Loading...
06-2124-015GENERAL ELECTRICAL NOTES - ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE IN THE HABITABLE AREAS. - NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION. - A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION. - MAIN CIRCUIT BREAKER PANELS SHALLBE LOCATED ABOVE BASE FLOOD ELEVATION. - WE WILL CONFER WITH FLORIDA POWER d LIGHT TO LOCATE THE ELECTRIC METER TO COMPLY WITH FEDERAL EMERGENCY MANAG=EMENT AGENCY REQUIREMENTS. - ALL ELECTRICAL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH LOCAL CODES AND ORDINANCE f ALL STANDARDS OF CONSTRUCTION ESTABLISHED BY THE LANDLORD. - ALL CONDUCTORS SHALL BE TWH OR THWN COPPER ALL EXPOSED CONDUITS SHALL BE RUN AS NEAT AS POSSIBLE AND PAINTED TO MATCH COLOR OF SURROUNDINGS. P.V.G. CONDUIT SHALL ONLY BE USED IN SLAB OR UNDERGROUND AT A MINIMUM DEPTH OF 24'. - FLEXIABLE CONDUIT SHALL BE USED FOR CONNECTION TO ALL VIBRATING EQUIPMENT SUCH AS MOTORS, ETC. - ALL WIRING DEVICES SHALL BE LEVITON 'DECORA' SERIES OR EQUAL AS APPROVED BY ARCHITECT OR ENGINEER COLOR SELECTED BY ARCHITECT. - ALL RECEPTACLES SHALL BE INSTALLED AT 12'AFF. UNLESS OTHERWISE NOTED. - ELECTRICAL POWER AND CONTROL WIRING FOR HVAC AND MECHANICAL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR - ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND SUSPENSION SYSTEM FOR SELECTION OF THE PROPER TRIM AND SUPPORT ARRANGEMENT OF THE FIXTURE. - ELECTRICAL CONTRACTORS SHALL COORDINATE HIS WORK WITH THE ARCHITECT BEFORE ROUGH INSTALLATION OF LIGHTS, RECEPTACLES, SWITCHES AND EQUIPMENT FOR EXACT LOCATIONS. - ALL ELECTRICAL EQUIPMENT MUST BE U.L. APPROVED. 2 " 1/0 THWN 11/1 1 " 2 THWN (N) z '3500%- Emp-1018 2 ■ 2 " 4/O THWN I* 2 THWN (N) 2 A 1/0 THWN 11/2' 1 M 2 THWN (N) PNL PNL 1 " ro THWN (POOL BOND) A B EXTEND AS 1 " 2 THWN -3/4' DIRECTED BY FPL CND• -- - - - - - - - _ CONNECT TO A CONCRETE ENCASED ELECTRODE BOND TO A 5/8' X 20' GND. ROD AND TO A 3/4' — — COPPER WATER PIPE STUB -OUT ELECTRICAL RISER DIAGFRAM N.T.S. 77 . at rfRE { Jo BoafR* fl & Anciate§ U M H 00 m In 00 N N 00 O .� u s� O , M a/ 01 cd v ti Cd U.z O Cd N Q, M 0000 N 0000 'b C o wv fit~ W � 00 1� O N ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF J. BONFILL & ASSOCIATES, INC., AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF J. BONFILL & ASSOCIATES, INC. REVISIONS I BY Date: 8 -28 -06 Job: MENDEZ Drawn: H.F. Checked: J.B.G. Scale: AS SHOWN SHEET OF 2 Wby-OIL