5943 SW 62 ST_EB-93-227 CITY OF SOUTH .MIAMI
Building & Zoning Department
6130 Sunset Drive, 2" Floor Fax # : (305) 666 -4591
South Miami, Florida 33143 Phone: (305) 663 -6325
PEARL Arts & Craft May 4, 1994
6448 S . Dixie Hwy.
South Miami, FL 33143
Dear Applicant :
This letter is to inform you that your request for the approval of
REMODELING & SIGNAGE (Commercial)-- PRELIMINARY
APPlication incorporating the previously suggested, as well as
other chances, including a new freestanding sian design (S Dixie
Hwy. side)
was presented to the Environmental Review and Preservation Board
(ERPB) at their meeting on Thursday, May 3, 1994, and was
Approved 3-0
based on the following conditions (s) :
1) That the inside of the arches and space below the windows, and
below the awnings, be treated with a medium gray, slightly darker
than the facade and slightly lighter than the trim, 2) That a color
band(s) be included around the parts of the buildina facinc the
Parking lot and SW 80 Street, and said color band(s) be submitted
to ERPB for approval; 3) That the sign facing the parking---1o1;,
realizina that it does not comply with signage code/ordinance, be
allowed subiect to variance approval.
Final approval by the ERPB is not authorization to begin
construction. Final approval by ERPB shall elapse after six (6)
months if no permit was issued. You must receive a valid Building
Permit after approval by ERPB.
Final decision by the ERPB may be appealed to the City Commission
by written request to the City Clerk before a Building Permit is
issued.
If you have any questions concerning this matter , please, contact
the Department between the hours of 8 : 00 AM and 5 : 00 PM, Monday
through Friday, at (305) 663 -6326 .
Please refer to file # EB-93-226 .
C=T Y O F S OUTH M=AM=
V7BUILDING AND ZONING
ENVIRONMENTAL REVIEW AND PRESERVATION BOARD APPLICATION
PLEASE, PRINT YOUR NAME AND YOUR TELEPHONE NUMBER IN THE BOX BELOW:
APPLICANT'S NAME: Dorothy Rogers PHONE• 251-3351
AS THE APPLICANT, PLEASE, INDICATE YOUR RELATIONSHIP TO THIS PROJECT:
XXX OWNER OF THE PROPERTY TENANT/LESSEE CONTRACTOR OTHER:
OWNER OF THE BUSINESS ARCHITECT ENGINEER
PLEASE INDICATE WHICH CATEGORY DESCRIBES THE PRESENT USE OF THE PROPERTY:
XX SINGLE-FAMILY RESIDENCE BUSINESS OFFICE RETAIL STORE OTHER:
APARTMENT OR TOWNHOUSE MEDICAL OFFICE =AUTO EPAIR
PLEASE, ANSWER THE FOLLOWING BRIEF QUESTIONS CONCERNING THIS PROJECT:
DO YOU INTEND TO CHANGE THE USE OF THE PROPERTY FROM THAT STATED ABOVE?
XX NO _ YES, THE NEW .USE WILL BE: N/A
WHAT WILL THE TOTAL COST BE TO COMPLETE THIS PROJECT? $ 50,000.00
PLEASE, BRIEFLY SUMMARIZE THE WORK YOU PLAN TO PERFORM:
Demolition of existing structurally damaged home, and construction of new 1-story
single family residence.
WHERE A BOX IS MARKED, PLEASE, PROVIDE THE NECESSARY INFORMATION REQUESTED:
9NAME OF THE
PROPERTY OWNER: Dorothy Rogers PHONE: 251-3351
iami 1strlct Disaster esponse o the United et o 1st urc
MAILING ADDRESS: 10711 S.W. 216th Street, Bay A120, Miami, FLZIp CODE: 33170
ADDRESS OF JOB• 5943 S.W. 62nd Street
SOUTH MIAMI, FLA.
REQUESTED
SIGNAGE AREA. feet by feet = sq ft
STORE FRONTAGE: linear feet on (street name)
REQUESTED OVERALL LENGTH OF
FENCE HEIGHT. feet FENCING REQUESTED:
AREA OF ENTIRE BU
ILDING(S) INCLUDING EXTERIOR WALLS: 1,110 sq ft
AREA OF THE LOT CONTAINED WITHIN THE PROPERTY LINES• 11,770 sq ft
GROSS AREA OF GROSS AREA OF NUMBER OF
EXISTING BLDG: CONSTRUCTION: PKG SPACES:
PLEASE SIGN AND DATE THE APPLICATION:
PLEASE SIGN YOUR NAME ON THE LINE ABOVE PUT TODAY'S DATE
Miami District Disaster Response
of the United Methodist Church
, Rebuilding Office
The '10711 S.W.216 Street, Bay A120
United Miami,FL 33170
Methodist (305)251-3351 Fax(305)251-8919
Church "A Covenant To Rebuild"
December 13 , 1993
Chief Building Official
City of South Miami
6130 Sunset Drive
South Miami, Florida 33143
RE: Master Model
Dear Sir:
Please be advised that it is our intent to utilize the attached
Master Model design in our work in the reconstruction of demolished
homes as_ a result of Hurricane Andrew. The Miami District Disaster
Response of the United Methodist Church (MDDR/UMC) works on houses
that were uninsured or under insured at the time of Hurricane
Andrew. We use volunteer labor or qualified sub-contractors to do
our rebuilding after a professional architect or engineer has
assessed the damage . Our Master Model plan has been approved by
Metro-Dade to be used on an infill basis .
