06-2124-015GENERAL ELECTRICAL NOTES
- ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD
ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND
SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUITS FROM THOSE IN
THE HABITABLE AREAS.
- NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE
FLOOD ELEVATION.
- A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION.
- MAIN CIRCUIT BREAKER PANELS SHALLBE LOCATED ABOVE BASE FLOOD
ELEVATION.
- WE WILL CONFER WITH FLORIDA POWER d LIGHT TO LOCATE THE ELECTRIC
METER TO COMPLY WITH FEDERAL EMERGENCY MANAG=EMENT AGENCY
REQUIREMENTS.
- ALL ELECTRICAL WORK PERFORMED UNDER THIS CONTRACT SHALL
COMPLY WITH LOCAL CODES AND ORDINANCE f ALL STANDARDS OF
CONSTRUCTION ESTABLISHED BY THE LANDLORD.
- ALL CONDUCTORS SHALL BE TWH OR THWN COPPER ALL EXPOSED
CONDUITS SHALL BE RUN AS NEAT AS POSSIBLE AND PAINTED TO MATCH
COLOR OF SURROUNDINGS. P.V.G. CONDUIT SHALL ONLY BE USED IN SLAB
OR UNDERGROUND AT A MINIMUM DEPTH OF 24'.
- FLEXIABLE CONDUIT SHALL BE USED FOR CONNECTION TO ALL VIBRATING
EQUIPMENT SUCH AS MOTORS, ETC.
- ALL WIRING DEVICES SHALL BE LEVITON 'DECORA' SERIES OR EQUAL
AS APPROVED BY ARCHITECT OR ENGINEER COLOR SELECTED BY
ARCHITECT.
- ALL RECEPTACLES SHALL BE INSTALLED AT 12'AFF. UNLESS OTHERWISE
NOTED.
- ELECTRICAL POWER AND CONTROL WIRING FOR HVAC AND MECHANICAL
EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL
CONTRACTOR
- ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND
SUSPENSION SYSTEM FOR SELECTION OF THE PROPER TRIM AND SUPPORT
ARRANGEMENT OF THE FIXTURE.
- ELECTRICAL CONTRACTORS SHALL COORDINATE HIS WORK WITH THE
ARCHITECT BEFORE ROUGH INSTALLATION OF LIGHTS, RECEPTACLES,
SWITCHES AND EQUIPMENT FOR EXACT LOCATIONS.
- ALL ELECTRICAL EQUIPMENT MUST BE U.L. APPROVED.
2 " 1/0 THWN 11/1
1 " 2 THWN (N) z
'3500%-
Emp-1018
2 ■ 2 " 4/O THWN
I* 2 THWN (N)
2 A 1/0 THWN
11/2' 1 M 2 THWN (N)
PNL PNL 1 " ro THWN (POOL BOND)
A B
EXTEND AS 1 " 2 THWN -3/4'
DIRECTED BY FPL CND•
-- - - - - - - - _ CONNECT TO A CONCRETE ENCASED ELECTRODE
BOND TO A 5/8' X 20' GND. ROD AND TO A 3/4'
— — COPPER WATER PIPE STUB -OUT
ELECTRICAL RISER DIAGFRAM
N.T.S.
77 .
at
rfRE {
Jo BoafR* fl & Anciate§
U
M
H
00
m
In
00
N
N
00
O
.�
u
s�
O
,
M
a/
01
cd
v
ti
Cd
U.z
O
Cd
N Q, M 0000
N 0000
'b
C o
wv fit~
W � 00
1�
O
N
ALL DRAWINGS AND
WRITTEN MATERIAL
APPEARING HEREIN
CONSTITUTE THE
ORIGINAL AND
UNPUBLISHED WORK OF
J. BONFILL &
ASSOCIATES, INC., AND
MAY NOT BE
DUPLICATED, USED OR
DISCLOSED WITHOUT
THE EXPRESS WRITTEN
CONSENT OF J. BONFILL
& ASSOCIATES, INC.
REVISIONS I BY
Date:
8 -28 -06
Job: MENDEZ
Drawn: H.F.
Checked: J.B.G.
Scale: AS SHOWN
SHEET
OF 2
Wby-OIL