUSE PERSONAL INJURY TO OCCUPANTS IN THE IMMEDIATE i 2° , a 2°�� 13. POTABLE HOT AND COLD WATER SYSTEMS SHALL BE'LEAD FREE„WITH LEAD CONTENT NOT EXCEEDING NOTE: ALL SHOWERS TO HAVE ANTI-SCALD VALVE. 314E' AREA OR STRUCTURAL DAMAGE TO THE BUILDING. 0.2 PERCENT FOR SOLDER AND FLUXES AND 8 PERCENT FOR PIPE FITTINGS, FIXTURES AND TRIM. — — CONTRACTOR SHALL VERIFY MANUFACTURER'S COMPLIANCE, FIXTURE UNITS PER 2004=PLUMEBIING TAB 709.1-(BATH GROU I , 3/4" fl 1 14, ALL POTABLE HOT AND COLD WATER SYSTEMS SHALL BE FLU5hED CLEAR,STERILIZED WITH AN Ref. I 1 M APPROVED SOLUTION AND THOROUGHLY FLU5HED OF ALL U51DUAL SOLUTION AFTER FINAL PRE55URE ail HOT wATeR iN IB2°' �_ =___� ► HA EN. CD SPILL TERMINATE @ G"AFG ON !8„SPLASH APPROVED AND WITH ALL TRIM AND CONNECTIONS IN5TALLED. a3/4”HB BLK t 12 _ I 3B4' w/VAC. BKR 15, PROVIDE SHUT-OFF AND VACUUM BREAKER TO ALL HOSE BIBBS AND FAUCETS WITH HOSE-END CONNECTIONS. I I 2W I G, ALL FLOOR DRAIN5 SHALL HAVE TRAP PRIMERS TO PROTECT THE SEAL OF THE TRAP. e`� j 17. PVC PIPING 15 NOT ALLOWED IN RETURN AIR PLENUMS. IF RETURN AIR PLENUMS ARE USED, IB2" FI12' , CONTRACTOR SHALL REPLACE ALL EX15TING PVC PIPING W€TH CAST IRON OR COPPER PIPING. O 3(4 2, 18. PROVIDE PIPING AS FOLLOWS: DRAIN FIELD: PE PLASTIC PERFORATED FILED TUBING 4"DIAMETER. NOTE: PLEASE REFER TO 51TE PLAN SHEET A-I FOR 51TE DRAINAGE 5Y5TEM DE51GN 15 BASED ON 1/8`°PER FOOT MIN, FALL FOR PIPES 3"OR LARGER AND I/4"PER SPECIFIC DATA,ZONING INFORMATION, ORIENTATION, FOOT. MIN, FALL FOR PIPES 2"OR SMALLER,ANY DEVIATIONS SHALL BE APPROVED BY NOTE:ALL RAINWATER TO BE RETAINED ON SITE. SEE SITE PLAN A-I FOR 50DDED A . Co 2,"\IT HA LANDSCAPING�51TE IMPROVEMENTS, ARCHITECT/ENGINEER. FOR SANITARY PIPING AND CONNECTIONS-SEE PLUMBING SPECS. NOTE:5EE 5HEET A-1 FOR FINI5H FLOOR ELEVATION5 2-WAY C.O. 3® ` 4° PROVIDE FULL OPEN VALVE 19. ALL VENT THROUGH ROOF OPENINGS SHALL BE OFF5ETED TO A MIN. D15TANCE OF 3'-0"FROM PARAPET (FIELD CONDITION) o'o NEAR CURB MAIN WATER5ERVICE WALL OR ROOF EDGE.SEE ARCHITECTURAL DRAWINGS FOR ROOF FLASHING, LEAD FLASHING WILL NOT BE SEE 5hT A-I FOR P COMPLY FBC P GOG.1 (1) ACCEPTED. WATER 4 5EWER CONNECTION5152 5 WATER SERVICE 51ZE PER 2004 FBC AND LOCATION5 PLUMBING TAB G03.I-(LE55 18 FU) a 4°' PVC SAN 5CH 40 (FIELD CONDITION) SEE 5HT A-I FOR TO 5ANITARY 5Y5TEM WATER�SEWER REFER TO 511T A I I CONNECTIONS/51ZE5 a AND LOCATIONS n REFER TO 5HT A 1 .•` ." .�-- ",r 5CALE; 114" : I`-O" ` a yW DATE: - 10-11 08 --- MA111TV PROJECT New 1 Sty SFR OF GREATER MIAMI,111 0. ADDRESS: 6090 SW 63 ST r ; South darn[, Florida OWNER: Habitat for Hurnanity Anne Manning, Exec. Director 305 670-2224 REVISIONS: ERPB 1-13-0 .---------— - --- -- - 935G � ®BBR ARD - a6 2C0 01ML FLORIDA 33256 365 AGENT. NE NIAXIIIIIIIS,MUM DIRECTOR SEAL V�ff%%/�//i F/m/f !%///% ARCHr'E'&C)PhECORb...; 1 F 1 RAut W.BlJbKLE %f/� ARa azas_. PLUMBING