We are submitting our plan to the City of South Miami for approval
to build. While it is not possible to attach a specific number to
the times we expect to build this model, we can affirm that it will
be more than 'twenty-five times throughout South Dade County and at
present once in the City of South Miami .
Thank you for your attention and favorable review of this request .
Please let us know if there is anything further we can do to assist
in this process .
Sincerel ,
Lynette Fields
Rebuilding Director
Miami District Disaster Response
of the United Methodist Church
3
Miami District Disaster Response
of the United Methodist Church
Rebuilding Office
The 10711 S.W.216 Street,Bay A120
United Miami,FL 33170
Methodist (305)251-3351 Fax(305)251-8919
Church "A Covenant To Rebuild"
December 13 , 1993
Chief Building Official
City of South Miami
6130 Sunset Drive
South Miami, Florida 33143
RE: Master Model
Dear Sir:
Please be advised that it is our intent to utilize the attached
Master Model design in our work in the reconstruction of demolished
homes as a result of Hurricane Andrew. The Miami District Disaster
Response of the United Methodist Church (MDDR/UMC) works on houses
that were uninsured or under insured at the time of Hurricane
Andrew. We use volunteer labor or qualified sub-contractors to do
our rebuilding after a professional architect or engineer has
assessed the damage . Our Master Model plan has been. approved by
Metro-Dade to be used on an infill basis.
We are submitting our plan to the City of South Miami for approval
to build. While it is not possible to attach a specific number to
the times we expect to build this model, we can affirm that it will
be more than twenty-five times throughout South Dade County and at
present once in the City of South Miami .
Thank you for your attention and favorable review of this request .
Please let us know if there is anything further we can do to assist
in this process .
Sincerel ,
Lynette Fields
Rebuilding Director
Miami District Disaster Response
of the United Methodist Church
Miami District Disaster Response
of the United Methodist.Church
Rebuilding Office
The 10711 S.W.216 Street,Bay A120
United Miami,FL 33170
MethOdlSt (305)ZS1-3351 Fax(305)251-8919
Church "A Covenant To Rebuild"
December 13 , 1993
Chief Building Official
City of South Miami
6130 Sunset Drive
South Miami, Florida 33143
RE: Master Model
Dear Sir:
Please be advised that it is our intent to utilize the attached
Master Model design in our work in the reconstruction of demolished
homes as� aa result of Hurricane Andrew. The Miami District Disaster
Response of the United Methodist Church (MDDR/UMC) works on houses
that were uninsured or under insured at the time of Hurricane
Andrew. We use volunteer labor or qualified sub-contractors to do
our rebuilding after a professional architect or engineer has
assessed the damage . Our Master Model plan has been approved by
Metro-Dade to be used on an infill basis .
We ate submitting our plan to the City of South Miami for approval
to build. While it is not possible to attach a specific number to
the times we expect to build this model, we can affirm that it will
be more than twenty-five times throughout South Dade County and at
present once in the City of South Miami.
Thank you for your attention and favorable review of this request .
Please let us know if there is anything further we can do to assist
in this process .
Sincerely,
-Lynette Fields
Rebuilding Director
Miami District Disaster Response
of the United Methodist Church
Miami District. Disaster Response
of the United Methodist Church
Rebuilding Office
The 10711 S.W.216 Street,Bay A120
United Miami,FL 33170
Methodist (305)ZSI-3351 Fax(305)Z51-8919
Church "A Covenant To Rebuild."
December 13, 1993
Chief Building Official
City of South Miami
6130 Sunset Drive
South Miami, Florida 33143
RE: Master Model
Dear Sir:
Please be advised that it is our intent to utilize the attached
Master Model design in our work in the reconstruction of demolished
homes as,--a result of Hurricane Andrew. The Miami District Disaster
Response of the United Methodist Church (MDDR/UMC) works on houses
that were uninsured or under insured at the time of Hurricane
Andrew. We use volunteer labor or qualified sub-contractors to do
our rebuilding after a professional architect or engineer has
assessed the damage. Our Master Model plan has been approved by
Metro-Dade to be used on an infill basis .
We are submitting our plan to the City of South Miami for approval
to build. While it is not possible to attach a specific number to
the times we expect to build this model, we can affirm that it will
be more than twenty-five times throughout South Dade County and at
present once in the City of South Miami .
Thank- you for your attention and favorable review of this request .
Please let us know if there is anything further we can do to assist
in this process .
Sincerely,
Lynette Fields
Rebuilding Director
Miami District Disaster Response
of the United Methodist Church
C2TY OF SOU'G'H M=AM=
Building & Zoning Department
6130 Sunset Drive, 2 n Floor Fax #: (305) 666-4591
South Miami, Florida 33143 Phone: (305) 663-6325
Miami District Disaster Response December 22, 1993
of the United Methodist Church
10711 SW 216 Street, Bay 120
Miami, FL 33170
Dear Applicant:
This letter is to inform you that your request for the approval of
NEW S F RESIDEN E, Dorothy Rogers, 5943 SW 62 Street
was presented to the Environmental Review and Preservation Board (ERPB) at
their meeting on Thursday, December 21, 1993, and was
Approved 3-0
based on the following conditions(s) :
Final approval by the ERPB. is not authorization to begin construction. You must receive a
valid Building Permit after approval by ERPB. All permit applications must observe a seven
(7) day ERPB appeal period before such permits can be issued.
Final decision by the ERPB may be appealed to the City Commission by written request to the
City Clerk within seven (7) days of said decision. Final approval by ERPB shall elapse after
six (6) months if no permit was issued.
If you have any questions concerning this matter, please, contact the Department between the
hours of 8:00 AM and 5:00 PM, Monday through Friday, at (305) 663-6326. Please refer to file
# EB-93-227.
Department of Community Affairs- FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FORM 60OA-93 Residential Whole Building Performance Method A SOUTH 7@9
E T NAME: �E BUILDER:
DRESS: Dp OFFICE:PERMITTING 00FH I A M1 LIM TE 7❑8 ❑9 L u��T>rD MraTHoDfs-r PISS sme. pERMITNO. JURISDICTION
NO.:
Please Ty CK
1. New construction or addition I. Ntc(.tt CON-5T.
2. Single family detached or Multifamily attached 2. F4ml> .J D*jAcH1=A
3. If Multifamily-No.of units covered by this submission 3.
'41. If Multifamily, is this a worst case(yes/no) 4. ` Rr s
5. Conditioned floor area (sq.ft.) 5. 1110 sq.ft.
6. Predominant eave overhang(ft.) 6. 2 ft.
7. Porch overhang length (ft.) 7. 5 ft.
8. Glass type and area: Single Pane Double Pane
a. Clear glass 8a. I S& sq.ft. sq. ft.
b. Tint, film or solar screen 8b. - sq.ft. sq.ft.
9. Floor type and insulation:
a. Slab on grade(R-value+perimeter) 9a. R= O ,4_I.ft.
b. Wood, raised (R-value+sq.ft.) 9b. R= - sq.ft.
c. Concrete, raised (R-value) 9c. R= - sq.ft.
10. Net Wall type, area and insulation:
a. Exterior: 1. Concrete block(Insulation R-value) 10a-] R= sq.ft.
2. Wood frame(Insulation R-value) 10a-2 R= I q8'L sq.ft.
3. Steel frame(Insulation R-value) 10a-3 R= - sq.ft.
4. Log(Insulation R-value) 10a-4 R= - - sq.ft.
b. Adjacent: 1. Concrete block(Insulation R-value) 10b-1 R= - sq.ft.
2. Wood frame(Insulation R-value) 10b-2 R= - - sq. ft.
3. Steel frame(Insulation R-value) 10b-3 R= _ sq. ft.
4. Log (Insulation R-value) 10b-4 R= - - sq.ft.
11. Ceiling type,area and insulation:
a. Under attic(insulation R-value) 11a. R= $O 1 1 1 0 sq.ft.
b. Single assembly(Insulation R-value) 11b. R= "' -' sq.ft.
12. Air distribution system:
a. Ducts(Insulation+ Location) 12a. R= 4 ,L►NeoND (condluncand.)
b. Air Handler( Insulation + Location) 12b. R= , CONV (cond./uncond.)
13. Cooling system: 13a. Type: dtru:r_at_-zTjT
(Types:central-split,central-single pkg.,room unit,PTAC.,none) 13b. SEER/EER/COP: 10.0
13c. Capacity: 270,45
14. Heating system: 14a. Type: Fl..W- 3j Q!P _
(Types:heat pump,elec.strip,nat.gas,L.P.gas,room or PTAC,none) 14b. HSPF/COP/AFUE: --
15. Hot water system: 14c. Capacity:
(Types:elec.,natural gas,solar,L.P.gas,none) 15a. Type:
16. Hot Water Credits: 15b. EF: •Sa
a. Heat Recovery(HR) 16a.
b. Dedicated Heat Pump(DHP) 16b. -
17. Infiltration practice: 1,2 or 3 17. 2
18. HVAC Credits(Type in Letter designation:CF-Ceiling Fan,CV-Cross vent, 18. CF
HF-Whole house fan,RB-Attic radiant barrier,MZ-Multizone)
0
19. EPI (must not exceed 100 points) 19. 94.7
a.Total As-Built points EPI =Total As•80111 points x 100 19a." =,q 25
b. Total Base point Total Base points 19b. C4.2pgj
I hereby certify that the plans a specirica' s c e y the calculation are in compliance with the Review of plans and specifications covered by this calculation indicates compliance with
Florida Energy Code. _ the Florida Energy Code. Before construction is completed,this building will be inspected
PREPARED$Y for compliance in accordance with Section 553.908.F.S.
: - OATE
I hereby certify that this wilding is' the rida Energy Coda. BUILDING OFFICIAL
OWNER AGENT. \ DATE: DATE:
SUMMER CALCULATIONS CLIMATE ZONES 7 9O9
BASE BASE SINGLE-PANE DOUBLE-PANE SUMMER AS-BUILT
GLASS x SUMMER = SUMMER GLASS x SUMMER POINT MULT. OR SUMMER POINT MULT. x OVERHANG= GLASS
AREA PT.MULT. POINTS AREA CLEAR TINT' CLEAR TINT' FACTOR(6A-1)1 SUM.PTS
N 19, 109.7 I N 64.5 65.2 60.2 54.9 1.00 I
NE 109.7 NE 94.8 94.5 88.0 78.2
E 41 109.7 E 36.3 133.9 127.0 109.5
SE 109.7 SE 146.2 143.0 135.0 116.1
S 22 109.7 24 t S 2 CM-A) 132.5 124.2 107.7 1
SW 109.7 SW 146.2 143.0 135.0 116.1
W 75 109.7 1 W . 133.9 127.0 109.5 6
NW 109.7 NW 94.8 94.5 88.0 78.2
H' 109.7 H' 428.7 354.7 380.6 278.9
S i v .y •TO 3
3G• .75
7
COND TOTAL BASE BASE ADJUSTED AS BUILT
.15 x FLOOR + GLASS = ADJUST. x GLASS = GLASS GLASS
AREAL AREA I FACTOR I SUBTOTAL I BASE SP SUBTOTAL
.15 1 Ito ► !•O 17 I I IS 312 1
COMPONENT BASE SUMMER BASE COMPONENT SUMMER AS-BUILT
DESCRIPTION AREA x POINT.MULT. SUMMER DESCRIPTION AREA x POINT.MULT. = SUMMER
POINTS 0-2 THRU 6A-6 POINTS
EXTERIOR 'Z 1.6 l 15-71
a ADJACENT 1.0
3:
EXTERIOR. 6.4 2 INSLLL. 20
o ADJACENT 2.6
0
UNDER ATTIC (I I 1 .8 $ N IC Zrlo 1110
Z OR SINGLE .8
ui ASSEMBLY
v BASE CEILING AREA EQUALS FLOOR AREA DIRECTLY UNDER CEILING,AS-BUILT CEILING AREA EQUALS ACTUAL CEILING SQUARE FOOTAGE
Q SLAB PERIMETER .20.0 -• (. 4w d&A OIL f. 0.0 seso
S RAISED AREA -2.16
U.
J
FOR SLAB ON GRADE USE PERIMETER LENGTH AROUND CONDITIONED FLOOR.FOR RAISED FLOORS USE AREA OVER UNCONDITIONED SPACE.
INFILTRATION 1110 1 14.7 1 Ira 3 a I NtzRj G 2 I Mo 1 14.1 1201
USE TOTAL FLOOR AREA OF CONDITIONED SPACE
TOTAL COMPONENT BASE SUMMER POINTS 3 33 TOTAL COMPONENT AS-BUILT SUMMER POINTS 1 34p q-70
v
COOLING BASE COOLING I TOTAL BASE BASE TOTAL AS-BUILT I AS-BUILT I AS-BUILT AS-BUILT
SYSTEM SYSTEM x SUMMER = COOLING AS-BUILT x OM x CSM x CCM = COOLING
MULTIPLIER POINTS POINTS SUM.PTS. 0- 0-8 MA-1191 POINTS
.37 34, 33 do 12,T0+ 34,9To 1.1 O .3d. .$o I 1 248
HOT NUMBER BASE BASE AS-BUILT NUMBER AS-BUILT AS-BUILT AS-BUILT
WATER OF x HOT WATER HOT WATER HOT WATER OF x HWM x HWCM = HOT WATER
SYSTEM BEDROOMS MULTIPLIER POINTS SYSTEM DESC. BEDROOMS 0-9 6A•20 POINTS
3 3319 9016 fAIcc, .b 3 3318 - 9954-
'H=HORIZONTAL GLASS(SKYLIGHTS) 'FOR GLASS WITH KNOWN SHADING COEFFICIENT,SEE SECTION 1.1 APPENDIX C.TINT MULTIPLIERS MAY BE
USED FOR GLASS WITH SOLAR SCREENS,FILM,OR TINT.
SUMMER POINT MULTIPLIERS (SPM) CLIMATE ZONES 708 9
6A-1 SUMMER OVERHANG FACTORS[SOF1 FOR SINGLE AND DOUBLE PANE GLASS.
OH RATIO .00-.11 .12-.17 .18-.26 .27•.35 .36.46 .47-.57 .58-30 .71-.83 .84-1.18 1.19.1.72 1.73.2.73 2.74+
�- N 600 .94 .91 .87 .84 .80 .77 .74 .70 .64 .58 .53
F NE/NW 1.00 .95 .92 .86 .81 .76 .72 .68 .64 .56 .50 .44
c EN 1.00 .95 .93 .8 .81 .7 .70 .65 .59 .46 .41 .34
y L SEISW 1.00 .95 .92 .85 7-TIF .70 .64 .58 .52 .42 .34 .28
S I 0.0�0) .94 .91 .83 .75 .67 .60 .54 .48 .39 .33 .30
, ft, , ft 91/2,
'To select by OveftM Length,no part of qI=shall be more than 8 ft below the overhang.
6A-2 WALL SUMMER POINT MULTIPLIERS SPM
FRAME
CONCRETE BLOCK' FACE BRICK LOG
INT.INSULATION EXT.INSU R-VALUE WOOD FR
WOOD STEEL NORMAL WE NOR.WT. 06.9 4.6 6 INCH
R VALUE EXT ADJ EXT ADJ R-VALUE EXT ADJ EXT 710.9 1.3 R-VALUE EXT
06.9 8.5 3.4 11.6 44 02.9 4.2 1.9 4.2 1118.9 1.1 02.9 2.8
7-10.9 3.2 1.3 5.5 21 3-4.9 2.7 1.3 1.7 19-25.9 .6 0:` 3-6.9 1.9
1112.9 2.7 1.0 4.2 16 5-6.9 2.0 1.1 1.2 .' 2680 .3 78U 1.5
1318.9 2.4 .9 3.9 15 7-10.9 1.6 .8 .7 R-VALUE BLOCK 81 CH
19-25.9 .6 3.4 13 ® ' 11-18.9 1.0 .6 .3 M 0-2.9 2.3 1` R-VALUE EXT
268 U 1.0 .3 1.9 .7 19-25.9 .5 .3 3.6.9 1.6 0.2.9 1.9
268U 3 2 79.9 .9 � 36.9 1.4
6A-3 DOOR SUMMER POINT MULTIPLIERS(SPM) 6A-4 CEILING SUMMER POINT MULTIPLIERS SPM
DOOR TYPE EXTERIOR I ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF
R-VALUE SPM R-VALUE SPM CEILING TYPE
WOOD 9.4 3.8 19-21.9 1.5 10.10.9 4.0 R-VALUE DROPPED EXPOSED
22-25.9 1.3 11-12.9 3.6 10-13.9 4.1 4.6
INSULATED 6.4 2.6 26.29.9 to 13-18.9 3.3 14.20.9 2.9 3.1
30-37.9 .8 19-25.9 2.5 21&UP 1.9 2.0
38 8 U .6 26-29.9 1.6
6A-5 FLOOR SUMMER POINT MULTIPLIERS SPM
SLAB-0N-GRADE RAISED RAISED WOOD'
EDGE INSULATION CONCRETEp POST OR PIER STEM WALL w/UNDER ADJACENT
CONSTRUCTION FLOOR INSULATION
R-VALUE SPM R-VALUE SPM R-VALUE SPM SPM SPM
0-2.9 0-2.9 .8 0-6.9 2.4 -4.2 3.4
3-4.9 -17.4 3-4.9 -.3 N 7-10.9 -.3 -.9 1.3
r
5-6.9 -16.6 5.6.9 -.4 x 11-18.9 -.3 -.6 1.0
6A-6 INFILTRATION SUMMER POINT MULTIPLIERS(SPM) 6A-7 DUCT MULTIPLIERS DM
INFILTRATION PRACTICE RETURN DUCTS RETURN DUCTS
SEE TABLE 6A-21 SPM R-VALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE
PRACTICE#1 18.6 SUPPLY DUCTS IN 4.2.5.9 1.14 1.10
PRACTICE#2 4. 6.0-6.6 1.10 1.07
PRACTICE#3 10.1 UNCONDITIONED SPACE 6.7 8 Up 1.09 1.06
SUPPLY DUCTS IN 4.2-5.9 1.10 1.00
CONDITIONED SPACE' 6.0.6.6 1.07 1.00
6A-8 COOLING SYSTEM MULTIPLIERS CSM
SYSTEM TYPE COOLING SYSTEM MULTIPLIERS CSM
Central Units(SEER)
Rating 7.5-7.9 8.0-8.4 8.5-8.8 8.9-9.4 9.5-9.9 10.0 10.4 10.5-10.9 11.0-11.4 11.5-11.9 12.0-12.4
SM .45 .43 .40 .38 .36 .34 .32 .31 .30 .28
PTAC 8 Room Units(EER) 12.5-12.9 13.0-13.4 13.5-13.9 14.0-14.4 14.5-14.9 15.0 15.4 15.5-15.9 16.0.164 165 169 170174 17.5 8 U S .27 .26 .25 .24 .24 .23 .22 .21 .21 .20 .19
MINIMUMS:CENTRAL UNITS-AIR COOLED SPLIT SYSTEM 10.0 SEER,SINGLE PKG.9.7 SEER,GROUND WATER HEAT PUMP 11.0 EER.PTAC-SEE TABLE 6.2.
6A-9 HOT WATER MULTIPLIERS HWM
SYSTEM TYPE HOT WATER MULTIPLIERS HWM
Electric Resistance EF .80-.81 .82-.83 .84-.85 .86-.87 •.90 .91-.93 .94.96 .97 8 U
HWM 3650 3561 3476 3395 3318 3208 3106 1 3010
Natural Gas EF .43-.47 .48-.49 .50-.51 .52-.53 .54-.55 .56-.57 .58-.59 .60-.61 .62-.63 .64-.65 .66 8 U
HWM 2602 2331 2238 2151 2072 1998 1929 1865 1804 1748 1695
LP Gas HWM 3295 2951 2833 2724 2624 2530 2443 2361 2285 2214 2147
FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. z MULTIPLIERS FOR OTHER TYPES OF RAISED WOODASSEMBLIES SEE
SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION.
WINTER CALCULATIONS CLIMATE ZONES 7C 9
BASE BASE SINGLE-PANE DOUBLE-PANE WINTER AS-BUILT
GLASS x WINTER = WINTER GLASS x WINTER POINT MULT. OR WINTER POINT MULT. x OVERHANG= GLASS
AREA PT.MULT. POINTS AREA CLEAR TINT= CLEAR TINT ACTOR(6A-10) WIN.PTS
N 1 -.4 N IS Q9 3.7 2.2 2.4
NE -.4 NE 2.9 2.9 1.4 1.8
E •.4 E t2, .2 -1.1 - .6 5.
SE -.4 SE -2.1 •2.0 -3.3 -2.5
S -.4 S 2 2. -1.8 -3.1 -2.4
SW -.4 SW -2.1 -2.0 -3.3 -2.5
W -.4 W .2 -1.1 - .6
NW -.4 NW 2.9 2.9 1.4 1.8
H' -.4 H' :8.9 •7.8 -7.3 -5.7 9 2 1
5 � 5
COND TOTAL BASE BASE ADJUSTED AS-BUILT
.15 x FLOOR + GLASS ADJUST. x GLASS = GLASS GLASS
AREA I AREA FACTOR I SUBTOTAL BASE WP SUBTOTAL
.15 1 1110 1 160, 1 1.0 - 2
COMPONENT BASE WINTER BASE COMPONENT WINTER AS-BUILT
AREA z - WINTER AREA z POINT.MULT. = WINTER
DESCRIPTION POINT.MULT. - POINTS DESCRIPTION 6A-11THRU 6A•15 POINTS
EXTERIOR a .3 2 1 2
a ADJACENT .5
3
" � 1
EXTERIOR 1 20 1 1.8 S& L.•
cc
a ADJACENT 1.3
c
c UNDER ATTIC 1 1110 1 .1
OR SINGLE 1
0 ASSEMBLY
v BASE CEILING AREA EQUALS FLOOR AREA DIRECTLY UNDER CEILING,AS-BUILT CEILING AREA EQUALS ACTUAL CEILING SQUARE FOOTAGE.
v 1
� SLAB PERIMETE 140C -2.1 1 � OZ r!!s!:atg •?• -�3dL
oc RAISED AREA - .28
J
LL. FOR SLAB ON GRADE USE PERIMETER LENGTH AROUND CONDMONED FLOOR.FOR RAISED FLOORS USE AREA OVER UNCONDITIONED SPACE
INFILTRATION 1.2 332 12 1 ssa.
USE TOTAL FLOOR AREA OF CONDITIONED SPACE.
v v
TOTAL COMPONENT BASE WINTER POINTS I TOTAL COMPONENT AS-BUILT WINTER POINTS I I's
BASE HEATING I TOTAL BASE BASE TOTAL AS-BUILT I AS-BUILT I AS-BUILT AS-BUILT
HEATING SYSTEM x WINTER - HEATING AS-BUILT x DM x HSM x HCM = HEATING
SYSTEM MULTIPLIER POINTS POINTS WIN.PTS 6A-16 0-1 6A-18 POINTS
1.1 40(p ls4 l t•O - 1723
BASE BASE BASE TOTAL AS-BUILT AS-BUILT AS-BUILT TOTAL
COOLING + HEATING + HOT WATER = BASE COOLING ' + HEATING + HOT WATER = AS-BUILT
p POINTS POINTS I POINTS POINTS POINTS POINTS POINTS POINTS
From P.2) From P.2 Enter on P.1 From P.2 From P.2 Enter on P.1
270 5 24.9-0 1 3 792
H=HORIZONTAL GLASS(SKYLIGHTS) 'FOR GLASS WITH KNOWN SHADING COEFFICIENT,SEE SECTION 1.1 APPENDIX C.TINT MULTIPLIERS MAY BE
USED FOR GLASS WITH SOLAR SCREENS,FILM,OR TINT.
1
WINTER POINT MULTIPLIERS (WPM) CLIMATE ZONES 7(!!�O i
6A-10 WINTER OVERHANG FACTORS 0
OH RATIO .00-.11 1 .12-.17 1 .18-.26 .27-.35 .36•.46 1 .47-.57 1 .58-.70 1 .71-.83 .841.18 1.191.72 1.73 2.73 2.74+
SINGLE PANE GLASS
N 1.00 1.03 1.04 1.06 1.07 1.09 1.11 1.12 1.14 1.18 1.22 1.26
-NE/NW 1.00 1.05 1.08 1.13 1.17 1.21, 1.24 1.27 1.30 1.37 1.45 1.51
ENV 1.00 2.04 2.58 f-3-701 rM. 9.43 11.04 14.42 18.12 22.04
m SE/SW 1.00 .91 .87 .76 .64 .48 .15 -.03 -.43 -.91 -1.46
c S 1.00 .94 .91 .79 .65 .47 .28 .26 34 1.11 1.68 1.92
DOUBLE PANE GLASS
y N 1.00 1.03 1.05 1.08 1.10 1.12 1.14 1.17 1.18 1.24 1.29 1.34
NE/NW 1.00 1.08 1.12 1.20 1.26 1.32 1.37 1.41 1.47 1.57 1.69 1.78
EIW 1.00 .85 .74 .55 .34 .10 -.12 -.36 -.63 -1.17 -1.77 -2.41
SE/SW 1.00 .95 .92 .85 .77 .67 .57 .45 .34 .08 -.23 -.58
S 1.00 .96 .94 .87 .78 .66 .54 .38 .15 -.34 -.70 -.86
OH LENGTH' 0 ft. 1 ft. 1'/z ft. 2 ft. 3 ft 3'/2 ft. 1 4%ft 5'h f 6'/s ft. 91h ft 14 ft 20 ft.+
'TO SELECT BY OVERHANG LENGTH,NO PART OF GLASS SHALL BE MORE THAN 8 FT.BELOW THE OVERHANG,
6A41 WALL WINTER POINT MULTIPLIERS PM
FRAME CONCRETE BLOCK' FACE BRICK LOG
INT.INSULATION W.INSU R-VALUE WOOD FR
WOOD STEEL NORMAL WT. I NOR WT a 0-6.9 2.4 IN
R-VALUE EXT ADJ EXT ADJ ;I ' R-VALUE EXT ADJ EXT 710.9 .6 R-VALUE EXT
0.6.9 2.5 1.7 3.4 2.2 0.2.9 1.9 .7 19 w ' 1118.9 .5 02.9 .6
01 7-10.9 .8 .6 1.5 1.0 a 34.9 1.2 .5 6 1925.9 .2 36.9 .3
11-12.9 .6 .5 1.1 0.8 L. 5.6.9 .9 .4 3 26&U .1 7&U .2
13-18.9 6 .5 1.0 0.7 7-10.9 .7 .4 2 R-VALUE BLOCK x INC
19-25.9 11-18.9 .2 0-2. -VAL E EXT
26&U .2 .2 0.4 1 0.3 19-25.9 .2 .1 3-6.9 .6 � n.9 a
.2
26&UP A .0 j���� ���� 36.9 .1
10A(in 6A-12 DOOR WINTER POINT MULTIPLIERS PM) 6A-13 CEILING WINTER POINT MULTIPLIERS P
DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF
R-VALUE WPM R-VALUE WPM CEILING TYPE
WOOD 2.8 1.9 19-21.9 .3 10-10.9 .6 R-VALUE DROPPED EXPOSED i
22-25.9 .2 11-12.9 .5 10-13.9 .0 .1
INSULATED 1.8 1.3 26-29.9 .2 13-18.9 .5 1420.9 .0 .0
30.37.9 .1 19-25.9 .3 21&Uo 0 0
38&U .1 26-29.9 A
i
6A-14 FLOOR WINTER POINT MULTIPLIERS(WPM)
aM RAISED WOOD'
SLAB-0N-GRADE RAISED POST OR PIER STEM WALL wl UNDER
EDGE INSULATION CONCRETE ADJACENT
CONSTRUCTION FLOOR INSULATION
R-VALUE WPM "'g": R-VALUE WPM $;, R-VALUE WPM WPM WPM
0.2.9 2. 0-2.9 1.0 0-6.9 2.7 0.3 1.7
34.9 -2.6 3-4.9 .3 7-10.9 .7 0 .6 I
5-6.9 -27 = 5-6.9 .1 11-18.9 .4 0 .5
6A-15 INFILTRATION WINTER POINT MULTIPLIERS(WPM) 6A-16 DUCT MULTIPLIERS DM
INFILTRATION PRACTICE WPM RETURN DUCTS RETURN DUCTS
SEE TABLE 9P R-VALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE
PRACTICE#1 1.9 SUPPLY DUCTS IN 4.2-5.9 1.14 1.10
PRACTICE#2 UNCONDITIONED SPACE 6.0-6.6 1-in 1.07
PRACTICE#3 .6 6.7&U -1-69
SUPPLY DUCTS IN 4.2-5.9 1.10 1.00
CONDITIONED SPACE' 6.0-6.6 1.07 1.00
6A-17 HEATING SYSTEM MULTIPLIERS HSM
SYSTEM TYPE HEATING SYSTEM MULTIPLIERS HS
Central Heat HSPF 6.40-6.79 6.806.89 6.90.7.39 7.40-7.89 7.90-8.39 1 8.40-8.89 8.9-9.39 9.4-9.89
Pump Units HSM .53 - .50 .49 .46 .43 .41 .38 .36
HSPF 9.9010.39 10.4010.89 10.9011.39 11.4011.89 11.90-12.39 12.40&u
HSM .34 .33 .31 .30 .29 .28 ;
PTHP COP 2.50-2.69 2.702.89 2.903.09 3.10-3.29 3.303.49 3.503.69 3.703.89 3.90-4.19
HSM .40 .37 .32 .30 .29 .27 .26
Electric Stri 1.0
Gas&LP Gas 1.0 See Table 6A•1 for Credit Multi lie
MINIMUMS:CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6.8 HSPF,SINGLE PKG.6.6 HSPF,WATER SOURCE 3.8 COP,GROUND WATER SOURCE 3.4 COP,PTHP SEE TABLES 6-6 T06-8.
FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOODASSEMBLIES SEE
SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION.
ADDITIONAL TABLES CLIMATE ZONES 7(99
6A-18 HEATING CREDIT MULTIPLIERS HC
SYSTEM TYPE HEATING CREDIT MULTIPLIERS HC
At)ic Radiant Barrier HCM .98
Multizone HCM .95
Natural Gas AFUE .68-.72 .73-.77 .78-.82 .83-.87 .88-.92 .93&U
HCM .56 .52 .49 .46 .44 .41
6A-19 COOLING CREDIT MULTIPLIERS CCM
SYSTEM TYPE COOLING CREDIT MULTIPLIERS CCM
Ceiling Fans .86'
Cross Ventilation W Credit may be taken for only
Whole House Fan .95'
Multizone .95 one of these system types concurrently.
I Attic Radqant Barrier .95
6A-20 HOT WATER CREDIT MULTIPLIERS(HWCM)
SYSTEM TYPE HOT WATER CREDIT MULTIPLIERS HWCM
Heat Recovery Unit With Air Conditioner Heat PUMP
HWCM .62 .58
Dedicated Heat Pump EF 2.0-2.49 2.5-2.99 3.0-3.49 3.5&U
HWCM .44 .35 .29 .25
Solar EF 1.0-1.9 2.0.2.9 3.0-3.9 4.0-4.9 5.0&U
HWCM .84 42 .28 21 .17
A HWM MUST BE USED IN CONJUNCTION WITH ALL HWCM.SEE TABLE 6A-9.EF MEANS ENERGY FACTOR.
6A-21 INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST SEE SECTION 606
COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
PRACTICE#1 606.1 COMPLY WITH ALL INFILTRATION PRESCRIPTIVES.
Windows Maximum of 0.34 CFM per linear foot of operable sash crack includes sliding lass doors). .i
Exterior&Adjacent Doors Maximum of 0.5 CFM per sq.ft.of door area;solid core wood panel,insulated or glass doors only. ✓
Exterior Joints&Cracks To be caulked asketed weatherstripped or otherwise sealed.
PRACTICE#2 606.1 COMPLY WITH#1 AND THE FOLLOWING:
Exterior Walls and Floors Top plate penetrations sealed.Infiltration barrier installed.Sole late/floor joint caulked or sealed.
Exterior Walls&Ceilings Penetrations joints and cracks on interior surface caulked sealed or gasketed.
Ductwork Ductwork in unconditioned space must be sealed.
Fireplaces Eguipped with outside combustion air,doors and flue dampers.
Exhaust Fans Equipped with dampers.Combustion devices see 606.1.A.2 ✓
PRACTICE#3 606.1 COMPLY WITH PRACTICES#1 AND#2 AND THE FOLLOWING:
Ceilings Infiltration barrier installed.
Interior Walls Top penetrations sealed or joints&cracks on interior walls caulked;sealed or gasketed.
Recessed Lights Sealed from conditioned&insulated from ventilated attics aces.
Ductwork All ductwork located in conditioned space.
Combustion Appliances Be in unconditioned space(except direct vent),draw air from unconditioned space,exhaust
by-products to outside. Combustion cooking appliances see Section 606.1.A.3.
6A-22 OTHER PRESCRIPTIVE MEASURES must be met or exceeded by all residences.
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 612.1 Comply with efficiency requirements in Table 6-11.Switch or clearly marked circuit breaker(electric) I
or cutoff as must be provided.External or built-in heat trap required.
Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated).Non-commercial pools must have
a pump timer.Gas spa&pool heaters must have a minimum thermal efficiency of 78%.
Shower Heads 612.1 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG.
Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,'
sealed,insulated,and installed in accordance with the criteria of Section 610.Ducts in unconditioned
attics must be insulated to a minimum of R-6.Air handlers shall not be installed in attics unless in
mechanical closet.
HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system.
Insulation 604.1,602.1 Ceilings-Min.R-19.Common walls-Frame R-11 or CBS R-3 both sides.Common ceiling&floors R-11.